Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Epilepsia ; 65(8): 2280-2294, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38780375

RESUMO

OBJECTIVE: This study was undertaken to develop and evaluate a machine learning-based algorithm for the detection of focal to bilateral tonic-clonic seizures (FBTCS) using a novel multimodal connected shirt. METHODS: We prospectively recruited patients with epilepsy admitted to our epilepsy monitoring unit and asked them to wear the connected shirt while under simultaneous video-electroencephalographic monitoring. Electrocardiographic (ECG) and accelerometric (ACC) signals recorded with the connected shirt were used for the development of the seizure detection algorithm. First, we used a sliding window to extract linear and nonlinear features from both ECG and ACC signals. Then, we trained an extreme gradient boosting algorithm (XGBoost) to detect FBTCS according to seizure onset and offset annotated by three board-certified epileptologists. Finally, we applied a postprocessing step to regularize the classification output. A patientwise nested cross-validation was implemented to evaluate the performances in terms of sensitivity, false alarm rate (FAR), time in false warning (TiW), detection latency, and receiver operating characteristic area under the curve (ROC-AUC). RESULTS: We recorded 66 FBTCS from 42 patients who wore the connected shirt for a total of 8067 continuous hours. The XGBoost algorithm reached a sensitivity of 84.8% (56/66 seizures), with a median FAR of .55/24 h and a median TiW of 10 s/alarm. ROC-AUC was .90 (95% confidence interval = .88-.91). Median detection latency from the time of progression to the bilateral tonic-clonic phase was 25.5 s. SIGNIFICANCE: The novel connected shirt allowed accurate detection of FBTCS with a low false alarm rate in a hospital setting. Prospective studies in a residential setting with a real-time and online seizure detection algorithm are required to validate the performance and usability of this device.


Assuntos
Algoritmos , Eletroencefalografia , Convulsões , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Feminino , Adulto , Eletroencefalografia/métodos , Convulsões/diagnóstico , Convulsões/fisiopatologia , Pessoa de Meia-Idade , Adulto Jovem , Eletrocardiografia/métodos , Estudos Prospectivos , Adolescente , Aprendizado de Máquina , Acelerometria/métodos , Acelerometria/instrumentação , Epilepsia Tônico-Clônica/diagnóstico , Epilepsia Tônico-Clônica/fisiopatologia
2.
Brain Topogr ; 37(3): 461-474, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37823945

RESUMO

Preterm neonates are at risk of long-term neurodevelopmental impairments due to disruption of natural brain development. Electroencephalography (EEG) analysis can provide insights into brain development of preterm neonates. This study aims to explore the use of microstate (MS) analysis to evaluate global brain dynamics changes during maturation in preterm neonates with normal neurodevelopmental outcome.The dataset included 135 EEGs obtained from 48 neonates at varying postmenstrual ages (26.4 to 47.7 weeks), divided into four age groups. For each recording we extracted a 5-minute epoch during quiet sleep (QS) and during non-quiet sleep (NQS), resulting in eight groups (4 age group x 2 sleep states). We compared MS maps and corresponding (map-specific) MS metrics across groups using group-level maps. Additionally, we investigated individual map metrics.Four group-level MS maps accounted for approximately 70% of the global variance and showed non-random syntax. MS topographies and transitions changed significantly when neonates reached 37 weeks. For both sleep states and all MS maps, MS duration decreased and occurrence increased with age. The same relationships were found using individual maps, showing strong correlations (Pearson coefficients up to 0.74) between individual map metrics and post-menstrual age. Moreover, the Hurst exponent of the individual MS sequence decreased with age.The observed changes in MS metrics with age might reflect the development of the preterm brain, which is characterized by formation of neural networks. Therefore, MS analysis is a promising tool for monitoring preterm neonatal brain maturation, while our study can serve as a valuable reference for investigating EEGs of neonates with abnormal neurodevelopmental outcomes.


Assuntos
Encéfalo , Eletroencefalografia , Recém-Nascido , Humanos , Eletroencefalografia/métodos , Sono , Benchmarking , Idioma
3.
Sensors (Basel) ; 24(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39000904

RESUMO

This study aims to demonstrate the feasibility of using a new wireless electroencephalography (EEG)-electromyography (EMG) wearable approach to generate characteristic EEG-EMG mixed patterns with mouth movements in order to detect distinct movement patterns for severe speech impairments. This paper describes a method for detecting mouth movement based on a new signal processing technology suitable for sensor integration and machine learning applications. This paper examines the relationship between the mouth motion and the brainwave in an effort to develop nonverbal interfacing for people who have lost the ability to communicate, such as people with paralysis. A set of experiments were conducted to assess the efficacy of the proposed method for feature selection. It was determined that the classification of mouth movements was meaningful. EEG-EMG signals were also collected during silent mouthing of phonemes. A few-shot neural network was trained to classify the phonemes from the EEG-EMG signals, yielding classification accuracy of 95%. This technique in data collection and processing bioelectrical signals for phoneme recognition proves a promising avenue for future communication aids.


Assuntos
Eletroencefalografia , Eletromiografia , Processamento de Sinais Assistido por Computador , Tecnologia sem Fio , Humanos , Eletroencefalografia/métodos , Eletroencefalografia/instrumentação , Eletromiografia/métodos , Eletromiografia/instrumentação , Tecnologia sem Fio/instrumentação , Boca/fisiopatologia , Boca/fisiologia , Adulto , Masculino , Movimento/fisiologia , Redes Neurais de Computação , Distúrbios da Fala/diagnóstico , Distúrbios da Fala/fisiopatologia , Feminino , Dispositivos Eletrônicos Vestíveis , Aprendizado de Máquina
4.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257633

RESUMO

Electrooculography (EOG) serves as a widely employed technique for tracking saccadic eye movements in a diverse array of applications. These encompass the identification of various medical conditions and the development of interfaces facilitating human-computer interaction. Nonetheless, EOG signals are often met with skepticism due to the presence of multiple sources of noise interference. These sources include electroencephalography, electromyography linked to facial and extraocular muscle activity, electrical noise, signal artifacts, skin-electrode drifts, impedance fluctuations over time, and a host of associated challenges. Traditional methods of addressing these issues, such as bandpass filtering, have been frequently utilized to overcome these challenges but have the associated drawback of altering the inherent characteristics of EOG signals, encompassing their shape, magnitude, peak velocity, and duration, all of which are pivotal parameters in research studies. In prior work, several model-based adaptive denoising strategies have been introduced, incorporating mechanical and electrical model-based state estimators. However, these approaches are really complex and rely on brain and neural control models that have difficulty processing EOG signals in real time. In this present investigation, we introduce a real-time denoising method grounded in a constant velocity model, adopting a physics-based model-oriented approach. This approach is underpinned by the assumption that there exists a consistent rate of change in the cornea-retinal potential during saccadic movements. Empirical findings reveal that this approach remarkably preserves EOG saccade signals, resulting in a substantial enhancement of up to 29% in signal preservation during the denoising process when compared to alternative techniques, such as bandpass filters, constant acceleration models, and model-based fusion methods.


Assuntos
Aceleração , Movimentos Sacádicos , Humanos , Eletroculografia , Algoritmos , Encéfalo
5.
Sensors (Basel) ; 24(6)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38544106

RESUMO

Auscultation is a fundamental diagnostic technique that provides valuable diagnostic information about different parts of the body. With the increasing prevalence of digital stethoscopes and telehealth applications, there is a growing trend towards digitizing the capture of bodily sounds, thereby enabling subsequent analysis using machine learning algorithms. This study introduces the SonicGuard sensor, which is a multichannel acoustic sensor designed for long-term recordings of bodily sounds. We conducted a series of qualification tests, with a specific focus on bowel sounds ranging from controlled experimental environments to phantom measurements and real patient recordings. These tests demonstrate the effectiveness of the proposed sensor setup. The results show that the SonicGuard sensor is comparable to commercially available digital stethoscopes, which are considered the gold standard in the field. This development opens up possibilities for collecting and analyzing bodily sound datasets using machine learning techniques in the future.


Assuntos
Auscultação , Estetoscópios , Humanos , Som , Acústica , Algoritmos , Sons Respiratórios/diagnóstico
6.
Sensors (Basel) ; 24(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38475235

RESUMO

Algorithms for QRS detection are fundamental in the ECG interpretive processing chain. They must meet several challenges, such as high reliability, high temporal accuracy, high immunity to noise, and low computational complexity. Unfortunately, the accuracy expressed by missed or redundant events statistics is often the only parameter used to evaluate the detector's performance. In this paper, we first notice that statistics of true positive detections rely on researchers' arbitrary selection of time tolerance between QRS detector output and the database reference. Next, we propose a multidimensional algorithm evaluation method and present its use on four example QRS detectors. The dimensions are (a) influence of detection temporal tolerance, tested for values between 8.33 and 164 ms; (b) noise immunity, tested with an ECG signal with an added muscular noise pattern and signal-to-noise ratio to the effect of "no added noise", 15, 7, 3 dB; and (c) influence of QRS morphology, tested on the six most frequently represented morphology types in the MIT-BIH Arrhythmia Database. The multidimensional evaluation, as proposed in this paper, allows an in-depth comparison of QRS detection algorithms removing the limitations of existing one-dimensional methods. The method enables the assessment of the QRS detection algorithms according to the medical device application area and corresponding requirements of temporal accuracy, immunity to noise, and QRS morphology types. The analysis shows also that, for some algorithms, adding muscular noise to the ECG signal improves algorithm accuracy results.

7.
Sensors (Basel) ; 24(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39001027

RESUMO

Remote patient-monitoring systems are helpful since they can provide timely and effective healthcare facilities. Such online telemedicine is usually achieved with the help of sophisticated and advanced wearable sensor technologies. The modern type of wearable connected devices enable the monitoring of vital sign parameters such as: heart rate variability (HRV) also known as electrocardiogram (ECG), blood pressure (BLP), Respiratory rate and body temperature, blood pressure (BLP), respiratory rate, and body temperature. The ubiquitous problem of wearable devices is their power demand for signal transmission; such devices require frequent battery charging, which causes serious limitations to the continuous monitoring of vital data. To overcome this, the current study provides a primary report on collecting kinetic energy from daily human activities for monitoring vital human signs. The harvested energy is used to sustain the battery autonomy of wearable devices, which allows for a longer monitoring time of vital data. This study proposes a novel type of stress- or exercise-monitoring ECG device based on a microcontroller (PIC18F4550) and a Wi-Fi device (ESP8266), which is cost-effective and enables real-time monitoring of heart rate in the cloud during normal daily activities. In order to achieve both portability and maximum power, the harvester has a small structure and low friction. Neodymium magnets were chosen for their high magnetic strength, versatility, and compact size. Due to the non-linear magnetic force interaction of the magnets, the non-linear part of the dynamic equation has an inverse quadratic form. Electromechanical damping is considered in this study, and the quadratic non-linearity is approximated using MacLaurin expansion, which enables us to find the law of motion for general case studies using classical methods for dynamic equations and the suitable parameters for the harvester. The oscillations are enabled by applying an initial force, and there is a loss of energy due to the electromechanical damping. A typical numerical application is computed with Matlab 2015 software, and an ODE45 solver is used to verify the accuracy of the method.


Assuntos
Eletrocardiografia , Frequência Cardíaca , Dispositivos Eletrônicos Vestíveis , Frequência Cardíaca/fisiologia , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Eletrocardiografia/métodos , Eletrocardiografia/instrumentação , Fontes de Energia Elétrica , Internet das Coisas , Cinética , Telemedicina/instrumentação
8.
IEEE Sens J ; 23(9): 10140-10148, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38046935

RESUMO

Many prevalent heart diseases can be indicated by the features of the jugular venous pulse (JVP), an efficacious indicator of right heart health. However, JVP dynamics are not widely utilized in clinical settings as its observation and sensing remain cumbersome. Non-invasive measures of cardiac behavior, including the JVP, are of growing interest to enable continuous and at-home monitoring of cardiac disorders. In this work, we propose a wearable near-field radio-frequency (RF) sensor affixed with a neck collar on the clavicle over the internal jugular vein to enable non-invasive JVP sensing. We employed a complex vector injection signal processing method to extract repeatable JVP waveform features in multiple postures. With a 21-subject human study, we demonstrated morphologically consistent JVP sensing with consistent a-, c-, and v-wave feature timings, benchmarked by synchronous electrocardiogram and phonocardiogram. Further, inter-postural experiments demonstrated the capability of the proposed system to quantify morphological changes to the JVP which are present in many cardiac disorders. The results of this work suggest the proposed near-field RF sensor is capable of non-invasive JVP monitoring, potentially enabling improved sensing in both clinical and ambulatory environments.

9.
Sensors (Basel) ; 23(5)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36904670

RESUMO

Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz-frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 µs, while that of the LIDA algorithm was 189.9 ± 204.7 µs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low-well below one sample period for commonly acquired bioelectric signals.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Algoritmos
10.
Sensors (Basel) ; 23(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37571572

RESUMO

Wireless sensing systems are required for continuous health monitoring and data collection. It allows for patient data collection in real time rather than through time-consuming and expensive hospital or lab visits. This technology employs wearable sensors, signal processing, and wireless data transfer to remotely monitor patients' health. The research offers a novel approach to providing primary diagnostics remotely with a digital health system for monitoring pulmonary health status using a multimodal wireless sensor device. The technology uses a compact wearable with new integration of acoustics and biopotentials sensors to monitor cardiovascular and respiratory activity to provide comprehensive and fast health status monitoring. Furthermore, the small wearable sensor size may stick to human skin and record heart and lung activities to monitor respiratory health. This paper proposes a sensor data fusion method of lung sounds and cardiograms for potential real-time respiration pattern diagnostics, including respiratory episodes like low tidal volume and coughing. With a p-value of 0.003 for sound signals and 0.004 for electrocardiogram (ECG), preliminary tests demonstrated that it was possible to detect shallow breathing and coughing at a meaningful level.


Assuntos
Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Eletrocardiografia , Taxa Respiratória , Tecnologia sem Fio
11.
Chemometr Intell Lab Syst ; 230: 104680, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36213553

RESUMO

Although some people do not have any chronic disease or are not in the risky age group for Covid-19, they are more vulnerable to the coronavirus. As the reason for this situation, some experts focus on the immune system of the person, while others think that the genetic history of patients may play a role. It is critical to detect corona from DNA signals as early as possible to determine the relationship between Covid-19 and genes. Thus, the effect on the severe course of the disease of variations in the genes associated with the corona disease will be revealed. In this study, a novel intelligent computer approach is proposed to identify coronavirus from nucleotide signals for the first time. The proposed method presents a multilayered feature extraction structure to extract the most effective features using an Entropy-based mapping technique, Discrete Wavelet Transform (DWT), statistical feature extractor, and Singular Value Decomposition (SVD), together. Then 94 distinctive features are selected by the ReliefF technique. Support vector machine (SVM) and k nearest neighborhood (k-NN) are chosen as classifiers. The method achieved the highest classification accuracy rate of 98.84% with an SVM classifier to detect Covid-19 from DNA signals. The proposed method is ready to be tested with a different database in the diagnosis of Covid-19 using RNA or other signals.

12.
Adv Exp Med Biol ; 1384: 131-146, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36217082

RESUMO

The overnight polysomnography shows a range of drawbacks to diagnose obstructive sleep apnea (OSA) that have led to the search for artificial intelligence-based alternatives. Many classic machine learning methods have been already evaluated for this purpose. In this chapter, we show the main approaches found in the scientific literature along with the most used data to develop the models, useful and large easily available databases, and suitable methods to assess performances. In addition, a range of results from selected studies are presented as examples of these methods. Very high diagnostic performances are reported in these results regardless of the approaches taken. This leads us to conclude that conventional machine learning methods are useful techniques to develop new OSA diagnosis simplification proposals and to act as benchmark for other more recent methods such as deep learning.


Assuntos
Inteligência Artificial , Apneia Obstrutiva do Sono , Humanos , Aprendizado de Máquina , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico
13.
J Electrocardiol ; 75: 70-81, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35918202

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a disorder of the heart rhythm where irregular and rapid heartbeats are observed. This supraventricular arrhythmia may increase the risk of blood clots, stroke, heart failure, and other serious heart complications. Automatic analysis of AF that is based on machine learning (ML) plays an important role in detecting this heart disease. METHODS: A new approach for automated AF detection is presented using heart rate variability (HRV) features and machine learning. A set of time-domain, frequency-domain and nonlinear features are extracted from the R-R intervals. A new method for frequency-domain analysis of R-R intervals using the Fourier Decomposition Method is presented, which provides promising results as compared to the usual method of power spectral density estimation. We train the algorithm on the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) atrial fibrillation database and perform a comprehensive analysis using statistical tests to obtain the results without any intra-patient bias. RESULTS: The proposed method is able to achieve average result of 95.16% sensitivity, 92.46% specificity and 94.43% accuracy and its performance is better than the existing approaches. Furthermore, the efficacy of the proposed algorithm is tested on eight records from a previously unseen MIT-BIH Arrhythmia Database. CONCLUSION: This work shows that the proposed HRV features and ML approach can be effectively used for the analysis, detection, and classification of AF.


Assuntos
Fibrilação Atrial , Cardiopatias , Humanos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Fibrilação Atrial/diagnóstico , Algoritmos , Aprendizado de Máquina
14.
BMC Med Inform Decis Mak ; 22(1): 225, 2022 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36031620

RESUMO

BACKGROUND AND OBJECTIVE: The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times. METHODS: First, two recently developed algorithms were evaluated and optimized on 118 recordings of pulmonary vein IEGM taken from 35 patients undergoing ablation of persistent AF. The adaptive mathematical morphology algorithm (AMM) uses an adaptive structuring element to extract AAs based on their morphological features. The relative-energy algorithm (Rel-En) uses short- and long-term energies to enhance and detect the AAs in the IEGM signals. Second, following the AA extraction, the signal amplitude was weighted using statistics of the AA sequences in order to reduce over- and undersensing of the algorithms. The detection capacity of our algorithms was compared with manually annotated activations and with two previously developed algorithms based on the Teager-Kaiser energy operator and the AF cycle length iteration, respectively. Finally, a method based on the barycenter was developed to reduce artificial variations in the activation annotations of complex IEGM signals. RESULTS: The best detection was achieved using Rel-En, yielding a false negative rate of 0.76% and a false positive rate of only 0.12% (total error rate 0.88%) against expert annotation. The post-processing further reduced the total error rate of the Rel-En algorithm by 70% (yielding to a final total error rate of 0.28%). CONCLUSION: The proposed method shows reliable detection and robust temporal annotation of AAs recorded within pulmonary veins in AF. The method has low computational cost and high robustness for automatic detection of AAs, which makes it a suitable approach for online use in a procedural context.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Humanos
15.
J Emerg Med ; 63(1): 115-129, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35940984

RESUMO

BACKGROUND: Contactless vital signs (VS) measurement with video photoplethysmography (vPPG), motion analysis (MA), and passive infrared thermometry (pIR) has shown promise. OBJECTIVES: To compare conventional (contact-based) and experimental contactless VS measurement approaches for emergency department (ED) walk-in triage in pandemic conditions. METHODS: Patients' heart rates (HR), respiratory rates (RR), and temperatures were measured with cardiorespiratory monitor and vPPG, manual count and MA, and contact thermometers and pIR, respectively. RESULTS: There were 475 walk-in ED patients studied (95% of eligible). Subjects were 35.2 ± 20.8 years old (range 4 days‒95 years); 52% female, 0.2% transgender; had Fitzpatrick skin type of 2.3 ± 1.4 (range 1‒6), Emergency Severity Index of 3.0 ± 0.6 (range 2‒5), and contact temperature of 36.83°C (range 35.89-39.4°C) (98.3°F [96.6‒103°F]). Pediatric HR and RR data were excluded from analysis due to research challenges associated with pandemic workflow. For a 30-s, unprimed "Triage" window in 377 adult patients, vPPG-MA acquired 377 (100%) HR measurements featuring a mean difference with cardiorespiratory monitor HR of 5.9 ± 12.8 beats/min (R = 0.6833) and 252 (66.8%) RR measurements featuring a mean difference with manual RR of -0.4 ± 2.6 beats/min (R = 0.8128). Subjects' Emergency Severity Index components based on conventional VS and contactless VS matched for 83.8% (HR) and 89.3% (RR). Filtering out vPPG-MA measurements with low algorithmic confidence reduced VS acquired while improving correlation with conventional measurements. The mean difference between contact and pIR temperatures was 0.83 ± 0.67°C (range -1.16-3.5°C) (1.5 ± 1.2°F [range -2.1-6.3°F]); pIR fever detection improved with post hoc adjustment for mean bias. CONCLUSION: Contactless VS acquisition demonstrated good agreement with contact methods during adult walk-in ED patient triage in pandemic conditions; clinical applications will need further study.


Assuntos
Serviço Hospitalar de Emergência , Pandemias , Fotopletismografia , Termografia , Triagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Determinação da Frequência Cardíaca/métodos , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Fotopletismografia/métodos , Taxa Respiratória , Termografia/métodos , Triagem/métodos , Sinais Vitais , Adulto Jovem
16.
Sensors (Basel) ; 22(24)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36559937

RESUMO

Heart sounds convey important information regarding potential heart diseases. Currently, heart sound classification attracts many researchers from the fields of telemedicine, digital signal processing, and machine learning-among others-mainly to identify cardiac pathology as quickly as possible. This article proposes chaogram as a new transform to convert heart sound signals to colour images. In the proposed approach, the output image is, therefore, the projection of the reconstructed phase space representation of the phonocardiogram (PCG) signal on three coordinate planes. This has two major benefits: (1) it makes possible to apply deep convolutional neural networks to heart sounds and (2) it is also possible to employ a transfer learning scheme by converting a heart sound signal to an image. The performance of the proposed approach was verified on the PhysioNet dataset. Due to the imbalanced data on this dataset, it is common to assess the results quality using the average of sensitivity and specificity, which is known as score, instead of accuracy. In this study, the best results were achieved using the InceptionV3 model, which achieved a score of 88.06%.


Assuntos
Cardiopatias , Ruídos Cardíacos , Humanos , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Aprendizado de Máquina
17.
Sensors (Basel) ; 22(18)2022 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-36146394

RESUMO

Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts pulse rate variability (PRV). This study aims to identify the nature of such artifacts caused by various types of factors under the conditions of precisely planned experiments. We also propose methods for their reduction based solely on the PPG signal while preserving the frequency content of PRV. The accuracy of PRV derived from PPG was compared to heart rate variability (HRV) derived from the accompanying ECG. The results indicate that filtering PPG signals using the discrete wavelet transform and its inverse (DWT/IDWT) is suitable for removing slow components and high-frequency noise. Moreover, the main benefit of amplitude demodulation is better preparation of the PPG to determine the duration of pulse cycles and reduce the impact of some other artifacts. Post-processing applied to HRV and PRV indicates that the correction of outliers based on local statistical measures of signals and the autoregressive (AR) model is only important when the PPG is of low quality and has no effect under good signal quality. The main conclusion is that the DWT/IDWT, followed by amplitude demodulation, enables the proper preparation of the PPG signal for the subsequent use of PRV extraction algorithms, particularly at rest. However, post-processing in the proposed form should be applied more in the situations of observed strong artifacts than in motionless laboratory experiments.


Assuntos
Fotopletismografia , Processamento de Sinais Assistido por Computador , Algoritmos , Artefatos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Análise de Ondaletas
18.
Sensors (Basel) ; 22(19)2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36236265

RESUMO

Label noise is omnipresent in the annotations process and has an impact on supervised learning algorithms. This work focuses on the impact of label noise on the performance of learning models by examining the effect of random and class-dependent label noise on a binary classification task: quality assessment for photoplethysmography (PPG). PPG signal is used to detect physiological changes and its quality can have a significant impact on the subsequent tasks, which makes PPG quality assessment a particularly good target for examining the impact of label noise in the field of biomedicine. Random and class-dependent label noise was introduced separately into the training set to emulate the errors associated with fatigue and bias in labeling data samples. We also tested different representations of the PPG, including features defined by domain experts, 1D raw signal and 2D image. Three different classifiers are tested on the noisy training data, including support vector machine (SVM), XGBoost, 1D Resnet and 2D Resnet, which handle three representations, respectively. The results showed that the two deep learning models were more robust than the two traditional machine learning models for both the random and class-dependent label noise. From the representation perspective, the 2D image shows better robustness compared to the 1D raw signal. The logits from three classifiers are also analyzed, the predicted probabilities intend to be more dispersed when more label noise is introduced. From this work, we investigated various factors related to label noise, including representations, label noise type, and data imbalance, which can be a good guidebook for designing more robust methods for label noise in future work.


Assuntos
Fotopletismografia , Máquina de Vetores de Suporte , Algoritmos , Aprendizado de Máquina , Fotopletismografia/métodos
19.
Sensors (Basel) ; 22(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35270853

RESUMO

The impact of neurodegenerative disorders is twofold; they affect both quality of life and healthcare expenditure. In the case of Parkinson's disease, several strategies have been attempted to support the pharmacological treatment with rehabilitation protocols aimed at restoring motor function. In this scenario, the study of upper limb control mechanisms is particularly relevant due to the complexity of the joints involved in the movement of the arm. For these reasons, it is difficult to define proper indicators of the rehabilitation outcome. In this work, we propose a methodology to analyze and extract an ensemble of kinematic parameters from signals acquired during a complex upper limb reaching task. The methodology is tested in both healthy subjects and Parkinson's disease patients (N = 12), and a statistical analysis is carried out to establish the value of the extracted kinematic features in distinguishing between the two groups under study. The parameters with the greatest number of significances across the submovements are duration, mean velocity, maximum velocity, maximum acceleration, and smoothness. Results allowed the identification of a subset of significant kinematic parameters that could serve as a proof-of-concept for a future definition of potential indicators of the rehabilitation outcome in Parkinson's disease.


Assuntos
Doença de Parkinson , Acidente Vascular Cerebral , Fenômenos Biomecânicos , Humanos , Qualidade de Vida , Extremidade Superior
20.
Sensors (Basel) ; 22(17)2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36080785

RESUMO

The HeartPy Python toolkit for analysis of noisy signals from heart rate measurements is an excellent tool to use in conjunction with novel wearable sensors. Nevertheless, most of the work to date has focused on applying the toolkit to data measured with commercially available sensors. We demonstrate the application of the HeartPy functions to data obtained with a novel graphene-based heartbeat sensor. We produce the sensor by laser-inducing graphene on a flexible polyimide substrate. Both graphene on the polyimide substrate and graphene transferred onto a PDMS substrate show piezoresistive behavior that can be utilized to measure human heartbeat by registering median cubital vein motion during blood pumping. We process electrical resistance data from the graphene sensor using HeartPy and demonstrate extraction of several heartbeat parameters, in agreement with measurements taken with independent reference sensors. We compare the quality of the heartbeat signal from graphene on different substrates, demonstrating that in all cases the device yields results consistent with reference sensors. Our work is a first demonstration of successful application of HeartPy to analysis of data from a sensor in development.


Assuntos
Grafite , Dispositivos Eletrônicos Vestíveis , Frequência Cardíaca , Humanos , Lasers , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA