Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Molecules ; 28(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36985767

RESUMO

Fe-based chemical looping gasification is a clean biomass technology, which has the advantage of reducing CO2 emissions and the potential of self-sustaining operation without supplemental heating. A novel process combining Fe-based chemical looping and biomass pyrolysis was proposed and simulated using Aspen Plus. The biomass was first subjected to pyrolysis to coproduce biochar, bio-oil and pyrolysis gas; the pyrolysis gas was subjected to an Fe looping process to obtain high-purity hydrogen and carbon dioxide. The influences of the pyrolysis reactor operating temperature and fuel reactor operation temperature, and the steam reactor and air reactor on the process performance are researched. The results showed that, under the operating condition of the established process, 23.07 kg/h of bio-oil, 24.18 kg/h of biochar, 3.35 kg/h of hydrogen and a net electricity of 3 kW can be generated from 100 kg/h of rice straw, and the outlet CO2 concentration of the fuel reactor was as high as 80%. Moreover, the whole exergy efficiency and total exergy loss of the proposed process was 58.98% and 221 kW, respectively. Additionally, compared to biomass direct chemical looping hydrogen generation technology, the new process in this paper, using biomass pyrolysis gas as a reactant in the chemical looping hydrogen generation process, can enhance the efficiency of hydrogen generation.


Assuntos
Dióxido de Carbono , Hidrogênio , Pirólise , Biomassa , Temperatura Alta
2.
Molecules ; 28(6)2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36985620

RESUMO

Hydrogen production using polymer membrane electrolyzers is an effective and valuable way of generating an environmentally friendly energy source. Hydrogen and oxygen generated by electrolyzers can power drone fuel cells. The thermodynamic analysis of polymer membrane electrolyzers to identify key losses and optimize their performance is fundamental and necessary. In this article, the process of the electrolysis of water by a polymer membrane electrolyzer in combination with a concentrated solar system in order to generate power and hydrogen was studied, and the effect of radiation intensity, current density, and other functional variables on the hydrogen production was investigated. It was shown that with an increasing current density, the voltage generation of the electrolyzer increased, and the energy efficiency and exergy of the electrolyzer decreased. Additionally, as the temperature rose, the pressure dropped, the thickness of the Nafion membrane increased, the voltage decreased, and the electrolyzer performed better. By increasing the intensity of the incoming radiation from 125 W/m2 to 320 W/m2, the hydrogen production increased by 111%, and the energy efficiency and exergy of the electrolyzer both decreased by 14% due to the higher ratio of input electric current to output hydrogen. Finally, machine-learning-based predictions were conducted to forecast the energy efficiency, exergy efficiency, voltage, and hydrogen production rate in different scenarios. The results proved to be very accurate compared to the analytical results. Hyperparameter tuning was utilized to adjust the model parameters, and the models' results showed an MAE lower than 1.98% and an R2 higher than 0.98.

3.
Energy Build ; 278: 112623, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36345312

RESUMO

With increasing energy use and outbreaks of respiratory infectious diseases (such as COVID-19) in buildings, there is a growing interest in creating healthy and energy-efficient indoor environments. A novel heating system named low-temperature radiant floor coupled with intermittent stratum ventilation (LTR-ISV) is proposed in this study. Thermal performance, indoor air quality, energy and exergy performance were investigated and compared with conventional radiant floor heating (CRFH) and conventional radiant floor heating with mixing ventilation (CRFH + MV). The results indicated that LTR-ISV had a more uniform operative temperature distribution and overall thermal sensation, and air mixing was enhanced without generating additional draft sensation. Compared with CRFH and CRFH + MV, the indoor CO2 concentration in LTR-ISV can be reduced by 1355 ppm and 400 ppm, respectively. Airborne transmission risk can also be reduced by 5.35 times. The coefficient of performance for CRFH, CRFH + MV, and LTR-ISV during working hours was 4.2, 2.5, and 3.4, respectively. The lower value of LTR-ISV was due to the high energy usage of the primary air handing unit. In the non-working hours, LTR-ISV was 0.6 and 1.3 higher compared to CRFH and CRFH + MV, respectively. The exergy efficiency of LTR-ISV, CRFH, and CRFH + MV was 81.77 %, 76.43 %, and 64.71 %, respectively. Therefore, the LTR-ISV system can meet the requirements of high indoor air quality and thermal comfort and provides a reference for the energy-saving use of low-grade energy in space heating.

4.
Entropy (Basel) ; 24(12)2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36554225

RESUMO

Nanorefrigerant is a mixture of nanoparticles and pure refrigerant, which can increase heat transfer characteristics in refrigeration and air conditioning equipment. The performance of four different Al2O3 nanorefrigerants and their pure fluids (R600a, R134a, R1234yf, and R1233zd(E)) is analyzed in a vapor-compression refrigeration cycle. The enthalpy of a nanorefrigerant in the refrigeration cycle is calculated by using the prediction method based on the density of nanorefrigerant. A numerical model is established for the thermodynamic analysis, and the results show that adding nanoparticles to the pure refrigerant enhances heat transfer in heat exchangers, increases cooling capacity, reduces compressor power consumption, and finally improves the performance of the refrigeration system. The COP improvement of R1233zd(E) + Al2O3 nanorefrigerant is the highest, and the COP improvement of R134a + Al2O3 and R1234yf + Al2O3 are close to each other. When the mass fraction of Al2O3 nanoparticles increases to 0.30%, the COP of R1233zd(E) and R600a increases by more than 20%; the maximum exergy efficiency is 38.46% for R1233zd(E) + Al2O3, and the minimum exergy efficiency is 27.06% for pure R1234yf. The results provide a basis for the application of nanorefrigerants in the vapor compression refrigeration cycle.

5.
Entropy (Basel) ; 24(5)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35626555

RESUMO

Even though there is a pressing interest in clean energy sources, compression ignition (CI) engines, also called diesel engines, will remain of great importance for transportation sectors as well as for power generation in stationary applications in the foreseeable future. In order to promote applications dealing with complex diesel alternative fuels by facilitating their integration in numerical simulation, this paper targets three objectives. First, generate novel diesel fuel surrogates with more than one component. Here, five surrogates are generated using an advanced chemistry solver and are compared against three mechanisms from the literature. Second, validate the suggested reaction mechanisms (RMs) with experimental data. For this purpose, an engine configuration, which features a reacting spray flow evolving in a direct-injection (DI), single-cylinder, and four-stroke motor, is used. The RNG k-Epsilon coupled to power-law combustion models is applied to describe the complex in-cylinder turbulent reacting flow, while the hybrid Eulerian-Lagrangian Kelvin Helmholtz-Rayleigh Taylor (KH-RT) spray model is employed to capture the spray breakup. Third, highlight the impact of these surrogate fuels on the combustion properties along with the exergy of the engine. The results include distribution of temperature, pressure, heat release rate (HRR), vapor penetration length, and exergy efficiency. The effect of the surrogates on pollutant formation (NOX, CO, CO2) is also highlighted. The fifth surrogate showed 47% exergy efficiency. The fourth surrogate agreed well with the maximum experimental pressure, which equaled 85 Mpa. The first, second, and third surrogates registered 400, 316, and 276 g/kg fuel, respectively, of the total CO mass fraction at the outlet. These quantities were relatively higher compared to the fourth and fifth RMs.

6.
Entropy (Basel) ; 24(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35885125

RESUMO

A multi-objective optimization based on the non-dominated sorting genetic algorithm (NSGA-II) is carried out in the present work for the basic organic Rankine cycle (BORC) and regenerative ORC (RORC) systems. The selection of working fluids is integrated into multi-objective optimization by parameterizing the pure working fluids into a two-dimensional array. Two sets of decision indicators, exergy efficiency vs. thermal efficiency and exergy efficiency vs. levelized energy cost (LEC), are adopted and examined. Five decision variables including the turbine inlet temperature, vapor superheat degree, the evaporator and condenser pinch temperature differences, and the mass fraction of the mixture are optimized. It is found that the turbine inlet temperature is the most effective factor for both the BORC and RORC systems. Compared to the reverse variation of exergy efficiency and thermal efficiency, only a weak conflict exists between the exergy efficiency and LEC which tends to make the binary objective optimization be a single objective optimization. The RORC provides higher thermal efficiency than BORC at the same exergy efficiency while the LEC of RORC also becomes higher because the bare module cost of buying one more heat exchange is higher than the cost reduction due to the reduced heat transfer area. Under the heat source temperature of 423.15 K, the final obtained exergy and thermal efficiencies are 45.6% and 16.6% for BORC, and 38.6% and 20.7% for RORC, respectively.

7.
Entropy (Basel) ; 24(2)2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35205518

RESUMO

With its outstanding performance characteristics, the SOFC represents a promising technology for integration into the current energy supply system. For cell development and optimization, a reliable quantitative description of the transport mechanisms and the resulting losses are relevant. The local transport processes are calculated by a 1D model based on the non-equilibrium thermodynamics (NET). The focus of this study is the mass transport in the gas diffusion layers (GDL), which was described as simplified by Fick's law in a previously developed model. This is first replaced by the Dusty-Gas model (DGM) and then by the thermal diffusion (Soret effect) approach. The validation of the model was performed by measuring U,j-characteristics resulting in a maximum deviation of experimental to simulated cell voltage to up to 0.93%. It is shown that, under the prevailing temperature, gradients the Soret effect can be neglected, but the extension to the DGM has to be considered. The temperature and heat flow curves illustrate the relevance of the Peltier effects. At T=1123.15 K and j=8000 A/m2, 64.44% of the total losses occur in the electrolyte. The exergetic efficiency for this operating point is 0.42. Since lower entropy production rates can be assumed in the GDL, the primary need is to investigate alternative electrolyte materials.

8.
Entropy (Basel) ; 23(12)2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34945969

RESUMO

Porous media burner (PMB) is widely used in a variety of practical systems, including heat exchangers, gas propulsion, reactors, and radiant burner combustion. However, thorough evaluations of the performance of the PMB based on the usefulness of entropy generation, thermal and exergy efficiency aspects are still lacking. In this work, the concept of a double-layer micro PMB with a 23 mm cylindrical shape burner was experimentally demonstrated. The PMB was constructed based on the utilization of premixed butane-air combustion which consists of an alumina and porcelain foam. The tests were designed to cover lean to rich combustion with equivalence ratios ranging from ϕ = 0.6 to ϕ = 1.2. It was found that the maximum thermal and exergy efficiency was obtained at ϕ = 1.2 while the lowest thermal and exergy efficiency was found at ϕ = 0.8. Furthermore, the findings also indicated that the total entropy generation, energy loss, and exergy destroyed yield the lowest values at ϕ = 1.0 with 0.0048 W/K, 98.084 W, and 1.456 W, respectively. These values can be stated to be the suitable operating conditions of the PMB. The findings provided useful information on the design and operation in a double-layer PMB.

9.
Entropy (Basel) ; 22(1)2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33285889

RESUMO

Data from a two-stage axial vapor cryogenic compressor on the dual-fuel diesel-electric (DFDE) liquefied natural gas (LNG) carrier were measured and analyzed to investigate compressor energy and exergy efficiency in real exploitation conditions. The running parameters of the two-stage compressor were collected while changing the main propeller shafts rpm. As the compressor supply of vaporized gas to the main engines increases, so does the load and rpm in propulsion electric motors, and vice versa. The results show that when the main engine load varied from 46 to 56 rpm at main propulsion shafts increased mass flow rate of vaporized LNG at a two-stage compressor has an influence on compressor performance. Compressor average energy efficiency is around 50%, while the exergy efficiency of the compressor is significantly lower in all measured ranges and on average is around 34%. The change in the ambient temperature from 0 to 50 °C also influences the compressor's exergy efficiency. Higher exergy efficiency is achieved at lower ambient temperatures. As temperature increases, overall compressor exergy efficiency decreases by about 7% on average over the whole analyzed range. The proposed new concept of energy-saving and increasing the compressor efficiency based on pre-cooling of the compressor second stage is also analyzed. The temperature at the second stage was varied in the range from 0 to -50 °C, which results in power savings up to 26 kW for optimal running regimes.

10.
Entropy (Basel) ; 22(10)2020 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-33286851

RESUMO

This study conducted an exergy analysis of advanced adsorption cooling cycles. The possible exergy losses were divided into internal losses and external losses, and the exergy losses of each process in three advanced cycles: a mass recovery cycle, heat recovery cycle and combined heat and mass recovery cycle were calculated. A transient two-dimensional numerical model was used to solve the heat and mass transfer kinetics. The exergy destruction of each component and process in a finned tube type, silica gel/water working paired-adsorption chiller was estimated. The results showed that external loss was significantly reduced at the expense of internal loss. The mass recovery cycle reduced the total loss to 60.95 kJ/kg, which is -2.76% lower than the basic cycle. In the heat recovery cycle, exergy efficiency was significantly enhanced to 23.20%. The optimum value was 0.1248 at a heat recovery time of 60 s. The combined heat and mass recovery cycle resulted in an 11.30% enhancement in exergy efficiency, compared to the heat recovery cycle. The enhancement was much clearer when compared to the basic cycle, with 37.12%. The observed dependency on heat recovery time and heating temperature was similar to that observed for individual mass recovery and heat recovery cycles.

11.
Entropy (Basel) ; 22(10)2020 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-33286873

RESUMO

The performance of porous media micro-burners plays an important role in determining thermal efficiency and improving our daily life. Nowadays, a lot of scholars are actively involved in this research area and ongoing studies are still being carried out due to the burners' excellent performance. The exergy efficiency and entropy generation of a porous media burner are strongly dependent on the characteristics of the flame and its thermal behavior. In this study, a single-layer and double-layer porous media form were constructed to investigate the effects of various types of porous foam arrangement in a cylindrical burner. The burner was operated using premixed butane-air combustion with an inner diameter of 23 mm and a length of 100 mm. The experiments were carried out in rich fuel conditions with an equivalence ratio, φ ranging from 1.3 to 2.0. The results showed significant improvement in the thermal and exergy efficiency with an increase in the equivalence ratio in a double-layer compared with a single-layer. The peak temperature recorded was 945.21 °C at φ = 1.3 for a porcelain single-layer, and the highest exergy efficiency was 83.47% at φ = 2.0 for an alumina-porcelain double-layer burner. It was also found that the average temperature of the burner wall decreased with an increase in the equivalence ratios for PMB2 and PMB4, whereas the average wall temperature for PMB3 was largely unaffected by the equivalence ratios. The total entropy generation rate reached the highest value at φ = 2.0 for all PMB configurations, and the highest percentage increase for total entropy generation rate was 46.09% for PMB1. The exergy efficiency for all burners was approximately similar with the highest exergy efficiency achieved by PMB4 (17.65%). In addition, the length and location of the flame with thermal distribution was significantly affected by the equivalence ratio between the single-layer and double-layer porous material. Overall, a double-layer porous media burner showed the best performance calculated based on the second law of thermodynamics when compared with other configurations, and it is ideal for domestic application.

12.
Entropy (Basel) ; 22(3)2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33286079

RESUMO

This article deals with the thermodynamic assessment of supercritical carbon dioxide (S-CO2) Brayton power cycles. The main advantage of S-CO2 cycles is the capability of achieving higher efficiencies at significantly lower temperatures in comparison to conventional steam Rankine cycles. In the past decade, variety of configurations and layouts of S-CO2 cycles have been investigated targeting efficiency improvement. In this paper, four different layouts have been studied (with and without reheat): Simple Brayton cycle, Recompression Brayton cycle, Recompression Brayton cycle with partial cooling and the proposed layout called Recompression Brayton cycle with partial cooling and improved heat recovery (RBC-PC-IHR). Energetic and exergetic performances of all configurations were analyzed. Simple configuration is the least efficient due to poor heat recovery mechanism. RBC-PC-IHR layout achieved the best thermal performance in both reheat and no reheat configurations ( η t h   = 59.7% with reheat and η t h   = 58.2 without reheat at 850 °C), which was due to better heat recovery in comparison to other layouts. The detailed component-wise exergy analysis shows that the turbines and compressors have minimal contribution towards exergy destruction in comparison to what is lost by heat exchangers and heat source.

13.
Entropy (Basel) ; 22(6)2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-33286388

RESUMO

This article proposes the utilization of the concepts of destroyed exergy and exergy efficiency for equipment and process performance indicators that are related to the current energy planning scenario in Brazil, more specifically with energy-efficiency labelling. Several indicators associated with these concepts are discussed, including one national program that is based on labeling the energy efficiency of several residential, commercial and industrial appliances. The grades are indicated in the equipment using values from A to G. This labeling system is useful for discriminating similar technologies used for the same function; nevertheless produced by different enterprises. For this complementary analysis, two types of refrigeration methods were compared, absorption and vapor compression; however, these energy indexes alone are not sufficient parameters to select among these two technologies, because their performance indexes definition are different. To address this, our research considers the second law of thermodynamics through exergy analysis as a proper sub-index to obtain a systematic comparison between these various indicators. It is significant to highlight that seldom research studies addressed to this problem so explicitly, in an actual governmental working solution, aiming at discussing to the society the advantage of the usage of the "quality of the energy" as a complementary index to governmental and personal choices. Results indicate that it is possible to use the destroyed exergy and exergy efficiency to help select the technology that better utilizes natural resources, considering the energy matrix of the country. Appliances for water heating and air conditioning were compared from energy and exergy viewpoint, where the last gave additional information about the quality of energy conversion process, giving a completely different trend from the energy analysis alone, without the necessity to think about the energy matrix. Later this issue is addressed from both points of view. Future studies may suggest an exergy based index. The energy efficiency suggests that electrical shower (values higher than 95%) are better than gas water heaters (83% ) in using natural resources, whereas the exergy efficiency shares similar magnitudes (about 3%). A related pattern is shown for the theoretical air conditioning systems. The vapor compression systems have an energy index higher than 3, and absorption systems lower than 1. For these circumstances, the exergy efficiency shows figures nearby 30%.

14.
Entropy (Basel) ; 23(1)2020 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-33396854

RESUMO

The main research objective of this paper was to compare exergy performance of three different heat pump (HP)-based systems and one natural gas (NG)-based system for the production of heating and cooling energy in a single-house dwelling. The study considered systems based on: 1. A NG and auxiliary cooling unit; 2. Solely HP, 3. HP with additional seasonal heat storage (SHS) and a solar thermal collector (STC); 4. HP with SHS, a STC and a grey water (GW) recovery unit. The assessment of exergy efficiencies for each case was based on the transient systems simulation program TRNSYS, which was used for the simulation of energy use for space heating and cooling of the building, sanitary hot water production, and the thermal response of the seasonal heat storage and solar thermal system. The results show that an enormous waste of exergy is observed by the system based on an NG boiler (with annual overall exergy efficiency of 0.11) in comparison to the most efficient systems, based on HP water-water with a seasonal heat storage and solar thermal collector with the efficiency of 0.47. The same system with an added GW unit exhibits lower water temperatures, resulting in the exergy efficiency of 0.43. The other three systems, based on air-, water-, and ground-water HPs, show significantly lower annual source water temperatures (10.9, 11.0, 11.0, respectively) compared to systems with SHS and SHS + GW, with temperatures of 28.8 and 19.3 K, respectively.

15.
Entropy (Basel) ; 22(9)2020 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-33286728

RESUMO

Industrial nitrogen liquefaction cycles are based on the Collins topology but integrate variations. Several pressure levels with liquefaction to medium pressure and compressor-expander sets are common. The cycle must be designed aiming to minimise specific power consumption rather than to maximise liquid yield. For these reasons, conclusions of general studies cannot be extrapolated directly. This article calculates the optimal share of total compressed flow to be expanded in an industrial Collins-based cycle for nitrogen liquefaction. Simulations in Unisim Design R451 using Peng Robinson EOS for nitrogen resulted in 88% expanded flow, which is greater than the 75-80% for conventional Collins cycles with helium or other substances. Optimum specific compression work resulted 430.7 kWh/ton of liquid nitrogen. For some operating conditions, the relation between liquid yield and specific power consumption was counterintuitive: larger yield entailed larger consumption. Exergy analysis showed 40.3% exergy efficiency of the optimised process. The exergy destruction distribution and exergy flow across the cycle is provided. Approximately 40% of the 59.7% exergy destruction takes place in the cooling after compression. This exergy could be used for secondary applications such as industrial heating, energy storage or for lower temperature applications as heat conditioning.

16.
Entropy (Basel) ; 21(4)2019 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-33267102

RESUMO

This paper presents an exergy-efficiency analysis of low-temperature district heating systems (DHSs) with different sanitary hot-water (SHW) boosters. The required temperature of the sanitary hot water (SHW) was set to 50 °C. The main objective of this study was to compare the exergy efficiencies of a DHS without a booster to DHSs with three different types of boosters, i.e., electric-, gas-boiler- and heat-pump-based, during the winter and summer seasons. To achieve this, we developed a generalized model for the calculation of the exergy efficiency of a DHS with or without the booster. The results show that during the winter season, for a very low relative share of SHW production, the DHS without the booster exhibits favorable exergy efficiencies compared to the DHSs with boosters. By increasing this share, an intersection point above 45 °C for the supply temperatures, at which the higher exergy efficiency of a DHS with a booster prevails, can be identified. In the summer season the results show that a DHS without a booster at a supply temperature above 70 °C achieves lower exergy efficiencies compared to DHSs with boosters at supply temperatures above 40 °C. The results also show that ultra-low supply and return temperatures should be avoided for the DHSs with boosters, due to higher rates of entropy generation.

17.
Entropy (Basel) ; 21(8)2019 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-33267471

RESUMO

One of the main challenges in the design and implementation of fluidized desiccant cooling (FDC) systems is increasing their low COP (coefficient of performance). Exergy analysis is one of the tools especially suitable for improvement and optimization of FDC systems. The improvement of performance is impossible as long as the main sources of exergy destruction are not identified and evaluated. In this paper, the exergy analysis was applied in order to identify these components and processes of the FDC system that are mainly responsible for exergy destruction. Moreover, the exergy efficiency of a simple fluidized desiccant cooler was determined. The results showed that fluidized beds and regenerative heat exchanger were the main exergy destruction sources with a 32% and 18% share of total exergy destruction, respectively. On the other hand, the direct evaporative cooler and air cooler placed after the desorbing fluidized bed were characterized by the lowest exergy efficiencies. This work contributes to better understanding of FDC operation principles and improvement of the performance of FDC technology.

18.
Entropy (Basel) ; 22(1)2019 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-33285779

RESUMO

In this study, the energy and exergy of an automobile refrigeration system using R134a and R134a/R1234yf were analyzed experimentally with respect to outdoor air temperature and compressor speed. As outdoor air temperature increased from 32.5 °C to 37.5 °C, the coefficient of performance (COP) and total exergy destruction rate of the refrigeration system using Mix30 decreased by 5.19% and 25.8% on average, compared to that of the system using R134a. The exergy efficiency of the Mix30 refrigeration system was on average 21.8% higher than that of the R134a system. As the compressor rotating speed increased from 1000 to 2000 rpm, the cooling capacity of the refrigeration system using R134a and R134a/R1234yf increased, while the COP decreased. The COP and total exergy destruction rate of the refrigeration system using Mix30 decreased by 4.82% and 19.5%, compared to that of the system using R134a. The exergy efficiency of the Mix30 refrigeration system increased on average by 20.7%, compared to that of the R134a system. The total exergy destruction rate of the automobile refrigeration system using R134a/R1234yf decreased with increase in R1234yf, while exergy efficiency increased. In addition, the exergy destruction rate of the automobile refrigeration system decreased as the amount of R1234yf in the R134a/R1234yf automobile refrigeration system increased.

19.
Entropy (Basel) ; 21(4)2019 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-33267075

RESUMO

The continuous energy transformation processes in heating, ventilation, and air conditioning systems of buildings are responsible for 36% of global final energy consumption. Tighter thermal insulation requirements for buildings have significantly reduced heat transfer losses. Unfortunately, this has little effect on energy demand for ventilation. On the basis of the First and the Second Law of Thermodynamics, the concepts of entropy and exergy are applied to the analysis of ventilation air handling unit (AHU) with a heat pump, in this paper. This study aims to develop a consistent approach for this purpose, taking into account the variations of reference temperature and temperatures of working fluids. An analytical investigation on entropy generation and exergy analysis are used, when exergy is determined by calculating coenthalpies and evaluating exergy flows and their directions. The results show that each component of the AHU has its individual character of generated entropy, destroyed exergy, and exergy efficiency variation. However, the evaporator of the heat pump and fans have unabated quantities of exergy destruction. The exergy efficiency of AHU decreases from 45-55% to 12-15% when outdoor air temperature is within the range of -30 to +10 °C, respectively. This helps to determine the conditions and components of improving the exergy efficiency of the AHU at variable real-world local climate conditions. The presented methodological approach could be used in the dynamic modelling software and contribute to a wider application of the Second Law of Thermodynamics in practice.

20.
Entropy (Basel) ; 20(2)2018 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33265210

RESUMO

The first and second laws of thermodynamics were applied to the human body in order to evaluate the quality of the energy conversion during muscle activity. Such an implementation represents an important issue in the exergy analysis of the body, because there is a difficulty in the literature in evaluating the performed power in some activities. Hence, to have the performed work as an input in the exergy model, two types of exercises were evaluated: weight lifting and aerobic exercise on a stationary bicycle. To this aim, we performed a study of the aerobic and anaerobic reactions in the muscle cells, aiming at predicting the metabolic efficiency and muscle efficiency during exercises. Physiological data such as oxygen consumption, carbon dioxide production, skin and internal temperatures and performed power were measured. Results indicated that the exergy efficiency was around 4% in the weight lifting, whereas it could reach values as high as 30% for aerobic exercises. It has been shown that the stationary bicycle is a more adequate test for first correlations between exergy and performance indices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA