Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Exp Ther Med ; 27(1): 2, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38223322

RESUMO

Following the exhaustion of all conventional hemodialysis access options in the upper extremities, a prosthetic arteriovenous loop was performed between the brachial artery (BA) and the external jugular vein (EJV) as a novel access option for hemodialysis in the present case report. During the procedure, a polytetrafluoroethylene graft was anastomosed to the BA and the EJV, and looped on the upper limb. The safety and reliability of BA-EJV access was evaluated by determining the complications, patency and intervention rates. The patient was then followed up for 20 months. The graft became thrombosed 20 months after the placement. There were no complications, such as infection, bleeding or aneurysmal lesions. Overall, the present study demonstrates that hemodialysis via BA-EJV access represents an unusual, yet effective and safe procedure, which may be conducted with acceptable complications and patency rates.

2.
J Vasc Access ; 20(1): 12-18, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29681225

RESUMO

OBJECTIVES:: To describe the UK and Ireland experience of the Haemodialysis Reliable Outflow graft in complex vascular access. DESIGN:: Observational, multi-centre case series. METHODS:: Data from any patient undergoing Haemodialysis Reliable Outflow graft were collected from eight UK and one Irish centre. Any Haemodialysis Reliable Outflow procedure between July 2013 and May 2016 was included. Demographics, primary and secondary patency rates, and complications were analysed. RESULTS:: A total of 52 patients underwent Haemodialysis Reliable Outflow graft insertion. Median age was 55 (20-86) years, 24 (46%) were male and 66% were Caucasian. Median follow-up was 290 (10-966) days and patient survival was 41/52 (79%). In total, 48 procedures were in the upper limb with 39 using the brachial artery as inflow (75%). The internal jugular vein and subclavian vein were most frequently used as access for outflow insertion. Primary patency rates at 6, 12, and 24 months were 51.2% (95% confidence interval, 38.8%-67.4%), 40.9% (95% confidence interval, 28.7%-58.2%), and 33.4% (95% confidence interval, 21.3%-52.5%), respectively. Secondary patency rates at 6, 12, and 24 months were 84.8% (95% confidence interval, 75%-95.9%), 76.5% (95% confidence interval, 64.5%-90.6%), and 70.6% (95% confidence interval, 56%-88.9%), respectively. There were 65 surgical and 49 radiological interventions resulting in 2.30 interventions per year to retain patency. Complications included four infections and two episodes of steal syndrome. CONCLUSION:: The Haemodialysis Reliable Outflow graft provides acceptable 12-month secondary patency rates and acceptable complication rates in a UK and Ireland multi-centre series of complex access patients. Haemodialysis Reliable Outflow should be considered in patients with central pathology as a potential alternative to lower limb grafts and long-term central venous catheters.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Tomada de Decisão Clínica , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Irlanda , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Grau de Desobstrução Vascular , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA