Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 17.799
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Hum Evol ; 189: 103512, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38461589

RESUMO

Neanderthal anterior teeth are very large and have a distinctive morphology characterized by robust 'shovel-shaped' crowns. These features are frequently seen as adaptive responses in dissipating heavy mechanical loads resulting from masticatory and non-masticatory activities. Although the long-standing debate surrounding this hypothesis has played a central role in paleoanthropology, is still unclear if Neanderthal anterior teeth can resist high mechanical loads or not. A novel way to answer this question is to use a multidisciplinary approach that considers together tooth architecture, dental wear and jaw movements. The aim of this study is to functionally reposition the teeth of Le Moustier 1 (a Neanderthal adolescent) and Qafzeh 9 (an early Homo sapiens adolescent) derived from wear facet mapping, occlusal fingerprint analysis and physical dental restoration methods. The restored dental arches are then used to perform finite element analysis on the left central maxillary incisor during edge-to-edge occlusion. The results show stress distribution differences between Le Moustier 1 and Qafzeh 9, with the former displaying higher tensile stress in enamel around the lingual fossa but lower concentration of stress in the lingual aspect of the root surface. These results seem to suggest that the presence of labial convexity, lingual tubercle and of a large root surface in Le Moustier 1 incisor helps in dissipating mechanical stress. The absence of these dental features in Qafzeh 9 is compensated by the presence of a thicker enamel, which helps in reducing the stress in the tooth crown.


Assuntos
Homem de Neandertal , Humanos , Adolescente , Animais , Incisivo , Simulação por Computador , Análise de Elementos Finitos , Coroas , Estresse Mecânico
2.
Clin Oral Implants Res ; 35(4): 377-385, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38170349

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of sterilization on the retention forces of lithium disilicate (LD) and polymer-infiltrated ceramic network (PICN) crowns bonded to titanium base (Ti-base) abutments. MATERIALS AND METHODS: Forty LD and 40 PICN crowns were milled and then bonded to 80 Ti-bases with two resin composite cements: Multilink Hybrid Abutment (mh) and Panavia V5 (pv) for a total of 8 groups (n = 10). Half of the specimens (test) underwent an autoclaving protocol (pressure 1.1 bar, 121°C, 20.5 min) and the other half not (control). Restorations were screw-retained to implants, and retention forces (N) were measured with a pull-off testing machine. The surfaces of the Ti-bases and the crowns were inspected for the analysis of the integrity of the marginal bonding interface and failure mode. Student's t-test, chi-square test, and univariate linear regression model were performed to analyze the data (α = 0.05). RESULTS: The mean pull-off retention forces ranged from 487.7 ± 73.4 N to 742.2 ± 150.3 N. Sterilized groups showed statistically significant overall higher maximum retention forces (p < .05), except for one combination (LD + mh). Sterilization led to an increased presence of marginal gaps and deformities compared to no-sterilization (p < .001), while no statistically significant relationship was found between failure mode and sterilization (p > .05). CONCLUSIONS: Sterilization may have a beneficial effect on the retention forces of LD and PICN crowns bonded to titanium base abutments, although it may negatively influence the integrity of the marginal bonding interface.


Assuntos
Polímeros , Titânio , Porcelana Dentária , Coroas , Teste de Materiais , Zircônio , Cerâmica , Análise do Estresse Dentário , Dente Suporte , Desenho Assistido por Computador
3.
Clin Oral Implants Res ; 35(7): 685-693, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38594815

RESUMO

OBJECTIVES: Clinical data on all-ceramic screw-retained implant crowns (SICs) luted on titanium base abutments (TBAs) over more than 3 years are sparse. This study aimed to evaluate the clinical performance and potential risk factors for these restorations. MATERIALS AND METHODS: Analysis took place based on the medical patient-records of three dental offices. Implant survival and prosthetic complications over time were evaluated. The study included SICs in premolar and molar regions made from monolithic lithium disilicate ceramic (M_LiDi) or veneered zirconia (V_ZiO) luted on a TBA documented over an observation time of at least 3 years. Survival and complication rates were calculated and compared by a log-rank test. Cox-Regressions were used to check potential predictors for the survival (p < .05). RESULTS: Six hundred and one crowns out of 371 patients met the inclusion criteria and follow-up period was between 3.0 and 12.9 (mean: 6.4 (SD: 2.1)) years. Over time, six implants had to be removed and 16 restorations had to be refabricated. The estimated survival rates over 10 years were 93.5% for M_LiDi and 95.9% for V_ZiO and did not differ significantly among each other (p = .80). However, V_ZiO showed significantly higher complication rates (p = .003). Material selection, sex, age, and implant diameter did not affect the survival of investigated SICs but crown height influences significantly the survival rate (hazard ratio, HR = 1.26 (95%CI: 1.08, 1.49); p = .043). CONCLUSIONS: Screw-retained SICs luted on TBAs that were fabricated from monolithic lithium disilicate ceramic or veneered zirconia showed reliable and similar survival rates. Increasing crown heights reduced survival over the years.


Assuntos
Cerâmica , Coroas , Falha de Restauração Dentária , Humanos , Estudos Retrospectivos , Fatores de Risco , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Prótese Dentária Fixada por Implante , Idoso , Zircônio , Porcelana Dentária , Planejamento de Prótese Dentária
4.
Clin Oral Implants Res ; 35(1): 89-100, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37941089

RESUMO

OBJECTIVES: To compare the clinical performance of single crowns in the posterior maxilla supported by either 11-mm long implants combined with maxillary sinus floor augmentation (MSFA) surgery or by 6-mm long implants during a 10-year follow-up period. MATERIALS AND METHODS: Subjects were randomly allocated to receive one 11-mm long implant in combination MFSA or to receive one 6-mm long implant without any grafting. Twenty-one implants in 20 patients were placed in the 6-mm group and 20 implants in 18 patients were placed in the 11-mm group. Both groups were followed by clinical and radiographic examinations up to 10 years. Patients' satisfaction was also scored before treatment. RESULTS: Two patients died and eight patients moved during the follow-up. Two patients lost an implant in the 6-mm group and one implant was lost in the 11-mm group (implant survival 89.5% and 90.9%, respectively). From loading to 10 years' follow-up, mean ± SE marginal bone loss in the 6-mm group and 11-mm group was 0.18 ± 0.10 mm and 0.26 ± 0.12 mm, respectively, without a significant difference between the groups at 10 years (p = .650). In both groups, indices scores for plaque, calculus, gingiva and bleeding were low as well as mean pocket probing depth. Patients' satisfaction at 10 years was high in both groups; mean overall satisfaction in the 6-mm group and 11-mm group was 9.6 ± 0.6 and 9.2 ± 0.8, respectively (p = .168). CONCLUSIONS: Placement of 6-mm implants or 11-mm implants combined MFSA are equally successful during a 10-year follow-up period when applied for supporting a single restoration.


Assuntos
Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Humanos , Implantação Dentária Endóssea , Maxila/diagnóstico por imagem , Maxila/cirurgia , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Coroas , Resultado do Tratamento , Seguimentos
5.
Clin Oral Implants Res ; 35(6): 630-640, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38567929

RESUMO

OBJECTIVES: This RCT aimed to compare zirconia and titanium dental implants in the maxillary premolar region. The comparison was based on marginal bone level (MBL) changes, clinical parameters, aesthetic outcomes, and patient related outcome measures (PROMs) 1 year after prosthetic loading. MATERIALS AND METHODS: Fifty patients were randomly assigned to receive either a zirconia (ZrO2, n = 25) implant or a titanium (Ti, n = 25) bone-level implant. Implants were provided with a lithium disilicate crown 3 months after placement. Follow-up was at 1 month and after 1 year. The primary outcome pertained to changes in MBL. Reported secondary outcomes consisted of implant survival, peri-implant tissue health, aesthetics, and PROMs. RESULTS: Mean MBL change after 1 year was 0.01 mm (SD = 0.45; min = 0.72, max = 0.86) for ZrO2 and -0.09 mm (SD = 0.34; min = 0.53, max = -1.06) for Ti (p = .439). Scores for the other clinical outcome parameters and PROMs were generally favorable, with no significant differences. However, significant differences were found for the aesthetic outcomes regarding two criteria: (a) level of facial mucosa (p = .022), in favor of Ti, and (b) root convexity/soft tissue color and texture (p = .005) in favor of ZrO2. CONCLUSION AND CLINICAL IMPLICATIONS: The ZrO2 and Ti implant types used in this study, replacing a single missing maxillary premolar, show a comparable outcome in terms of MBL change after 1 year. Clinical and aesthetic parameters, as well as PROMs, are favorable and similar between both implant types after 1 year of prosthetic loading. These short-term study results suggest that both are suitable for clinical use.


Assuntos
Implantes Dentários para Um Único Dente , Maxila , Titânio , Zircônio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Maxila/cirurgia , Adulto , Estética Dentária , Idoso , Resultado do Tratamento , Coroas , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Dente Pré-Molar
6.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444156

RESUMO

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Assuntos
Cimentos de Ionômeros de Vidro , Boca , Zircônio , Membrana Celular , Coroas
7.
Med Sci Monit ; 30: e943237, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38343120

RESUMO

BACKGROUND This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10-degree and 20-degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin-based) on the adhesive failure stress of 3-mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. MATERIAL AND METHODS A total of 160 working models (3D-printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20-degree typodont master models and two 20-degree 3D-printed master models (groove and box), simulating a 3 mm high all-ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin-based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55°C) and pull-off tests on a universal testing machine. Statistical analysis was performed using one-way ANOVA and post hoc Tukey test. RESULTS Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20-degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P≤0.05. CONCLUSIONS 3D-printed PC, resin-based cement, 10-degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20-degree taper, and vertical groove.


Assuntos
Adesivos , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Coroas , Impressão Tridimensional , Cimentos de Ionômeros de Vidro , Cimentos Dentários
8.
Clin Oral Investig ; 28(1): 94, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38221600

RESUMO

OBJECTIVES: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.


Assuntos
Cerâmica , Falha de Restauração Dentária , Zircônio , Prótese Parcial Fixa , Porcelana Dentária , Teste de Materiais , Análise do Estresse Dentário , Coroas
9.
Clin Oral Investig ; 28(4): 220, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492074

RESUMO

OBJECTIVES: This in vitro study aims to compare the fracture resistance of three CAD/CAM materials used in endocrown restoration of interproximal defects in maxillary premolars. MATERIALS AND METHODS: 45 maxillary premolars extracted as part of orthodontic treatment were included. Following standardized root canal treatment, all teeth were prepared into Mesial-Occlusal (MO) cavity types. The samples were then randomly divided into three groups: LD [repaired with lithium disilicate glass ceramics (IPS e.max CAD)], VE [treated with polymer-infiltrated ceramics (Vita Enamic)], and LU [repaired with resin-based nanoceramics (Lava Ultimate)]. Axial static loading was applied using a universal testing machine at 1 mm/min until fracture, and fracture resistance and failure modes were recorded. RESULTS: Regarding Fracture Resistance Values (FRVs), the LD group exhibited significantly higher values than the other two groups, VE (P = 0.028) and LU (P = 0.005), which showed no significant difference (P = 0.778). On the other hand, regarding failure modes, the LD group had a higher prevalence of irreparable fractures compared to the other two groups, VE (P < 0.001) and LU (P < 0.001), which showed no significant difference. CONCLUSIONS: Although lithium disilicate glass ceramics exhibited higher FRVs, they had a lower repair probability. In contrast, polymer-infiltrated ceramics and resin-based nanoceramics contributed to tooth structure preservation. CLINICAL RELEVANCE: For maxillary premolars with interproximal defects following root canal treatment, resin ceramic composites are recommended for restoration to enhance abutment teeth protection.


Assuntos
Cerâmica , Coroas , Dente Pré-Molar , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química , Resinas Compostas/química , Polímeros , Desenho Assistido por Computador , Análise do Estresse Dentário , Falha de Restauração Dentária
10.
Clin Oral Investig ; 28(5): 298, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702521

RESUMO

OBJECTIVES: To assess the long-term clinical performance of ceramic in-/onlays (CIOs) and cast gold partial crowns (CGPCs) in posterior teeth in terms of success, survival, complications (biological, technical) and quality. MATERIAL AND METHODS: In a retrospective study, a total of 325 patients were recorded after up to 24.8 years (mean 13.9 ± 3.8 years) having (pre-)molars restored with CIO (Empress I, Ivoclar Vivadent, n = 161) and CGPC (Degunorm, DeguDent, n = 164) by supervised undergraduate students. A total of 296 restorations were assessed clinically and radiologically in healthy and endodontically treated teeth using modified United States Public Health Service (USPHS) criteria. Cumulative success and survival rates of the restorations were calculated using Kaplan-Meier estimates. Biological and technical complications were recorded. Status of oral health comprising caries risk and localized periodontitis were assessed. RESULTS: The cumulative success rates of CIOs were 92.1% and of CGPCs 84.2% after mean service times of 14.5 years. The annual failure rates of total service times were 0.5% in teeth restored with CIO (n = 155) and 0.7% in teeth restored with CGPC (n = 163). The cumulative survival rates of CIOs were 93.9% after a mean service time of 15.2 years and decreased to 91.7% after 23.5 years. The cumulative survival rates of CGPCs were 92.6% after a mean service time of 14.9 years and 91.8% after 23.5 years. Complications in CIOs (n = 149) were ceramic fracture (6.7%), secondary caries (4.7%), endodontic complication (2.7%) and tooth fracture (1.3%) compared to CGPCs (n = 147) with endodontic complication (8.8%), secondary caries (4.8%) and decementation (2.0%). Endodontically treated teeth restored with CIO or CGPC revealed significantly less often success compared with corresponding vital teeth (p = .02). CIOs and CGPCs revealed clinically and radiographically good and excellent qualities with 71.8% (107/149) and 68% (100/147) without any significant differences regarding type of restoration. CONCLUSIONS: Both CIOs and CGPCs achieved high survival rates up to 24.8 years when performed by supervised undergraduate students. The longevity of the restorations may benefit from the intraoral repair of accessible defects and, in case of pulp infection or necrosis, an adequate endodontic management. CLINICAL RELEVANCE: CIOs and CGPCs made by supervised undergraduate students are proper restoration types in posterior teeth in the long-term. An adequate preparation design, meticulous care in the inserting technique and constant biofilm removal due to proper oral hygiene combined with professional maintenance care are substantial. The clinical long-term performance was mostly limited by ceramic fractures in CIOs and endodontic complications in CGPCs.


Assuntos
Coroas , Falha de Restauração Dentária , Humanos , Estudos Retrospectivos , Feminino , Masculino , Adulto , Restaurações Intracoronárias , Cerâmica , Ligas de Ouro , Cárie Dentária/terapia , Porcelana Dentária/química , Pessoa de Meia-Idade , Planejamento de Prótese Dentária , Dente não Vital , Resultado do Tratamento
11.
Clin Oral Investig ; 28(7): 371, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38869697

RESUMO

OBJECTIVES: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. METHODS: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 µm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5-55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). RESULTS: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. CONCLUSIONS: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. CLINICAL RELEVANCE: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.


Assuntos
Desenho Assistido por Computador , Coroas , Colagem Dentária , Análise do Estresse Dentário , Teste de Materiais , Resistência ao Cisalhamento , Propriedades de Superfície , Colagem Dentária/métodos , Cerâmica/química , Silanos/química , Materiais Dentários/química , Corrosão Dentária/métodos , Porcelana Dentária/química , Técnicas In Vitro , Humanos
12.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
13.
Am J Dent ; 37(2): 85-90, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704851

RESUMO

PURPOSE: To evaluate clinical performances of two lithium disilicate systems (Initial LiSi press vs Initial LiSi Block, GC Co.) using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 4 years of clinical service. METHODS: Partial adhesive crowns on natural abutment posterior teeth were made on 60 subjects who were randomly divided into two groups: Group 1: Initial LiSi press and Group 2: Initial LiSi Block. Fabrication of partial crowns was made with full analog and digital procedure in Groups 1 and 2 respectively. The restorations were followed-up for 1 and 4 years, and the modified USPHS evaluation was performed at baseline and each recall together with periodontal evaluation. Contingency tables to assess for significant differences of success over time in each group and time-dependent Cox regression to test for differences between the two groups were used and the level of significance was set at P< 0.05. RESULTS: Regarding modified USPHS scores, all evaluated parameters showed Alpha or Bravo and no Charlie was recorded. No statistically significant difference emerged between the two groups in any of the assessed variables (P> 0.05). No statistically significant difference between scores recorded at the baseline and each recall. All modified USPHS scores were compatible with the outcome of clinical success and no one restoration was replaced or repaired, and the survival rate was 100% after 4 years of clinical service. No difference was found between traditional and digital procedure to fabricate the crowns. The two lithium disilicate materials showed similar results after 4 years of clinical service. CLINICAL SIGNIFICANCE: The crowns made with the two tested lithium disilicate materials with analog and digital procedures showed 100% survival after 4 years of clinical service with no statistically significant difference using the modified USPHS scores.


Assuntos
Coroas , Porcelana Dentária , Humanos , Porcelana Dentária/química , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Seguimentos
14.
Am J Dent ; 37(3): 164-168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899998

RESUMO

PURPOSE: To investigate the effect of different abutments and crowns on the color of implant-supported restorations. METHODS: Zirconia and lithium disilicate (e.max) disks with A2 shade were fabricated to represent two crowns. The implant abutments were untreated titanium, opaqued titanium, anodized titanium, A2 shade zirconia and white zirconia. 4.0 mm-thickness zirconia and e.max specimens were used as references respectively. The crowns were placed on tested abutments with a drop of clear glycerin between them and the color was measured using a digital spectrophotometer. CIELab values were recorded to evaluate color differences (ΔE) between tested specimens and the references. RESULTS: Titanium abutments presented higher color differences than zirconia. The ΔE values with untreated titanium were higher than those with opaqued titanium. No differences were found between untreated titanium and anodized titanium for zirconia crowns. The ΔE values of zirconia crowns showed no significant differences between shade A2 zirconia and white zirconia abutments; e.max crowns showed a significant difference. The zirconia crown ΔE values were lower than those of e.max for all titanium and A2 zirconia abutments. Lithium disilicate crowns and zirconia abutments may be more suitable for implant-supported restorations. Opaqued titanium abutment may improve color in esthetic regions when a ceramic abutment cannot be used. CLINICAL SIGNIFICANCE: Lithium disilicate crowns and zirconia abutments may be an effective method to achieve excellent color matching in esthetic regions with implant-supported restorations.


Assuntos
Cor , Coroas , Dente Suporte , Porcelana Dentária , Prótese Dentária Fixada por Implante , Titânio , Zircônio , Zircônio/química , Titânio/química , Porcelana Dentária/química , Materiais Dentários/química , Espectrofotometria , Projeto do Implante Dentário-Pivô , Teste de Materiais , Humanos , Pigmentação em Prótese
15.
Odontology ; 112(1): 242-249, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37273122

RESUMO

The present study aims to determine the optimum sectioning depth for the extraction of low-level horizontally impacted mandibular third molar (LHIM3M) using mechanical and finite element analysis. One hundred and fifty extracted mandibular third molars were randomly divided into three groups: 1, 2 or 3 mm of tooth tissue was retained at the bottom of the crown. The breaking force of teeth was tested in a universal strength testing machine. The fracture surface was observed and the type of tooth breakage was recorded. According to the three groups, corresponding 3D finite element models were created. The breaking force obtained in the mechanical study was, respectively, applied and the stress and strain of the teeth and surrounding tissues were analysed. Breaking force decreased as sectioning depth increased. The 2 mm group produced the lowest rate of incomplete breakage (10%). In the 2 mm model, the stresses were evenly distributed in the tooth tissue at the bottom of the fissure, and the maximal stress was located in the tissue close to the root segment. The maximum values of stresses in the bone and of strains in the periodontal ligament of the second molar and bone were lower in the 1 mm model than in other models. Their distribution was similar in the three models. A sectioning depth of 1 mm group saves labour during the extraction of LHIM3M, compared to 2 and 3 mm; 2 mm might be the appropriate sectioning depth in terms of breakage shapes.


Assuntos
Dente Serotino , Dente Impactado , Humanos , Análise de Elementos Finitos , Dente Molar , Dente Impactado/cirurgia , Coroas , Extração Dentária , Mandíbula
16.
Odontology ; 112(1): 272-278, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37354297

RESUMO

This study aims to evaluate the effect of Teethmate, Bifluoride 12, and Copal Varnish on the treatment of dentin hypersensitivity and the pulpal blood flow using laser Doppler flowmetry (LDF) after full crown preparations. Eighteen patients with 42 teeth with dentine hypersensitivity after full crown preparations were randomly treated with Teethmate, Bifluoride 12, and Copal Varnish. Dentine hypersensitivity was measured using a visual analog scale (VAS) and Schiff air index (SAI). LDF was used to assess the pulpal blood flow and results were recorded in perfusion units (PU). All measurements were performed at baseline, 5 min, 7 days, and 1 month after the application of desensitizers. Data were statistically analyzed by Wilcoxon and two-way ANOVA tests (p < 0.05). There was no significant difference between the tested desensitizers regarding VAS and PU values. VAS values decreased significantly at 7 days and 1 month after the application of desensitizers compared to baseline in all groups. The decrease in PU values significantly differed only in the Copal Varnish group at 5 min and 7 days after the application of the desensitizer (p < 0.05). A statistically significant difference was found between different times regarding SAI scores in all groups (p < 0.05). Teethmate, Bifluoride 12, and Copal Varnish showed similar effectiveness on dentine hypersensitivity and pulpal blood flow. Long-term clinical trials with larger sample sizes and histological studies are needed to evaluate their impacts on pulpal status.


Assuntos
Sensibilidade da Dentina , Humanos , Sensibilidade da Dentina/tratamento farmacológico , Fluxometria por Laser-Doppler/métodos , Sulindaco/uso terapêutico , Polpa Dentária , Coroas
17.
Acta Odontol Scand ; 83: 362-370, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864178

RESUMO

INTRODUCTION: The objectives of this study were to evaluate how laypersons and orthodontists evaluate and rank aesthetic parameters of an implant-supported crown (ISC) on the canine position (ISC-C) and lateral position (ISC-L). METHODS: A digital survey of 11 cases, 5 ISC-C, 5 ISC-L and 1 control case without ISC, was distributed to 207 laypersons and 296 orthodontists. All cases included one extraoral photograph and three intraoral photographs. The respondents were asked to identify the ISC and to evaluate the aesthetic parameters regarding colour of the implant (CI), shape of the implant (SI) and gingival colour around ISC (GCI). Differences within and between the groups were tested using Chi-2-test and Independent-Samples t-test. RESULTS: All invited laypersons and 184 orthodontists (62% response rate) answered the survey. Orthodontists (89%) more correctly identified the ISC, regardless of its position, than laypersons (50%) (p < 0.001). Both laypersons (54%) and orthodontists (23%) rated higher proportions of acceptance of CI, SI and GCI in favour for the ISC-L than ISC-C (laypersons: 40%, orthodontists: 10%) (p < 0.001). Assessing each parameter separately, orthodontists rated higher for ISC-L, compared to the ISC-C (p < 0.001). In general, laypersons and orthodontist ranked tooth colour (mean, standard deviation [SD]:8.0,1.5 and 9.0, 1.0) and tooth shape (mean, SD: 8.0, 1.7 and 8.8, 1.2) as aesthetically higher than the gingival colour (mean, SD: 7.2, 2.2 and 8.0, 1.7) (p > 0.001).  Conclusion: Laypersons and orthodontists consider the ISC-L as aesthetically more preferable, compared to the ISC-C.


Assuntos
Estética Dentária , Ortodontistas , Humanos , Ortodontistas/psicologia , Feminino , Adulto , Masculino , Maxila , Dente Canino/anatomia & histologia , Inquéritos e Questionários , Coroas , Pessoa de Meia-Idade
18.
J Esthet Restor Dent ; 36(2): 295-302, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37497796

RESUMO

OBJECTIVE: Teeth prepared for mesial-occlusal-distal (MOD) restorations have a significant risk of cusp fracture. Crowns and onlays can provide cusp coverage to reinforce posterior teeth at risk. Onlays are often more conservative of tooth structure which may be an advantage for teeth with large MOD preparations. It remains uncertain how onlays and crowns compare for posterior teeth with MOD tooth structure loss. The purpose of this systematic review was to compare the resistance to fracture, success rate, survival rate, and failure rate of teeth with MOD preparations restored with onlays or crowns. MATERIALS AND METHODS: An electronic search queried Medline (PubMed), Embase (Ovid), Scopus, the Cochrane Library, and grey literature (OpenGrey) from database inception through April 29, 2023. RESULTS: After eliminating duplicates and irrelevant records, 32 manuscripts were assessed. Only three publications met the criteria for inclusion. Most exclusions were due to poor reporting of restorative design and the amount of tooth structure remaining, or due to combining various restorative designs. Due to the limited sample size and high heterogeneity, no meta-analysis was conducted. One study observed a better outcome for onlays and two observed no difference. All three studies reported the mode of failure for crowns as more catastrophic whereas teeth with onlays could be salvaged. CONCLUSIONS: Onlays may be an advantageous alternative to crowns for teeth with MOD preparations, but the level of evidence is insufficient to draw meaningful conclusions. CLINICAL SIGNIFICANCE: Current evidence is insufficient to determine whether onlays or crowns are providing a different outcome when used to restore posterior teeth with MOD tooth structure loss. However, the fracture of teeth with MOD tooth structure loss restored with onlays appears to be less catastrophic than when restored with crowns.


Assuntos
Coroas , Restaurações Intracoronárias , Dente , Humanos
19.
J Esthet Restor Dent ; 36(2): 270-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37615345

RESUMO

OBJECTIVE: Immediate implants and immediate alveolar sealing have been a widely utilized treatment with high predictability and biological advantages. The improvement in technology has made it possible to simplify clinical processes. The aim of the present report was to describe the complete digital workflow of the Biologically oriented preparation technique for immediate posterior implant, immediate provisionalization and fabrication of definitive implant crowns. CLINICAL CONSIDERATIONS: The surgical process and prosthetic management to preserve the gingival contours of the extracted natural tooth during immediate implant placement and provisionalization are described. Additionally, during the same clinical intervention, the definitive intraoral digital implant scans for capturing the implant position, peri-implant tissue contours, adjacent and antagonist dentition, and profile emergence of the interim implant crown are captured for the fabrication of the definitive crown. CONCLUSIONS: Based on the technique described, the immediate implant placement and provisionalization in the posterior area provides biological and clinical advantages, reducing the number of abutment-implant disconnections and the number of clinical appointments, as well as increases patient comfort. CLINICAL SIGNIFICANCE: The present article describes a technique for an immediate implant placement and provisionalization in the posterior region for maintaining the gingival architecture of the extracted tooth. During the same appointment, the implant position, peri-implant tissue contours, and adjacent and antagonist dentition, and profile emergence of the interim implant crown are captured by using an intraoral scanner and used for the fabrication of the definitive crown. This technique aims to reduce the number of abutment-implant disconnections and clinical appointments.


Assuntos
Implantes Dentários para Um Único Dente , Humanos , Fluxo de Trabalho , Coroas , Coroa do Dente , Implantação Dentária Endóssea/métodos
20.
J Esthet Restor Dent ; 36(1): 164-173, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38173277

RESUMO

AIM: The aim of this randomized, prospective, and clinical multicenter study was to compare the overall clinical performance of two restorative options over a 5-year period: individualized CAD/CAM abutments veneered with a hand-layered ceramic, and prefabricated zirconium dioxide abutments veneered with press ceramic and inserted into a single edentulous gap in the anterior maxilla. MATERIALS AND METHODS: Forty subjects were recruited from two universities: 20 from the University of XX and 20 from the University of XY. Each subject received an implant to restore a single edentulous gap in the maxillary anterior region (14-24 FDI). 20 patients were randomized into each Group. Group A received a one-piece single crown produced from a prefabricated zirconia abutment with pressed ceramic and Group B received an individualized CAD/CAM zirconia abutment with a hand-layered technique. After 5 years, the aesthetic and radiographic parameters were assessed. RESULTS: Group A had four dropouts and one failure, resulting in a 95% survival rate and 95% success rate. Group B had two dropouts and two failures which resulted in a 90% survival rate and 90% success rate. No crestal bone level changes were observed, with a mean DIB of 0.06 mm in Group A and 0.09 mm in Group B. No statistically significant differences were present at baseline, 6 months, 1 year, 3 years, or 5 years for DIB values between time points and groups. Pink aesthetic score/white aesthetic score, Peri-Implant and Crown Index, and Implant Crown Aesthetic Index values were stable over time at all five points for both groups. CONCLUSION: Both implant-supported restorative options represent a valuable treatment option for the restoration of implant crowns in the anterior maxilla. CLINICAL SIGNIFICANCE: In general, the use of ceramic abutments in the anterior zone represents a valuable treatment procedure with both standardized and CAD/CAM individualized abutments and following the recommendations from the respective manufacturer(s).


Assuntos
Cerâmica , Zircônio , Humanos , Estudos Prospectivos , Coroas , Desenho Assistido por Computador , Dente Suporte , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA