Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.319
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094916

RESUMO

BACKGROUND AND AIMS: Video capsule endoscopy (VCE) is valuable for assessing conditions like gastrointestinal bleeding, anemia, and inflammatory bowel disease. Glucagon-like peptide-1 receptor agonists (GLP-1 RA) are prescribed for diabetes and weight loss, with their pharmacologic effects including delaying gastric emptying. This study investigates the impact of GLP-1 RA usage on VCE outcomes in patients with diabetes. METHODS: This retrospective cohort study involves patients with diabetes undergoing VCE while on GLP-1 RA, matched 1:1 ratio with controls based on demographics and diabetes related factors, who are not on GLP-RA. The primary outcome is gastric transit time in VCE studies, with secondary outcome being incomplete small bowel evaluation and the small bowel transit time. RESULTS: In the 68 GLP-1 RA patient cohort, five (7%) experienced VCE failure to pass through the stomach, while all controls passed successfully (p=0.06). GLP-1 RA patients had longer gastric transit time (99.3 ± 134.2 minutes) compared to controls (25.3 ± 31.6 minutes, p <0.001). Multivariate analysis revealed GLP-1 RA usage was associated with increased gastric transit time by 74.5 minutes (CI: 33.8-115.2, p <0.001) compared to controls, after adjusting on relevant factors. Sixteen GLP-1 RA patients (23.5%) experienced incomplete passage of the VCE through the small intestine, a significantly higher rate compared to three patients in the control group (4.4%) (p<0.01). CONCLUSIONS: GLP-1 RA usage is associated with prolonged gastric transit time and a higher rate of incomplete small bowel evaluation during VCE. Future studies may be crucial for evaluating strategies to mitigate these effects.

2.
Gastrointest Endosc ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048039

RESUMO

BACKGROUND AND AIMS: Current guidelines recommend bowel preparation before small-bowel capsule endoscopy (SBCE). However, the optimal protocol is yet to be defined. To determine the best timing for preparation in SBCE, we compared small-bowel visualization quality (SBVQ), diagnostic yield (DY), and patient-reported outcomes across four purgative regimens. METHODS: In this prospective, randomized (1:1:1:1), multicentric study, patients with suspected small bowel bleeding were randomized into four arms: G1 (1L of polyethylene-glycol + ascorbic acid [Moviprep®] the night before SBCE), G2 (1L in the morning, up to 2 hours before SBCE), G3 (0.5L up to 2 hours before + 0.5L after the capsule reached the duodenum), and G4 (1L after reaching the duodenum). To assess DY, lesions were categorized as having high (P2) or low (P0 or P1) bleeding potential. Small-bowel visualization quality (SBVQ) was assessed using the Brotz score. Transit times (TT) were measured, and patient tolerability was scored from 0 to 5 with higher scores indicating better tolerability. RESULTS: A total of 387 patients were included; 59% female with a median age of 73 years (IQR 23). The exam completion rate was lower in G1 (90%, p<0.001). Small bowel TT was shorter for patients receiving purgative during SBCE (G3 and G4, p=0.001). SBVQ was better in patients receiving purgative after reaching the SB (p<0.001): median of 7 for G1, 8 for G2, and 9 for G3 and G4. The overall DY of patients receiving intra-procedure purgatives (G3 + G4) was superior (42.7 vs 31.3%, p=0.02); significant differences were found in the second and third terciles. Likewise, G3 and G4 had higher angioectasia detection (p=0.04). Patients' satisfaction was significantly superior for G4 (median 4 points, IQR 1). CONCLUSIONS: The group that received the bowel preparation the night before SBCE had poorer outcomes. Intra-procedure purgative regimens reduced SBTT, enhanced visualization, improved DY, and increased angioectasia detection. G4 was the best-tolerated regimen.

3.
Gastrointest Endosc ; 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39111392

RESUMO

BACKGROUND AND AIMS: Many gastrointestinal (GI) disorders and precancerous conditions often present asymptomatically, leading to delayed patient diagnoses and treatment interventions. This study aimed to develop a novel cable-transmission magnetically controlled capsule endoscopy (CT-MCCE) system for detecting GI diseases and assess its safety and feasibility through clinical trials. METHODS: This prospective, multicenter, trial compared CT-MCCE with conventional gastroscopy in patients aged 18-75 years with upper GI diseases between October 2022 and May 2023. The primary endpoints included the evaluation of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) in the detection of focal lesions within the esophagus, stomach, and duodenal bulb using CT-MCCE. RESULTS: A total of 180 individuals (mean age: 43.1 years, 52.22% female) were recruited from three hospitals in China. CT-MCCE detected lesions in esophagus with 97.22% sensitivity, 100% specificity, a PPV of 100%, a NPV of 98.18%, and 98.89% accuracy. CT-MCCE detected gastric focal lesions in the whole stomach with 96.81% sensitivity, 98.84% specificity, a PPV of 98.91%, a NPV of 96.59%, and 97.78% accuracy. CT-MCCE detected lesions in the duodenal bulb with 100% sensitivity, 100% specificity, a PPV of 100%, a NPV of 100%, and 100% accuracy. There were no significant differences between CT-MCCE and EGD regarding the cleanliness of the upper GI tract and visibility of the upper GI mucosa. However, CT-MCCE was associated with a lower incidence of discomfort than EGD (P<0.001). CONCLUSIONS: The diagnostic performance of CT-MCCE is comparable to that of EGD in the completion of upper GI tract examinations and lesion detection. Furthermore, the improved tolerance of CT-MCCE in detecting upper GI diseases was noted without any observed adverse events.

4.
BMC Gastroenterol ; 24(1): 80, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388860

RESUMO

OBJECTIVES: Poorly visualized images that appear during small bowel capsule endoscopy (SBCE) can confuse the interpretation of small bowel lesions and increase the physician's workload. Using a validated artificial intelligence (AI) algorithm that can evaluate the mucosal visualization, we aimed to assess whether SBCE reading after the removal of poorly visualized images could affect the diagnosis of SBCE. METHODS: A study was conducted to analyze 90 SBCE cases in which a small bowel examination was completed. Two experienced endoscopists alternately performed two types of readings. They used the AI algorithm to remove poorly visualized images for the frame reduction reading (AI user group) and conducted whole frame reading without AI (AI non-user group) for the same patient. A poorly visualized image was defined as an image with < 50% mucosal visualization. The study outcomes were diagnostic concordance and reading time between the two groups. The SBCE diagnosis was classified as Crohn's disease, bleeding, polyp, angiodysplasia, and nonspecific finding. RESULTS: The final SBCE diagnoses between the two groups showed statistically significant diagnostic concordance (k = 0.954, p < 0.001). The mean number of lesion images was 3008.5 ± 9964.9 in the AI non-user group and 1401.7 ± 4811.3 in the AI user group. There were no cases in which lesions were completely removed. Compared with the AI non-user group (120.9 min), the reading time was reduced by 35.6% in the AI user group (77.9 min). CONCLUSIONS: SBCE reading after reducing poorly visualized frames using the AI algorithm did not have a negative effect on the final diagnosis. SBCE reading method integrated with frame reduction and mucosal visualization evaluation will help improve AI-assisted SBCE interpretation.


Assuntos
Endoscopia por Cápsula , Doenças do Colo , Doença de Crohn , Humanos , Inteligência Artificial , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Estudos Retrospectivos
5.
J Pediatr Gastroenterol Nutr ; 78(2): 280-288, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38374550

RESUMO

OBJECTIVES: Ulcerative colitis (UC) is a chronic inflammatory bowel disease (IBD) often requiring endoscopic evaluations, which can be uncomfortable and costly, especially for children. This study aimed to evaluate the diagnostic accuracy of a noninvasive approach combining fecal calprotectin (FCP), colonic ultrasonography (US), and colon capsule endoscopy (CCE) compared with standard ileocolonoscopy in pediatric UC. METHODS: UC children were enrolled and underwent FCP and US on Day 0, followed by CCE on Day 1 and ileocolonoscopy on Day 2. All procedures were performed by operators who were blinded to the patient's clinical history and all test results. The accuracy for disease activity and extension of each technique and their combination was assessed and compared. Tolerability and safety were also evaluated. RESULTS: Thirty-two patients were enrolled (15 males, mean age 13.2 ± 3.2 years). CCE showed a sensitivity of 95% and specificity of 100% in detecting colonic inflammation, with positive predictive value (PPV) and negative predictive value (NPV) of 100% and 92%, respectively. US demonstrated a sensitivity of 85% and specificity of 92%, with PPV and NPV of 94% and 79%. The combination of FCP, US, and CCE achieved 95% sensitivity and 100% specificity, with PPV of 100% and NPV of 92%. The noninvasive approach was better tolerated than colonoscopy (p < 0.05), and no serious adverse events were reported. CONCLUSION: The noninvasive approach combining fecal calprotectin (FCP), ultrasonography, and colon capsule endoscopy demonstrated high diagnostic accuracy and better tolerability compared with standard ileocolonoscopy in pediatric ulcerative colitis follow-up. Further multicenter studies are needed to confirm these findings and evaluate the reproducibility of this noninvasive approach.


Assuntos
Colite Ulcerativa , Masculino , Criança , Humanos , Adolescente , Colite Ulcerativa/diagnóstico por imagem , Estudos Prospectivos , Seguimentos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Colonoscopia/métodos , Fezes , Complexo Antígeno L1 Leucocitário , Biomarcadores
6.
J Gastroenterol Hepatol ; 39(1): 165-171, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37837361

RESUMO

BACKGROUND AND AIM: Although small-bowel capsule endoscopy (CE) is widely used for obscure gastrointestinal bleeding (OGIB), long-term outcomes for OGIB patients after negative CE remain unclear. Herein, we defined negative CE as P0 (no bleeding potential) or P1 (less likely to bleed), based on the P classification using CE. We aimed to clarify long-term outcomes of patients with OGIB after negative CE. METHODS: This single-center observational study enrolled 461 consecutive patients with OGIB who underwent CE from March 2014 to October 2021 and were followed up for >1 year. We examined rebleeding rates and predictive factors. RESULTS: Two hundred and twenty-four (49%) patients had P0, and 237 (51%) had P1 findings. Rebleeding occurred in 9% and 16% of patients in the P0 and P1 groups, respectively. Two patients in the P0 group and 15 in the P1 group showed rebleeding from the small bowel. The rate of small-bowel rebleeding was significantly lower in the P0 group than that in the P1 group (1% vs 6%, P = 0.002), as was the cumulative rebleeding rate (P = 0.004). In the multivariate analysis, history of endoscopic hemostasis (hazard ratio [HR] = 15.958, 95% confidence interval [CI]:4.950-51.447, P < 0.001) and P1 CE findings (HR = 9.989, 95% CI: 2.077-48.030, P = 0.004) were independently predicted small-bowel rebleeding. CONCLUSIONS: OGIB with P0 CE findings rarely showed rebleeding from the small bowel. Rebleeding may occur in patients with OGIB. Patients with history of endoscopic hemostasis for small-bowel lesions or P1 CE findings should be followed up intensively.


Assuntos
Endoscopia por Cápsula , Hemostase Endoscópica , Humanos , Endoscopia por Cápsula/efeitos adversos , Recidiva , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Fatores de Tempo , Estudos Retrospectivos , Endoscopia Gastrointestinal
7.
J Gastroenterol Hepatol ; 39(1): 157-164, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37830487

RESUMO

BACKGROUND AND AIM: Convolutional neural network (CNN) systems that automatically detect abnormalities from small-bowel capsule endoscopy (SBCE) images are still experimental, and no studies have directly compared the clinical usefulness of different systems. We compared endoscopist readings using an existing and a novel CNN system in a real-world SBCE setting. METHODS: Thirty-six complete SBCE videos, including 43 abnormal lesions (18 mucosal breaks, 8 angioectasia, and 17 protruding lesions), were retrospectively prepared. Three reading processes were compared: (A) endoscopist readings without CNN screening, (B) endoscopist readings after an existing CNN screening, and (C) endoscopist readings after a novel CNN screening. RESULTS: The mean number of small-bowel images was 14 747 per patient. Among these images, existing and novel CNN systems automatically captured 24.3% and 9.4% of the images, respectively. In this process, both systems extracted all 43 abnormal lesions. Next, we focused on the clinical usefulness. The detection rates of abnormalities by trainee endoscopists were not significantly different across the three processes: A, 77%; B, 67%; and C, 79%. The mean reading time of the trainees was the shortest during process C (10.1 min per patient), followed by processes B (23.1 min per patient) and A (33.6 min per patient). The mean psychological stress score while reading videos (scale, 1-5) was the lowest in process C (1.8) but was not significantly different between processes B (2.8) and A (3.2). CONCLUSIONS: Our novel CNN system significantly reduced endoscopist reading time and psychological stress while maintaining the detectability of abnormalities. CNN performance directly affects clinical utility and should be carefully assessed.


Assuntos
Endoscopia por Cápsula , Aprendizado Profundo , Humanos , Endoscopia por Cápsula/métodos , Estudos Retrospectivos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Redes Neurais de Computação
8.
Pediatr Transplant ; 28(2): e14732, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38433619

RESUMO

BACKGROUND: Neuroendocrine tumors (NETs) are rare epithelial neoplasms that arise most commonly from the gastrointestinal tract. In pediatrics, the most common site of origin is in the appendix, with the liver being the most common site of metastasis. Neuroendocrine tumors arising from the biliary tract are extremely rare. METHODS: We describe a case of a nine-year-old girl who presented with obstructive cholestasis and was found to have multiple liver masses identified on biopsy as well-differentiated neuroendocrine tumor with an unknown primary tumor site. RESULT: The patient underwent extensive investigation to identify a primary tumor site, including endoscopy, endoscopic ultrasound, and capsule endoscopy. The patient ultimately underwent definitive management with liver transplant, and on explant was discovered to have multiple well-differentiated neuroendocrine tumors, WHO Grade 1, with extensive infiltration into the submucosa of bile duct, consistent with primary biliary tract neuroendocrine tumor. CONCLUSION: Identifying the site of the primary tumor in NETs found within the liver can be challenging. To determine if an extrahepatic primary tumor exists, workup should include endoscopy, EUS, and capsule endoscopy. Children with well-differentiated hepatic NETs, with no identifiable primary tumor, and an unresectable tumor, are considered favorable candidates for liver transplantation.


Assuntos
Sistema Biliar , Transplante de Fígado , Tumores Neuroendócrinos , Feminino , Humanos , Criança , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/cirurgia , Fígado , Ductos Biliares
9.
Digestion ; : 1-7, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857573

RESUMO

INTRODUCTION: Patients with Crohn's disease (CD) require an assessment of small bowel lesions, while difficulties exist in performing small intestinal examinations, especially in small-sized medical offices. Small bowel capsule endoscopy (SBCE) is handy and can be performed in most clinical settings. The only drawback of SBCE is a requirement of patency testing prior to the exam because it sometimes requires CT scanning to localize the ingested patency capsule (PC), which may be a substantial burden for the patient. We have developed a novel PC detection system named PICS (patency capsule, ileocolonoscopy, and small bowel capsule endoscopy) method by which we can avoid CT scanning. In the PICS method, ileocolonoscopy (ICS) is performed after 30-33 h of PC ingestion and the PC can be localized by ICS in patients who have not excreted the PC, and the entire intestine can be examined in combination with subsequent SBCE without additional bowel preparation. The aim of this study was to assess the usefulness and safety of the PICS method for CD patients. METHODS: CD patients who underwent PICS method from April 2021 to March 2023 were reviewed for clinical data, outcome of PICS method including the rates of PC detection by ICS, the number of patients underwent SBCE, and adverse events. Lewis score was used to assess SBCE results. RESULTS: The PICS method was performed in 54 patients. The median age of patients was 28.5 years old, and 64.8% of them were ileocolic type. The median disease duration was 10.5 months and 24.1% had history of small bowel resection. Five cases (9.3%) confirmed gastrointestinal patency by ICS, and none of the cases required CT scanning. One patient who could not be confirmed patency by ICS, and the other patient who excreted PC but was found ileal stenosis by ICS did not undergo SBCE. Remaining 52 patients received SBCE, and the median Lewis score of them was 0 (IQR 0, 450). There were no adverse events including small bowel obstruction by PC and SBCE retention in this series. CONCLUSION: The PICS method is not only feasible and safe but also convenient to assess disease extent in patients with CD. By localizing PC with ICS, additional CT scanning could be unnecessary for SBCE, which benefits both physicians and CD patients.

10.
Digestion ; : 1, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857583

RESUMO

INTRODUCTION: Crohn's disease (CD) induces persistent inflammation throughout the gastrointestinal (GI) tract, potentially resulting in complications such as intestinal stenosis and fistulas, particularly in the small bowel. Small bowel capsule endoscopy (SBCE) is recommended for monitoring CD, especially when GI tract patency is maintained. This study aimed to retrospectively assess patients with CD who underwent SBCE to determine the timing of clinical changes and address the current lack of evidence regarding GI tract patency loss during CD treatment. METHODS: Of the 166 consecutive patients who underwent SBCE at our institution, 120 were followed up and included in this study. Forty-six patients were excluded due to colitis type or immediate treatment changes post-SBCE. This study focused on the primary and secondary endpoints, including the cumulative stricture-free rate of the GI tract, emergency hospitalization post-SBCE, and post-SBCE treatment strategies, at the discretion of the attending physicians. RESULTS: Demographic data revealed that the mean age of the study population was 43 years and that there was a male predominance (75%). The median disease duration was 12 years and the mean Crohn's Disease Activity Index was 98. During a 1,486-day observation period, 37% of patients experienced treatment changes. A Lewis score of >264 and perianal lesions were identified as independent risk factors for additional treatment needs. Emergency hospitalization occurred in 6% of patients and GI patency failure in 11%. Female sex and Lewis score>264 were associated with higher risks. GI patency rate declined 2 years after SBCE. CONCLUSIONS: For patients who experienced no treatment changes based on SBCE results, it is recommended to undergo SBCE monitoring at intervals of no longer than 2 years.

11.
Dig Dis Sci ; 69(6): 2140-2146, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38637455

RESUMO

BACKGROUND AND AIMS: Small bowel gastrointestinal bleeding (GIB) is associated with multiple blood transfusions, prolonged and/or multiple hospital admissions, utilization of significant healthcare resources, and negative effects on patient quality of life. There is a well-recognized association between antithrombotic medications and small bowel GIB. We aimed to identify the diagnostic yield of small bowel capsule endoscopy (SBCE) in patients on antithrombotic medications and the impact of SBCE on treatment course. METHODS: The electronic medical records of nineteen hundred eighty-six patients undergoing SBCE were retrospectively reviewed. RESULTS: The diagnostic yield for detecting stigmata of recent bleeding and/or actively bleeding lesions in SBCE was higher in patients that were on antiplatelet agents (21.6%), patients on anticoagulation (22.5%), and in patients that had their SBCE performed while they were inpatient (21.8%), when compared to the patients not on antiplatelet agents (12.1%), patients not on anticoagulation (13.5%), and with patients that had their SBCE performed in the outpatient setting (12%). Of 318 patients who had stigmata of recent bleeding and/or actively bleeding lesion(s) identified on SBCE, SBCE findings prompted endoscopic evaluation (small bowel enteroscopy, esophagogastroduodenoscopy (EGD), and/or colonoscopy) in 25.2%, with endoscopic hemostasis attempted in 52.5%. CONCLUSIONS: Our study, the largest conducted to date, emphasizes the importance of performing SBCE as part of the evaluation for suspected small bowel bleeding, particularly in patients taking antithrombotic therapy, and especially during their inpatient hospital stay.


Assuntos
Endoscopia por Cápsula , Fibrinolíticos , Hemorragia Gastrointestinal , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Intestino Delgado/patologia , Intestino Delgado/diagnóstico por imagem , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/efeitos adversos , Idoso de 80 Anos ou mais
12.
Dig Dis Sci ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940976

RESUMO

BACKGROUND: A GI hospitalist (GIH) is a physician who practices in the inpatient setting performing consultations and endoscopic procedures. Obscure small bowel bleeding is a common inpatient diagnosis that is difficult to manage and associated with longer hospitalizations. Having an onsite GIH physician with expertise in video capsule endoscopy (VCE) and double-balloon enteroscopy (DBE) has the potential to improve patient outcomes. AIMS: This study will be the first to explore how implementing a GIH model and providing a GIH with training in DBE can affect the outcomes of patients with small bowel pathology. METHODS: We performed a retrospective study of patients who received an inpatient DBE at an academic medical center before and after initiation of a GIH model and credentialing of a GIH in DBE. We compared outcomes, including procedure volumes, diagnostic and therapeutic yields, procedure duration, time to procedure, and length of stay. RESULTS: There was a 46.5% increase in the number of DBEs performed by the GIH. The diagnostic yield increased from 56.3 to 74.0% (OR 2.2, 95% CI 1.2-4.2), and the proportion of DBEs with a therapeutic intervention increased from 38.0 to 65.4% (OR 3.1, 95% CI 1.4-7.0). The total procedure time increased from 77.8 to 96.4 min (p < 0.05) with a GIH. CONCLUSION: Having a GIH perform inpatient DBEs was associated with an increased number of procedures, duration of procedures, diagnostic yield, and therapeutic interventions. The onsite presence of a GIH with competency in DBE improves the care of hospitalized patients with small bowel pathology.

13.
Intern Med J ; 54(8): 1369-1375, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38567663

RESUMO

BACKGROUND: Small bowel capsule endoscopy (SBCE) and device-assisted enteroscopy (DAE) have an established role in the investigation and management of small bowel pathology. Previous studies have reported on the yield of SBCE (60%) and DAE (57%), but none have been in an Australian setting. AIMS: To determine the yield of SBCE and any DAE performed as a direct consequence of SBCE in an Australian referral centre. METHODS: A single-centre retrospective study was conducted at a tertiary hospital in Australia, enrolling consecutive patients between 1 January 2009 and 31 December 2021 undergoing SBCE. Data were collected with respect to demographics, procedural factors and findings, as well as findings and interventions of any DAE procedures performed after the SBCE. RESULTS: 1214 SBCEs were performed, with a median age of 66 years old (60.8% men). The predominant indications were anaemia (n = 853, 70.2%) and overt gastrointestinal bleeding (n = 320, 26.4%). Of the complete small bowel studies (1132/1214, 93.2%), abnormal findings were detected in 588 cases (51.9%), most commonly angioectasias (266/588, 45.2%), erosions (106/588, 18.0%) and ulcers (97/588, 8.6%). 165 patients underwent a DAE (117 antegrade, 48 retrograde). Antegrade DAE had a higher yield than retrograde DAE (77.8% vs 54.2%; P = 0.002) and a higher rate of intervention (69.2% vs 37.5%; P < 0.001). CONCLUSION: In this largest single-centre cohort of patients undergoing SBCE to date, there is a similar yield of abnormal findings compared to existing literature. DAE, especially with an antegrade approach, had high diagnostic and therapeutic yield when pursued after a positive SBCE study.


Assuntos
Endoscopia por Cápsula , Hemorragia Gastrointestinal , Intestino Delgado , Centros de Atenção Terciária , Humanos , Masculino , Feminino , Estudos Retrospectivos , Endoscopia por Cápsula/métodos , Idoso , Pessoa de Meia-Idade , Austrália , Intestino Delgado/diagnóstico por imagem , Idoso de 80 Anos ou mais , Adulto , Enteropatias/diagnóstico , Enteropatias/diagnóstico por imagem , Adulto Jovem
14.
Dig Endosc ; 36(4): 437-445, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37612137

RESUMO

OBJECTIVES: Although several studies have shown the usefulness of artificial intelligence to identify abnormalities in small-bowel capsule endoscopy (SBCE) images, few studies have proven its actual clinical usefulness. Thus, the aim of this study was to examine whether meaningful findings could be obtained when negative SBCE videos were reanalyzed with a deep convolutional neural network (CNN) model. METHODS: Clinical data of patients who received SBCE for suspected small-bowel bleeding at two academic hospitals between February 2018 and July 2020 were retrospectively collected. All SBCE videos read as negative were reanalyzed with the CNN algorithm developed in our previous study. Meaningful findings such as angioectasias and ulcers were finally decided after reviewing CNN-selected images by two gastroenterologists. RESULTS: Among 202 SBCE videos, 103 (51.0%) were read as negative by humans. Meaningful findings were detected in 63 (61.2%) of these 103 videos after reanalyzing them with the CNN model. There were 79 red spots or angioectasias in 40 videos and 66 erosions or ulcers in 35 videos. After reanalysis, the diagnosis was changed for 10 (10.3%) patients who had initially negative SBCE results. During a mean follow-up of 16.5 months, rebleeding occurred in 19 (18.4%) patients. The rebleeding rate was 23.6% (13/55) for patients with meaningful findings and 16.1% (5/31) for patients without meaningful findings (P = 0.411). CONCLUSION: Our CNN algorithm detected meaningful findings in negative SBCE videos that were missed by humans. The use of deep CNN for SBCE image reading is expected to compensate for human error.


Assuntos
Endoscopia por Cápsula , Aprendizado Profundo , Humanos , Endoscopia por Cápsula/métodos , Inteligência Artificial , Estudos Retrospectivos , Úlcera
15.
J Formos Med Assoc ; 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38880710

RESUMO

BACKGROUND PURPOSE: Capsule endoscopy (CE) is a noninvasive examination for excellent visualization of small bowel mucosal lesions. We aimed to evaluate the clinical efficacy and safety of CE in pediatric patients. METHODS: From April 2014 to December 2022, CE procedures performed in children younger than 18 years of age at Taichung Veteran General Hospital were analyzed retrospectively. RESULTS: Among 136 procedures, the completion rate was 95.6% (n = 130), with a median age of 14 years old. Suspicion or evaluation of inflammatory bowel diseases (IBD) (41%) was the most common indication for CE. Other common indications of CE were chronic unexplained abdominal pain (35%) and obscure gastrointestinal bleeding or iron deficiency anemia (21%). No procedure-related complications occurred. The diagnosis of those patients with incomplete study were CD with small bowel stricture, graft-versus-host disease and duodenal ulcers. A total of 86 CE procedures showed positive findings, and the overall diagnostic yield rate was 63.2%. Small bowel ulcers (65.12%) were the most common findings. Overall, 26.5% of CE examinations resulted in a new diagnosis and 44.9% of CE exams led to a change in therapy. For patients with IBD, CE findings resulted in an even higher therapeutic change rate of 48.1%. CONCLUSIONS: CE is a safe and feasible diagnostic method to study the small intestine in children, especially for IBD. Incomplete study could be an indicator of positive finding and can potentially be a guide to identify the site of possible strictures.

16.
Sensors (Basel) ; 24(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38931744

RESUMO

This research proposes a miniature circular polarization antenna used in a wireless capsule endoscopy system at 2.45 GHz for industrial, scientific, and medical bands. We propose a method of cutting a chamfer rectangular slot on a circular radiation patch and introducing a curved radiation structure into the centerline position of the chamfer rectangular slot, while a short-circuit probe is added to achieve miniaturization. Therefore, we significantly reduced the size of the antenna and made it exhibit circularly polarized radiation characteristics. A cross-slot is cut in the GND to enable the antenna to better cover the operating band while being able to meet the complex human environment. The effective axis ratio bandwidth is 120 MHz (2.38-2.50 GHz). Its size is π × 0.032λ02 × 0.007λ0 (where λ0 is the free-space wavelength of at 2.4 GHz). In addition, the effect of different organs such as muscle, stomach, small intestine, and big intestine on the antenna when it was embedded into the wireless capsule endoscopy (WCE) system was further discussed, and the results proved that the WCE system has better robustness in different organs. The antenna's specific absorption rate can follow the IEEE Standard Safety Guidelines (IEEE C95.1-1999). A prototype is fabricated and measured. The experimental results are consistent with the simulation results.


Assuntos
Endoscopia por Cápsula , Desenho de Equipamento , Tecnologia sem Fio , Endoscopia por Cápsula/instrumentação , Endoscopia por Cápsula/métodos , Humanos , Tecnologia sem Fio/instrumentação , Cápsulas Endoscópicas
17.
Gastroenterol Hepatol ; : 502223, 2024 Jun 20.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38908683

RESUMO

OBJECTIVES: To search for parameters susceptible to optimization when performing capsule endoscopy (CE) in a third level hospital with high volume and experience in this test. PATIENTS AND METHODS: Retrospective observational study, including 1325 CEs performed between 2017 and 2022. Overall diagnostic yield, effective diagnostic yield, by indication, place of request and waiting list, as well as complete examination rate and cleansing degree were analyzed. RESULTS: The overall diagnostic yield was 70.99%, while the effective diagnostic yield was 72.7%. Diagnostic yields varied between 60.2% and 77.9% depending on the indication and between 64.7% and 74.3% depending on the requesting center. The mean waiting list was 101.15 days, with a tendency to worse results when the waiting list was longer. A total of 77.8% of the examinations were complete. Completion rates were lower in patients >70 years of age (p=0.001), as well as in those with gastric transit >60minutes (p=0.000). A total of 77.3% were clean, with debris that did not impede diagnosis being found in 16.9% and debris that did impede diagnosis in 5.8%. There was a relationship, although not significant, between cleansing degree and age. CONCLUSIONS: The diagnostic yields of CE in our center are in line with those previously reported. Differences were found according to the place of request. Waiting list could also influence diagnostic yield. Completion rates are lower in >70 years of age and when gastric transit is >60minutes. Cleansing degree achieved is acceptable.

18.
Gastroenterol Hepatol ; : 502235, 2024 Aug 05.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39111390

RESUMO

OBJECTIVE: Crohn's disease (CD) is heterogeneous, and proximal involvement in the small bowel (SB) is associated with worse outcomes. Nonetheless, studies on the impact of duodenal and jejunal lesions in SB CD are limited. This study aimed to investigate the clinical characteristics and outcomes of individuals diagnosed with SB CD, comparing those with and without proximal inflammation. METHODS: A cohort of 53 treatment-naive SB CD patients that underwent Capsule Endoscopy at diagnosis were retrospectively selected. The inflammatory activity was quantified using the Lewis Score for each SB tertile. RESULTS: Thirty-seven (69.8%) patients displayed inflammatory activity in the first and/or second tertile together with third tertile involvement (Proximal+T3 group). Sixteen (30.2%) had inflammation in the third tertile only (T3 group). Individuals in the Proximal+T3 group had a higher risk for moderate-to-severe inflammation (OR 4.93, 95% CI: 1.3-18.3, p=0.013). A subgroup analysis for those with mild inflammatory activity showed that individuals in the Proximal+T3 group initiated biologic drugs more often (OR 11, 95% CI: 1.1-109.7, p=0.036). CONCLUSION: Proximal SB lesions are associated with increased inflammatory activity, necessitating more frequent use of biologics in patients with mild disease. Early detection of proximal SB CD with Capsule Endoscopy may contribute to timely treatment.

19.
Medicina (Kaunas) ; 60(7)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39064549

RESUMO

Gastroesophageal reflux disease (GERD) is one of the most common diseases that occurs secondary to failure of the antireflux barrier system, resulting in the frequent and abnormal reflux of gastric contents to the esophagus. GERD is diagnosed in routine clinical practice based on the classic symptoms of heartburn and regurgitation. However, a subset of patients with atypical symptoms can pose challenges in diagnosing GERD. An esophagogastroduodenoscopy (EGD) is the most common initial diagnostic test used in the assessment for GERD, although half of these patients will not have any positive endoscopic findings suggestive of GERD. The advanced endoscopic techniques have improved the diagnostic yield of GERD diagnosis and its complications, such as Barrett's esophagus and early esophageal adenocarcinoma. These newer endoscopic tools can better detect subtle irregularities in the mucosa and vascular structures. The management options for GERD include lifestyle modifications, pharmacological therapy, and endoscopic and surgical interventions. The latest addition to the armamentarium is the minimally invasive endoscopic interventions in carefully selected patients, including the electrical stimulation of the LES, Antireflux mucosectomy, Radiofrequency therapy, Transoral Incisionless Fundoplication, Endoscopic Full-Thickness plication (GERDx™), and suturing devices. With the emergence of these advanced endoscopic techniques, it is crucial to understand their selection criteria, advantages, and disadvantages.


Assuntos
Refluxo Gastroesofágico , Humanos , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/terapia , Fundoplicatura/métodos , Endoscopia do Sistema Digestório/métodos
20.
Artigo em Inglês | MEDLINE | ID: mdl-39138994

RESUMO

BACKGROUND: Currently, there is no automated method for assessing cleanliness in video capsule endoscopy (VCE). Our objectives were to automate the process of evaluating and collecting medical scores of VCE frames according to the existing KOrea-CanaDA (KODA) scoring system by developing an easy-to-use mobile application called artificial intelligence-KODA (AI-KODA) score, as well as to determine the inter-rater and intra-rater reliability of the KODA score among three readers for prospective AI applications, and check the efficacy of the application. METHOD: From the 28 patient capsule videos considered, 1539 sequential frames were selected at five-minute intervals, and 634 random frames were selected at random intervals during small bowel transit. The frames were processed and shifted to AI-KODA. Three readers (gastroenterology fellows), who had been trained in reading VCE, rated 2173 frames in duplicate four weeks apart after completing the training module on AI-KODA. The scores were saved automatically in real time. Reliability was assessed for each video using estimate of intra-class correlation coefficients (ICCs). Then, the AI dataset was developed using the frames and their respective scores, and it was subjected to automatic classification of the scores via the random forest and the k-nearest neighbors classifiers. RESULTS: For sequential frames, ICCs for inter-rater variability were 'excellent' to 'good' among the three readers, while ICCs for intra-rater variability were 'good' to 'moderate'. For random frames, ICCs for inter-rater and intra-rater variability were 'excellent' among the three readers. The overall accuracy achieved was up to 61% for the random forest classifier and 62.38% for the k-nearest neighbors classifier. CONCLUSIONS: AI-KODA automates the process of scoring VCE frames based on the existing KODA score. It saves time in cleanliness assessment and is user-friendly for research and clinical use. Comprehensive benchmarking of the AI dataset is in process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA