Resultados 1 - 9 de 9
Filtrar
1.
Eur Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967660

RESUMO

PURPOSE: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT). METHODS: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images. RESULTS: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%). CONCLUSION: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses. CLINICAL RELEVANCE STATEMENT: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice. KEY POINTS: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

2.
AJR Am J Roentgenol ; 212(4): 796-801, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30673342

RESUMO

OBJECTIVE: The objective of our study was to investigate the impact of large body habitus on dual-energy CT (DECT) image quality and stone characterization. MATERIALS AND METHODS: We retrospectively included 105 consecutive patients with large body habitus (> 90 kg) who underwent stone protocol DECT between 2015 and 2017. The evaluation of DECT datasets was performed for image quality assessment based on European Guidelines on Quality Criteria for Computed Tomography and for determination of stone composition (i.e., uric acid vs non-uric acid). Correlation between DECT characterization and crystallography results was performed when available. The cohort was divided into two groups on the basis of body weight (≤ 104 kg and > 104 kg), and comparisons were made for image quality and stone characterization. RESULTS: One hundred ninety-seven urinary tract calculi (size: mean ± SD, 5.7 ± 5.3 mm; range, 1.4-56 mm) were detected in 73% (79/108) of examinations in 105 patients (weight: mean ± SD, 104.0 ± 12.7 kg; range, 91-163 kg). The overall mean image quality score of blended images and color maps was 3.7 and 3.9, respectively, and the effective dual-energy FOV limitation did not hamper stone characterization. The diagnostic acceptability scores of blended images and color maps were slightly lower in patients weighing > 104 kg than in patients ≤ 104 kg (mean scores [highest score, 4 points]: blended images, 3.62 vs 3.82 [p = 0.0314]; color maps, 3.75 vs 3.98 [p = 0.0034]), but the scores were within acceptable range. Stone characterization as uric acid versus non-uric acid was achieved in 80% (158/197) of calculi (size: mean ± SD, 6.4 ± 5.7 mm; range, 1.6-56 mm), and DECT stone characterization was (95.6%) accurate with reference to crystallography. Twenty percent (39/197) of calculi could not be characterized on DECT, and these calculi were significantly smaller in size (size: mean ± SD, 2.8 ± 1.4 mm; range, 1.4-8.2 mm; p < 0.001) than those that could be characterized. The mean size of uncharacterized calculi was slightly larger in patients weighing > 104 kg (3.3 ± 1.6 mm) than in those weighing ≤ 104 kg (2.2 ± 0.6 mm). CONCLUSION: In patients with large body habitus, dual-source DECT provides acceptable image quality and allows characterization of almost all clinically significant calculi.


Assuntos
Obesidade/complicações , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Cálculos Urinários/química
3.
AJR Am J Roentgenol ; 213(3): W114-W122, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31082273

RESUMO

OBJECTIVE. The objective of our study was to investigate the potentials of enhanced dual-source dual-energy CT (DECT) and three-planar measurements for differentiating invasive pulmonary adenocarcinomas (IPAs) from preinvasive lesions appearing as pure ground-glass nodules (pGGNs). MATERIALS AND METHODS. Thirty-nine patients with 53 pGGNs who underwent enhanced dual-source DECT were included in this retrospective study. All pGGNs were pathologically confirmed and categorized into two groups: preinvasive lesions or IPAs. The traditional CT features of the pGGNs were evaluated on unenhanced images. Quantitative parameters were measured on iodine-enhanced images of dual-source DECT in three planes, and both intra- and interobserver reproducibility analyses were performed to assess the measurement reproducibility of quantitative parameters. To identify significant factors for differentiating IPAs from preinvasive lesions, we performed logistic regression analysis and ROC curve analysis. RESULTS. For traditional CT features, only lesion size and unenhanced CT attenuation value showed significant differences between preinvasive lesions and IPAs (p < 0.05). Preinvasive lesions and IPAs exhibited significant differences in attenuation on virtual images, so-called "virtual HU" or "VHU," and the modified normalized iodine concentration (NIC) (p < 0.05), and both intra- and interobserver agreement for the quantitative measurements were excellent. Multivariate logistic regression analysis revealed that larger lesion size (adjusted odds ratio [OR], 3.65) and higher modified NIC (adjusted OR, 19.01) were significant differentiators of IPAs from preinvasive lesions (p < 0.05). ROC curve analysis revealed that modified NIC showed excellent performance (AUC, 0.924) and significantly higher performance than lesion size (AUC, 0.711) for differentiating IPAs from preinvasive lesions. CONCLUSION. In pGGNs, a lesion with a modified NIC value of more than 0.29 can be a very specific discriminator of IPAs from preinvasive lesions, and IPAs can be accurately and reliably differentiated from preinvasive lesions using enhanced dual-source DECT and three-planar measurements.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Invasividade Neoplásica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/patologia , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Nódulos Pulmonares Múltiplos/patologia , Invasividade Neoplásica/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Med Phys ; 51(3): 1822-1831, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37650780

RESUMO

BACKGROUND: Due to technical constraints, dual-source dual-energy CT scans may lack spectral information in the periphery of the patient. PURPOSE: Here, we propose a deep learning-based iterative reconstruction to recover the missing spectral information outside the field of measurement (FOM) of the second source-detector pair. METHODS: In today's Siemens dual-source CT systems, one source-detector pair (referred to as A) typically has a FOM of about 50 cm, while the FOM of the other pair (referred to as B) is limited by technical constraints to a diameter of about 35 cm. As a result, dual-energy applications are currently only available within the small FOM, limiting their use for larger patients. To derive a reconstruction at B's energy for the entire patient cross-section, we propose a deep learning-based iterative reconstruction. Starting with A's reconstruction as initial estimate, it employs a neural network in each iteration to refine the current estimate according to a raw data fidelity measure. Here, the corresponding mapping is trained using simulated chest, abdomen, and pelvis scans based on a data set containing 70 full body CT scans. Finally, the proposed approach is tested on simulated and measured dual-source dual-energy scans and compared against existing reference approaches. RESULTS: For all test cases, the proposed approach was able to provide artifact-free CT reconstructions of B for the entire patient cross-section. Considering simulated data, the remaining error of the reconstructions is between 10 and 17 HU on average, which is about half as low as the reference approaches. A similar performance with an average error of 8 HU could be achieved for real phantom measurements. CONCLUSIONS: The proposed approach is able to recover missing dual-energy information for patients exceeding the small 35 cm FOM of dual-source CT systems. Therefore, it potentially allows to extend dual-energy applications to the entire-patient cross section.


Assuntos
Aprendizado Profundo , Humanos , Tomografia Computadorizada por Raios X , Tórax , Imagens de Fantasmas , Algoritmos , Processamento de Imagem Assistida por Computador
5.
Acad Radiol ; 30(5): 855-862, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35760710

RESUMO

RATIONAL AND OBJECTIVES: Comparison of radiation dose and image quality in routine abdominal and pelvic contrast-enhanced computed tomography (CECT) between a photon-counting detector CT (PCD-CT) and a dual energy dual source CT (DSCT). MATERIALS AND METHODS: 70 oncologic patients (mean age 66 ± 12 years, 29 females) were prospectively enrolled between November 2021 and February 2022. Abdominal CECT were clinically indicated and performed first on a 2nd-generation DSCT and at follow-up on a 1st-generation dual-source PCD-CT. The same contrast media (Imeron 350, Bracco imaging) and pump protocol was used for both scans. For both scanners, polychromatic images were reconstructed with 3mm slice thickness and comparable kernel (I30f[DSCT] and Br40f[PCD-CT]); for PCD-CT data from all counted events above the lowest energy threshold at 20 keV ("T3D") were used. Results were compared in terms of radiation dose metrics of CT dose index (CTDIvol), dose length product (DLP) and size-specific dose estimation (SSDE), objective and subjective measurements of image quality were scored by two emergency radiologists including lesion conspicuity. RESULTS: Median time interval between the scans was 4 months (IQR: 3-6). CNRvessel and SNRvessel of T3D reconstructions from PCD-CT were significantly higher than those of DSCT (all, p < 0.05). Qualitative image noise analysis from PCD-CT and DSCT yielded a mean of 4 each. Lesion conspicuity was rated significantly higher in PCD-CT (Q3 strength) compared to DSCT images. CTDI, DLP and SSDE mean values for PCD-CT and DSCT were 7.98 ± 2.56 mGy vs. 14.11 ± 2.92 mGy, 393.13 ± 153.55 mGy*cm vs. 693.61 ± 185.76 mGy*cm and 9.98 ± 2.41 vs. 14.63 ± 1.63, respectively, translating to a dose reduction of around 32% (SSDE). CONCLUSION: PCD-CT enables oncologic abdominal CT with a significantly reduced dose while keeping image quality similar to 2nd-generation DSCT.


Assuntos
Abdome , Redução da Medicação , Doses de Radiação , Tomografia por Raios X , Tomografia por Raios X/métodos , Abdome/diagnóstico por imagem , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Intensificação de Imagem Radiográfica
6.
Tomography ; 8(3): 1466-1476, 2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-35736867

RESUMO

Our aim was to compare the image quality and patient dose of contrast-enhanced oncologic chest-CT of a first-generation photon-counting detector (PCD-CT) and a second-generation dual-source dual-energy CT (DSCT). For this reason, one hundred consecutive oncologic patients (63 male, 65 ± 11 years, BMI: 16−42 kg/m2) were prospectively enrolled and evaluated. Clinically indicated contrast-enhanced chest-CT were obtained with PCD-CT and compared to previously obtained chest-DSCT in the same individuals. The median time interval between the scans was three months. The same contrast media protocol was used for both scans. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120 kVp. DSCT was performed using 100 kV for Tube A and 140 kV for Tube B. "T3D" PCD-CT images were evaluated, which emulate conventional 120 keV polychromatic images. For DSCT, the convolution algorithm was set at I31f with class 1 iterative reconstruction, whereas comparable Br40 kernel and iterative reconstruction strengths (Q1 and Q3) were applied for PCD-CT. Two radiologists assessed image quality using a five-point Likert scale and performed measurements of vessels and lung parenchyma for signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and in the case of pulmonary metastases tumor-to-lung parenchyma contrast ratio. PCD-CT CNRvessel was significantly higher than DSCT CNRvessel (all, p < 0.05). Readers rated image contrast of mediastinum, vessels, and lung parenchyma significantly higher in PCD-CT than DSCT images (p < 0.001). Q3 PCD-CT CNRlung_parenchyma was significantly higher than DSCT CNRlung_parenchyma and Q1 PCD-CT CNRlung_parenchyma (p < 0.01). The tumor-to-lung parenchyma contrast ratio was significantly higher on PCD-CT than DSCT images (0.08 ± 0.04 vs. 0.03 ± 0.02, p < 0.001). CTDI, DLP, SSDE mean values for PCD-CT and DSCT were 4.17 ± 1.29 mGy vs. 7.21 ± 0.49 mGy, 151.01 ± 48.56 mGy * cm vs. 288.64 ± 31.17 mGy * cm and 4.23 ± 0.97 vs. 7.48 ± 1.09, respectively. PCD-CT enables oncologic chest-CT with a significantly reduced dose while maintaining image quality similar to a second-generation DSCT for comparable protocol settings.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Masculino , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
7.
Gland Surg ; 10(4): 1347-1358, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33968686

RESUMO

BACKGROUND: To evaluate the diagnostic performance of quantitative spectral parameters derived from dual-source dual-energy CT at small field of view (FOV) for small lymph node metastasis in thyroid cancer. METHODS: This was a retrospective diagnostic study. From 2016 to 2019, 280 patients with thyroid disease underwent thin-section dual-source dual-energy thyroid CT and thyroid surgery. The data of patients with lymph nodes having a short diameter of 2-6 mm was analyzed. The quantitative dual-energy CT parameters of targeted lymph nodes were measured, and all parameters between metastatic and non-metastatic lymph nodes were compared. These parameters were then fitted to univariable and multivariable binary logistic regression models. The diagnostic role of spectral parameters was analyzed by receiver operating characteristic (ROC) curves and compared with the McNemar test. Small FOV CT images and a mathematical model were used to judge the status of lymph nodes respectively, and then compared with the golden criterion-pathological diagnosis. The cut-off value of the model was 0.4419, with a sensitivity of 90.2% and a specificity of 92.7%. RESULTS: Of the 216 lymph nodes investigated in this study, 52.3% and 23.6% had a short diameter of 2-3 and 4 mm, respectively. Multiple quantitative CT parameters were significantly different between benign and malignant lymph nodes, and binary regression analysis was performed. The mathematical model was: p=ey/(1+ ey), y=-23.119+0.033× precontrast electron cloud density +0.076× arterial phase normalized iodine concentration +2.156× arterial phase normalized effective atomic number -0.540× venous phase slope of the spectral Hounsfield unit curve +1.676× venous phase iodine concentration. This parameter model had an AUC of 92%, with good discrimination and consistency, and the diagnostic accuracy was 90.3%. The diagnostic accuracy of the CT image model was 43.1%, and for lymph nodes with a short-diameter of 2-3 mm, the diagnostic accuracy was 22.1%. CONCLUSIONS: The parameter model showed higher diagnostic accuracy than the CT image model for diagnosing small lymph node metastasis in thyroid cancer, and quantitative dual-energy CT parameters were very useful for small lymph nodes that were difficult to be diagnosed only on conventional CT images. TRIAL REGISTRATION: This study is retrospectively registered, and we have registered a prospective study (Registration number: ChiCTR2000035195; http://www.chictr.org.cn).

8.
Eur J Radiol ; 84(5): 884-91, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25650332

RESUMO

OBJECTIVES: To evaluate the clinical feasibility of dual-source dual-energy CT angiography (DSDECTA) with virtual non-enhanced images and iodine map for active gastrointestinal bleeding (GIB). METHODS: From June 2010 to December 2012, 112 consecutive patients with clinical signs of active GIB underwent DSDECTA with true non-enhanced (TNE), arterial phase with single-source mode, and portal-venous phase with dual-energy mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs). Virtual non-enhanced CT (VNE) image sets and iodine map were reformatted from 'Liver VNC' software. The mean CT number, noise, signal to noise ratio (SNR), image quality and radiation dose were compared between TNE and VNE image sets. Two radiologists, blinded to clinical data, interpreted images from DSDECTA with TNE (protocol 1), and DSDECTA with VNE and iodine map (protocol 2) respectively, with discordant interpretation resolved by consensus. The standards of reference included digital subtraction angiography, endoscopy, surgery, or final pathology reports. Receiver-operating characteristic (ROC) analysis was undertaken and the area under the curve (AUC) calculated for CT protocols 1 and 2, respectively. RESULTS: There was no significant difference in mean CT numbers of all organs (including liver, pancreas, spleen, kidney, abdominal aorta, and psoas muscle) (P>0.05). Lower noise and higher SNR were found on VNE images than TNE images (P<0.05). Image quality of VNE was lower than that of TNE without significant difference (P>0.05). The active GIB source was identified in 84 patients, 83 (83/84, 98.8%) of which were confirmed by one or more reference standard. The AUC was 0.935±0.027 and 0.947±0.026 for protocols 1 and 2, respectively. There was no significant difference between protocols 1 and 2 for diagnostic performance (Z=1.672, P>0.05). The radiation dose reduction achieved by omitting the TNE acquisition was (30.11±6.32)%. CONCLUSION: DSDECTA with arterial phase with single-source mode, portal-venous phase with dual-energy mode and post-processing VNE image sets and iodine map could act as an accurate screening method for detection and localization of active GIB with lower radiation dose.


Assuntos
Angiografia Digital/instrumentação , Meios de Contraste , Hemorragia Gastrointestinal/diagnóstico por imagem , Iodo , Veia Porta/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Angiografia Digital/métodos , Área Sob a Curva , Endoscopia Gastrointestinal , Estudos de Viabilidade , Feminino , Hemorragia Gastrointestinal/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/patologia , Valor Preditivo dos Testes , Curva ROC , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Índice de Gravidade de Doença , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
9.
Int J Clin Exp Med ; 8(5): 7802-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26221332

RESUMO

PURPOSE: To investigate the clinical utility of dual-source dual-energy CT angiography (DSDECTA) for diagnosing intracranial dural arteriovenous fistula (DAVF). METHODS: Nine intracranial DAVF patients were examined using Siemens DSDECTA and cerebral digital subtraction angiography (DSA). Imaging data were retrospectively analyzed to evaluate the concordance between the imaging modalities. RESULTS: DSDECTA examination showed that the blood-supplying arteries were thickened and the draining veins and dural sinuses were expanded in all 9 patients. The presence and characteristics of intracranial DAVF were confirmed using DSA. Head CT showed subarachnoid hemorrhage in 4 cases and intracerebral hematoma in 3 cases. CONCLUSION: Although DSA is the gold standard for DAVF diagnosis, DSDECTA is less invasive and more suitable for revealing the three-dimensional structure of secondary intracranial lesions as well as other DAVF characteristics. Thus, DSDECTA may be a new alternative for noninvasive screening of suspected DAVF patients before interventional embolization and surgical resection.

SELEÇÃO DE REFERÊNCIAS