Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.717
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nano Lett ; 24(27): 8257-8267, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38920296

RESUMO

Osseointegration is the most important factor determining implant success. The surface modification of TiO2 nanotubes prepared by anodic oxidation has remarkable advantages in promoting bone formation. However, the mechanism behind this phenomenon is still unintelligible. Here we show that the nanomorphology exhibited open and clean nanotube structure and strong hydrophilicity, and the nanomorphology significantly facilitated the adhesion, proliferation, and osteogenesis differentiation of stem cells. Exploring the mechanism, we found that the nanomorphology can enhance mitochondrial oxidative phosphorylation (OxPhos) by activating Piezo1 and increasing intracellular Ca2+. The increase in OxPhos can significantly uplift the level of acetyl-CoA in the cytoplasm but not significantly raise the level of acetyl-CoA in the nucleus, which was beneficial for the acetylation and stability of ß-catenin and ultimately promoted osteogenesis. This study provides a new interpretation for the regulatory mechanism of stem cell osteogenesis by nanomorphology.


Assuntos
Diferenciação Celular , Canais Iônicos , Osteogênese , Propriedades de Superfície , Titânio , beta Catenina , Osteogênese/efeitos dos fármacos , Titânio/química , Titânio/farmacologia , beta Catenina/metabolismo , Canais Iônicos/metabolismo , Diferenciação Celular/efeitos dos fármacos , Animais , Proliferação de Células/efeitos dos fármacos , Osseointegração/efeitos dos fármacos , Camundongos , Nanoporos , Nanotubos/química , Humanos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/metabolismo , Fosforilação Oxidativa/efeitos dos fármacos , Próteses e Implantes , Adesão Celular/efeitos dos fármacos
2.
Biochem Biophys Res Commun ; 727: 150316, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38959732

RESUMO

Type 2 diabetes (T2D) is on a notable rise worldwide, which leads to unfavorable outcomes during implant treatments. Surface modification of implants and exosome treatment have been utilized to enhance osseointegration. However, there has been insufficient approach to improve adverse osseointegration in T2D conditions. In this study, we successfully loaded TNF-α-treated mesenchymal stem cell (MSC)-derived exosomes onto micro/nano-network titanium (Ti) surfaces. TNF-α-licensed exosome-integrated titanium (TNF-exo-Ti) effectively enhanced M2 macrophage polarization in hyperglycemic conditions, with increased secretion of anti-inflammatory cytokines and decreased secretion of pro-inflammatory cytokines. In addition, TNF-exo-Ti pretreated macrophage further enhanced angiogenesis and osteogenesis of endothelial cells and bone marrow MSCs. More importantly, TNF-exo-Ti markedly promoted osseointegration in T2D mice. Mechanistically, TNF-exo-Ti activated macrophage autophagy to promote M2 polarization through inhibition of the PI3K/AKT/mTOR pathway, which could be abolished by PI3K agonist. Thus, this study established TNF-α-licensed exosome-immobilized titanium surfaces that could rectify macrophage immune states and accelerate osseointegration in T2D conditions.


Assuntos
Autofagia , Diabetes Mellitus Tipo 2 , Exossomos , Macrófagos , Camundongos Endogâmicos C57BL , Osseointegração , Titânio , Fator de Necrose Tumoral alfa , Titânio/química , Titânio/farmacologia , Animais , Exossomos/metabolismo , Autofagia/efeitos dos fármacos , Macrófagos/metabolismo , Macrófagos/efeitos dos fármacos , Osseointegração/efeitos dos fármacos , Fator de Necrose Tumoral alfa/metabolismo , Fator de Necrose Tumoral alfa/farmacologia , Camundongos , Diabetes Mellitus Tipo 2/metabolismo , Masculino , Células-Tronco Mesenquimais/metabolismo , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Polaridade Celular/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Ativação de Macrófagos/efeitos dos fármacos , Diabetes Mellitus Experimental/metabolismo
3.
Biochem Biophys Res Commun ; 703: 149647, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38350211

RESUMO

The establishment of an osseointegration is crucial for the long-term stability and functionality of implant materials, and early angiogenesis is the key to successful osseointegration. However, the bioinertness of titanium implants affects osseointegration, limiting their clinical application. In this study, inspired by the rapid polarization of macrophages following the phagocytosis of bacteria, we developed bacteroid cerium oxide particles; these particles were composed of CeO2 and had a size similar to that of Bacillus (0.5 µ m). These particles were constructed on the implant surfaces using a hydrothermal method. In vitro experiments demonstrated that the particles effectively decreased the reactive oxygen species (ROS) levels in macrophages (RAW264.7). Furthermore, these particles exerted effects on M1 macrophage polarization, enhanced nitric oxide (NO) secretion to promote vascular regeneration, and facilitated rapid macrophage transition to the M2 phenotype. Subsequently, the particles facilitated human umbilical vein endothelial cell (HUVEC) migration. In vivo studies showed that these particles rapidly stimulated innate immune responses in animal models, leading to enhanced angiogenesis around the implant and improved osseointegration. In summary, the presence of bacteroid cerium oxide particles on the implant surface regulated and accelerated macrophage polarization, thereby enhancing angiogenesis during the immune response and improving peri-implant osseointegration.


Assuntos
Cério , Osseointegração , Animais , Humanos , Macrófagos , Cério/farmacologia , Imunidade Inata , Neovascularização Patológica , Titânio , Osteogênese , Propriedades de Superfície
4.
J Periodontal Res ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38764144

RESUMO

AIMS: To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites. METHODS: Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Outcomes between the test and control implants were statistically compared. RESULTS: The BIC values of the test implants were comparable and non-inferior over the time points studied, except for the 12 weeks time point which showed statistically significantly higher BIC values of the test (88.07 ± 5.35%) compared to the control implants (80.88 ± 7.51%) (p = .010). Similarly comparable and non-inferior were the fBIC values, except for the 6-week outcome, which showed statistically higher values for the test (-546.5 ± 450.80 µm) compared to the control implants (-75.7 ± 100.59 µm). fBIC results for the test implants were qualitatively more stable and consistent between test time points. CONCLUSION: Novel self-cutting bone-level test implants demonstrated superior osseointegration and similar bone levels compared to conventional bone-level implants after a healing period of 12 weeks in healed ridges.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38963167

RESUMO

OBJECTIVE: The aim of this study was to explore the effect of depression and selective serotonin reuptake inhibitors on implant osseointegration and bone healing. METHODS: Forty-eight 6- to 8-week-old SPF Sprague-Dawley male rats were randomly divided into four groups: the Control group, the Fluoxetine group, the Depression group and the De&Flu group. The rats in the Depression group and the De&Flu group were subjected to a depression modelling process, and the rats in the Control group and the Fluoxetine group were raised normally. Then, a titanium implant was placed in the right tibia of each rat. In the Fluoxetine group and De&Flu group, fluoxetine was injected subcutaneously daily, while subcutaneously injecting physiological saline in the Control group and Depression group. Collecting serum from the rats used for ELISA. The surgical area was cut for microcomputed tomography and histology observation. RESULTS: After 12 weeks, bone mineral density was lower in the De&Flu group than in the Control group, Depression group and Fluoxetine group. Bone mineral density was also lower in the Depression group and the Fluoxetine group than in the Control group. The percentage of bone-implant contact (BIC%) in De&Flu rats was lower than in the Control, Depression and Fluoxetine groups. The BIC% in the Depression group and the Fluoxetine group was lower than in the Control group. CONCLUSIONS: Depression and fluoxetine negatively affect bone density and implant osseointegration independently, and this damaging effect is exacerbated when both factors are present. The mechanism may be related to the dysregulation of the hypothalamic-pituitary-adrenal axis and inflammation in the body.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39032079

RESUMO

PURPOSE: To histometrically compare the osseointegration and crestal bone healing of a novel tapered, self-cutting tissue-level test implant with a standard tissue-level control implant in a submerged healing regimen. MATERIALS AND METHODS: In a mandibular minipig model, implants were inserted and evaluated histometrically after a healing period of 3, 6, and 12 weeks. The primary outcome was the evaluation of bone-to-implant contact (BIC) and secondary outcomes were primary stability as per insertion torque and first BIC (fBIC). Outcomes for the test and control implants were compared using Wilcoxon signed-rank tests and mixed linear regression models. RESULTS: Insertion torque values were significantly higher for the test (50.0 ± 26.4 Ncm) compared to the control implants (35.2 ± 19.7 Ncm, p = .0071). BIC values of test implants were non-inferior to those of control implants over the investigated study period. After 12 weeks, the corresponding values measured were 81.62 ± 11.12% and 90.41 ± 4.81% (p = .1763) for test and control implants, respectively. Similarly, no statistical difference was found for fBIC values, except for the 12 weeks outcome that showed statistically lower values for the test (-675.58 ± 590.88 µm) compared to control implants (-182.75 ± 197.40 µm, p = .0068). CONCLUSIONS: Novel self-cutting tissue-level implants demonstrated noninferior osseointegration and crestal bone height maintenance to the tissue-level implants. Histometric outcomes between both implants demonstrated test implants were statistically noninferior to control implants, despite substantial differences in the bone engagement mechanism and resulting differences in insertion torque and qualitative bone healing patterns.

7.
Clin Oral Implants Res ; 35(1): 40-51, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855174

RESUMO

AIM: A new implant system encompassing implants with a tri-oval cross-sectional design and a simplified site preparation protocol at low speed and no irrigation has been developed. The objective of this study was to assess the safety and efficacy of the new implant system using the minipig intraoral dental implant model. METHODS: Eight Yucatan minipigs were included. Twelve weeks after extractions, four implants per animal were randomly placed and allowed to heal transmucosal for 13 weeks: two Ø3.5 × 10 mm implants with a back-tapered collar and circular cross-section (control) and two Ø3.5 × 11 mm implants with tri-oval collar and cross-section (test). MicroCT and histological analysis was performed. RESULTS: Thirty-two implants were placed; one implant for the control group was lost. Histologically, BIC was higher in the test compared with the control group (74.1% vs. 60.9%, p < .001). At the platform level, inflammation was statistically significantly higher albeit mild in the test compared with the control group. No other significant differences were observed between groups. MicroCT analysis showed that bone-to-implant-contact (BIC) and trabecular thickness were statistically significantly higher for the test than the control group. Test group had significantly higher first BIC distance than controls on lingual sites. CONCLUSIONS: The present study results support the safety and efficacy of the new dental implant system and simplified site preparation protocol; human studies should be carried out to confirm these findings.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Animais , Estudos Transversais , Implantação Dentária Endóssea/métodos , Osseointegração , Suínos , Porco Miniatura
8.
Clin Oral Implants Res ; 35(4): 427-442, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38314615

RESUMO

OBJECTIVE: This study aimed to synthesize zinc-incorporated nanowires structure modified titanium implant surface (Zn-NW-Ti) and explore its superior osteogenic and antibacterial properties in vitro and in vivo. MATERIALS AND METHODS: Zn-NW-Ti was synthesized via displacement reactions between zinc sulfate solutions and the titanium (Ti) surface, which was pretreated by hydrofluoric acid etching and hyperthermal alkalinization. The physicochemical properties of the Zn-NW-Ti surface were examined. Moreover, the biological effects of Zn-NW-Ti on MC3T3-E1 cells and its antibacterial property against oral pathogenic bacteria (Staphylococcus aureus, Porphyromonas gingivalis, and Actinobacillus actinomycetemcomitans) compared with sandblasted and acid-etched Ti (SLA-Ti) and nanowires modified Ti (NW-Ti) surface were assessed. Zn-NW-Ti and SLA-Ti modified implants were inserted into the anterior extraction socket of the rabbit mandible with or without exposure to the mixed bacterial solution (S. aureus, P. gingivalis, and A. actinomycetemcomitans) to investigate the osteointegration and antibacterial performance via radiographic and histomorphometric analysis. RESULTS: The Zn-NW-Ti surface was successfully prepared. The resultant titanium surface appeared as a nanowires structure with hydrophilicity, from which zinc ions were released in an effective concentration range. The Zn-NW-Ti surface performed better in facilitating the adhesion, proliferation, and differentiation of MC3T3-E1 cells while inhibiting the colonization of bacteria compared with SLA-Ti and NW-Ti surface. The Zn-NW-Ti implant exhibited enhanced osseointegration in vivo, which was attributed to increased osteogenic activity and reduced bacterial-induced inflammation compared with the SLA-Ti implant. CONCLUSIONS: The Zn-incorporated nanowires structure modified titanium implant surface exhibited improvements in osteogenic and antibacterial properties, which optimized osteointegration in comparison with SLA titanium implant surface.


Assuntos
Implantes Dentários , Nanofios , Animais , Coelhos , Titânio/farmacologia , Titânio/química , Staphylococcus aureus , Antibacterianos/farmacologia , Osseointegração , Bactérias , Zinco/química , Zinco/farmacologia , Propriedades de Superfície , Osteogênese
9.
Artigo em Inglês | MEDLINE | ID: mdl-38804531

RESUMO

OBJECTIVES: The glow discharge plasma (GDP) procedure has proven efficacy in grafting allylamine onto zirconia dental implant surfaces to enhance osseointegration. This study explored the enhancement of zirconia dental implant properties using GDP at different energy settings (25, 50, 75, 100, and 200 W) both in vitro and in vivo. MATERIALS AND METHODS: In vitro analyses included scanning electron microscopy, wettability assessment, energy-dispersive X-ray spectroscopy, and more. In vivo experiments involved implanting zirconia dental implants into rabbit femurs and later evaluation through impact stability test, micro-CT, and histomorphometric measurements. RESULTS: The results demonstrated that 25 and 50 W GDP allylamine grafting positively impacted MG-63 cell proliferation and increased alkaline phosphatase activity. Gene expression analysis revealed upregulation of OCN, OPG, and COL-I. Both 25 and 50 W GDP allylamine grafting significantly improved zirconia's surface properties (p < .05, p < .01, p < .001). However, only 25 W allylamine grafting with optimal energy settings promoted in vivo osseointegration and new bone formation while preventing bone level loss around the dental implant (p < .05, p < .01, p < .001). CONCLUSIONS: This study presents a promising method for enhancing Zr dental implant surface's bioactivity.

10.
Clin Oral Implants Res ; 35(1): 1-20, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37840388

RESUMO

INTRODUCTION: The radiographic examination of alveolar bone using 3D radiographic examination is essential in dental implant treatment planning. Our study aimed to systematically review and quantitatively analyze the correlation between alveolar bone parameters, specifically bone density and cortical bone thickness, assessed using cone beam computed tomography (CBCT) and/or multidetector computed tomography (MDCT); and primary implant stability (PIS) determined using implant stability quotient (ISQ), Periotest® value (PTV), and insertion torque value (ITV). METHODS: This review was registered in the PROSPERO database (registration number CRD42022307245). An electronic literature search was conducted on the PubMed, SCOPUS, and Web of Science databases for papers published until February 2022. The Quality Assessment in Prognostic Studies (QUIPS) tool was used to assess risk of bias. Meta-analyses were conducted to calculate the estimated average correlation coefficient based on a multilevel random-effects model, followed by subgroup analysis. RESULTS: Twenty-six studies were included in this review, consisting of 17 prospective cohort studies, eight retrospective cohort studies, and one nonrandomized controlled trial. A total of 3109 implants placed in 1171 subjects were analyzed. Twenty-three studies were evaluated using meta-analysis. The alveolar bone condition was significantly correlated with ISQ (r = 0.60; p < .001), IT (r = 0.52; p < .001), and PTV (r = -0.42; p < .05). CONCLUSION: Alveolar bone condition is significantly associated with PIS. Low bone density and thin cortical bone can lead to low PIS; therefore, modification of treatment planning and surgical procedures might be needed to avoid poor osseointegration.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Retenção em Prótese Dentária , Humanos , Densidade Óssea , Implantação Dentária Endóssea/métodos , Estudos Prospectivos , Estudos Retrospectivos , Torque
11.
Clin Oral Implants Res ; 35(2): 230-241, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38012845

RESUMO

AIM: The aim of the study was to evaluate the 5 years clinical outcomes associated with implant-level connection (IL) versus abutment-level connection (AL) for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. MATERIALS AND METHODS: Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic (Marginal bone loss) and clinical outcomes (Bleeding on Probing, probing pocket depth, plaque accumulation, incidence of peri-implantitis and peri-implant mucositis as well as prosthetic complications) were collected and compared at 1, 2, 3, and 5 years. A linear mixed model was used to evaluate the differences between groups. RESULTS: Five years after treatment, the MBL change was not significantly different between the groups at any point. The MBL was 0.23 ± 0.64 mm (AL) and 0.23 ± 0.29 mm (IL). The bleeding on Probing was 44% (AL) and 45% (IL) (p = .89). The mean probing depth was 2.91 ± 1.01 mm (AL) and 3.51 ± 0.67 mm (IL). This difference between the groups was statistically significant but clinical insignificant. Presence of plaque was slightly higher (p = .06) in the IL group (34.4%) compared with the AL group (26.3%). The overall technical, biological, and prosthetic complication rates were similar between groups. None of the implants developed peri-implantitis during the entire follow-up period. CONCLUSION: The results of this clinical trial indicated that all clinical and radiographical parameters were clinically comparable between the study groups.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Parafusos Ósseos , Implantes Dentários/efeitos adversos , Peri-Implantite/etiologia
12.
Clin Oral Implants Res ; 35(7): 729-738, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38629945

RESUMO

OBJECTIVES: The present study was conducted to evaluate the reproducibility of Lekholm and Zarb classification system (L&Z) for bone quality assessment of edentulous alveolar ridges and to investigate the potential of a data-driven approach for bone quality classification. MATERIALS AND METHODS: Twenty-six expert clinicians were asked to classify 110 CBCT cross-sections according to L&Z classification (T0). The same evaluation was repeated after one month with the images put in a different order (T1). Intra- and inter-examiner agreement analyses were performed using Cohen's kappa coefficient (CK) and Fleiss' kappa coefficient (FK), respectively. Additionally, radiomic features extraction was performed from 3D edentulous ridge blocks derived from the same 110 CBCTs, and unsupervised clustering using 3 different clustering methods was used to identify patterns in the obtained data. RESULTS: Intra-examiner agreement between T0 and T1 was weak (CK 0.515). Inter-examiner agreement at both time points was minimal (FK at T0: 0.273; FK at T1: 0.243). The three different unsupervised clustering methods based on radiomic features aggregated the 110 CBCTs in three groups in the same way. CONCLUSIONS: The results showed low agreement among clinicians when using L&Z classification, indicating that the system may not be as reliable as previously thought. The present study suggests the possible application of a reproducible data-driven approach based on radiomics for the classification of edentulous alveolar ridges, with potential implications for improving clinical outcomes. Further research is needed to determine the clinical significance of these findings and to develop more standardized and accurate methods for assessing bone quality of edentulous alveolar ridges.


Assuntos
Processo Alveolar , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Reprodutibilidade dos Testes , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/patologia , Análise por Conglomerados , Variações Dependentes do Observador , Arcada Edêntula/diagnóstico por imagem , Radiômica
13.
Artigo em Inglês | MEDLINE | ID: mdl-38819108

RESUMO

OBJECTIVES: The aim of the present study was to compare a novel tapered, double-threaded self-tapping tissue-Level design implant (TLC) to a well-established parallel walled tissue-level (TL) implant in terms of primary and secondary stability over time. MATERIALS AND METHODS: Test TLC (n = 10/per timepoint) and control TL (n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement. Osseointegration and cortical bone maintenance were histologically evaluated by measuring total bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). RESULTS: A significantly higher maximum insertion torque was measured for the test implant TLC compared to the control TL implant (57.83 ± 24.73 Ncm and 22.62 ± 23.16 Ncm, respectively; p < .001). The mean ISQ values were comparable between the two implant types (75.00 ± 6.70 for TL compared to 75.40 ± 3.20 for TLC, p = .988). BIC was comparable between both implant types at each of the evaluated time points. The fBIC was found to be significantly more coronal at 12 weeks for the TLC implant compared to the TL implant (0.31 ± 0.83 mm for TLC compared to -0.22 ± 0.85 for TL, p = .027). CONCLUSION: The novel tapered tissue level design implant showed improved primary stability and an overall improved crestal bone height maintenance compared to the parallel walled design at 12 weeks.

14.
J Biomech Eng ; 146(10)2024 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-38668718

RESUMO

Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50-90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80-90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50-70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60-70% for maximizing osseointegration with current structure and loading.


Assuntos
Análise de Elementos Finitos , Teste de Materiais , Osseointegração , Porosidade , Próteses e Implantes , Fenômenos Mecânicos , Animais , Metais/química , Estresse Mecânico
15.
Skeletal Radiol ; 53(6): 1033-1043, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38044373

RESUMO

Osseointegrated implants have been developed to allow direct skeletal fixation of a prosthesis as an alternative to traditional socket-fitted prostheses for patients who have suffered from a major limb amputation. The implants contribute to improvements in functional outcome and quality of life and radiological evaluation plays a crucial role in pre- and post-operative assessment. This article acts as a guide for radiologists who may be tasked with providing the radiological information required by surgeons and prosthetists. We also look at the radiological appearances of complications that may arise in patients treated with an osseointegrated implant. Plain X-rays are used to screen patients who wish to undergo treatment. Limb-length X-rays are then used to measure the length of any residual bone, and comparisons can be made with the normal side (if present). From this, decisions about the likely size of the implant and the need for further amputation can be made. CT scans enable accurate assessment of the medullary cavity and cortical thickness. Post-operatively, plain X-rays form the mainstay of the routine monitoring of the bone-implant interface. Potential complications include infection, aseptic loosening, mechanical fracture of the implant and periprosthetic fracture. Infection and aseptic loosening can be seen as a lucency at the bone-implant interface which (if left untreated) can lead to loss of the implant. Implant and periprosthetic fractures are radiographically obvious. Radiologists involved in the care of patients undergoing treatment with an osseointegrated implant should become familiar with the imaging requirements so they can contribute to optimal patient outcomes.


Assuntos
Membros Artificiais , Qualidade de Vida , Humanos , Amputação Cirúrgica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Radiologistas , Resultado do Tratamento , Desenho de Prótese
16.
Lasers Med Sci ; 39(1): 162, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38910231

RESUMO

The review critically evaluates the current state of studies investigating laser irradiation for modifying titanium surfaces to enhance the biointegration of dental implants. Laser modification is a rapidly evolving physicochemical surface modification process with the potential to revolutionize dental implant technology. A thorough search of electronic databases, including PubMed, Science Direct, MEDLINE, and Web of Knowledge, was conducted to identify relevant articles. The review focuses on the surface features of laser-modified implants, encompassing in vitro cell culture experiments, rare animal experiments, and limited clinical trials. Of the 26 selected sources, 21 describe surface features, while only two involve in vivo human experiments. The review highlights the lack of long-term clinical experience and calls for further research to mature these technologies. Despite the absence of a consensus on optimal laser types and settings, the overall results are promising, with few negative outcomes. As research in laser irradiation of titanium surfaces progresses, significant advancements in dental implant technology and improved patient well-being are anticipated.


Assuntos
Implantes Dentários , Lasers , Propriedades de Superfície , Titânio , Humanos , Animais , Osseointegração
17.
J Neuroeng Rehabil ; 21(1): 35, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454427

RESUMO

BACKGROUND: Persons with a transfemoral amputation (TFA) often experience difficulties in daily-life ambulation, including an asymmetrical and less stable gait pattern and a greater cognitive demand of walking. However, it remains unclear whether this is effected by the prosthetic suspension, as eliminating the non-rigid prosthetic connection may influence stability and cortical activity during walking. Spatiotemporal and stability-related gait parameters, as well as cortical activity during walking, were evaluated between highly active individuals (MFC-level K3-4) with a TFA and able-bodied (AB) persons, and between persons with a bone-anchored prosthesis (BAP) and those with a socket-suspended prosthesis (SSP). METHODS: 18 AB persons and 20 persons with a unilateral TFA (10 BAP-users, 10 SSP-users) walked on a treadmill at their preferred speed. Spatiotemporal and margin of stability parameters were extracted from three-dimensional movement recordings. In addition, 126-channel electroencephalogram (EEG) was recorded. Brain-related activity from several cortical areas was isolated using independent component analysis. Source-level data were divided into gait cycles and subjected to time-frequency analysis to determine gait-cycle dependent modulations of cortical activity. RESULTS: Persons with TFA walked with smaller and wider steps and with greater variability in mediolateral foot placement than AB subjects; no significant differences were found between BAP- and SSP-users. The EEG analysis yielded four cortical clusters in frontal, central (both hemispheres), and parietal areas. No statistically significant between-group differences were found in the mean power over the entire gait cycle. The event-related spectral perturbation maps revealed differences in power modulations (theta, alpha, and beta bands) between TFA and AB groups, and between BAP- and SSP-users, with largest differences observed around heel strike of either leg. CONCLUSIONS: The anticipated differences in gait parameters in persons with TFA were confirmed, however no significant effect of the fixed suspension of a BAP was found. The preliminary EEG findings may indicate more active monitoring and control of stability in persons with TFA, which appeared to be timed differently in SSP than in BAP-users. Future studies may focus on walking tasks that challenge stability to further investigate differences related to prosthetic suspension.


Assuntos
Amputados , Membros Artificiais , Prótese Ancorada no Osso , Humanos , Marcha , Amputação Cirúrgica , Caminhada , Fenômenos Biomecânicos , Desenho de Prótese
18.
Clin Oral Investig ; 28(1): 89, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217802

RESUMO

OBJECTIVE: To evaluate the osseointegration of implants with hydrophobic (HFB) and hydrophilic (HFL) surfaces in a murine model of high-dose bisphosphonates (BPs). MATERIALS AND METHODS: Sixty-four rats were randomly allocated into four groups: control group with HFB implants (CG-HFB), control group with HFL implants (CG-HFL), BP group with HFB implants (BP-HFB), and BP group with HFL implants (BP-HFL). Animals were euthanized after 15 and 45 days (n=8). The dependent variables assessed were the removal torque (biomechanical analysis), the bone volume around the implants (%BV/TV) (microtomographic analysis), the bone-implant contact (%BIC), the bone between the threads (%BBT) (histomorphometric analysis), and the expression of bone metabolism markers (immunohistochemistry analysis). RESULTS: The CG-HFL and BP-HFL groups presented higher removal torque than the CG-HFB and BP-HFB implants. The %BIC of the CG-HFL surfaces was slightly higher than that of the CG-HFB implants. The BP-HFB and BP-HFL groups presented a higher %BIC than that of the CG-HFB and CG-HFL groups (p<0.001). BP therapy also increased the %BBT at both implant surfaces. Higher levels of ALP were observed in the matrix region of bone tissue on the HFL surfaces than on the HFB surfaces. CONCLUSION: Both surfaces enable osseointegration in rats under BP therapy. CLINICAL RELEVANCE: The study demonstrates that hydrophobic (HFB) and hydrophilic (HFL) implant surfaces can promote osseointegration in rats undergoing bisphosphonate therapy. The HFL surfaces exhibited improved biomechanical performance, higher bone-implant contact, and increased bone volume, suggesting their potential clinical relevance for implant success in individuals on bisphosphonate treatment.


Assuntos
Implantes Dentários , Ratos , Camundongos , Animais , Osteogênese , Difosfonatos/farmacologia , Modelos Animais de Doenças , Propriedades de Superfície , Titânio/química , Osseointegração
19.
Clin Oral Investig ; 28(7): 380, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38886209

RESUMO

OBJECTIVE: To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS: Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS: The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION: The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE: These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.


Assuntos
Cerâmica , Planejamento de Prótese Dentária , Humanos , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Cerâmica/química , Resultado do Tratamento , Adulto , Satisfação do Paciente , Idoso , Estética Dentária , Perda do Osso Alveolar/diagnóstico por imagem , Alvéolo Dental/cirurgia , Alvéolo Dental/diagnóstico por imagem , Falha de Restauração Dentária , Implantes Dentários
20.
Clin Oral Investig ; 28(7): 372, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38872049

RESUMO

OBJECTIVES: Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols. MATERIALS AND METHODS: 36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed. RESULTS: The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 (p = 0.005) and T30-T45 (p = 0.012). Control group showed a significant decrease in ISQ at T30 (p = 0.01) and T45 (p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 (p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG. CONCLUSIONS: The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).


Assuntos
Densidade Óssea , Implantação Dentária Endóssea , Implantes Dentários , Propriedades de Superfície , Torque , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Adulto , Resultado do Tratamento , Osseointegração/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA