Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Urol ; 30(1): 7-19, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36194790

RESUMO

Solid-phase single antigen bead (SAB) assay for detection of anti-human leukocyte antigen (HLA) antibodies and high-resolution HLA typing have enabled tremendous progress in virtual crossmatch (VXM) technology in recent years. However, misinterpretation of the SAB assay may result in detrimental consequences after kidney transplantation. Meanwhile, epitope analysis could be an effective method to estimate immunizing eplets, which may provide ancillary information for better understanding of the SAB assay. To perform epitope analysis appropriately, it is necessary to understand the basic principles related to histocompatibility testing and the characteristics of the SAB assay. Therefore, knowledge of the properties and limitations of the SAB assay is critical. In this review, we aim to describe the fundamental concepts regarding immunobiological assessment, including HLA, anti-HLA antibodies, and SAB assay, and explain epitope analysis using examples.


Assuntos
Transplante de Rim , Médicos , Humanos , Epitopos , Antígenos HLA , Transplante de Rim/efeitos adversos , Transplante de Rim/métodos , Rejeição de Enxerto/prevenção & controle
2.
Int J Immunogenet ; 47(3): 227-234, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32390325

RESUMO

Humoral alloimmunity mediated by anti-human leucocyte antigen (HLA) antibodies is a major challenge in kidney transplantation and impairs the longevity of the transplanted organ. The immunological risk of an individual patient is currently mainly assessed by detection of HLA antibodies in the serum, which are produced by long-lived bone marrow-residing plasma cells. However, humoral alloimmunity is complex, and alloreactive memory B cells constitute an additional factor in the interplay of immune cells. These recirculating "silent" cells are responsible for the immunological recall response by differentiating into antibody-producing cells upon antigen re-encounter. Historically, due to the lack of appropriate and routinely applicable assays to determine the presence and HLA specificity of alloreactive memory B cells, their contribution to the humoral alloimmune response has clinically often been suspected but could not be determined. In this review, we give an overview of recent advances in techniques to detect alloreactive memory B cells and discuss their strengths and limitations. Furthermore, we summarize experiences with these techniques in alloimmunized individuals and transplant recipients, thereby emphasizing unmet needs to be addressed in future studies.


Assuntos
Linfócitos B/imunologia , Rejeição de Enxerto/imunologia , Antígenos HLA/imunologia , Transplantes/imunologia , Rejeição de Enxerto/patologia , Histocompatibilidade/imunologia , Humanos , Imunidade Humoral/imunologia , Memória Imunológica/imunologia , Isoanticorpos/imunologia , Transplante de Rim/efeitos adversos , Transplantados
3.
J Clin Lab Anal ; 32(2)2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28444979

RESUMO

BACKGROUND: Bead based flow cytometry and Luminex play a major role in identification of alloantibodies in renal transplant work-up. Strong sensitization events may lead to prozone phenomenon that can affect single antigen bead (SAB) assay and result in false negativity. However, this can also be due to high titer of other blocking antibodies. While methods like, heat inactivation, C1 inhibitor, Ethylene diamine tetra-acetic-acid and Dithio threitol treatment can remove interfering antibodies of complement and IgM, these methods are not optimal if false negativity is due to prozone effect, which is high titer of antibodies alone. METHODS: We hereby present a case of a highly sensitized renal transplant recipient with 64% panel reactive antibody positivity (PRA) and a subsequent negative SAB assay. This paradoxical finding hinted at SAB being a false negative result and serial dilutions were used to perform further tests. RESULTS: Serum dilutions lead to positive flow based panel reactive antibody (PRA) and flow cytometry crossmatch (FCXM), with an increasing trend in FCXM. CONCLUSIONS: In highly sensitized patients serial dilution should be considered during a transplant work-up to avoid missing any underlying antibodies. Serum dilution can be used as first option to circumvent prozone. Also, interference of other antibodies should not be labeled as prozone effect.


Assuntos
Antígenos HLA , Teste de Histocompatibilidade , Adulto , Reações Falso-Negativas , Citometria de Fluxo , Antígenos HLA/sangue , Antígenos HLA/classificação , Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Teste de Histocompatibilidade/normas , Humanos , Isoanticorpos/sangue , Transplante de Rim , Masculino
4.
Eur J Immunol ; 45(7): 2111-21, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25824860

RESUMO

Anti-HLA donor-specific antibodies are deleterious for organ transplant survival. Class I HLA donor-specific antibodies are identified by using the Luminex single antigen beads (LSAB) assay, which also detects anti-denatured HLA antibodies (anti-dHLAs). Anti-dHLAs are thought to be unable to recognize native HLA (nHLA) on the cell surface and therefore to be clinically irrelevant. Acid denaturation of nHLA on LSAB allows anti-dHLAs to be discriminated from anti-nHLAs. We previously defined a threshold for the ratio between mean fluorescence intensity against acid-treated (D for denaturation) and nontreated (N) LSAB, D ≥ 1.2 N identifying the anti-dHLAs. However, some anti-dHLAs remained able to bind nHLA on lymphocytes in flow cytometry crossmatches, and some anti-nHLAs conserved significant reactivity toward acid-treated LSAB. After depleting serum anti-nHLA reactivity with HLA-typed cells, we analyzed the residual LSAB reactivity toward nontreated and acid-treated LSABs, and then evaluated the ability of antibodies to recognize nHLA alleles individually. We observed that sera can contain mixtures of anti-nHLAs and anti-dHLAs, or anti-nHLAs recognizing acid-resistant epitopes, all possibly targeting the same allele(s). Therefore, the anti-HLA antibody response can be highly complex and subtle, as is the accurate identification of pathogenic anti-HLA antibodies in human serum.


Assuntos
Aloenxertos/imunologia , Epitopos , Antígenos de Histocompatibilidade Classe I/genética , Antígenos de Histocompatibilidade Classe I/imunologia , Imunologia de Transplantes/imunologia , Anticorpos/imunologia , Epitopos/imunologia , Citometria de Fluxo , Sobrevivência de Enxerto/imunologia , Humanos , Transplante de Órgãos
5.
Transpl Int ; 29(9): 988-98, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27103066

RESUMO

Clinical relevance of ELISA- and single-antigen bead assay (SAB)-detected pretransplant HLA antibodies (SAB-HLA-Ab) for kidney graft survival was evaluated retrospectively in 197 patients transplanted between 2002 and 2009 at the University Clinic Frankfurt. Having adjusted for retransplantation and delayed graft function, a significantly increased risk for death-censored graft loss was found in patients with pretransplant SAB-HLA-Ab [HR: 4.46; 95% confidence interval (CI): 1.47-13.48; P = 0.008]. The risk for increased graft loss was also significant in patients with pretransplant SAB-HLA-Ab but without SAB-detected donor-specific Ab (SAB-DSA) (HR: 4.91; 95% CI of 1.43-16.991; P = 0.012). ELISA was not sufficient to identify pretransplant immunized patients with an increased risk for graft loss. In immunized patients, graft loss was predominantly present in patients who received transplants with a mismatch on the HLA-DR locus. In conclusion, even if our study is limited due to small sample size, the results show an increased risk for long-term graft loss in patients with pretransplant SAB-HLA, even in the absence of DSA. SAB-HLA-Ab-positive patients, being negative in ELISA or CDC assay, might profit from a well-HLA-DR-matched graft and intensified immunosuppression.


Assuntos
Anticorpos/sangue , Sobrevivência de Enxerto , Antígenos HLA/imunologia , Transplante de Rim , Insuficiência Renal/cirurgia , Adulto , Idoso , Biópsia , Função Retardada do Enxerto/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunização , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Proteinúria/sangue , Insuficiência Renal/imunologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Doadores de Tecidos
6.
Hum Immunol ; 85(5): 110857, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39096533

RESUMO

Compromised detection of HLA specific antibodies due to complement mediated interference (CMI) is a well-recognized limitation of the single antigen bead (SAB) assay. Serum treatment with EDTA prior to SAB assay testing is a common strategy used to prevent CMI, however, treatment of individual sera, especially in large clinical runs, can extend assay turnaround time and increase the risk of a sample mix-up. In this study, we describe a simplified EDTA treatment strategy that can be applied simultaneously to all sera in a testing run. This strategy effectively prevents CMI without added pipetting steps and the increased turnaround time associated with other strategies. In the novel bead treatment (BT) method, EDTA solution and SAB suspension are combined and added into the wells of a testing tray together, patient sera are then added to the SAB/EDTA mixture. This eliminates the separate EDTA pre-treatment step used in the standard procedure (ST). Parallel testing using the BT, ST, and no EDTA treatment strategies followed by antibody identification using the Rapid Optimized SAB (ROB) protocol was performed for 19 well characterized sera with known CMI at two different laboratories. Both BT and ST methods were equally effective in preventing CMI. In addition, excellent MFI correlation was observed for specificities not affected by CMI. Both negative and pooled positive control sera performed as expected using the BT method and the pooled positive control serum, specifically designed to exhibit CMI, served well as an EDTA treatment control for all sera. The modified BT protocol can be easily implemented for clinical testing and eliminates extra pipetting steps, reduces the likelihood of pipetting error, and decreases turnaround time, while effectively preventing CMI and ensuring accurate detection of HLA antibodies. This protocol was recently implemented in the Halifax HLA Laboratory and has been very positively received by the laboratory team.


Assuntos
Ácido Edético , Antígenos HLA , Teste de Histocompatibilidade , Humanos , Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Proteínas do Sistema Complemento/imunologia , Isoanticorpos/imunologia , Isoanticorpos/sangue
7.
HLA ; 102(5): 557-569, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37130801

RESUMO

Luminex single antigen bead (SAB) kits from One Lambda (OL) and Lifecodes (LC) are widely used for HLA antibody detection but have substantial differences in design and assay protocol resulting in different mean fluorescence intensity (MFI) values. Here, we present a non-linear modeling approach to accurately convert MFI values between two vendors and to establish user-independent MFI cutoffs when analyzing big datasets. HLA antibody data from a total of 47 EDTA-treated sera tested using both OL and LC SAB kits were analyzed. MFI comparisons were made for the common 84 HLA class I and 63 class II beads. In the exploration set (n = 24), a non-linear hyperbola model on raw MFI corrected by locus-specific highest self MFI subtraction yielded the highest correlation (class I r2 : 0.946, class II r2 : 0.898). Performance of the model was verified in an independent validation set (n = 12) (class I r2 : 0.952, class II r2 : 0.911). Furthermore, in an independent cohort of post-transplant serum samples (n = 11) using the vendor-specific MFI cutoffs dictated by the current model, we found 94% accuracy in bead-specific reactivity assignments by the two vendors. We recommend using the non-linear hyperbola modeling approach with self HLA correction and locus-specific analyzes to harmonize MFI values between two vendors in particular research datasets. As there are considerable variations between the two assays, using MFI conversion for individual patient samples is not recommended.


Assuntos
Antígenos HLA , Transplante de Rim , Humanos , Alelos , Anticorpos , Teste de Histocompatibilidade/métodos , Transplante de Rim/métodos , Isoanticorpos , Rejeição de Enxerto
8.
Indian J Nephrol ; 33(3): 170-176, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37448891

RESUMO

Introduction: Recipient sensitization against donor human leukocyte antigens (HLA) plays a key role in transplant rejection, and this risk is best minimized by efficient pre transplant antibody detection. Determination of antibody specificity with the highest sensitivity and degree of resolution to the allelic antigen level is achieved by using single-antigen bead (SAB) assay. Methods: This study evaluated the correlation of Luminex cross match (LXM) with SAB assay for detection of donor-specific antibodies (DSA). A total of 2075 renal transplant patients were screened for the presence of DSA by LXM, complement-dependent cytotoxicity (CDC) cross match, and 125 patients for SAB from January 2018 to December 2019. Results: There was a male preponderance among recipients (P < 0.0001), and the most affected age group was 21-40 years. HLA typing was done in 550/2075 by DNA PCR-reverse sequence-specific oligonucleotide probes (SSOP) method. HLA DSA by LXM was detected in 16.3% of recipients (338/2075). Majority 180/338 (53.2%) of the patients were class II DSA positive, (P < 0.0001). Among the class II DSA positive patients, 20/180 (11.1%) samples gave false-positive results by LXM. SAB for class I and class II HLA IgG antibodies was done in 125/338 renal transplant recipients, which included 20 recipients with false-positive class II Luminex DSA, to check whether the DSA detected were really donor specific or not. The results showed that although 20/125 patients had some antibodies detected in their serum, they were not against the donor HLA antigens, as per the HLA typing reports of the donors. When compared to SAB assay, LXM showed more discrepant results, particularly to class II DSA. Conclusion: In conclusion, LXM, if used in combination with SAB assay and HLA typing of donors if necessary for virtual cross match, will help in avoiding unnecessary exclusion of donors for renal transplant recipients and also for post transplant monitoring of recipients, especially in cadaveric donor transplants.

9.
HLA ; 99(6): 573-579, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35411722

RESUMO

Complement-mediated interference is a well described phenomenon in single antigen bead (SAB) Luminex assay that leads to falsely low or negative results for anti-HLA antibody (Ab). In a context of high amount of Ab, the enrichment of the Ab around the bead can lead to complement cascade activation and deposition, thereafter impairing Ab detection. EDTA is now routinely used to circumvent this interference. In this report, we attempted to decipher the role of the phycoerythrin (PE) label conjugated to the secondary Ab in this interference. Indeed, PE is a huge molecule (240 kDa) that could participate to limiting access of the conjugate to its Ab target on the bead. To this purpose, 22 sera displaying complement interference without pre-treatment with EDTA were compared on SAB assay with three detection strategies: the recommended PE-conjugated secondary Ab (IgGPE), an Alexa Fluor 532-conjugated Ab (IgGAF) bearing a tiny 724 Da fluorochrome, and a biotinylated Ab followed by PE-conjugated streptavidin (IgGBiot). Complement interference occurred with the three detection methods, but its depth, defined by the percentage of MFI loss with neat serum, was the highest for IgGPE. Our study highlighted the partial role of the PE fluorochrome in complement interference in SAB assays.


Assuntos
Antígenos HLA , Isoanticorpos , Alelos , Proteínas do Sistema Complemento , Ácido Edético , Corantes Fluorescentes , Teste de Histocompatibilidade/métodos , Humanos , Ficoeritrina
10.
Transpl Immunol ; 74: 101672, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35868613

RESUMO

BACKGROUND: It is controversial whether all donor-specific antibodies (DSA) detected by the solid-phase single antigen bead (SAB) assay negatively affect kidney transplantation outcomes. The study aimed to evaluate the possible clinical significance of low pre-transplant DSA in living donor kidney recipients. We analyzed a group of patients with HLA-A, B, and -DR DSA reactivities below a virtual crossmatch (VXM) value of 5000 MFI but with all VXM DSA reactivities at HLA-DQ, -DP, and -Cw, which were not typed routinely for donors prior to transplantation. We also investigated the incidence of persistent and de novo DSAs in available posttransplant SAB assays. METHODS: From the historical cohort of living donor recipients transplanted between 2014 and 2018 at our center (n = 82), 55 patients met the inclusion criteria, namely: these patients were > 18 years old with non-HLA identical sibling donors, who were not desensitized, who had available pre-transplant SAB results, and who had negative both complement-dependent cytotoxicity crossmatch (CDCXM) and flow cytometry crossmatch (FLXM) results. An additional donor HLA typing, performed for all 55 recipients, identified donor additional HLA-DQ, -DP, and -Cw DSA reactivities. These patients were then divided by SAB reactivity into three groups: 1) those with DSA-positive reactivities; 2) those with non-donor-specific anti-HLA reactivities (NDSA); and, 3) those who were anti-HLA-negative. All these recipients were followed for three years and checked for their de novo or persistent DSA. RESULTS: In the studied cohort, DSA-positive, NDSA reactive, and anti-HLA negative recipients constituted 33%, 36%, and 31% of 55 patients, respectively. Non-routinely considered pre-transplant HLA-DQ, -DP, and -Cw DSA-positive reactivities were shown in as many as 78% of DSA-positive cases (group 1) with the lowest MFI value of 319 to DP4 and the highest MFI of 5767 to DQ2. Of the pre-transplant HLA-A, B, and -DR DSA reactivities, only -DR52 DSA reactivity reached the highest MFI value of 2191. These detected DSAs did not reduce the mean estimated glomerular filtration rate (eGFR) values and did not increase the incidence of proteinuria in recipients. While the 3-year graft survival was lower in the DSA-positive group (94.4%) with one recipient who lost kidney transplant, the difference was not significantly different (p = 0.7) from the NDSA (100%) and negative (100%) groups. In terms of the incidence of de novo acute antibody-mediated rejection (AMR) at three years after transplantation, no case has been reported in the cohort. This may suggest that low DSA-positive recipients do not experience higher rejection rate. However, DSA-positive recipients had a tendency for a higher frequency of C4d deposits in peritubular capillaries (PTC) and de novo DSA. CONCLUSION: Our 3-year follow-up of patients with low pre-transplant DSA found no association with a deterioration in graft function and worse graft survival. Furthermore, we did not observe an increase in AMR in our patients with low DSA. A larger cohort and a longer follow-up period may be needed to evaluate the tendency of low DSA-positive recipients towards the higher incidence of C4d deposits in PTC and/or de novo DSA.


Assuntos
Rejeição de Enxerto , Antígenos HLA , Adolescente , Anticorpos , Citometria de Fluxo , Antígenos HLA-A , Antígenos HLA-DQ , Teste de Histocompatibilidade/métodos , Humanos , Isoanticorpos , Rim , Doadores Vivos , Estudos Retrospectivos , Doadores de Tecidos
11.
Front Genet ; 13: 1059650, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36531234

RESUMO

The single antigen bead (SAB) assay is the most used test for the identification of HLA specific antibodies pre- and post-transplant. Nevertheless, detection of spurious reactivities remains a recognized assay limitation. In addition, the presence of weak reactivity patterns can complicate unacceptable antigen assignment. This work presents the evaluation of the adsorption with crossmatch cells and elution (AXE) technique, which was designed to help differentiate weak HLA specific antibodies targeting native antigens from spurious and background SAB assay reactivity. The AXE protocol uses selected donor cells to adsorb HLA specific antibodies from sera of interest. Bound antibodies are then eluted off washed cells and identified using the SAB assay. Only antibodies targeting native HLA are adsorbed. Assay evaluation was performed using five cell donors and pooled positive control serum. AXE efficiency was determined by comparing SAB reactivity of adsorbed/eluted antibody to that of the antibodies in unadsorbed sera. A robust efficiency was seen across a wide range of original MFI for donor specific antibodies (DSA). A higher absorption/elution recovery was observed for HLA class I antigens vs. class II. Locus-specific variation was also observed, with high-expression HLA loci (HLA-A/B/DR) providing the best recovery. Importantly, negligible reactivity was detected in the last wash control, confirming that AXE eluates were not contaminated with HLA antibody carry-over. Donor cells incubated with autologous and DSA-containing allogeneic sera showed that AXE selectively adsorbed HLA antibodies in a donor antigen-specific manner. Importantly, antibodies targeting denatured epitopes or other non-HLA antigens were not detected by AXE. AXE was particularly effective at distinguishing weak HLA antibodies from background reactivity. When combined with epitope analysis, AXE enhanced precise identification of antibody-targeted eplets and even facilitated the characterization of a potential novel eplet. Comparison of AXE to flow cytometric crossmatching further revealed that AXE was a more sensitive technique in the detection of weak DSA. Spurious reactivities on the current SAB assay have a deleterious impact on the assignment of clinically relevant HLA specificities. The AXE protocol is a novel test that enables users to interrogate reactive patterns of interest and discriminate HLA specific antibodies from spurious reactivity.

12.
Kidney Int Rep ; 7(6): 1179-1188, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35685330

RESUMO

Human leukocyte antigens (HLAs) are the primary determinants of alloimmunity. A crossmatch test is a test that determines the immunologic risk of a recipient with a potential donor by ensuring that there are no transplant-relevant circulating antibodies in the recipient directed against donor antigens. Physical crossmatch (PXM) tests, such as complement-dependent cytotoxicity crossmatch (CDCXM) and flow cytometry crossmatch (FCXM), require mixing of patient serum and donor cells, are labor intensive, and are logistically challenging. Virtual crossmatch (VXM) test assesses immunologic compatibility between recipient and potential donor by analyzing the results of 2 independently done physical laboratory tests-patient anti-HLA antibody and donor HLA typing. The goal of VXM is pretransplant risk stratification-though there is no consensus on whether such risk assessment involves predicting the PXM result or the posttransplant outcome. Although the concept of VXM is not new, the advent of solid-phase assays for detecting circulating antibodies in the recipient directed against individual HLA and DNA-based methods for typing donor HLA specificities at a higher resolution makes the routine use of VXM a reality. Accordingly, VXM may be applied at different scenarios-both for sensitized and nonsensitized patients. Implementation of VXM-based approach has resulted in statistically significant reduction in cold ischemia time without an increase in hyperacute rejection episodes. Though there are considerable challenges, VXM is expected to be used more often in the future, depending on the transplant center's tolerance of immunologic risk.

13.
Asian J Transfus Sci ; 16(2): 180-185, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36687549

RESUMO

BACKGROUND: Human leukocyte antigen (HLA) is a major determinant in deciding upon solid organ histocompatibility. Donor-specific anti-HLA antibodies (Donor-specific anti-HLA antibodies (DSAs)) are always a contraindication for solid organ transplantation, and identification of DSA becomes very crucial before transplantation to provide long-term graft survival. For identification of DSA, usually, either cell-based or HLA bead-based assay is being used in laboratories. However, both cell-based and bead-based assays have certain limitations. One such common limitation is "prozone effect," which can give false-negative results. Here, we would like to present a small pilot study to analyze the effect of the prozone phenomenon in the cell-based and HLA bead-based assays and its utility in histocompatibility testing. MATERIALS AND METHODS: In a series of four experiments, cell-based assay, flow cytometric cross-match (FCXM), and HLA bead-based flow cytometric panel reactive antibodies (PRAs) were performed. Single-antigen bead (SAB) testing was conducted as a first experiment on four known positives samples for anti-HLA antibody-antibodies. In the second experiment, these four samples were pooled together (called pooled sera in the text) and tested for FCXM and PRA. In the third experiment, known commercially available positive control sera were mixed with pooled positive sera (positive control sera + pooled sera) to prepare, what we have called "positive concoction" in the text. In the fourth experiment, the positive concoction was diluted serially (1:2, 1:4, 1:8, and 1:16) and FCXM and PRA were performed again to analyze and compare the prozone effect. RESULTS: Pooled sera did not have the expected median fluorescence intensity (MFI) values in FCXM assay, whereas the PRA was showing >90% positivity. In positive concoction, the MFI of FCXM assay was observed to be declining; however, PRA values remained almost constant. Dilutions of the pooled sera showed that MFI values of FCXM assays were increased suddenly after dilution. The highest MFI values were observed in 1:4 dilution of the sera, and then, it declined gradually, but the PRA values remained almost constant even after serial dilutions. CONCLUSION: In our experimental findings, it was clear that cell-based assay (FCXM) was more severely affected by the prozone, whereas solid-phase (flow PRA) assay remained resistant to prozone.

14.
Indian J Nephrol ; 31(3): 240-244, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34376937

RESUMO

INTRODUCTION: Solid organ transplantation is the preferred therapeutic modality of treatment in patients affected by terminal organ failures. Human leukocyte antigens (HLAs) plays an important role in graft survival. In many of the cases of rejection, antibodies are directed against HLA antigens expressed on the cells of the transplanted organ. Pre-transplant compatibility testing involves the use of different methodologies for the determination of anti-HLA antibodies. Luminex single-antigen bead (SAB) assay demonstrates higher sensitivity and specificity in detecting anti-HLA antibodies. The aim of this study was to determine the prevalence of anti-HLA antibodies in pre-transplant work up recipients, planned for renal transplant at a tertiary care center in India. METHODS: 1640 patients visiting tertiary care hospital for pre-transplant compatibility testing were screened with complement-dependent micro-lymphocytotoxicity crossmatch (CDC-XM) and flow cytometric crossmatch (FC-XM). The patients positive for either or both screening tests were assayed with the Luminex SAB tests in order to establish defined antigen specificity of the alloantibodies and determining donor-specific antibody (DSA). RESULTS: The two most frequent antibodies identified in each A, B, C locus of HLA class I were -A*24:03 (43.9%), A*25:01 (36.6%), B*57:01 (40.3%), B*15:12 (37.1%), C*17:01 (61.9%), C*07:01 (52.4%) and in DR, DQ DP locus in HLA class II were DRB1*09:01(40.0%), DRB1*14:04(37.6%), DQA1*04:01/DQB1*03:03 (58.4%), DQA1*05:01/DQB1*03:01 (55.1%), DPA1*02:01/DPB1*17:01 (55.0%), DPA1*02:01/DPB1*05:01 (45.0%). CONCLUSION: This study has found the prevalence and specificity of anti-HLA antibodies in north India.

15.
Transpl Immunol ; 65: 101349, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33127497

RESUMO

INTRODUCTION: Detection of donor specific antibodies (DSA) is critical in both solid organ and mismatched haematopoietic stem cell transplants. The single antigen bead assay (SAB) is widely used as a virtual crossmatch in these settings. However, HLA allele variation across ethnicities and differing genetic backgrounds is a well-known and acknowledged fact and representation of alleles prevalent in a population is key while using a virtual crossmatch as a sole decision making tool. Against this background, this study was performed to assess the feasibility of using the SAB as a single tool to identify DSA in our population. MATERIALS AND METHODS: The HLA alleles identified in the study population were analysed to assess their representation on SAB panels from two different vendors. RESULTS: The study population comprised of a total of 966 subjects for whom 6 loci high resolution HLA typing was done. A total of 241 different alleles were assigned in the population. Among the 241 alleles identified in our study population, 48.55% (n = 117) alleles were represented in the SAB A panel and 48.13% (n = 116) represented in the SAB B panel. Unrepresented alleles were 51.45% (n = 124) in panel A and 51.87% (n = 125) in panel B. All the twelve alleles were represented for 16.05% (n = 155) and 16.25% (n = 157) of study population in panel A and in panel B respectively. The remaining individuals (83.95%, (n = 811) in panel A and 83.75%, (n = 809) in panel B) had at least one allele unrepresented. CONCLUSION: Our study addresses an important limitation in utilizing the SAB as a single tool to identify DSA, owing to non-representation of locally prevalent / unique alleles in our population. More than 50% of alleles were unrepresented in both the SAB assays we studied, which included alleles from both Class I and Class II. We recommend therefore that, until a comprehensive coverage of alleles is provided, or epitope matching becomes robust, that the SAB be combined with a physical crossmatch when mismatched alleles are not represented.


Assuntos
Soro Antilinfocitário , Antígenos HLA , Antígenos HLA/genética , Teste de Histocompatibilidade , Humanos , Isoanticorpos , Atenção Terciária à Saúde , Doadores de Tecidos
16.
Hum Immunol ; 82(6): 409-413, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33875298

RESUMO

The single-antigen bead assay (SABA) demonstrates high sensitivity and specificity for detecting anti-human leukocyte antigen (HLA) antibodies. However, SABA may produce false-positive results for anti-HLA antibodies. Herein, we analyzed the data of patients with complement-dependent cytotoxic crossmatch-/flow cytometric crossmatch-/SABA+/- results to determine false-positive results for anti-HLA antibodies. We also determined the prevalence of false-positive results by comparing false-positive data from our laboratory and national allele frequency data obtained with high-resolution HLA typing. For HLA-A, -B, -C, and -DR, a ratio of positive frequency to allele frequency of ≥3 in our laboratory was considered a false-positive result. For HLA-DQA1/DQB1 and HLA-DPA1/DPB1, we considered the positive frequency of ≥3 as a false positive result due to lack of haplotype frequency data. SABA results from 284 patients (78.0%) demonstrated false reactivity. The antibody against HLA-C*17:01 displayed the highest frequency ratio (298.3). If false-positive reactivity is suspected, results should be confirmed using different methods. If confirmation tests are unfeasible, comparing the allele frequency with the positive rate of detected anti-HLA antibodies and using a ratio ≥3 may facilitate the interpretation of SABA results. The positive rate of anti-HLA antibodies can be validated using the HLA allele frequency of the population to determine false-positive results.


Assuntos
Anticorpos/metabolismo , Antígenos HLA/genética , Separação Imunomagnética/métodos , Proteínas do Sistema Complemento/metabolismo , Reações Falso-Positivas , Frequência do Gene , Antígenos HLA/imunologia , Teste de Histocompatibilidade , Humanos , Transplante de Órgãos , Sensibilidade e Especificidade
17.
Transpl Immunol ; 67: 101407, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33975014

RESUMO

Female recipients of a spousal donor kidney transplant are at greater risk of donor-specific pre-immunization, which may increase the risk of acute antibody-mediated rejection (ABMR). We assessed the incidence of early ABMR (within two weeks after transplantation), risk factors for ABMR and graft function in 352 complement-dependent cytotoxicity test-negative LURD transplant recipients, transplanted between 1997 and 2014 at the Leiden University Medical Center in The Netherlands. Risk factors for immunization were retrieved from the health records. As methods to screen for preformed donor-specific antibodies (pDSA) have developed through time, we retrospectively screened those with ABMR for pDSA using pooled-antigen bead (PAB) and single-antigen bead (SAB) assays. The cumulative incidence of rejection in the first six months after transplantation was 18% (TCMR 15%; early ABMR 3%). Early ABMR resulted in inferior graft survival and was more common in women who received a kidney from their spouse (10%) than in other women (2%) and men (<1%). The SAB assay retrospectively identified pDSA in seven of nine cases of early ABMR (78%), while the PAB detected pDSA in only three cases (33%). Seeing that early ABMR occurred in 10% of women who received a kidney from their spouse, a SAB assay should be included in the pre-transplant assessment of this group of women, regardless of the result of the PAB assay.


Assuntos
Rejeição de Enxerto/imunologia , Antígenos HLA/genética , Teste de Histocompatibilidade/métodos , Isoanticorpos/sangue , Transplante de Rim , Rim/patologia , Adulto , Idoso , Feminino , Rejeição de Enxerto/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Cônjuges , Doadores de Tecidos
18.
Asian J Transfus Sci ; 14(1): 79-82, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33162714

RESUMO

There are occasions when tests performed before considering a patient for transplant are ambiguous and require further workup. One such condition is the presence of a positive virtual crossmatch (VXm) (anti-human leukocyte antigen [HLA-A]*26: 01 antibody in this case) with a negative complement-dependent cytotoxicity, Luminex, and flow crossmatch. To ascertain the nature of the antibody, the beads used in single-antigen bead assay (SAB) were treated by acid to denature the antigens and retested with the control and test sample. The mean fluorescence intensities (MFIs) from the patient sera with acid-treated beads increased considerably as compared to the regularly untreated SAB indicating additional antigen epitopes become available by the denaturation process. The MFIs of the antibodies from that of the control sera were reduced to half on testing with the acid-treated SAB assay, indicating that HLA antigen HLA-A*26 was susceptible to acid treatment. Therefore, results of VXm should be interpreted with caution.

19.
Hum Immunol ; 80(7): 468-477, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31040048

RESUMO

A major limitation of the single antigen bead (SAB) assay is the so called prozone effect, whereby the detection of high titer complement fixing HLA antibodies is compromised due to complement split product (from C3 and C4 components) deposition and interference with the reporter anti-IgG-PE antibody binding. Strategies to minimize prozone include serum titration or treatment with heat, dithiotreitol (DTT), or ethylenediaminetetraacetic acid (EDTA). While effective, these treatments may compromise HLA antibody binding and detection. Here we describe the Dual Antibody Rapid Test (DART), a modified version of the rapid optimized SAB (ROB) protocol, in which we use an IgG-PE/C3d-PE antibody cocktail to simultaneously detect bead bound IgG and C3d, which allows for detection of HLA antibodies independent of the prozone effect. Twenty prozone positive sera (10 class I and 10 class II), identified by titration, were tested by the ROB protocol, with or without EDTA pre-treatment, using three reporter antibody cocktails: (1) IgG-PE, (2) C3d-PE, or (3) IgG-PE/C3d-PE (DART). Mean fluorescence intensity (MFI) values were then compared. IgG negative (n = 735) vs IgG positive (n = 1185) reactions were identified using a 1000 MFI IgG EDTA cutoff. IgG positive reactions were classified based on ΔMFI (IgG EDTA - IgG) as follows: (1) prozone negative (ΔMFI < 3000; n = 737), (2) slight prozone (ΔMFI 3001-5000; n = 49), (3) moderate prozone (ΔMFI 5001-10,000; n = 93), and (4) marked prozone (ΔMFI > 10,001; n = 306). No C3d deposition was present on IgG negative beads, and the majority of prozone positive specificities (438/448; 98%) fixed complement and were detected with the C3d-PE reporter. Interestingly, C3d-PE MFI was directly proportional to the degree of prozone (mean C3d-PE MFI = 4419.5 ±â€¯1606.3 for slight, 5991.0 ±â€¯2302.7 for moderate, and 12,417.4 ±â€¯2969.9 for marked prozone specificities). Interestingly, EDTA treatment was found to have a negative impact on MFI of up to 15% of prozone negative specificities. Importantly, the DART protocol detected all prozone positive specificities while MFI for prozone negative specificities correlated well with those seen with the IgG-PE reporter alone (R2 = 0.97). In conclusion, the DART protocol accurately detects HLA antibodies independent of the prozone effect. Implementation of DART is an easy way to overcome the prozone effect without compromising HLA antibody detection.


Assuntos
Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Isoanticorpos/imunologia , Anticorpos Anti-Idiotípicos/imunologia , Ativação do Complemento/imunologia , Complemento C3d/imunologia , Ácido Edético/farmacologia , Rejeição de Enxerto/imunologia , Antígenos HLA/sangue , Antígenos de Histocompatibilidade Classe I/sangue , Antígenos de Histocompatibilidade Classe I/imunologia , Antígenos de Histocompatibilidade Classe II/sangue , Antígenos de Histocompatibilidade Classe II/imunologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Transplante de Órgãos , Ficoeritrina/imunologia
20.
Ann Lab Med ; 39(6): 572-576, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31240886

RESUMO

The Luminex-based single antigen bead (SAB) assay is widely used to detect HLA antibody in transplant recipients. However, one limitation of the SAB assay is the prozone effect, which occurs mostly as a result of complement interference. We investigated the efficacy of EDTA treatment for overcoming the prozone effect and predicting C1q binding of HLA antibody. We subjected 27 non-treated (naïve) and EDTA-treated serum samples from highly sensitized patients to IgG-SAB assays, and we confirmed the prozone effect in 53% and 31% of class I and class II antibody tests, respectively, after EDTA treatment. When we conducted additional assays after dithiothreitol treatment and serum dilution, EDTA was the most efficacious in eliminating the prozone effect. Reducing the prozone effect by EDTA treatment strengthened the correlation between IgG mean fluorescence intensity (MFI) and C1q MFI values (ρ=0.825) as compared with the naïve sera (ρ=0.068). Although C1q positivity was dependent on the concentration of HLA antibody in EDTA-treated sera, the correlations varied individually. Overall, our results confirmed the efficacy of EDTA treatment for overcoming the prozone effect. EDTA treatment showed a positive effect on the correlation between IgG MFI and C1q MFI values.


Assuntos
Complemento C1q/metabolismo , Ácido Edético/química , Teste de Histocompatibilidade/métodos , Complemento C1q/química , Ditiotreitol/química , Antígenos HLA/imunologia , Humanos , Imunoglobulina G/química , Ligação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA