Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.707
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
BMC Infect Dis ; 24(1): 1013, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300348

RESUMO

BACKGROUND: Postoperative wound infections (PWIs) significantly impact patient outcomes following open reduction and internal fixation (ORIF) of rib fractures. Identifying and understanding risk factors associated with these infections are crucial for improving surgical outcomes and patient care. METHODS: This retrospective study, conducted from January 2020 to October 2023 at our institution, aimed to analyze the risk factors for PWIs in patients undergoing ORIF for rib fractures. A total of 150 patients were included, with 50 in the infected group and 100 in the non-infected control group, matched for demographic and clinical characteristics. Data on variables such as intraoperative blood loss, hospital stay duration, body mass index (BMI), operation time, presence of anemia, drainage time, diabetes mellitus status, smoking habits, and age were collected. Statistical analysis involved univariate and multivariate logistic regression using SPSS software (Version 27.0), with p-values < 0.05 considered statistically significant. RESULTS: Univariate analysis revealed no significant association between intraoperative blood loss or hospital stay duration and PWIs. However, operation time ≥ 5 h, anemia, drainage time ≥ 7 days, diabetes mellitus, smoking, and age ≥ 60 years were significantly associated with higher PWI rates. Multivariate logistic regression confirmed these factors as independent predictors of PWIs, with operation time and diabetes mellitus showing particularly strong associations. CONCLUSIONS: Prolonged operation time, anemia, extended drainage, diabetes mellitus, smoking, and advanced age significantly increase the risk of PWIs following ORIF for rib fractures. Early identification and targeted management of these risk factors are essential to reduce the incidence of infections and improve postoperative outcomes.


Assuntos
Fixação Interna de Fraturas , Fraturas das Costelas , Infecção da Ferida Cirúrgica , Humanos , Masculino , Fatores de Risco , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Fixação Interna de Fraturas/efeitos adversos , Idoso , Fraturas das Costelas/cirurgia , Adulto , Redução Aberta/efeitos adversos , Duração da Cirurgia , Tempo de Internação/estatística & dados numéricos
2.
World J Surg ; 48(6): 1309-1314, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38553827

RESUMO

INTRODUCTION: Sternal fractures are rare, causing significant pain, respiratory compromise, and decreased upper extremity range of motion. Sternal fixation (SF) is a viable treatment option; however, there remains a paucity of literature demonstrating long-term benefits. This study examined long-term outcomes of SF, hypothesizing they have better long-term quality of life (QoL) than patients managed nonoperatively (NOM). METHODS: This was a survey study at our level 1 academic hospital. All patients diagnosed with a sternal fracture were included from January 2016 to July 2021. Patients were grouped whether they received SF or NOM. Basic demographics were obtained. Three survey phone call attempts were conducted. The time from injury to survey was recorded. Outcomes included responses to the QoL survey, which included mobility, self-care, usual activities, chest pain/discomfort, and anxiety/depression. The survey scale is 1-5 (1 = worst condition possible; 5 = best possible condition). Patients were asked to rate their current health on a scale of 0-100 (100 being the best possible health imaginable). Chi square and t-tests were used. Significance was set at p < 0.05. RESULTS: Three hundred eighty four patients were surveyed. Sixty nine underwent SF and 315 were NOM. Thirty-eight (55.1%) SF patients and 126 (40%) NOM patients participated in the survey. Basic demographics were similar. Average days from sternal fracture to survey was 1198 (±492) for the SF group and 1454 (±567) for the NOM group. The SF cohort demonstrated statistically significant better QoL than the NOM cohort for all categories except anxiety/depression. CONCLUSION: SF provides better long-term QoL and better overall health scores compared to NOM.


Assuntos
Fraturas Ósseas , Qualidade de Vida , Esterno , Humanos , Esterno/lesões , Esterno/cirurgia , Masculino , Feminino , Fraturas Ósseas/terapia , Fraturas Ósseas/cirurgia , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Idoso , Fixação de Fratura/métodos , Inquéritos e Questionários , Fatores de Tempo , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos
3.
J Musculoskelet Neuronal Interact ; 24(3): 310-317, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39219329

RESUMO

OBJECTIVES: To compare early outcomes of proximal femoral bionic nail (PFBN), Inter-TAN, proximal femoral nail antirotation (PFNA) for intertrochanteric fractures in elderly patients. METHODS: Eighty-two elderly patients with intertrochanteric femoral fractures treated at Xiangyang No. 1 People's Hospital affiliated with Hubei University of Medicine from December 2021 to 2022 were retrospectively analyzed. They were categorized into three surgical groups: PFBN (22 cases), Inter-TAN (20 cases), and PFNA (40 cases). Preoperative demographics and fracture characteristics were compared, alongside intraoperative and postoperative metrics like operative time and complication rates. RESULTS: In the PFBN group, operative time, fluoroscopy use, blood loss, and transfusion were higher, but postoperative weight-bearing, healing, and hospital stay were shorter compared to the Inter-TAN and PFNA groups (P<0.05). Inter-TAN had a significantly shorter postoperative weight-bearing time than PFNA (P<0.001). Other compared factors showed no significant differences between groups (P>0.05), including complication rates and scores at 6-month follow-up. CONCLUSIONS: PFBN, a novel surgical approach for intertrochanteric fractures in elderly patients, outperforms Inter-TAN and PFNA by accelerating early weight-bearing and hastening fracture recovery.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Feminino , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/efeitos adversos , Masculino , Idoso , Fraturas do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Pinos Ortopédicos , Suporte de Carga/fisiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
4.
J Musculoskelet Neuronal Interact ; 24(2): 178-184, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38826000

RESUMO

OBJECTIVE: To investigate the effect of pericapsular nerve group (PENG) block combined with spinal anesthesia in the treatment of elderly patients with intertrochanteric fractures through "rapid diagnosis and treatment channel" PFNA internal fixation. METHODS: 52 elderly patients were randomly divided into the observation group (26 patients, PENG block combined with spinal anesthesia) and the control group (26 patients, spinal anesthesia alone). The general health, mean arterial pressure (MAP), and heart rate (HR) of both groups were compared at various stages: immediately before the administration of pain analgesia, during the positioning of spinal epidural anesthesia, at the beginning and end of the surgery, and 2 hours after surgery. Additionally, VAS scores at rest and during passive straight leg elevation by 15° were evaluated at 12 hours, 24 hours, 48 hours, 72 hours, and 7 days after surgery. RESULTS: The MAP and HR in the observation group under spinal anesthesia in the lateral position were lower than those in the control group (P < 0.05). Additionally, the VAS scores of the observation group during positioning and at 12 hours and 24 hours after surgery were lower than those in the control group under spinal epidural anesthesia (both P < 0.05). CONCLUSION: The application of ultrasound-guided PENG block combined with lumbar anesthesia can reduce pain when in lateral position, stabilize perioperative vital signs, and result in high satisfaction.


Assuntos
Raquianestesia , Fraturas do Quadril , Bloqueio Nervoso , Humanos , Raquianestesia/métodos , Idoso , Masculino , Feminino , Bloqueio Nervoso/métodos , Fraturas do Quadril/cirurgia , Idoso de 80 Anos ou mais , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/tratamento farmacológico
5.
Childs Nerv Syst ; 40(7): 2153-2160, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38498172

RESUMO

PURPOSE: Surgical treatment for atlantoaxial instability in pediatric patients is challenging. We report our experience with posterior intra-articular distraction technique in treating this disorder. METHODS: This is a retrospective descriptive study which included 15 patients of atlantoaxial instability whose age was less than 16 years at the time of clinical presentation. All patients underwent anterior soft tissue released through a posterior-only approach, followed by intra-facet cage implantation, cantilever correction, and instrumentation. Clinical results were measured using the Japanese Orthopedic Association (JOA) scale and radiographic measurements including the atlantodental interval (ADI), posterior atlantodental interval (pADI), the distance of odontoid tip above Chamberlain's line, clivuscanal angle (CCA), and triangular area (TA) of craniovertebral junction. RESULTS: The follow-up period ranged from 18 to 72 months, with an average of 41.2 ± 15.2 months. The JOA score increased from 13.6 ± 2.3 to 16.6 ± 0.8. ADI decreased from 4.31 ± 2.37 to 1.85 ± 1.09 mm, and TA decreased from 261.96 ± 107.99 to 197.12 ± 72.37 mm2. pADI increased from 12.89 ± 3.52 to 18.25 ± 3.89 mm, and CCA improved from 132.19 ± 16.34 to 144.35 ± 13.91°. All changes in measurements showed statistically significant. There were no evidence of surgery-related complications or iatrogenic secondary cervical deformity during follow-up. Radiological evaluation showed satisfactory corrections and bony fusions of C1-2 facet joint in all cases. CONCLUSION: Posterior intra-articular distraction followed by cage implantation and cantilever correction can be one of the safe and effective ways to solve atlantoaxial instability in pediatric patients.


Assuntos
Articulação Atlantoaxial , Instabilidade Articular , Humanos , Articulação Atlantoaxial/cirurgia , Articulação Atlantoaxial/diagnóstico por imagem , Instabilidade Articular/cirurgia , Instabilidade Articular/diagnóstico por imagem , Feminino , Masculino , Criança , Adolescente , Estudos Retrospectivos , Resultado do Tratamento , Fusão Vertebral/métodos , Pré-Escolar
6.
BMC Musculoskelet Disord ; 25(1): 533, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992608

RESUMO

BACKGROUND: The purpose of this study was to perform a biomechanical analysis to compare different medial column fixation patterns for valgus pilon fractures in a case-based model. METHODS: Based on the fracture mapping, 48 valgus pilon fracture models were produced and assigned into four groups with different medial column fixation patterns: no fixation (NF), K-wires (KW), intramedullary screws (IS), and locking compression plate (LCP). Each group contained wedge-in and wedge-out subgroups. After fixing each specimen on the machine, gradually increased axial compressive loads were applied with a load speed of one millimeter per minute. The maximum peak force was set at 1500 N. Load-displacement curves were generated and the axial stiffness was calculated. Five different loads of 200 N, 400 N, 600 N, 800 N, 1000 N were selected for analysis. The specimen failure was defined as resultant loading displacement over 3 mm. RESULTS: For the wedge-out models, Group-IS showed less displacement (p < 0.001), higher axial stiffness (p < 0.01), and higher load to failure (p < 0.001) than Group-NF. Group-KW showed comparable displacement under loads of 200 N, 400 N and 600 N with both Group-IS and Group-LCP. For the wedge-in models, no statistical differences in displacement, axial stiffness, or load to failure were observed among the four groups. Overall, wedge-out models exhibited less axial stiffness than wedge-in models (all p < 0.01). CONCLUSIONS: Functional reduction with stable fixation of the medial column is essential for the biomechanical stability of valgus pilon fractures and medial column fixation provides the enough biomechanical stability for this kind of fracture in the combination of anterolateral fixation. In detail, the K-wires can provide a provisional stability at an early stage. Intramedullary screws are strong enough to provide the medial column stability as a definitive fixation. In future, this technique can be recommended for medial column fixation as a complement for holistic stability in high-energy valgus pilon fractures.


Assuntos
Placas Ósseas , Fraturas da Tíbia , Humanos , Fenômenos Biomecânicos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/fisiopatologia , Fios Ortopédicos , Masculino , Suporte de Carga , Feminino , Adulto , Pessoa de Meia-Idade
7.
BMC Musculoskelet Disord ; 25(1): 857, 2024 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-39465375

RESUMO

OBJECTIVE: This study aims to analyze the differences in mechanical stability of OTA/AO 31A1.3 intertrochanteric fractures under various reduction conditions. METHODS: Twenty standard synbone artificial femur test bones were selected for the OTA/AO 31A1.3 intertrochanteric fracture model. The models were divided into five groups according to their reduction state: positive support, neutral support, negative support, varus fixation, and valgus fixation, with four specimens in each group. All models were fixed using PFNA intramedullary fixation and subjected to static axial compression tests. The subsidence displacement of the proximal femur under different loads and the axial stiffness of the model were measured to verify the mechanical stability of the OTA/AO 31A1.3 intertrochanteric fracture under different reduction conditions. RESULTS: After the static axial compression test, the proximal femoral subsidence displacement in the positive support and neutral support groups was lower than that in the negative support, valgus fixation, and varus fixation groups (p < 0.001). The axial stiffness of the model was highest in the positive support group. Significant differences in subsidence displacement and axial stiffness were found between the groups (p < 0.001). The positive support group demonstrated the best mechanical stability, while the varus fixation group showed the poorest performance. CONCLUSION: Positive support of the medial cortex can be regarded as the best reduction state for OTA/AO 31A1.3 intertrochanteric fractures, suggesting that this approach should be preferred during surgery to enhance mechanical stability and improve clinical outcomes. Conversely, varus fixation should be avoided due to its inferior stability.


Assuntos
Fraturas do Quadril , Fenômenos Biomecânicos/fisiologia , Humanos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/fisiopatologia , Fêmur/cirurgia , Fêmur/fisiopatologia , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Modelos Anatômicos
8.
BMC Musculoskelet Disord ; 25(1): 645, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39148072

RESUMO

BACKGROUND: A coracoid process fracture combined with an acromioclavicular (AC) joint dislocation is an uncommon injury that typically causes significant pain and limits shoulder movement. Open reduction and internal fixation have been the traditional treatment approach. However, arthroscopic techniques are emerging as a promising alternative for managing these injuries. CASE REPRESENTATION: A 35-year-old woman presented with right shoulder pain following an accidental fall. Imaging studies revealed a coracoid process fracture along with an AC joint dislocation. The fracture was classified as an Eyres Type IIIA, which warranted surgical intervention. Our team performed arthroscopic coracoid fracture reduction and internal fixation surgery, as well as AC joint dislocation repair using Kirschner wires. Six months after surgery, the patient demonstrated a satisfactory functional outcome with complete bone healing. CONCLUSION: This case report highlights the potential of arthroscopic reduction and fixation as a novel treatment option for fractures of the coracoid base.


Assuntos
Artroscopia , Parafusos Ósseos , Processo Coracoide , Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Feminino , Adulto , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Artroscopia/métodos , Processo Coracoide/cirurgia , Processo Coracoide/lesões , Processo Coracoide/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Resultado do Tratamento , Articulação Acromioclavicular/cirurgia , Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/diagnóstico por imagem , Escápula/cirurgia , Escápula/lesões , Escápula/diagnóstico por imagem
9.
BMC Musculoskelet Disord ; 25(1): 107, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308240

RESUMO

BACKGROUND: To investigate the biomechanical effects of screw orientation and fracture block size on the internal fixation system for Letenneur type II Hoffa fractures. METHODS: The fracture models were randomly divided into six groups according to the fracture subtypes and the direction of nail placement, and a plumb line of the posterior condylar tangent was made across the base of the posterior femoral condyle. The fracture blocks of the three types of fracture were calculated and recorded in the sagittal position, and the biomechanical performance of the six groups was evaluated by biomechanical tests. The axial load on the fracture block at a displacement of 2 mm was set as the failure load, a gradually increasing axial load was applied to each fracture model using a customized indenter at a load of 250-750 N, and the displacements and failure loads of the six groups were recorded at different axial loads. RESULTS: Biomechanical test results showed that the larger the fracture block, the greater was the stability when nailing from front to back, and the smaller the fracture block, the greater was the strength when nailing from back to front (p < 0.001). As the fracture block became larger, the biomechanical advantage of nailing from posterior to anterior decreased.The displacement under 250 N load were 1.351 ± 0.113 mm, 1.465 ± 0.073 mm for Group IIa AP and Group IIa PA. The displacement under 500 N load were 2.596 ± 0.125 mm, 2.344 ± 0.099 mm for Group IIa AP and Group IIa PA. The displacement under 750 N load were 3.997 ± 0.164, 3.386 ± 0.125 mm for Group IIa AP and Group IIa PA. The failure loads were 384 ± 14 N, 415 ± 19 N for Group IIa AP and Group IIa PA. In the type IIa fracture group, the difference was no longer significant (p > 0.001). Therefore, there is a mechanical threshold that ranges from 38.36 to 52.33% between type IIa and type IIb fractures. CONCLUSIONS: The effect of the nailing direction on the strength of fixation has a fracture-block critical point, which is consistent overall with the trend that the larger the fracture block is, the greater the stability when nailing from anterior to posterior, and the smaller the fracture block is, the greater the strength when nailing from posterior to anterior.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fêmur , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia
10.
BMC Musculoskelet Disord ; 25(1): 865, 2024 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-39472863

RESUMO

BACKGROUND: The optimal surgical technique for treating tibial plateau fractures remains controversial. This study aimed to compare the outcomes of arthroscopy-assisted reduction and internal fixation (ARIF) to those of open reduction and internal fixation (ORIF) in treating tibial plateau fractures. METHODS: This systematic review and meta-analysis were conducted to compare surgical outcomes between ARIF versus ORIF for patients with tibial plateau fractures. Relevant studies, comprising randomized controlled trials (RCTs) and non-RCTs, were identified through searches in Cochrane CENTRAL, PubMed, and Embase databases. Risk of bias assessments were conducted using the revised Cochrane risk-of-bias tool for RCTs (RoB 2.0), Newcastle Ottawa scales for non-RCTs, and Joanna Briggs Institute Critical Appraisal Checklist for case series studies. Data synthesis utilized a random-effects model meta-analysis. The primary outcome assessed was functional outcomes, with complications considered as secondary outcomes. RESULTS: There were fifteen studies (one RCT and fourteen non-RCTs) included in this study, comprising a total of 969 participants (548 in the ARIF group and 421 in the ORIF group). Although patients in the ARIF group showed a trend towards better functional outcomes compared to the ORIF group, the difference was not statistically significant (Hospital for special surgery score, mean difference (MD) = 5.13, 95% confidence interval (CI)=-1.67 to 11.92, I²=83%; Knee society score, MD = 5.84, 95% CI=-1.18 to 12.86, I²=74%). No significant differences were noted in infection, stiffness, DVT, and overall complications between two groups. The ARIF group included ten case series studies with a total of 302 patients. The pooled mean Rasmussen Radiological Score was 16.59 (95% CI, 15.72 to 17.50), and the pooled mean Rasmussen Clinical Score was 27.38 (95% CI, 26.45 to 28.33). CONCLUSION: The findings of this study reveal no significant difference in clinical outcomes and complication rates between ARIF and ORIF. Additionally, this study found that the complication rate for patients undergoing ARIF falls within previously reported ranges. This suggests that ARIF is a reliable and effective surgical option for treating tibial plateau fractures, even in cases involving high-energy trauma.


Assuntos
Artroscopia , Fixação Interna de Fraturas , Redução Aberta , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Artroscopia/métodos , Artroscopia/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Resultado do Tratamento , Redução Aberta/métodos , Redução Aberta/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Fraturas do Planalto Tibial
11.
BMC Musculoskelet Disord ; 25(1): 290, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622692

RESUMO

BACKGROUND: The proximal femoral nail anti-rotation (PFNA) with cement enhancement enhances the anchorage ability of internal fixation in elderly with osteoporotic intertrochanteric fracture. However, whether it is superior to hemiarthroplasty is still controversial. The present study aimed to determine which treatment has better clinical outcomes among older patients. METHODS: We retrospectively analyzed 102 elderly patients with osteoporosis who developed intertrochanteric fractures and underwent PFNA combined with cement-enhanced internal fixation (n = 52, CE group), and hemiarthroplasty (n = 50, HA group) from September 2012 to October 2018. All the intertrochanteric fractures were classified according to the AO/OTA classification. Additionally, the operative time, intraoperative blood loss, intraoperative and postoperative blood transfusion rates, postoperative weight-bearing time, hospitalization time, Barthel Index of Activities Daily Living, Harris score of hip function, visual analog (VAS) pain score, and postoperative complications were compared between the two groups. RESULTS: The CE group had significantly shorter operative time, lesser intraoperative blood loss, lower blood transfusion rate, and longer postoperative weight-bearing time than the HA group. The CE group had lower Barthel's Index of Activities of Daily Living, lower Harris' score, and higher VAS scores in the first and third months after surgery than the HA group, but no difference was observed between the two groups from 6 months to 12 months. There was no significant difference in the total post-operative complications between the two groups. CONCLUSION: The use of PFNA combined with a cement-enhanced internal fixation technique led to shorter operative time and lesser intraoperative blood loss and trauma in elderly patients as compared to HA.


Assuntos
Fixação Intramedular de Fraturas , Hemiartroplastia , Fraturas do Quadril , Humanos , Idoso , Estudos Retrospectivos , Pinos Ortopédicos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Perda Sanguínea Cirúrgica/prevenção & controle , Atividades Cotidianas , Resultado do Tratamento , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Cimentos Ósseos/uso terapêutico , Complicações Pós-Operatórias/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos
12.
BMC Musculoskelet Disord ; 25(1): 552, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39014409

RESUMO

BACKGROUND: To evaluate the effectiveness of a sequential internal fixation strategy and intramedullary nailing with plate augmentation (IMN/PA) for bone reconstruction in the management of infected femoral shaft defects using the Masquelet technique. METHODS: We performed a retrospective descriptive cohort study of 21 patients (mean age, 36.4 years) with infected bone defects of the femoral shaft treated by the Masquelet technique with a minimum follow-up of 18 months after second stage. After aggressive debridement, temporary stabilisation (T1) was achieved by an antibiotic-loaded bone cement spacer and internal fixation with a bone cement-coated locking plate. At second stage (T2), the spacer and the locking plate were removed following re-debridement, and IMN/PA was used as definitive fixation together with bone grafting. We evaluated the following clinical outcomes: infection recurrence, bone union time, complications, and the affected limb's knee joint function. RESULTS: The median and quartiles of bone defect length was 7 (4.75-9.5) cm. Four patients required iterative debridement for infection recurrence after T1. The median of interval between T1 and T2 was 10 (9-19) weeks. At a median follow-up of 22 (20-27.5) months, none of the patients experienced recurrence of infection. Bone union was achieved at 7 (6-8.5) months in all patients, with one patient experiencing delayed union at the distal end of bone defect due to screws loosening. At the last follow-up, the median of flexion ROM of the knee joint was 120 (105-120.0)°. CONCLUSIONS: For infected femoral shaft bone defects treated by the Masquelet technique, sequential internal fixation and IMN/PA for the reconstruction can provide excellent mechanical stability, which is beneficial for early functional exercise and bone union, and does not increase the rate of infection recurrence.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Desbridamento , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Masculino , Estudos Retrospectivos , Feminino , Adulto , Fraturas do Fêmur/cirurgia , Pessoa de Meia-Idade , Desbridamento/métodos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Adulto Jovem , Resultado do Tratamento , Transplante Ósseo/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Seguimentos , Cimentos Ósseos/uso terapêutico , Antibacterianos/uso terapêutico , Antibacterianos/administração & dosagem , Fêmur/cirurgia , Adolescente
13.
BMC Musculoskelet Disord ; 25(1): 417, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807120

RESUMO

OBJECTIVE: To digitally measure the fixation trajectory of anatomical plates used in the combined reduction of quadrilateral acetabular fractures via the posterior approach, and to develop anatomical plates that align with the characteristics of the pelvis in the Chinese population. METHODS: Pelvic computed tomography (CT) data from 102 adult patients were collected at the Affiliated Hospital of Zunyi Medical University. This group included 51 males and 51 females, aged between 20 and 60 years. Using Mimics software (version 21.0), a three-dimensional model of each pelvic data point was reconstructed. The fixation path for the combined reset anatomical steel plate was drawn, where the curves on the fixation path were approximated as arcs. The radius of curvature and length of these curves were measured, and an anatomical steel plate was designed to best fit the pelvic structure. RESULTS: The combined anatomical reduction plate fixation system for quadrilateral acetabular fractures using a posterior approach consisted of two parts: a locking plate and a reduction plate. The posterior wall region (r2), ischial region (r3), quadrilateral region (r4), and bending region (r5), and the total length of the reduction plate were significantly smaller in females (P < 0.05). Similarly, the posterior wall region (R3), distal posterior wall region (R4), and the total length of the locking plate were significantly smaller in females (P < 0.05). Additionally, the anterior superior iliac spine side (r1) and the total length of the T-shaped auxiliary plate were significantly smaller in females (P < 0.05). The bending angle (< A) was also significantly smaller in females (P < 0.05). CONCLUSIONS: The pelvic surface structure is irregular and varies greatly among individuals.Compared to the traditional steel plate, The combined reduction anatomical plate designed in this study demonstrated high precision and improved conformity to the anatomical structure of the pelvis.


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/cirurgia , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Adulto Jovem , Imageamento Tridimensional
14.
BMC Musculoskelet Disord ; 25(1): 580, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048966

RESUMO

BACKGROUND: The calcar of the proximal humerus is a fundamental structure for medial humeral column support. This study aimed to assess the outcome of osteosynthesis across cases of unstable proximal humerus fractures (PHFs) with medial calcar comminution, following treatment with a PHILOS locking plate and medial support screw (MSS). METHODS: Between January 2010 and December 2018, we retrospectively analyzed the outcomes of 121 cases of osteosynthesis for PHFs with medial column disruption. For the medial support, at least one oblique screw was inserted within 5 mm of the subchondral bone in the inferomedial quadrant of the humeral head. All patients were categorized into two groups: 26 patients in the single MSS group, and 95 in the multiple MSS group. Follow-up after at least an year involved clinical and radiographic outcome evaluations, and correspondingly measuring the Constant-Murley score, University of California, Los Angeles (UCLA) shoulder scale, pain visual analogue scale (VAS), major complications, neck-shaft angle (NSA), humeral head height (HHH), and the eventual time to bone union. Risk factors for the major complications were assessed by multivariate logistic regression analyses. RESULTS: The cohort's mean age was 64.4 ± 15.4 years, and the mean follow-up duration was 19.5 ± 7.6 months. At the final follow-up, between the single MSS and multiple MSS groups, no significant differences in the Constant-Murley score (p = 0.367), UCLA score (p = 0.558), VAS (p = 0.571), time to bone union (p = 0.621), NSA loss (p = 0.424), and HHH loss (p = 0.364) were observed. The incidence of complications (p = 0.446) based on the number of MSS were not significantly different. The initial insufficient reduction after surgery (of NSA < 125°) was found to be a significant risk factor for post-surgical complications. CONCLUSIONS: To treat unstable PHFs, the use of at least one MSS along with a locking plate system is sufficient to achieve satisfactory outcomes. Successful operative treatment using a locking plate for PHF treatment is inherent in anatomical fracture reduction, coupled with medial column support.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Seguimentos , Adulto
15.
BMC Musculoskelet Disord ; 25(1): 8, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166882

RESUMO

BACKGROUNDS: This study aimed to analyze the clinical outcomes of femoral neck fractures (FNF) in patients treated with a femoral neck system (FNS, DePuy Synthes), which is a recently introduced device. METHODS: This retrospective cohort study of 43 patients who underwent osteosynthesis using FNS for FNF between July 2019 and June 2021 with a minimum follow-up of 6 months. The researchers examined the patients' demographic factors and radiologically evaluated the fracture type and fixation status, bone union, and postoperative complications. RESULTS: Of 43 patients, 25 were female, and the patients' mean age and body mass index were 62.1 years and 22.5 kg/m2, respectively. According to the Association of Osteosynthesis/Orthopaedic Trauma Association (AO/OTA) classification, the most common fracture types were 31B1.1 and B1.2 (13 cases each), followed by B2.3, B2.1, and B2.2 (seven, five, and four cases, respectively). Radiological bone union was confirmed in 39 patients (90.7%), and the mean time to union was 3.6 months. Two cases of nonunion, one case of lag screw cut-out, and one case of osteonecrosis were confirmed; all four cases later underwent arthroplasty. The mean time to reoperation was 4.5 months. Meanwhile, five patients underwent implant removal after the bone union, and distal locking screw stripping was noted in three patients. All three patients required metal plate cutting to remove the implants. CONCLUSIONS: Osteosynthesis of FNF using the newly introduced FNS showed favorable clinical outcomes and no specific hardware-related complications were reported during the follow-up. However, attention must be paid to the issue regarding distal locking screw failure during hardware removal.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Humanos , Feminino , Masculino , Estudos Retrospectivos , Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/etiologia , Resultado do Tratamento
16.
BMC Musculoskelet Disord ; 25(1): 658, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169336

RESUMO

BACKGROUND: Tension band wire fixation (TBW) is a well-described method for treating displaced olecranon fractures. Further surgery is often needed due to wound breakdown or prominent hardware. An all-suture technique has recently been described as an alternative to TBW but radiographic and clinical outcome are not well established. The aim of this single-center retrospective cohort study was to evaluate outcome after treatment with all-suture technique for simple displaced olecranon fractures. METHODS: A retrospective review of olecranon fractures in patients (> 18 years) treated for displaced olecranon fractures with tension band suture fixation (TBSF) between February and August 2019 was performed in our facility. Primary outcome was revision surgery, which was assessed four years after surgery. Clinical and radiographical follow-up was performed at two weeks, six weeks, three months and six months to assess union rate, fracture displacement, range of motion (ROM), Quick-DASH and Oxford Elbow Score. RESULTS: A total of 24 patients were included. Median age was 64 years [IQR:39-73], 9 patients were male and median ASA score was 2 [IQR:1-2]. 15 fractures were Mayo type 2 A and 9 type 2B with minor comminution. At four-year follow-up, three patients had died. None of the remaining 21 patients had undergone revision surgery. At six months, the median Quick-DASH and Oxford Elbow Score were 2.3 [IQR:0-4.5] and 47 [IQR:46-48], respectively. Median elbow extension and flexion deficits were 0° [IQR:0-2.25] and 0° [IQR:0-0], respectively. Radiographic union was achieved in all patients. In two cases radiographic loss of reduction and malunion was observed but both patients were asymptomatic and had no functional deficits. One patient refractured the elbow due to a second trauma and was reoperated. CONCLUSIONS: TBSF is a promising technique for Mayo type 2 A and 2B fractures with minor comminution. There were no revision surgeries within the first four years. We found good functional outcomes and a high union rate.


Assuntos
Fixação Interna de Fraturas , Fratura do Olécrano , Técnicas de Sutura , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fios Ortopédicos , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Seguimentos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fratura do Olécrano/diagnóstico por imagem , Fratura do Olécrano/cirurgia , Olécrano/lesões , Olécrano/cirurgia , Olécrano/diagnóstico por imagem , Radiografia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
17.
BMC Musculoskelet Disord ; 25(1): 530, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38987728

RESUMO

PURPOSE: Few studies have focused on the risk factors leading to postoperative blood transfusion after open reduction and internal fixation (ORIF) of proximal humeral fractures (PHFs) in the elderly. Therefore, we designed this study to explore potential risk factors of blood transfusion after ORIF for PHFs. We have also established a nomogram model to integrate and quantify our research results and give feedback. METHODS: In this study, we retrospectively analyzed the clinical data of elderly PHF patients undergoing ORIF from January 2020 to December 2021. We have established a multivariate regression model and nomograph. The prediction performance and consistency of the model were evaluated by the consistency coefficient and calibration curve, respectively. RESULTS: 162 patients met our inclusion criteria and were included in the final study. The following factors are related to the increased risk of transfusion after ORIF: time to surgery, fibrinogen levels, intraoperative blood loss, and surgical duration. CONCLUSIONS: Our patient-specific transfusion risk calculator uses a robust multivariable model to predict transfusion risk.The resulting nomogram can be used as a screening tool to identify patients with high transfusion risk and provide necessary interventions for these patients (such as preoperative red blood cell mobilization, intraoperative autologous blood transfusion, etc.).


Assuntos
Transfusão de Sangue , Fixação Interna de Fraturas , Nomogramas , Redução Aberta , Fraturas do Ombro , Humanos , Idoso , Feminino , Masculino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Fraturas do Ombro/cirurgia , Idoso de 80 Anos ou mais , Estudos Transversais , Redução Aberta/efeitos adversos , Redução Aberta/métodos , Fatores de Risco , Medição de Risco , Perda Sanguínea Cirúrgica/prevenção & controle
18.
BMC Musculoskelet Disord ; 25(1): 17, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166758

RESUMO

BACKGROUND: Various surgical techniques and conservative therapies are useful tools for treating proximal humerus fractures (PHFs), but it is important to understand how to properly utilize them. Therefore, we performed a systematic review and network meta-analysis to compare and rank the efficacy and safety of medical treatments for PHF. METHODS: PubMed, Embase, the Cochrane Library, and the ClinicalTrials.gov databases were systematically searched for eligible randomized controlled trials (RCTs) from inception until June 2022. Conservative therapy-controlled or head-to-head RCTs of open reduction internal fixation (ORIF), intramedullary nailing (IMN), hemiarthroplasty (HA), and reverse total shoulder arthroplasty (RTSA) used for the treatment of adult patients with PHF were included. The surface under the cumulative ranking (SUCRA) probabilities were applied to compare and rank the effects of medical treatments for PHF. RESULTS: Eighteen RCTs involving 1,182 patients with PHF were selected for the final analysis. Mostly baseline characteristics among groups were well balanced, and the imbalanced factors only included age, injury type, medial comminution, blood loss, and cognitive function in single trial. The SUCRA probabilities found that RTSA provided the best effect on the Constant-Murley score (SUCRA: 100.0%), and the disabilities of the arm, shoulder and hand (DASH) score (SUCRA: 99.0%). Moreover, HA (SUCRA: 85.5%) and RTSA (SUCRA: 68.0%) had a relatively better effect on health-related quality of life than the other treatment modalities. Furthermore, conservative therapy (SUCRA: 84.3%) and RTSA (SUCRA: 80.7%) were associated with a lower risk of secondary surgery. Finally, the best effects on the risk of complications are varied, including infection was observed with conservative therapy (SUCRA: 94.2%); avascular necrosis was observed in HA (SUCRA: 78.1%), nonunion was observed in RTSA (SUCRA: 69.6%), and osteoarthritis was observed in HA (SUCRA: 93.9%). CONCLUSIONS: This study found that RTSA was associated with better functional outcomes, while the comparative outcomes of secondary surgery and complications varied. Optimal treatment for PHF should consider patient-specific factors.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Fraturas do Úmero , Fraturas do Ombro , Adulto , Humanos , Hemiartroplastia/efeitos adversos , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Metanálise em Rede , Fraturas do Ombro/cirurgia , Fraturas do Ombro/etiologia , Resultado do Tratamento
19.
BMC Surg ; 24(1): 157, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755649

RESUMO

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Assuntos
Acetábulo , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas , Impressão Tridimensional , Humanos , Estudos Retrospectivos , Acetábulo/cirurgia , Acetábulo/lesões , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Resultado do Tratamento , Fraturas Ósseas/cirurgia , Duração da Cirurgia , Adulto Jovem , Desenho de Prótese , Idoso
20.
BMC Surg ; 24(1): 12, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172770

RESUMO

BACKGROUND: Bilateral acetabular fracture is a very rare presentation among the trauma patients, as the pattern and the degree of the forces required to fracture both acetabula is very unique. The primary purpose of this study is to report a series of adult patients presenting with post-traumatic bilateral acetabular fracture without any history of pathological or metabolic bone disease. PATIENTS AND METHODS: In this retrospective study, 18 cases of traumatic bilateral acetabular fracture were included. There was predominance of both column (four patients on left and six on right) followed by anterior column (two patients left and four on right) and posterior wall (three patients left and right). They were treated surgically through open reduction and internal fixation. All cases were followed up for at least 13 months. Matta's criteria were used for radiological evaluation on plain radiographs. Functional outcome was evaluated using the Merle d'Aubigne and postel score at final follow-up. RESULTS: No patients were lost during the follow-up period; there was one case of surgical site infection. There were three cases of postoperative osteoarthritis, one case of heterotrophic ossification, one case of persistent sciatic nerve palsy and one case of lateral femoral cutaneous nerve palsy. The radiological evaluation according to Matta's criteria revealed anatomic reduction in 12 patients, imperfect reduction in three patients while other three patients had poor reduction. According to modified Merle d'Aubigne and Postel score, 10 cases were rated as excellent, five cases as good and three cases presented fair (one case) to poor (two cases) results. CONCLUSION: We report an unusual case series of bilateral acetabular fracture successfully managed surgically with good clinical outcome. With the increasing incidence of route traffic accidents, such cases would probably be recurrent in the upcoming years.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Adulto , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Acetábulo/cirurgia , Acetábulo/lesões , Fixação Interna de Fraturas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA