Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 406
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Struct Biol ; 216(1): 108057, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38182035

RESUMO

Ctfplotter in the IMOD software package is a flexible program for determination of CTF parameters in tilt series images. It uses a novel approach to find astigmatism by measuring defocus in one-dimensional power spectra rotationally averaged over a series of restricted angular ranges. Comparisons with Ctffind, Gctf, and Warp show that Ctfplotter's estimated astigmatism is generally more reliable than that found by these programs that fit CTF parameters to two-dimensional power spectra, especially at higher tilt angles. In addition to that intrinsic advantage, Ctfplotter can reduce the variability in astigmatism estimates further by summing results over multiple tilt angles (typically 5), while still finding defocus for each individual image. Its fitting strategy also produces better phase estimates. The program now includes features for tuning the sampling of the power spectrum so that it is well-represented for analysis, and for determining an appropriate fitting range that can vary with tilt angle. It can thus be used automatically in a variety of situations, not just for fitting tilt series, and has been integrated into the SerialEM acquisition software for real-time determination of focus and astigmatism.


Assuntos
Algoritmos , Astigmatismo , Extratos Vegetais , Humanos , Astigmatismo/diagnóstico , Software , Processamento de Imagem Assistida por Computador/métodos , Microscopia Crioeletrônica/métodos
2.
Ophthalmology ; 131(3): 383-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38149945

RESUMO

PURPOSE: To review the published literature evaluating the visual and refractive outcomes and rotational stability of eyes implanted with toric monofocal intraocular lenses (IOLs) for the correction of keratometric astigmatism during cataract surgery and to compare those outcomes with outcomes of eyes implanted with nontoric monofocal IOLs and other astigmatism management methods performed during cataract surgery. This assessment was restricted to the toric IOLs available in the United States. METHODS: A literature search of English-language publications in the PubMed database was last conducted in July 2022. The search identified 906 potentially relevant citations, and after review of the abstracts, 63 were selected for full-text review. Twenty-one studies ultimately were determined to be relevant to the assessment criteria and were selected for inclusion. The panel methodologist assigned each a level of evidence rating; 12 studies were rated level I and 9 studies were rated level II. RESULTS: Eyes implanted with toric IOLs showed excellent postoperative uncorrected distance visual acuity (UCDVA), reduction of postoperative refractive astigmatism, and good rotational stability. Uncorrected distance visual acuity was better and postoperative cylinder was lower with toric IOLs, regardless of manufacturer, when compared with nontoric monofocal IOLs. Correcting pre-existing astigmatism with toric IOLs was more effective and predictable than using corneal relaxing incisions (CRIs), especially in the presence of higher magnitudes of astigmatism. CONCLUSIONS: Toric monofocal IOLs are effective in neutralizing pre-existing corneal astigmatism at the time of cataract surgery and result in better UCDVA and significant reductions in postoperative refractive astigmatism compared with nontoric monofocal IOLs. Toric IOLs result in better astigmatic correction than CRIs, particularly at high magnitudes of astigmatism. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Oftalmologia , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Desenho de Prótese , Refração Ocular
3.
Curr Opin Ophthalmol ; 35(4): 278-283, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700941

RESUMO

PURPOSE OF REVIEW: Laser keratorefractive surgery achieves excellent visual outcomes for refractive error correction. With femtosecond laser, small incision lenticule extraction (SMILE) is an increasingly viable alternative to laser-assisted in situ keratomileusis (LASIK). Comparative studies demonstrate similar efficacy and predictability between SMILE and LASIK, making it difficult for clinicians to choose which to use. This review thus compares femtosecond-LASIK (FS-LASK) and SMILE in various scenarios, to assist clinicians in deciding which refractive surgery procedure to recommend. RECENT FINDINGS: SMILE may be superior for highly myopic eyes due to a smaller decrease in functional optical zone. SMILE further induces less spherical aberration and less overall higher order aberrations in mesopic conditions. SMIILE also has less postoperative dry eye, making it suitable those with preexisting dry eye. For low to moderate myopic astigmatism correction, FS-LASIK has less undercorrection compared to SMILE. Lastly, SMILE has not yet received Food and Drug Administration or Conformité Européenne approval for hyperopic correction, rendering FS-LASIK the choice of procedure for hyperopic correction. SUMMARY: Both FS-LASIK and SMILE demonstrate good efficacy and predictability. Understanding specific clinical scenarios where one may be superior to the other will aid clinicians in choosing the most suitable procedure for personalized care.


Assuntos
Substância Própria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/fisiopatologia , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Microcirurgia/métodos
4.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 730-738, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568674

RESUMO

Here, we present a full wave propagation model that quantitatively assesses the effect of astigmatism on visual functions in eyes with diffractive bifocal IOLs. The proposed model with bifocal IOLs evaluated the image quality of each focus at varying degrees of corneal astigmatism with the metrics of modulation transfer function and light-in-the-bucket. The results show that corneal astigmatism alters the distance-near image quality balance. Positive (negative) astigmatism has more detrimental effects on far (near) vision. Additionally, bifocal IOLs are more vulnerable to corneal astigmatism, highlighting the need to consider multifocal toric IOLs with astigmatism greater than 1.0 D. The numerical results closely agreed with previous relevant clinical findings, suggesting the clinical usability of the presented method in predicting the postoperative visual function of patients.


Assuntos
Astigmatismo , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Olho
5.
Appl Opt ; 63(10): 2694-2703, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568554

RESUMO

Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC). The correction was validated by measuring different spherical phantoms and conducting corneal curvature measurements of ex vivo porcine corneas using a commercial spectral-domain OCT system and a clinically approved swept-source OCT as a reference instrument. Thus, the error in radius measurements of spherical phantoms was reduced by >90% and astigmatism by >80% using FDC. In explanted porcine eyes, the error in astigmatism measurements with the Telesto was reduced by 75% for power and 70% for angle. The best fitting sphere radius was determined up to a deviation of 0.4% from the Anterion. This paper describes a correction algorithm for OCT immanent distortion that is applicable to any scanning OCT setup and enables precise corneal curvature measurements. The MATLAB software for the FDC is publicly available on GitHub.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Animais , Suínos , Algoritmos , Software , Córnea/diagnóstico por imagem
6.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454381

RESUMO

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Assuntos
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Acuidade Visual , Pupila , Topografia da Córnea
7.
BMC Ophthalmol ; 24(1): 40, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273262

RESUMO

BACKGROUND: This study aimed to compare the corneal high-order aberrations and surgically induced astigmatism between the clear corneal incision and limbus tunnel incision for posterior chamber implantable collamer lens (ICL/TICL) implantation. METHODS: A total of 127 eyes from 73 myopic patients underwent ICL V4c implantation, with 70 eyes receiving clear corneal incisions and 57 eyes receiving limbus tunnel incisions. The anterior and back corneal surfaces were measured and the Root Mean Square of all activated aberrations (TRMS) was calculated, including higher-order aberration (HOA RMS), spherical aberration Z40, coma coefficients (Coma RMS) Z3-1 Z31, and surgically induced astigmatism (SIA). The measurements were taken preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months. In this study, the corneal higher-order aberration was estimated as the Zernike coefficient calculated up to 5th order. The measurements were taken at a maximum diameter of 6.5 mm using Pentacam. RESULTS: One week after the operation, the corneal back Z31 of the clear corneal incision group was 0.06 ± 0.06, while the limbus tunnel incision group showed a measurement of 0.05 ± 0.06 (p = 0.031). The corneal back Z40 of the clear corneal incision group was -0.02 ± 0.25, compared to -0.04 ± 0.21 in the limbus tunnel incision group (p = 0.01). One month after the operation, the corneal back SIA of the clear corneal incision group was 0.11 ± 0.11, compared to 0.08 ± 0.11of the limbus tunnel incision group (p = 0.013), the corneal total SIA of the clear corneal incision group was 0.33 ± 0.30, compared to 0.15 ± 0.16 in the limbus tunnel incision group (p = 0.004); the clear corneal incision group exhibited higher levels of back astigmatism and total SIA than the limbus tunnel incision in the post-operation one month period. During the 6- month post-operative follow-up period, no significant difference in Z31, Z40, and other HOA RMS data was observed between the two groups. The total SIA of the corneal incision group and the limbus tunnel incision group were 0.24 ± 0.14 and 0.33 ± 0.32, respectively (p = 0.393), showing no significant difference between the two groups 6 months after the operation. CONCLUSION: Our data showed no significant difference in the high-order aberration and SIA between clear corneal incision and limbus tunnel incision up to 6 months after ICL-V4c implantation.


Assuntos
Astigmatismo , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular , Coma/cirurgia , Córnea/cirurgia , Pseudofacia/cirurgia
8.
BMC Ophthalmol ; 24(1): 7, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38178053

RESUMO

BACKGROUND: To investigate the effect of different sizes of pterygium on the front and back corneal topography, refractive changes and aberrations in natural-light and low-light conditions. METHODS: Sixty subjects with unilateral primary nasal pterygium were enrolled in this study. All the patients' uncorrected, best spectacle-corrected visual acuity, corneal topographic aberration data in 3 mm and 7 mm areas were collected. The pterygium size was evaluated by the slit-lamp photography and Sirius Scheimpflug Analyzer. RESULTS: The front topographic astigmatism values, corneal total aberrations, and higher-order aberrations in 3 mm and 7 mm areas were higher in the pterygium group than those in the control group. The pterygium horizontal length and thickness were moderately to strongly correlated with astigmatism and RMS of aberrations, while pterygium vertical length showed no or just mild correlation with the corneal astigmatism and aberrations. Compared to the readings in 3 mm area, the front and back corneal astigmatism and aberrations were larger in 7 mm area. CONCLUSIONS: Pterygium led to visual impairment by inducing astigmatism and aberrations. In low-light condition, the visual function worsened due to increased corneal astigmatism values and aberrations.


Assuntos
Astigmatismo , Doenças da Córnea , Pterígio , Humanos , Pterígio/complicações , Pterígio/diagnóstico , Astigmatismo/diagnóstico , Acuidade Visual , Córnea , Topografia da Córnea
9.
BMC Ophthalmol ; 24(1): 72, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365667

RESUMO

PURPOSE: To compare the rotational stability of a monofocal and a diffractive multifocal toric intraocular lens(IOLs) with identical design and material. METHODS: This prospective study enrolled patients who underwent plate-haptic toric IOL (AT TORBI 709 M and AT LISA 909 M) implantation. Propensity score matching (PSM) was performed to balance baseline factors. Follow-up examinations were conducted at 1 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was used to investigate the changes in IOL rotation over time. A 2-week timeframe was utilized to assess differences in IOL rotation between the two groups. RESULT: After PSM, a total of 126 eyes were selected from each group for further analysis. Postoperatively, the time course of IOL rotation change in the two groups remained consistent, with the greatest rotation occurring between 1 h and 1 day postoperatively. At the 2-week postoperative mark, the monofocal toric IOL exhibited a higher degree of rotation compared to the multifocal toric IOL (5.40 ± 7.77° vs. 3.53 ± 3.54°, P = 0.015). In lens thickness(LT) ≥ 4.5 mm and white-to-white distance(WTW) ≥ 11.6 mm subgroups, the monofocal toric IOL rotated greater than the multifocal toric IOL (P = 0.026 and P = 0.011, respectively). CONCLUSION: The diffractive multifocal toric IOL exhibits superior rotational stability compared to the monofocal toric IOL, especially in subgroups LT ≥ 4.5 mm and WTW ≥ 11.6 mm. Moreover, the time course of IOL rotation change is consistent for both, with the maximum rotation occurring between 1 h and 1 day postoperatively.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Pseudofacia/cirurgia , Acuidade Visual , Pontuação de Propensão , Astigmatismo/cirurgia , Refração Ocular
10.
BMC Ophthalmol ; 24(1): 252, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867207

RESUMO

BACKGROUND: To comparatively analyze the surgically induced astigmatism (SIA) of the anterior, posterior, and total corneas of eyes undertaking implantable collamer lens (ICL) implantation with temporal or superior corneal incisions. METHODS: One hundred and nine eyes of 109 patients who received ICL implantation were recruited: 40 eyes had temporal incisions and 69 eyes had superior incisions. Total corneal refractive power (TCRP); simulated keratometry of the anterior (Sim-KAnt) and posterior (Sim-KPost) corneal curvature; and astigmatism of the anterior (CAAnt), posterior (CAPost), and total (CATCRP) cornea were recorded through a Pentacam preoperatively and 3 months postoperatively. The SIA of the anterior, posterior, and total cornea were also compared between the two groups. RESULTS: There were no significant intergroup differences for TCRP, Sim-KAnt, Sim-KPost, CAAnt, CAPost, or CATCRP, preoperatively. However, values of CAAnt, CAPost, and CATCRP with temporal incision were significantly higher than those parameters with superior incision postoperatively. All of the SIA of the anterior, posterior, and total cornea were significantly lower for temporal incision than those with a superior incision (p < 0.001, p = 0.006 and p = 0.001 respectively). Meanwhile, the superior incisions created against-the-rule (ATR) astigmatism, and temporal incisions always induce with-the-rule (WTR) astigmatism in total cornea. CONCLUSIONS: A superior incision may be suitable for correcting WTR astigmatism, while a temporal incision for correcting ATR astigmatism when using a non-toric ICL. Meanwhile, temporal incision could be a better choice with little preoperative astigmatism or that preoperative astigmatism would be corrected with toric ICLs. TRIAL REGISTRATION: Registration number: ChiCTR2100051739. Prospectively registered: 01 October 2021.


Assuntos
Astigmatismo , Córnea , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/etiologia , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Feminino , Masculino , Adulto , Córnea/cirurgia , Refração Ocular/fisiologia , Adulto Jovem , Miopia/cirurgia , Miopia/fisiopatologia , Pessoa de Meia-Idade , Topografia da Córnea , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos
11.
BMC Ophthalmol ; 24(1): 83, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388340

RESUMO

BACKGROUND: To investigate and compare the vision-related quality of life (QOL) in different types of refractive error (RE). METHODS: This cross-sectional study was performed on 200 subjects, categorized into four groups of 50 each, consisting of subjects with myopia, hyperopia, astigmatism, and emmetropia, the latter being the control group. The mean age of the participants was 23.88 ± 5.87 (range, 15 to 38: 110 females and 90 males). RE was defined as myopia, spherical equivalent (SE) < -0.25 diopters (D), hyperopia, SE > + 0.25 D, astigmatism, cylinder < -0.25 D, and emmetropia (-0.25 ≤ SE(D) ≤ + 0.25, cylinder ≥ -0.25). Groups are subdivided into very low magnitudes of RE (0.50 and 0.75) and significant RE (1.00 ≤). Vision-related QOL was assessed using the Persian version of the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25). The NEI-VFQ was scored as visual function and socioemotional scales using Rasch analysis. RESULTS: Corrected myopia, astigmatism, uncorrected myopia, and hyperopia had a lower vision-related QOL than emmetropes. (P < 0.001). Vision-related QOL in myopic subjects was lower than that in astigmatic participants. Very low myopes, who often do not use correction, had a significantly lower QOL than other groups. CONCLUSION: Individuals with refractive errors experience a lower QOL score than those without. Notably, the adverse impact on QOL score is significantly greater in myopic cases, particularly very low myopia, compared to other refractive errors. Therefore, it is strongly recommended not to neglect managing very low myopia since it may improve participants' QOL.


Assuntos
Astigmatismo , Hiperopia , Miopia , Erros de Refração , Masculino , Feminino , Humanos , Qualidade de Vida , Estudos Transversais
12.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600456

RESUMO

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Refração Ocular , Coma , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/cirurgia , Substância Própria/cirurgia
13.
BMC Ophthalmol ; 24(1): 179, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641836

RESUMO

BACKGROUND: Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction. METHODS: We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences. RESULTS: Binocular examination of 111 children aged 4.86±1.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (p < 0.001) and strong correlation was found between all refractive measurements (Pearson's r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was < 10° in 144 eyes (64.9%). CONCLUSIONS: Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.


Assuntos
Astigmatismo , Erros de Refração , Seleção Visual , Criança , Humanos , Midriáticos , Seleção Visual/métodos , Erros de Refração/diagnóstico , Refração Ocular
14.
BMC Ophthalmol ; 24(1): 116, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481203

RESUMO

BACKGROUND: To investigate the prevalence and risk factors for astigmatism in 7-19-year-old students in Xinjiang, China. METHODS: A school-based, cross-sectional study was conducted on students who underwent refraction examination in Xinjiang, China, between May and December 2019. The prevalence of astigmatism was determined. Astigmatism was defined as cylinder power (C) ≤-0.75 D, undefined astigmatism as ≤-1.50 D, and high astigmatism as C ≤-3.00 D. Astigmatism types were: against-the-rule astigmatism (maximum refraction of the main meridian in 180° ± 30°), with-the-rule astigmatism (maximum refraction of the main meridian at 90°±30°), and oblique astigmatism (all other cases). RESULTS: Of the 71,838 students examined (51.0% boys, 7 - 19 years old), 25,945 (36.1%, 95%CI: 35.52-36.68%) had astigmatism and 1267 (1.8%, 95%CI: 1.07-2.53%) had high astigmatism. The prevalence of astigmatism was greater in Han individuals (39.6%) compared with the Hui (34.0%), Kazakh (34.0%), Kyrgyz (32.1%), and Uyghur (26.4%) populations. Among the 25,945 students with astigmatism, 19,947 had with-the-rule astigmatism (76.9%), 3405 had against-the-rule astigmatism (13.1%), and 2593 had oblique astigmatism (10.0%). Multivariable logistic regression analysis showed that ethnicity (Han individuals more susceptible), male gender, age, and refractive errors (myopia and hyperopia) were independently associated with astigmatism, high astigmatism, and with-the-rule astigmatism (all P < 0.05). CONCLUSIONS: The prevalence of astigmatism among children and adolescents in Xinjiang was 36.1%, including 1.8% of high astigmatism. In this population, astigmatism was mainly of the with-the-rule astigmatism type (76.9%). Han ethnicity, male gender, and myopia or hyperopia were independently associated with a high risk of astigmatism.


Assuntos
Astigmatismo , Hiperopia , Miopia , Erros de Refração , Criança , Adolescente , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Astigmatismo/epidemiologia , Astigmatismo/diagnóstico , Estudos Transversais , Prevalência , Erros de Refração/epidemiologia , Miopia/epidemiologia , Estudantes , Fatores de Risco , China/epidemiologia
15.
BMC Ophthalmol ; 24(1): 174, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627647

RESUMO

PURPOSE: To evaluate the long-term clinical outcomes of femtosecond thin-flap LASIK (femto-LASIK) for correction of refractive error after penetrating keratoplasty in keratoconus-affected eyes. SETTING: a private ophthalmology clinic. DESIGN: Prospective interventional case series. METHODS: This prospective interventional case series enrolled 22 eyes of 22 patients who underwent femto-LASIK for the management of post-penetrating keratoplasty ametropia. The refractive error, uncorrected (UDVA), and corrected (CDVA) distance visual acuities and vector analysis were reported in short-term and long-term period after surgery. RESULTS: The mean age was 32.7 ± 7.5 years (range, 23 to 47 years) at the surgery time. The average time between PK and femto-LASIK was 42.5 ± 31.7 months. The average follow-up duration after femto-LASIK was 81.2 ± 18.6 months. The mean preoperative UDVA significantly improved from 0.47 ± 0.15 logMAR to 0.35 ± 0.14 logMAR at 12 months (P = 0.048) and 0.4 ± 0.17 at final follow-up exam (P = 0.007). CDVA was 0.22 ± 0.1 at baseline which improved to 0.18 ± 0.15 and 0.15 ± 0.1 logMAR at 12 and 81 months, respectively. (Ps = 0.027, 0.014). The mean cylinder before surgery was - 5.04 ± 1.4D which significantly decreased to -1.5 ± 0.8 D at 12 months postoperatively. (P < 0.001). There was a significant increase in refractive astigmatism from 12 months to 81 months postoperatively (-3.1 ± 2.0, P = 0.002). At the final visit, the efficacy index was 0.83, and the safety index was 1.16. CONCLUSIONS: Despite the short-term outcome indicated that femo-LASIK was effective for correction of post-keratoplasty ametropia during short-term period, a notable regression in its effect was observed in the long-term follow-up. Therefore, the predictability of this technique might decrease in the long-term.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Erros de Refração , Humanos , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Estudos Prospectivos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
16.
BMC Ophthalmol ; 24(1): 362, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39174922

RESUMO

PURPOSE: To investigate the three-year visual, refractive outcomes and adverse events of the Eyecryl toric phakic IOL (pIOL) for moderate-to-high myopic astigmatism. METHODS: This retrospective study included eligible patients who underwent refractive surgery in one or both eyes with Eyecryl toric pIOL for myopic astigmatism. The efficacy, safety, predictability, rotational stability, vector analysis, and adverse events were evaluated in patients with spherical refraction from - 4.50 to -17.00 diopters (D) and cylindrical refraction from - 0.75 to -5.50 D. RESULTS: Fifty-two eyes of 28 patients were included in the study. The mean efficacy and safety index were 1.12 ± 0.35 and 1.38 ± 0.42, respectively. The mean manifest refraction spherical equivalent was - 10.06 ± 2.69 D and - 0.64 ± 0.61 D preoperatively and postoperatively at 36 months, respectively. The mean manifest astigmatism was - 2.06 ± 1.16 D and - 0.44 ± 0.48 D preoperatively and 36 months postoperative, respectively. During the final examination, 70% of the eyes showed an increase in CDVA of one or more lines compared to their preoperative state. There was a cumulative endothelial cell loss of 3.1% at 36 months postoperatively. One eye developed visually significant anterior subcapsular opacity, whereas another eye experienced pIOL opacification. CONCLUSION: The Eyecryl toric pIOL demonstrated satisfactory visual acuity and refractive outcomes, as assessed by efficacy, safety and stability over a three-year period.


Assuntos
Astigmatismo , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Acuidade Visual/fisiologia , Adulto , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pessoa de Meia-Idade , Desenho de Prótese , Miopia/cirurgia , Miopia/fisiopatologia , Seguimentos , Adulto Jovem , Resultado do Tratamento
17.
BMC Ophthalmol ; 24(1): 45, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287289

RESUMO

BACKGROUND: To evaluate the possible topographic and surgical risk factors for high postoperative residual astigmatism in patients who undergo small-incision lenticule extraction (SMILE) surgery and have different myopia degrees. METHODS: A retrospective cohort study was conducted, and patients who underwent SMILE surgery were enrolled. A total of 80 and 150 eyes from 40 to 75 individuals, respectively, were selected as the low myopia and high myopia groups. The demographic data, visual acuity, refraction, topographic parameters and surgical settings were recorded. Multiple linear regression with interaction tests were performed to survey the risk factors for high postoperative residual astigmatism in each group. RESULTS: Five (6.25%) and 9 (6.00%) eyes presented with high postoperative residual astigmatism in the low myopia and high myopia groups, respectively, but these differences were not significant (P = 0.569). A steep corneal curvature was correlated with a greater risk of high postoperative residual astigmatism in the low myopia group (P = 0.015), while a higher degree of cycloplegic cylinder power, steeper corneal curvature, greater topographic cylinder power, smaller optic zone and longer incision length were associated with a high rate of postoperative residual astigmatism in the high myopia group (all P < 0.05). In addition, the interaction effects of cycloplegic and topographic cylinder power and longer incision length on the incidence of high postoperative residual astigmatism development were more evident in the high myopia group than in the low myopia group (all P < 0.05). CONCLUSIONS: A steep corneal curvature correlates with a high risk of high postoperative residual astigmatism after SMILE surgery, and a higher degree of cycloplegic and topographic cylinder and longer incision are associated with high postoperative residual astigmatism in individuals with high myopia.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Midriáticos , Topografia da Córnea , Microcirurgia , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
18.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
19.
BMC Ophthalmol ; 24(1): 285, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009964

RESUMO

AIM: This study aimed to differentiate moderate to high myopic astigmatism from forme fruste keratoconus using Pentacam parameters and develop a predictive model for early keratoconus detection. METHODS: We retrospectively analysed 196 eyes from 105 patients and compared Pentacam variables between myopic astigmatism (156 eyes) and forme fruste keratoconus (40 eyes) groups. Receiver operating characteristic curve analysis was used to determine the optimal cut-off values, and a logistic regression model was used to refine the diagnostic accuracy. RESULTS: Statistically significant differences were observed in most Pentacam variables between the groups (p < 0.05). Parameters such as the Index of Surface Variance (ISV), Keratoconus Index (KI), Belin/Ambrosio Deviation Display (BAD_D) and Back Elevation of the Thinnest Corneal Locale (B.Ele.Th) demonstrated promising discriminatory abilities, with BAD_D exhibiting the highest Area under the Curve. The logistic regression model achieved high sensitivity (92.5%), specificity (96.8%), accuracy (95.9%), and positive predictive value (88.1%). CONCLUSION: The simultaneous evaluation of BAD_D, ISV, B.Ele.Th, and KI aids in identifying forme fruste keratoconus cases. Optimal cut-off points demonstrate acceptable sensitivity and specificity, emphasizing their clinical utility pending further refinement and validation across diverse demographics.


Assuntos
Topografia da Córnea , Ceratocone , Fotografação , Curva ROC , Humanos , Ceratocone/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Adulto , Gana , Topografia da Córnea/métodos , Fotografação/métodos , Adulto Jovem , Adolescente , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Miopia/diagnóstico , Astigmatismo/diagnóstico , Acuidade Visual
20.
Optom Vis Sci ; 101(7): 451-463, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39110980

RESUMO

SIGNIFICANCE: Angular Indication Measurement (AIM) is an adaptive, self-administered, and generalizable orientation-judgment method designed to interrogate visual functions. We introduce AIM Visual Acuity (VA) and show its features and outcome measures. Angular Indication Measurement VA's ability to detect defocus was comparable with that of an Early Treatment of Diabetic Retinopathy Study (ETDRS) letter chart and showed greater sensitivity to astigmatic blur. PURPOSE: This proof-of-concept study introduces Angular Indication Measurement and applies it to VA. METHODS: First, we compared the ability of AIM-VA and ETDRS to detect defocus and astigmatic blur in 22 normally sighted adults. Spherical and cylindrical lenses in the dominant eye induced blur. Second, we compared repeatability over two tests of AIM-VA and ETDRS. RESULTS: A repeated-measure analysis of variance showed a main effect for defocus blur and test. For the astigmatism experiment, an interaction between blur and orientation was found. Pairwise comparisons showed that AIM was more sensitive to astigmatic-induced VA loss than ETDRS. Bland-Altman plots showed small bias and no systematic learning effect for either test type and improved repeatability with more than two adaptive steps for AIM-VA. CONCLUSIONS: Angular Indication Measurement VA's ability to detect defocus was comparable with that of an ETDRS letter chart and showed greater sensitivity to induced astigmatic blur, and AIM-VA's repeatability is comparable with ETDRS when using two or more adaptive steps. Angular Indication Measurement's self-administered orientation judgment approach is generalizable to interrogate other visual functions, e.g., contrast, color, motion, and stereovision.


Assuntos
Testes Visuais , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Masculino , Adulto , Feminino , Testes Visuais/métodos , Adulto Jovem , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA