Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37050806

RESUMO

Although microwave photonic approaches have been used for fiber sensing applications before, most contributions in the past dealt with evaluating the sensor signal's amplitude. Carrying this topic on, the authors previously presented a scheme for the interrogation of fiber sensors that was based on a fiber Bragg grating's phase response for the electrical signal. However, neither has the measurement setup been analyzed nor have the amplitude and phase-based approaches been compared in detail before. Hence, this paper picks up the previously proposed setup, which relies on an amplitude modulation of the optical signal and investigates for sources of signal degradation, an aspect that has not been considered before. Following the incorporation of the microwave signal, the setup is suitable not only for an amplitude-based evaluation of fiber Bragg gratings but also for a phase-based evaluation. In this context, the signal-to-noise ratios are studied for the conventional amplitude-based evaluation approach and for the recently developed phase-based approach. The findings indicate a strong advantage for the signal-to-noise ratio of the phase response evaluation; an 11 dB improvement at the least has been found for the examined setup. Further studies may investigate the consequences and additional benefits of this approach for radio-over-fiber sensing systems or general performance aspects such as achievable sensitivity and sampling rates.

2.
Sensors (Basel) ; 20(13)2020 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-32630829

RESUMO

Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids.


Assuntos
Acústica , Microscopia de Força Atômica , Nanomedicina , Humanos
3.
Sensors (Basel) ; 18(7)2018 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-30011898

RESUMO

A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Ácidos Nucleicos/análise , Potenciometria/instrumentação , Temperatura , Eletrodos , Concentração de Íons de Hidrogênio , Ácidos Nucleicos/isolamento & purificação , Salmonella/genética , Semicondutores
4.
Biosens Bioelectron ; 87: 447-452, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27591719

RESUMO

We report a method to suppress streaming potential using an Ag-coated microfluidic channel on a p-type silicon nanowire (SiNW) array measured by a multiplexed electrical readout. The metal layer sets a constant electrical potential along the microfluidic channel for a given reference electrode voltage regardless of the flow velocity. Without the Ag layer, the magnitude and sign of the surface potential change on the SiNW depends on the flow velocity, width of the microfluidic channel and the device's location inside the microfluidic channel with respect to the reference electrode. Noise analysis of the SiNW array with and without the Ag coating in the fluidic channel shows that noise frequency peaks, resulting from the operation of a piezoelectric micropump, are eliminated using the Ag layer with two reference electrodes located at inlet and outlet. This strategy presents a simple platform to eliminate the streaming potential and can become a powerful tool for nanoscale potentiometric biosensors.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Nanofios/química , Silício/química , Prata/química , Condutividade Elétrica , Eletrodos , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA