Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Microsc Microanal ; 23(4): 809-817, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28532530

RESUMO

Beam damage is a major limitation in electron microscopy that becomes increasingly severe at higher resolution. One possible route to circumvent radiation damage, which forms the basis for single-particle electron microscopy and related techniques, is to distribute the dose over many identical copies of an object. For the acquisition of low-dose data, ideally no dose should be applied to the region of interest before the acquisition of data. We present an automated approach that can collect large amounts of data efficiently by acquiring images in a user-defined area-of-interest with atomic resolution. We demonstrate that the stage mechanics of the Nion UltraSTEM, combined with an intelligent algorithm to move the sample, allow the automated acquisition of atomically resolved images from micron-sized areas of a graphene substrate. Moving the sample stage automatically in a regular pattern over the area-of-interest enables the collection of data from pristine sample regions without exposing them to the electron beam before recording an image. Therefore, it is possible to obtain data with minimal dose (no prior exposure during focusing), which is only limited by the minimum signal needed for data processing. This enables us to minimize beam-induced damage in the sample and to acquire large data sets within a reasonable amount of time.

2.
SLAS Technol ; 28(2): 55-62, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36503082

RESUMO

The spot assay of the budding yeast Saccharomyces cerevisiae is an experimental method that is used to evaluate the effect of genotypes, medium conditions, and environmental stresses on cell growth and survival. Automation of the spot assay experiments from preparing a dilution series to spotting to observing spots continuously has been implemented based on large laboratory automation devices and robots, especially for high-throughput functional screening assays. However, there has yet to be an affordable solution for the automated spot assays suited to researchers in average laboratories and with high customizability for end-users. To make reproducible spot assay experiments widely available, we have automated the plate-based yeast spot assay of budding yeast using Opentrons OT-2 (OT-2), an affordable liquid-handling robot, and a flatbed scanner. We prepared a 3D-printed mount for the Petri dish to allow for precise placement of the Petri dish inside the OT-2. To account for the uneven height of the agar plates, which were made by human hands, we devised a method to adjust the z-position of the pipette tips based on the weight of each agar plate. During the incubation of the agar plates, a flatbed scanner was used to automatically take images of the agar plates over time, allowing researchers to quantify and compare the cell density within the spots at optimal time points a posteriori. Furthermore, the accuracy of the newly developed automated spot assay was verified by performing spot assays with human experimenters and the OT-2 and quantifying the yeast-grown area of the spots. This study will contribute to the introduction of automated spot assays and the automated acquisition of growth processes in conventional laboratories that are not adapted for high-throughput laboratory automation.


Assuntos
Robótica , Saccharomyces cerevisiae , Humanos , Saccharomyces cerevisiae/genética , Ágar , Automação , Genótipo
3.
Curr Protoc ; 1(4): e68, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33822482

RESUMO

High-throughput, high-content imaging technologies and multiplex slide scanning have become widely used. Advantages of these approaches include the ability to archive digital copies of slides, review slides as teams using virtual microscopy software, and standardize analytical approaches. The cost and hardware and software inflexibility of dedicated slide scanning devices can, however, complicate implementation. Here, we describe a simple method that allows any microscope to be used for slide scanning. The only requirements are that the microscope be equipped with a motorized filter turret or wheels (for multi-channel fluorescence) and a motorized xyz stage. This example uses MetaMorph software, but the same principles can be used with any microscope control software that includes a few standard functions and allows programming of simple command routines, or journals. The series of journals that implement the method perform key functions, including assistance in defining an unlimited number of regions of interest (ROI) and imaging parameters. Fully automated acquisition is rapid, taking less than 3 hr to image fifty 2.5-mm ROIs in four channels. Following acquisition, images can be easily stitched and displayed using open-source or commercial image-processing and virtual microscope applications. © 2021 Wiley Periodicals LLC. Basic Protocol 1: Hardware and software configuration Basic Protocol 2: Create a preliminary scan Basic Protocol 3: Select, save, and position ROIs Basic Protocol 4: Determine and set autofocus parameters Basic Protocol 5: Acquire tiled images Basic Protocol 6: Review the scans Basic Protocol 7: Reimage ROIs as needed Basic Protocol 8: Stitch, stack, and assemble images Basic Protocol 9: Repeat scanning for multiplex immunostaining or background subtraction.


Assuntos
Microscopia , Software , Computadores , Testes Diagnósticos de Rotina , Processamento de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA