Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38810915

RESUMO

BACKGROUND: Inverted-bearing reverse shoulder arthroplasty (IB-RSA) is characterized by a polyethylene glenosphere and a metallic humeral liner to minimize polyethylene wear and debris secondary to impingement between the humerus and glenoid neck. IB-RSA long-term survivorship, complication and revision rates, as well as clinical and radiographic outcomes have not been reported yet. METHODS: This is a monocentric retrospective study on a consecutive series of 151 patients who underwent primary IB-RSA from January 2009 to September 2015 and were evaluated clinically and radiologically at the minimum 8-year follow-up. All complications and reoperations were recorded. Survivorship analysis with any revision surgery as endpoint was done using Kaplan-Meier survival curves. RESULTS: Seventy-eight patients (follow-up rate 51.7%) were reviewed at a mean follow-up of 10.1 ± 1.9 years. At 10 years, the revision-free survival was 98.7% (95% confidence interval: 94.8-99.7). Sixteen complications (10.6%) were observed: 2 axillary nerve injuries, 2 infections, 2 glenoid loosening (which stabilized within 1 year), 2 cases of otherwise unexplained painful stiffness, 4 acromial fractures, 1 post-traumatic scapular pillar fracture, and 3 post-traumatic humeral periprosthetic fractures. Two patients were revised due to infection. No cases of late glenoid loosening and humeral loosening were observed. The revision rate was 1.3%. All the clinical scores and range of motion significantly improved at the last follow-up compared with preoperative status: final Constant score was 66.1 ± 17.4, Subjective Shoulder Value 79.1 ± 20.9, and the American Shoulder and Elbow Surgeons 82.2 ± 17.7. Scapular notching was observed in 51.4% of patients: only 1 case of grade 3 notching was observed in an early glenoid subsidence case. CONCLUSIONS: Primary IB-RSA appears to be a safe and effective procedure and does not present specific implant-associated complications at long-term follow-up. Radiographic analysis showed that inverting the biomaterials leads to a distinct kind of notching with mainly mechanical features.

2.
Int Orthop ; 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39375248

RESUMO

PURPOSE: Scapular Notching (SN) is one of the most common postoperative complications for a patient after Reverse Total Shoulder Arthroplasty (RTSA). Despite employing various strategies to mitigate SN risk, the overall incidence remains far from zero. This article introduces a new risk factor, the scapulo-humeral angle (SHA), as a key element influencing the risk for SN. METHODS: A retrospective analysis was conducted on all patients who underwent RTSA for rotator cuff arthropathy at the study centre. The preoperative SHA was measured, and the presence of SN was investigated and graded using the Nerot classification at the latest follow-up. RESULTS: 42 patients were included. 12 presented SN (incidence 28.5%). A statistically significant Pearson coefficient correlation between pre-operative SHA and the incidence of SN was observed (r= -0.6954; 95% C.I. -0,8250 to -0,4963; p < 0.0001). A statistically significant Pearson coefficient correlation was also found between the degree of SN and the pre-operative SHA (r= -0,7045; 95% C.I. -0,8306 to -0,5096; P value (two-tailed) < 0,0001, alpha 0.05). CONCLUSIONS: The primary finding is a statistically significant correlation between a reduced preoperative SHA and an increased incidence of postoperative SN. The secondary finding is that a smaller preoperative SHA is associated with a more severe degree of SN A SHA cut-off of 50° distinguished patients at high risk of SN from those at low risk. All patients with an SHA below 50° developed SN (10/10), whereas only 6.25% of patients with an SHA exceeding 50° experienced SN (2/32).

3.
Arch Orthop Trauma Surg ; 144(1): 41-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37596498

RESUMO

INTRODUCTION: The role of the subscapularis (Ssc) tendon does not yet have a well-defined role in RSA. The purpose of the present study was to evaluate if the repair of the Ssc in RSA improves overall clinical and radiographic results and if it has the same results using a medialized design humeral stem compared to a lateralized design. METHODS: Eighty-four consecutive patients undergoing RSA were retrospectively analyzed. Nine patients were lost at FU. Two implants with similar glenosphere design and different stem design (medialized and lateralized) were used. The Ssc was repaired in case of good quality of the fibers and reducibility without tension intraoperatively. Patients were divided into four groups for data analysis depending on whether they had received a medialized or lateralized design and Ssc repair or not. Patients were reviewed at an average follow-up of 40.8 ± 13.1 months. Clinical outcome measures included Active range of motion (ROM), strength, visual analog scale (VAS), Constant-Murley score (CMS), and the American Shoulder and Elbow Surgeons score (ASES). Radiographic evaluation at final follow-up was performed to assess scapular notching, stress shielding, and radiolucent lines. RESULTS: No statistically significant clinical differences (p > 0.05) emerged between Lat/Ssc+ and Lat/Ssc-. Conversely, the patients belonging to the Med/Ssc- group reported statistically worse (p < 0.05) results than the Med/Ssc + group in terms of VAS, ASES and CMS. Statistically worse (p < .05) results in the Med/Ssc- group than in the Med/Ssc + were found also in active ROM achieved in FE, ABD, ER1 and ER2, and in the strength obtained in FE, ABD and ER2. Scapular notching was reported in 3 shoulders (15.7%) in Lat/Ssc+ group and in 7 shoulders (50%) in Lat/Ssc- group, while it was reported in 4 shoulders (14.2%) in Med/Ssc + group and in 6 shoulders (42.8%) in Med/Ssc- group. Stress shielding was observed in 6 cases in Lat/Ssc+ group (31.6%), in 8 cases in Lat/Ssc- group (57.1%), in 3 cases (10.7%) in Med/Ssc + group and 4 cases in Med/Ssc- group (28.6%). CONCLUSIONS: Patients undergoing RSA show clinical improvements at mid-term follow-up with a low rate of complications, regardless of the use of a medialized or a lateralized humeral stem design. Ssc repair is associated with better functional outcomes in the cohort of medialized stem, while it did not yield significant differences in the cohort of lateralized stem. LEVEL OF EVIDENCE: Level III; Retrospective Cohort Comparison; Treatment Study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Manguito Rotador/cirurgia , Seguimentos , Amplitude de Movimento Articular , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-39367904

RESUMO

BACKGROUND: Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA). Although the notching rate has reduced significantly thanks to modifications to the surgical technique and humeral and glenoid components, uncontrollable polyethylene (PE)-induced osteolysis can still occur. In contrast to conventional-bearing (CB-RTSA), inverted-bearing RTSA (IB-RTSA) systems, with PE glenospheres and metal or ceramic humeral liners, avoid PE abrasion through scapulohumeral contact. If present, the resulting notch has a different size and configuration than with CB-RTSA. Thus, a modified notching classification seems reasonable. Even in CB-RTSA, the early stages of notching show a different configuration than implied by the established Nerot-Sirveaux classification; therefore, a modification of the classification system is recommended. METHODS: In a prospective multicentre study, 250 cases underwent IB-RTSA. Of these, 39 died, and 28 were lost to follow-up for other reasons, leaving 183 shoulders for the final follow-up examination at a mean of 120.7 months (range 84.1-172.4 months). In the CB-RTSA group, we retrospectively evaluated radiographs of 59 consecutive patients with a follow-up ranging from 2 to 7 years. We analysed the appearance, evolution over time, and location of bone loss on the scapular neck according to the modified Nerot-Sirveaux classification. RESULTS: In IB-RTSA, notching resulted in a new morphological configuration: In contrast to the Nerot-Sirveaux classification, notching began far from the baseplate as an impression or abrasion of the humeral component in the inferior scapular rim. Due to simultaneous mechanical ablation, the defect gradually enlarged, but usually did not contact the baseplate or extend beyond the inferior peg. No signs of PE-induced osteolysis were found. The notching rate reached 19% after 2 years and approached 36% after 10 years. Most shoulders had grade 0 notching (64%), followed by grade 1 (29%); extensive erosion (grade 4) was not observed. In the CB-RTSA group, a small bony impression or erosion without signs of PE-induced osteolysis was observed medial to the scapular neck, without contact with the metaglene in the early phase, which was similar to the impression of the humeral component in IB-RTSA. The notching rate was 86% for CB-RTSA. CONCLUSIONS: A new classification was developed for IB-RTSA, which corresponds to the pathophysiological processes and is compatible with the existing Nerot-Sirveaux classification. Bone erosion in CB-RTSA is not adequately represented by the established classification in the early stages. For this reason, a supplement to the existing classification is presented. LEVEL OF EVIDENCE: Level 4, Case Series, Treatment Study.

5.
Eur J Orthop Surg Traumatol ; 34(2): 1045-1056, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37898968

RESUMO

BACKGROUND: Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival. METHODS: Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1-2 years post-RTSA. RESULTS: Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1. CONCLUSION: The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Prótese Articular , Articulação do Ombro , Prótese de Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Dor de Ombro/cirurgia , Qualidade de Vida , Úmero/cirurgia , Prótese Articular/efeitos adversos , Resultado do Tratamento , Amplitude de Movimento Articular , Estudos Retrospectivos , Cavidade Glenoide/cirurgia
6.
J Shoulder Elbow Surg ; 32(9): e464-e474, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36905950

RESUMO

BACKGROUND: Recently, a stemless reverse shoulder arthroplasty (RSA) design was developed to preserve bone stock. Clinical and radiologic studies of this design in larger cohorts with >100 patients are not frequent. The purpose of this study was to present the clinical and radiologic results of a newly developed stemless RSA implant. The hypothesis was that this design would provide similar clinical and radiologic results to other stemless implants, as well as stemmed implants. METHODS: Between September 2015 and December 2019, all patients who underwent primary RSA with a stemless Easytech prosthesis were considered eligible for inclusion in this prospective multicenter study. The minimum follow-up period was 2 years. Clinical outcomes consisted of the Constant score, adjusted Constant score, QuickDASH (short version of Disabilities of the Arm, Shoulder and Hand questionnaire) score, Subjective Shoulder Value, and American Shoulder and Elbow Surgeons shoulder score. Radiographic parameters included radiolucency, loosening, scapular notching, and specific geometric parameters. RESULTS: Stemless RSA was performed in 115 patients (61 women and 54 men) at 6 different clinical centers. The average age at the time of surgery was 68.7 years. The average Constant score was 32.5 preoperatively and showed significant improvement to 61.8 at latest follow-up (P < .001). The Subjective Shoulder Value also demonstrated significant improvement postoperatively (from 27.0 to 77.5, P < .001). Scapular notching was observed in 28 patients (24.3%); humeral loosening, 5 (4.3%); and glenoid loosening, 4 (3.5%). The total complication rate was 17.4%. Eight patients (4 women and 4 men) underwent implant revision. CONCLUSION: The clinical outcomes of the examined stemless RSA seem to be comparable to those of other humeral designs; however, the complication and revision rates are higher than those of historical controls. Surgeons should proceed with caution when using this implant until longer-term follow-up data are available.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Masculino , Humanos , Feminino , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos
7.
J Shoulder Elbow Surg ; 32(7): 1486-1493, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36690171

RESUMO

BACKGROUND: The most common complication with reverse shoulder arthroplasty Grammont based design with a 155° neck shaft angle (NSA) is scapular notching. Scapular notching has been associated with reduced clinical outcomes. Reducing the humeral NSA from 155° has been shown to reduce the incidence of scapular notching however it is unknown whether there is a difference in scapular notching between a 145° and 135° NSA. The purpose of this study was to evaluate the effect of decreasing the NSA on scapular notching rate and postoperative range of motion comparing 145° and 135° NSA stems at minimum 2 yr of follow-up. METHODS: Consecutive patients undergoing primary reverse shoulder arthroplasty with a NSA of either 145° or 135° between January 2014 and February 2019 were retrospectively reviewed. Patients were included if they were over the age of 18, had minimum clinical follow-up of 24 mo with true postoperative anteroposterior radiographic view. RESULTS: One hundred and three patients were included for the final analysis: 73 with a 145° NSA and 30 with a 135° NSA stem. The mean age and mean follow-up were respectively 70.9 yr (range, 52.0-89.0) and 32.1 mo. The overall incidence of scapular notching was 46.6 %. There was a statistically significant difference in scapular notching between the 145° (53.4%) and 135° (30%) NSA groups (P = .028). There was no difference in terms of postoperative Constant-Murley Score (mean, 66.1 vs. 68.2; P = .395), Subjective Shoulder Value (mean, 76.5 vs. 83.1%, P = .167), forward flexion (mean, 140° vs. 142°, P = .704), abduction (mean, 123.2° vs. 121.5°, P = .771), external rotation with the arm at the side (mean, 34.1° vs. 37.3°, P = .341) and internal rotation (mean, 5.3 vs. 5.4 pts P = .336) between the 2 groups. CONCLUSION: This is the first study to compare the effect of a 145° vs. 135° NSA on scapular notching rates. The key finding of this study is that scapular notching rate was significantly reduced from 53% to 30% in 135° NSA compared to 145° NSA, after at least 24 mo of follow-up. Our data also show that glenoid lateralization and inferiorization has an influence on scapular notching. We are unable to state that the reduced scapular notching rate was due to a reduction in NSA alone. Despite a lower rate of scapular notching, the 135° NSA group has not shown any significant better clinical and functional outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Adulto , Pessoa de Meia-Idade , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Estudos Retrospectivos , Ombro/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-37866752

RESUMO

BACKGROUND: The use of reverse shoulder arthroplasty (RSA) is becoming increasingly prevalent. However, few studies have been published reporting the long-term outcomes of RSA. This study aims to report the clinical, radiographic, and patient-reported outcomes of the Delta Xtend reverse shoulder prosthesis, performed by a single surgeon and with a minimum follow-up of 10 years. METHODS: All RSA procedures performed between 2005 and 2012 were identified. Patients were contacted and invited for a follow-up visit including clinical assessment, radiographs, and patient-reported outcome measures. Patients with a follow-up of less than 10 years were excluded. The revision-free implant survival was calculated at 10 years. Between 2005 and 2012, 119 procedures in 116 patients meeting inclusion criteria were identified. Of these patients, 35 were deceased before reaching the 10-year follow-up and 23 could not be reached. In total, 63 RSAs could be included in 61 patients (response rate: 75%). The median follow-up was 11.7 years (interquartile range [IQR]: 10.5-13.2). RESULTS: Of the 61 patients, 7 patients underwent a revision after a median of 3 years (IQR: 0.2-9.8) during the total follow-up period. The 10-year implant survival was 94% (95% confidence interval: 84-98). At final follow-up, the median anterior elevation was 135° (IQR: 130°-160°), the median abduction was 120° (IQR: 100°-135°), and the median level reached with internal rotation was L5 (IQR: sacrum-L5). The median Auto-Constant score was 68 (IQR: 53-78), the median Subjective Shoulder Value was 80 (IQR: 70-93), and the median pain score was 0.2/10 (IQR: 0-2). In total, radiographs could be obtained in 25 patients (40%). Scapular notching occurred in 10 patients (40%), which was classified as Sirveaux-Nerot grade IV in 3 patients (12%). Ossification occurred in 10 patients (40%), and stress shielding in 2 patients (8%). Radiolucencies were observed around the humeral component in 24 patients (96%) and around the glenoid component in 13 patients (52%). CONCLUSION: The long-term results of RSA with a Delta Xtend prosthesis are favorable, with long-term improvement in range of motion and patient-reported outcome measures, and a satisfactory implant survival rate. Interestingly, the radiographical analysis showed high prevalence of signs associated with loosening, which did not seem to translate to high complication rates or inferior results.

9.
Arch Orthop Trauma Surg ; 143(4): 1809-1816, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35092467

RESUMO

BACKGROUND: The purpose of the present study was to compare the functional and radiographic outcomes following reverse total shoulder arthroplasty (RTSA) in a senior athletic and non-athletic population. MATERIAL AND METHODS: In this retrospective cohort study, patients who underwent RTSA between 06/2013 and 04/2018 at a single institution were included. Minimum follow-up was 2 years. A standardized questionnaire was utilized for assessment of patients' pre- and postoperative physical fitness and sportive activity. Patients who resumed at least one sport were assigned to the athletic group, while patients who ceased participating in sports were assigned to the non-athletic group. Postoperative clinical outcome measures included the Constant score (CS), American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST), and visual analog scale (VAS) for pain. Active shoulder range of motion (ROM) and abduction strength were assessed. Radiographic evaluation was based on a standardized core set of parameters for radiographic monitoring of patients following shoulder arthroplasty. RESULTS: Sixty-one of 71 patients (85.9%; mean age: 72.1 ± 6.6 years) were available for clinical and radiographic follow-up at a mean of 47.1 ± 18.1 months. Thirty-four patients (55.7%) were assigned to the athletic group and 27 patients (44.3%) to the non-athletic group. The athletic group demonstrated significantly better results for CS (P = 0.002), ASES score (P = 0.001), SST (P = 0.001), VAS (P = 0.022), active external rotation (P = 0.045) and abduction strength (P = 0.016) compared to the non-athletic group. The overall rate of return to sport was 78.0% at an average of 5.3 ± 3.6 months postoperatively. Incomplete radiolucent lines (RLL) around the humeral component were found significantly more frequently in the athletic group compared to the non-athletic group (P = 0.019), whereas the occurrence of complete RLLs around the implant components was similar (P = 0.382). Scapular notching was observed in 18 patients (52.9%) of the athletic group and 12 patients (44.9%) of the non-athletic group (P = 0.51). The overall rate for revision surgery was 8.2%, while postoperative complications were encountered in 3.3% of cases. CONCLUSION: At mid-term follow-up, the athletic population demonstrated significantly better clinical results following RTSA without a higher rate of implant loosening and scapular notching when compared to non-athletic patients. However, incomplete radiolucency around the humeral component was observed significantly more often in the athletic group. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Ombro/cirurgia
10.
Arch Orthop Trauma Surg ; 143(8): 4763-4772, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36705760

RESUMO

BACKGROUND: Glenoid defects can be addressed traditionally by asymmetric reaming or by bone-preserving correction to a more lateral joint line by bone or metal augmented baseplates in reverse shoulder arthroplasties. While there is more evidence in literature regarding the outcome and complications of Bony Increased Offset Reversed Shoulder Arthroplasty (BIO-RSA), there is minimal reported experience with the outcome after metal glenoid augments. The aim of this study was to determine whether a metal augment can correct the glenoid deformity in an anatomic manner. METHODS: Glenoid morphology and deformity were determined in 50 patients with Walch type B1, B2, D and Favard type E0-E3 glenoid defects using preoperative radiographic and computed tomography (CT) analysis. All patients received a preoperative planning CT with 3D planning, and measurements of glenoid inclination (in 3 planes proximal, middle, distal), reversed shoulder arthroplasty angle (RSA) and glenoid version were obtained. All patients had a pathologic inclination in the coronal or frontal planes of > 10°. Above the threshold of 10° pathological glenoid version or inclination metal hemi-augments of 10°, 20°, or 30° were used which allow an individual 360° augment positioning according to the patient glenoid deformity. RESULTS: The mean preoperative numbers of the glenoid version demonstrate that most glenoids were in retroversion and superior inclination. In total 2410° wedges, 1820° wedges and 8 30° wedges were used. In the majority of cases, the wedge was positioned posteriorly and/or cranially between 10:00 and 12:00 o'clock, which allows a correction in a 3D manner of the glenoid inclination and version. The mean RSA angle could be corrected from 22.76 ± 6.06 to 0.19° ± 2.7 (p < 0.0001). The highest retroversion of the glenoid is evidenced in the proximal section and it could be corrected from - 23.32° ± 4.56 to - 6.74° ± 7.75 (p < 0.0001) and in the middle section from - 18.93° ± 3.35 to - 7.66° ± 5.28 (p < 0.0001). A mean sphere bone overhang distance (SBOD) of 5.70 ± 2.04 mm was found in order to avoid or minimize relevant scapular notching. CONCLUSION: By using a new 360° metal-augmented baseplate, the preoperative pathological inclination and retroversion can be corrected without medialization of the joint line. Future clinical results will show whether this bone-preserving procedure improves also the clinical outcomes as compared to asymmetric medialized reaming or wedged BIO-RSA. LEVEL OF EVIDENCE: Level IV, Case series.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Artroplastia do Ombro/métodos , Escápula/cirurgia , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos
11.
J Shoulder Elbow Surg ; 31(11): 2410-2420, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35671928

RESUMO

BACKGROUND: Since the introduction of the Grammont-style reverse total shoulder arthroplasty, the humeral stem design has been modified with improved clinical outcomes. Two distinct humeral designs have been used extensively: the inlay design, in which the humeral tray is seated within the metaphysis, and the onlay design, in which the humeral tray sits on the metaphysis at the level of the humeral neck cut. The purpose of this systematic review was to determine whether there are differences in clinical outcomes and complication rates between these designs. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines were used to perform this systematic review. A search of MEDLINE, PubMed, and Embase was performed to identify all studies comparing the clinical results of both humeral designs. Primary outcomes included patient-reported outcome measures, shoulder range of motion, and incidence of complications. RESULTS: From the 156 identified publications, 12 studies were included in the final review. A total of 1447 patients were included, with a minimum follow-up period of 12 months. At final follow-up, both implants demonstrated significant improvements in comparison to preoperative baseline. On comparison of the inlay vs. onlay groups, the American Shoulder and Elbow Surgeons score was higher in the inlay group (mean difference, 2.53 [95% confidence interval, 0.27-4.78]; P = .03). Postoperative motion, even if statistically greater in the onlay group (differences of 5° in forward flexion [P < .001], 3° in abduction [P = .003], and 4° in external rotation [P < .001]), was not clinically different. On comparison of complications, the inlay group showed more instances of scapular notching (93 of 322 patients vs. 70 of 415 patients; odds ratio, 0.35; P < .001) but fewer scapular spine fractures (26 of 727 patients vs. 21 of 559 patients, P = .09). DISCUSSION: Inlay and onlay humeral tray designs in reverse total shoulder arthroplasty demonstrate similar clinical improvements postoperatively. Onlay implants have a low rate of scapular notching but a higher rate of scapular spine fracture. Understanding the strengths and weaknesses of the 2 humeral tray designs is important to provide surgeons with options to tailor surgical plans for high-risk patients.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Úmero/cirurgia , Escápula/cirurgia , Amplitude de Movimento Articular
12.
J Shoulder Elbow Surg ; 31(10): 2106-2115, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35472577

RESUMO

BACKGROUND: Previous studies have demonstrated that decreased impingement-free range of motion (ROM) can adversely influence clinical outcomes following reverse shoulder arthroplasty (RSA). Inferior placement of the glenosphere is thought to minimize impingement and its associated sequelae. This study evaluated the relationship between inferior overhang of the glenosphere and clinical outcomes in patients undergoing primary RSA using a lateralized humeral implant design. METHODS: By use of a prospectively collected shoulder arthroplasty database, all primary RSAs performed at our institution between 2007 and 2015 with a single implant design (lateralized humerus and medialized glenoid) and minimum 2-year follow-up were evaluated. Glenosphere overhang in relation to the inferior rim of the glenoid was measured in millimeters on postoperative Grashey radiographs of the shoulder and categorized into tertiles (low, <7.1 mm; medium, 7.1 to 9.9 mm; and high, >9.9 mm). Clinical outcomes of interest comprised the changes between preoperative and postoperative values in the following ROM and outcome score measures: active forward elevation (aFE), active external rotation, American Shoulder and Elbow Surgeons score, Constant-Murley score, Shoulder Pain and Disability Index score, and Simple Shoulder Test score. Random-effects linear models were used to assess univariate and multivariable associations between overhang tertile and change in patient outcomes. Differences in outcomes were further compared using the minimal clinically important difference (MCID). RESULTS: The study identified 284 shoulders in 265 patients. The median follow-up period was 36 months (range, 24-108 months). The median glenosphere inferior overhang was 8.4 mm, with an interquartile range of 6.3-10.6 mm. Plots demonstrated nonlinear relationships between overhang and outcome scores and between overhang and ROM. Patients with high overhang experienced a significantly greater improvement in aFE compared with patients with low overhang (P = .019), which exceeded the MCID. No other differences in ROM and outcome scores between overhang groups exceeded the MCID. For other outcome scores and ROM measurements, there was no significant relationship with glenosphere overhang. Increased overhang was associated with a significantly lower incidence of scapular notching (P = .005). CONCLUSION: Patients undergoing RSA using a lateralized humerus design with greater inferior overhang of the glenosphere demonstrated a significantly greater improvement in aFE and lower rate of notching compared with those with low overhang. No ideal glenosphere overhang range was identified to maximize function in this study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Artroplastia do Ombro/efeitos adversos , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Resultado do Tratamento
13.
J Shoulder Elbow Surg ; 31(4): 868-874, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34656780

RESUMO

BACKGROUND: Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA). Inverted-bearing RTSA (IB-RTSA) systems, with polyethylene (PE) glenospheres and metal or ceramic humeral liners, reduce notching and PE wear compared with traditional Grammont prosthesis designs. However, whether notching after IB-RTSA influences clinical outcomes or complications remains unknown. Therefore, we evaluated the influence of notching on midterm clinical outcomes and complication rates after IB-RTSA. METHODS: In our prospective multicenter, observational study, patients underwent IB-RTSA, using a prosthesis system with a PE glenosphere and a metal humeral component. We assessed patients clinically for functional scores, active range of motion, and pain and radiographically for notching. RESULTS: Overall, 270 patients (284 shoulders) were treated with IB-RTSA. Of these, 229 shoulders were available for a mean follow-up of 86.7 months (range, 24.0-133.4 months). We observed notching in 35% of shoulders (28% grade 1; 3% grade 2; and 4% grade 3). IB-RTSA led to a distinct type of notching representing the mechanical indent of the humeral component into the scapular neck without PE-induced osteolysis. Patients with and without notching showed similar clinical outcomes (P ≥ .05), complication rates (P = .23), revision rates (P = .87), and survival of implant components after 10 years (P = .85). CONCLUSIONS: Midterm results confirmed our hypothesis that patients with notching had equally good clinical outcomes and low complication rates as patients without notching. Additionally, we found a distinct type of notching without signs of PE-induced osteolysis.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Seguimentos , Humanos , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Resultado do Tratamento
14.
J Orthop Sci ; 2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36437153

RESUMO

BACKGROUND: Although Grammont-style reverse total shoulder arthroplasty (RSA) showed excellent clinical results in Europe, its utility for Asian populations remains unclear. This study aimed to compare the French and Japanese populations in terms of range of motion (ROM), functional outcomes, and scapular notching rates in patients who underwent standard Grammont-style RSA. We hypothesized that RSA for the Japanese population may not provide as good ROM and functional results at the final follow-up as that for the French population. METHODS: A total of 25 Japanese patients undergoing RSA were propensity score matched to 25 French patients undergoing RSA. The patients were matched for four different covariates using a propensity score analysis. The minimum follow-up period was 2 years. We investigated differences between the populations with respect to body size and shoulder joint ROM and Constant score (CS) measured preoperatively and at the final follow-up. Scapular notching was examined using radiographs at the final follow-up. RESULTS: The average height and weight of the French and Japanese patients were 164 cm and 70 kg and 152 cm and 56 kg, respectively. Anterior elevation (AE), external rotation (ER) at the side, internal rotation (IR), and CS total changed from 101° to 145°, 17° to 15°, 4.5 points to 5.5 points, and 36 points to 72 points, respectively, in the French population and from 63° to 119°, 8.5° to 13°, 4.6 points to 4 points, and 28 points to 58 points, respectively, in the Japanese population. AE improved in both the groups; ER and IR remained unchanged before and after surgery. The frequency of scapular notching (>grade 1) was higher in the Japanese population (56%) than in the French population (20%) (p = 0.019). CONCLUSIONS: Grammont-style RSA improved AE and CS in both the populations, but AE and CS were significantly higher in the French population than in the Japanese population at the final follow-up. Scapular notching frequently occurs in the Japanese population.

15.
Arch Orthop Trauma Surg ; 142(12): 3817-3826, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34977963

RESUMO

INTRODUCTION: The employment of reverse shoulder arthroplasty for dislocated proximal humerus fractures of elderly patients becomes increasingly relevant. The standard inclination angle of the humeral component was 155°. Lately, there is a trend towards smaller inclination angles of 145° or 135°. Additionally, there has been an increased focus on the lateralization of the glenosphere. This retrospective comparative study evaluates clinical and radiological results of patients treated for proximal humerus fractures by reverse shoulder arthroplasty with different inclination angles of the humeral component, which was either 135° or 155°. Additionally, a different lateral offset of the glenosphere, which was either 0 mm or 4 mm, was used. METHODS: For this retrospective comparative analysis, 58 out of 66 patients treated by reverse total shoulder arthroplasty for proximal humerus fractures were included. The minimum follow-up was 24 months. Thirty (m = 3, f = 27; mean age 78 years; mean FU 35 months, range 24-58 months) were treated with a standard 155° humeral component and a glenosphere without lateral offset (group A), while 28 patients (m = 2, f = 26; mean age 79 years; mean FU 30 months, range 24-46 months) were treated with a 135° humeral component and a glenosphere with a 4 mm lateral offset (group B). We determined range of motion, Constant score, and the American Shoulder and Elbow Surgeons Shoulder score as clinical outcomes and evaluated tuberosity healing as well as scapula notching. RESULTS: Neither forward flexion (A = 128°, B = 121°; p = 0.710) nor abduction (A = 111°, B = 106°; p = 0.327) revealed differences between the groups. The mean Constant Score rated 63 in group A, while it was 61 in group B (p = 0.350). There were no differences of the ASES Score between the groups (A = 74, B = 72; p = 0.270). There was an increased risk for scapula notching in group A (47%) in comparison to group B (4%, p = 0.001). Healing of the greater tuberosity was achieved in 57% of group A and in 75% of group B (p = 0.142). The healing rate of the lesser tuberosity measured 33% in group A and 71% in group B (p = 0.004). CONCLUSIONS: Both inclination angles of the humeral component are feasible options for the treatment of proximal humerus fractures in elderly patients. Neither the inclination angle nor the lateral offset of the glenosphere seem to have a relevant influence on the clinical outcome. The healing rate of the lesser tuberosity was higher in implants with a decreased neck-shaft angle. There is an increased risk for scapula notching, if a higher inclination angle of the humeral component is chosen. LEVEL OF EVIDENCE: III. Retrospective comparative study.


Assuntos
Artroplastia do Ombro , Fraturas do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Fraturas do Ombro/cirurgia , Úmero/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
16.
Eur J Orthop Surg Traumatol ; 32(2): 307-315, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33880654

RESUMO

PURPOSE: Reverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155° and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135° in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. MATERIAL AND METHODS: For this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m = 11, f = 10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155° humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m = 5, f = 16; mean age 72 years; mean follow-up 34 months) were treated with a 135° humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. RESULTS: The clinical results were similar in both groups concerning the Constant Score (group A = 56.3 vs. group B = 56.1; p = 0.733), the adjusted CS (group A = 70.4% vs. group B = 68.3%; p = 0.589) and the SSV (group A = 72.0% vs. group B = 75.2%; p = 0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction = 98° versus 97.9°, p = 0.655; external rotation with the arm at side = 17.9° versus 18.7°, p = 0.703; external rotation with the arm positioned in 90° of abduction = 22.3° versus 24.7°, p = 0.524; forward flexion = 116.1° versus 116.7°, p = 0.760. The rate of scapular notching was higher (p = 0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A = 48% vs. group B = 38%). CONCLUSION: Theoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155° and a standard glenosphere, implants with a humeral inclination angle of 135° and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Artroplastia do Ombro , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Prótese de Ombro , Idoso , Humanos , Úmero/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos , Artropatia de Ruptura do Manguito Rotador/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
17.
J Shoulder Elbow Surg ; 30(8): e517-e530, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33220411

RESUMO

BACKGROUND: Polyethylene (PE) wear and material degradation have been reported as complications in reverse total shoulder replacements (rTSAs). In this regard, scapular notching is associated with more clinical complications. Therefore, the purposes of the study were to quantify the linear and volumetric wear, as a measure for the amount of removed material, and to qualitatively assess the PE damage modes to describe the material degradation in retrieved rTSA humeral PE inlays that contribute to failure of shoulder replacements. Furthermore, this study aimed to evaluate the effect of scapular notching on PE wear and rim damage of the humeral components. METHODS: The total study population of 39 humeral inlays contains 2 cohorts that were used for the damage mode analysis and for the wear analysis, respectively. The extent and presence of wear damage modes in 5 defined zones were assessed by a grading system for all PE joint replacements. For quantitative wear analysis the most frequent design (n = 17) was chosen. Using a coordinate-measuring machine and postprocessing software, volumetric wear measurements for the retrieved humeral PE inlays were undertaken. Furthermore, prerevision radiographs were analyzed for scapular notching. Finally, retrieval findings were correlated with clinical and radiographic data to consider the effect of notching and to identify risk of failures for these prostheses. RESULTS: Damage on the rim of the humeral PE inlays was more frequent and severe than on the intended articulation surface. Irrespective of the damage mode, the inferior rim zone sustained the greatest amount of wear damage followed by the posterior zone. Burnishing, scratching, pitting, and embedded particles are most likely to occur in the articular surface area, whereas surface deformation, abrasion, delamination and gross material degradation are predominantly present in the inferior and posterior rim zones. The retrieved inlays exhibited a mean volumetric wear rate of 296.9 mm³/yr ± 87.0 mm³/yr. However, if the notched and non-notched components were compared, a significant higher volumetric wear rate (296.5 ± 106.1 mm³/yr) was found for the notched components compared to the non-notched group (65.7 ± 7.4 mm³/yr). Generally, there was a significantly greater incidence of damage and greater amount of wear if scapular notching occurred. CONCLUSION: The notched components showed a 5-fold increase in PE wear rate. Therefore, scapular notching has a strong effect on PE damage and wear. If scapular notching can be clinically avoided, the PE wear performance is in a similar magnitude as found for hip and knee replacements.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Articulação do Ombro , Artroplastia de Substituição/efeitos adversos , Artroplastia do Ombro/efeitos adversos , Humanos , Úmero , Polietileno , Desenho de Prótese , Escápula , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
18.
J Shoulder Elbow Surg ; 30(8): 1899-1906, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33276160

RESUMO

BACKGROUND: The use of an eccentric glenosphere (EG) has been proposed as a way to prevent scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study was to investigate whether the use of an EG decreases scapular notching compared with matched standard concentric glenosphere (CG) controls. METHODS: A retrospective analysis was performed. This study included 49 RSAs with an EG and 49 paired RSAs with a CG with a minimum 60 months of both clinical and radiographic follow-up. Clinical and radiologic outcomes of the EG and CG groups were compared at inclusion and at the last follow-up using the paired Student t test for quantitative data and the χ2 test for qualitative data. Scapular notching was graded according to the Sirveaux classification. Statistical significance was set at P < .05. RESULTS: Notching was observed 2.7 times (95% confidence interval, 1.0-6.8 times) more often in the CG group (P = .037). The difference in notching severity between the groups was not statistically relevant; however, there was a trend toward more severe notching in the CG group (P = .059). Compared with a CG, an EG did not increase the percentage of radiolucent lines around the screws (3% vs. 1.5%, P = .62), around the post (3% vs. 1.5%, P = .62), or below the baseplate (15% vs. 7.5%, P = .18). CONCLUSION: EGs are associated with less notching than CGs. This finding confirms that RSA with an EG is an effective procedure without specific complications at a minimum follow-up of 5 years.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Estudos Retrospectivos , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
19.
J Shoulder Elbow Surg ; 30(11): 2533-2542, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33813010

RESUMO

BACKGROUND: This study aimed to compare the clinical outcomes and radiographic parameters of patients after reverse shoulder arthroplasty (RSA) between the Grammont prosthesis and lateralized humeral design prosthesis. METHODS: A total of 114 patients who underwent RSA with a lateralized humeral design (group L; 71 shoulders) and medialized humeral design (group M; 43 shoulders) prosthesis for cuff tear arthropathy or irreparable rotator cuff tear were enrolled. Clinical outcomes including visual analog scale (VAS), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and Constant scores and range of motion (ROM) were serially followed up at postoperative 3, 6, 12, and 24 months. Radiographic parameters were measured to evaluate preoperative and postoperative status. RESULTS: Both prostheses demonstrated similar clinical outcomes and shoulder function preoperatively and at postoperative 2 years (P >.05). However, patients in group M had significantly better postoperative active forward flexion (postoperative 3 months, 115° ± 12° vs. 101° ± 14°; P <.001; 6 months, 125° ± 13° vs. 118° ± 13°; P <.013) and abduction (3 months, 105° ± 12° vs. 98° ± 12°; P = .002); VAS (3 months, 3.1 ± 1.2 vs. 3.7 ± 1.4; P = .031; 6 months, 2.3 ± 1.1 vs. 2.8 ± 1.3; P = .038); ASES (3 months, 64.2 ± 7.0 vs. 60.4 ± 9.2; P = .022; 6 months, 70.6 ± 6.0 vs. 66.6 ± 8.1; P = .007); and Constant scores (6 months, 59.6 ± 6.9 vs. 55.7 ± 9.3; P = .020). Group L showed a significantly lower rate of scapular notching than group M (15.5% vs. 41.8%; P < .001). The position of the proximal humerus in group L was more lateralized and less distalized than in group M after RSA. CONCLUSIONS: RSA with both the Grammont and lateralized humeral design prostheses provided similar shoulder ROM restoration and functional improvements at a minimum of 2 years. However, patients with a humeral lateralized prosthesis showed slower recovery of shoulder function and ROM up to postoperative 6 months despite a lower incidence of scapular notching.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Próteses e Implantes , Desenho de Prótese , Amplitude de Movimento Articular , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
20.
J Shoulder Elbow Surg ; 30(6): 1273-1281, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33069903

RESUMO

BACKGROUND: In reverse shoulder arthroplasty, Inferior tilt was originally promoted to decrease rates of baseplate failure. However, the literature is conflicting regarding the effect of tilt on scapular neck impingement, which has been associated with an increased risk of notching, increased risk of impingement-related instability, and decreased range of motion. We hypothesized that inferior tilt of -10° would lead to increased medialization and increased scapular neck impingement compared with 0° of tilt. METHODS: Twenty patients without glenoid bone loss undergoing reverse shoulder arthroplasty (RSA) at a single institution underwent computed tomography scans of the entire scapula and proximal humerus for preoperative planning. For each patient, we digitally implanted a 25-mm glenoid baseplate flush with the inferior rim of the glenoid. We then simulated impingement-free range of motion with 16 different implant configurations: glenoid tilt (0° vs. -10°), baseplate lateralization (0 mm vs. +6 mm), glenosphere size (36 mm vs. 42 mm), and neck-shaft angle (135° vs. 145°). The primary endpoint was external rotation with the arm at the side (ERS), which is the primary mode of both notching and impingement-related instability, and the secondary endpoint was adduction (ADD). We recorded the RSA angle, preoperative scapular neck length (SNL), and postoperative SNL. Data were compared by paired t tests and a multivariable regression analysis. RESULTS: In every simulation, inferior tilt led to more impingement on the scapular neck. Inferior tilt of the glenoid component was associated with a mean 27% decrease in impingement-free external rotation (P < .01 in all cases) and a mean 32% decrease in impingement-free ADD (P < .01 in all cases). Inferior tilt removed 3.2 mm of additional SNL (P < .001). Multivariable regression analysis showed that lateralization had the most impact on impingement-free external rotation and ADD (P < .001), followed by glenosphere size (P < .001), neck-shaft angle (P < .001), postoperative SNL (P < .001), glenoid tilt (P = .001), inclination (P < .001), and RSA angle (P = .023 for ERS and P = .025 for ADD). CONCLUSION: Relative to 0° of tilt of the baseplate, inferior tilt of -10° was associated with increased scapular neck impingement in ERS and ADD, likely a result of the increased medialization necessary to seat an inferiorly tilted implant, which shortens the scapular neck and brings the humerus closer to the scapula. This scapular neck impingement increases the risk of notching and impingement-related instability.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Artroplastia , Humanos , Amplitude de Movimento Articular , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA