RESUMO
In this study, we developed physically adsorbed multi-layer coatings using poly-l-lysine or poly(diallyldimethylammonium chloride) and gold nanoparticles, which were functionalized with bovine serum albumin for the chiral separation in electrochromatography. The approach involves sequentially depositing positively charged polymers and negatively charged citrate-stabilized gold nanoparticles. By repeating this modification cycle, we created two- and four-layer coatings, which were sequentially functionalized with albumin forming three- and five-layer coatings that were finally applied for the separation of enantiomers of dl-tryptophan. The formed coatings exhibit stability across a pH range of 2-10 and feature a dense, uniform surface, as confirmed by scanning electron microscope images. The number of layers impacted nanoparticle deposition density, with five-layer coatings being denser than three-layer ones. Five-layer coatings enable baseline separation of dl-tryptophan enantiomers, whereas three-layer coatings require the presence of albumin in the background electrolyte for separation. Therefore, increasing the number of layers and gold nanoparticles density enhances albumin active center concentration on capillary walls, improving the separation of dl-tryptophan enantiomers. The five-layer coatings can be easily fabricated and possess good repeatability of analytes migration time.
Assuntos
Eletrocromatografia Capilar , Nanopartículas Metálicas , Soroalbumina Bovina/química , Eletrocromatografia Capilar/métodos , Ouro/química , Triptofano , Polímeros/química , Nanopartículas Metálicas/química , EstereoisomerismoRESUMO
A new enantioselective open-tubular capillary electrochromatography (OT-CEC) was developed employing ß-cyclodextrin covalent organic frameworks (ß-CD COFs) conjugated gold-poly glycidyl methacrylate nanoparticles (Au-PGMA NPs) as a stationary phase. The resulting coating layer on the inner wall of the fabricated capillary column was characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), energy dispersive spectroscopy (EDS), and electroosmotic flow (EOF) experiments. The performance of the fabricated capillary column was evaluated by CEC using enantiomers of seven model analytes, including two proton pump inhibitors (PPIs, omeprazole and tenatoprazole), three amino acids (AAs, tyrosine, phenylalanine, and tryptophan), and two fluoroquinolones (FQs, gatifloxacin and sparfloxacin). The influences of coating time, buffer concentration, buffer pH, and applied voltage on enantioseparation were investigated to obtain satisfactory enantioselectivity. In the optimum conditions, the enantiomers of seven analytes were fully resolved within 10 min with high resolutions of 3.03 to 5.25. The inter- to intra-day and column-to-column repeatabilities of the fabricated capillary column were lower than 4.26% RSD. Furthermore, molecular docking studies were performed based on the chiral fabricated column and as ligand isomers of analytes using Auto Dock Tools. The binding energies and interactions acquired from docking results of analytes supported the experimental data.
Assuntos
Eletrocromatografia Capilar , Ouro , beta-Ciclodextrinas , Eletrocromatografia Capilar/métodos , Ouro/química , beta-Ciclodextrinas/química , Estereoisomerismo , Ácidos Polimetacrílicos/química , Aminoácidos/química , Aminoácidos/análise , Fluoroquinolonas/química , Fluoroquinolonas/análise , Nanopartículas Metálicas/química , Estruturas Metalorgânicas/química , Simulação de Acoplamento MolecularRESUMO
The nano-LC technique is increasingly used for both fast studies on enantiomeric analysis and test beds of novel stationary phases due to the small volumes involved and the short conditioning and analysis times. In this study, the enantioseparation of 10 drugs from different families was carried out by nano-LC, utilizing silica with immobilized amylose tris(3-chloro-5-methylphenylcarbamate) column. The effect on chiral separation caused by the addition of different salts to the mobile phase was evaluated. To simultaneously separate as many enantiomers as possible, the effect of buffer concentration in the mobile phase was studied, and, to increase the sensitivity, a liquid-liquid microextraction based on the use of isoamyl acetate as sustainable extraction solvent was applied to pre-concentrate four chiral drugs from tap and environmental waters, achieving satisfactory recoveries (>70%).
Assuntos
Eletrocromatografia Capilar , Microextração em Fase Líquida , Humanos , Eletrocromatografia Capilar/métodos , Fenilcarbamatos/química , Cromatografia Líquida/métodos , Estereoisomerismo , Amilose/química , Água , Cromatografia Líquida de Alta Pressão/métodosRESUMO
An open tubular capillary electrochromatography column covalently bonded with polystyrene sulfonate was prepared via in situ polymerization using functionalized Azo-initiator 4,4'-Azobis(4-cyanopentanoyl chloride). Scanning electron, fluorescence, and atomic force microscopy techniques showed the formation of a relatively rough layer of polymer. In addition, -CN and C = O stretching vibrations from infrared spectroscopy proved the successful immobilization of the azo-initiator through covalent bonding and X-ray photoelectron spectroscopy confirmed the elemental composition of the formed polymer layer. The prepared column was found to be appropriate for small and medium-sized molecules separation. Compared to bare fused silica capillary column higher selectivity and resolution were obtained for the separation of alkaloids, sulfonamides, and peptides as a result of the electrostatic and pi-pi stacking interactions between the small organic molecules and the coated column without compromising the electroosmotic flow mobility. Separation efficiency was also increased compared to the bare capillary for the separation of alkaloids (about 1.5 times). Moreover, intraday, inter-day, intra-batch, and inter-batch relative standard deviation values of retention time and peak area of peptides were within 2% and 10%, respectively, indicating good repeatability of the column preparation procedure. The developed method for the covalent bonding of polymers through a functionalized azo-initiator could represent a promising stable method for the preparation of an open tubular column.
Assuntos
Alcaloides , Eletrocromatografia Capilar , Cloretos , Sulfonamidas , Polimerização , Polímeros/química , Peptídeos , Eletrocromatografia Capilar/métodosRESUMO
A novel chiral porous column was fabricated by lipase immobilized MIL-100(Fe) biocomposites as chiral stationary phase through covalent coupling and applied to capillary electrochromatographic enantioseparation. MOF-based lipase biocomposites not only enhance stereoselective activities but also improve the stability and applicability of the enzyme. The functionalized porous columns were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, and powder X-ray diffraction. The performance of the porous column was evaluated by enantioseparating amino acid enantiomers, affording high resolution over 2.0. Besides, the enantio-resolutions of phenylephrine, phenylsuccinic acid, chloroquine, and zopiclone were also greater than 2.0. The relative standard deviations of run-to-run, intra-, and inter-day repeatability were within 4.0% in terms of resolution and retention time, exhibiting excellent stability of the column. Conceivably, the results show that MOF-based lipase composites as chiral stationary phase offer a highly efficient means for enantioseparation in capillary electrochromatography, attributing to the enhanced enantioselective activities of lipase by highly ordered frameworks.
Assuntos
Eletrocromatografia Capilar , Eletrocromatografia Capilar/métodos , Lipase , Microscopia Eletrônica de Varredura , Cloroquina , EstereoisomerismoRESUMO
Metal-organic frameworks (MOFs) have exhibited tremendous potential in the area of separation science. However, most of the developed MOF-based stationary phases contained only microporous structures and suffer from limited separation performance. Herein, homomesoporous MOFs with excellent mass transfer capability and strong thermodynamic interactions are first explored as the novel stationary phase for high-performance capillary electrochromatographic separations. As a proof of concept, noninterpenetrated mesoMOF-1 with uniform mesopore sizes (22.5 × 26.1 Å) and good stability was facilely grown on the inner surface of capillaries and applied as a homomesoporous MOF coating-based stationary phase for high-efficiency electrochromatographic separation. Seven types of analytes with different molecular dimensions were all baseline separated on a mesoMOF-1 coated column with high theoretical plate numbers and excellent repeatability, exhibiting significantly improved separation selectivity and column efficiency in comparison to a microporous HKUST-1 coated column. The maximum column efficiencies of the mesoMOF-1 coated column for substituted benzenes and halobenzenes reached up to 1.4 × 105 plates/m, and its mass loadability was also much higher than that of the HKUST-1 coated column. In addition, based on the analysis of adsorption kinetics and chromatographic retention behaviors, the interaction and retention mechanisms of different molecular-weight analytes on mesoMOF-1 coated stationary phases were systematically explored and disclosed in detail. These results indicate that the homomesoporous MOF-based stationary phase can effectively balance the kinetic diffusion (mass transfer capability) and thermodynamic interactions (the strength of adsorption interaction), having great potential for high-performance chromatographic separation.
Assuntos
Eletrocromatografia Capilar , Estruturas Metalorgânicas , Eletrocromatografia Capilar/métodos , Benzeno , TermodinâmicaRESUMO
By developing a novel chiral column, we integrate open tubular capillary electrochromatography into sheathless mass spectrometry (MS) for efficient analysis of underivatized amino acid enantiomers. The chiral column is easily fabricated by modifying the inner surface of a capillary with a three-dimensional porous layer (PL, thickness â¼ 90 nm, pore size â¼ 30 nm) and gold nanoparticles and by introducing a chiral selector, thiol ß-cyclodextrin (SH-ß-CD), onto the modified surface via Au-S bonds. This approach greatly enhances the specific surface area and thus the ratio of the stationary phase to mobile phase and interaction between the stationary phase and analytes. The proposed PLOT@Au@CD column is coupled to the sheathless CE-ESI-MS system for chiral analysis of amino acid enantiomers. No derivatization of amino acids is required for chiral analysis, and baseline separation of a total of 15 pairs of amino acid enantiomers is achieved within 17 min with high column efficiencies of 5.60 × 104 to 1.82 × 106 N/m, high resolutions of 1.51-10.0, and low limits of detection between 0.02 and 0.09 µg/mL. The separation efficiency and MS intensity are only slightly decreased over 60 runs or after usage for 15 days, showing excellent repeatability and stability of the PLOT@Au@CD column. The proposed method is successfully applied to the determination of amino acid enantiomers in vinegar samples with satisfactory accuracy. Our study provides a new approach for developing a chiral stationary phase in the chromatographic separation technique, which can be easily coupled to sensitive MS detection, thus it would be of value for various applications in the fields of chiral analysis.
Assuntos
Eletrocromatografia Capilar , Nanopartículas Metálicas , Aminoácidos , Eletrocromatografia Capilar/métodos , Ouro/química , Espectrometria de Massas , Nanopartículas Metálicas/química , Porosidade , EstereoisomerismoRESUMO
In this work, a new open-tubular capillary electrochromatography (OT-CEC) column was prepared using ß-cyclodextrin covalent organic framework (ß-CD COF) as a stationary phase. Polydopamine was used to assist fabrication of ß-CD COF on an inner wall of a fused-silica capillary. The coating layer on the capillary was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Electroosmotic flow (EOF) was also studied to evaluate the variation of the inner wall of immobilized columns. Furthermore, the chiral separation effectiveness of the fabricated capillary column was evaluated by CEC using enantiomers of several related proton pump inhibitors as model analytes, including omeprazole, lansoprazole, pantoprazole and tenatoprazole. The effects of bonding time and concentration of ß-CD COF, the type, concentration and pH of buffer, applied voltage were investigated to obtain satisfactory enantioselectivity. In the optimum conditions, the enantiomers of four analytes were resolved within 15 min with resolutions of 1.63-2.62. The relative standard deviation values for migration times and resolutions of the analytes representing intraday and interday were less than 6.75% and 4.24%, respectively. The results reveal that ß-CD COF has great potential as chiral-stationary phases for enantioseparation in CEC.
Assuntos
Eletrocromatografia Capilar , beta-Ciclodextrinas , 2-Piridinilmetilsulfinilbenzimidazóis/análise , Eletrocromatografia Capilar/métodos , Indóis , Polímeros , Estereoisomerismo , beta-Ciclodextrinas/químicaRESUMO
The histidine-modified zeolitic imidazolate framework [His-ZIF-67] was prepared with the histidine, 2-methylimidazole, and Co2+ under ambient temperature. His-ZIF-67 was bonded via a glycidyl methacrylate copolymer to the internal surface of capillary and then functionalized with the NH2 -ß-cyclodextrin (NH2 -ß-CD). The materials were characterized by field emission scanning electron microscopy, high-resolution transmission electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, N2 adsorption-desorption isotherm, X-ray diffraction, and X-ray photoelectron spectroscopy. In comparison with the NH2 -ß-CD@capillary, the NH2 -ß-CD@His-ZIF-67@capillary-coated column shows significantly enhanced resolution for chiral molecules. The NH2 -ß-CD@His-ZIF-67@capillary column achieved the baseline separation of amlodipine and metoprolol (the resolution of amlodipine: 1.70; metoprolol: 1.50) and the partial separation of atenolol and propranolol (the resolution of atenolol: 1.03; propranolol: 0.60). These were attributed to the histidine modification and the features of ZIF-67, including an excellent surface area and the abundant porosity. The pH and proportion of organic modifier in the buffer were crucial for enantioseparation performance and were evaluated in detail. The fabricated NH2 -ß-CD@His-ZIF-67@capillary-coated column showed good stability and repeatability (relative standard deviation <6.3%). The molecular modeling with AutoDock and grand canonical ensemble was carried out to evaluate the interactions between chiral stationary phase and racemic drugs.
Assuntos
Eletrocromatografia Capilar , Ciclodextrinas , Zeolitas , Anlodipino/análise , Atenolol , Eletrocromatografia Capilar/métodos , Histidina , Metoprolol , Propranolol , EstereoisomerismoRESUMO
We developed a novel, convenient and low-cost one-pot strategy for preparing a zeolitic imidazolate framework-8 (ZIF-8)-silica hybrid monolithic column by adding ZIF-8 directly to a polymer solution of the silica matrix. The simulated stationary phase and monolithic column prepared under optimal conditions were characterized using X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectroscopy, thermogravimetric analysis nitrogen physisorption and zeta potential. The results obtained confirmed the successful introduction of ZIF-8 into the silica monolithic column, and the prepared monolithic column exhibited good permeability and physicochemical stability. A capillary electrochromatography method was developed based on a ZIF-8-silica hybrid monolithic column through which 15 mixed amino acids, 4 neutral compounds, 4 nipagin esters and 2 chlorinated fungicides were separated in 14, 5, 7 and 6 min, respectively, under optimal conditions. The relative standard deviations retention times and column efficiencies in run-to-run, day-to-day and column-to-column varied in the ranges of 1.90%-2.21%, 2.13%-2.51% and 3.08%-6.65%, respectively, which demonstrated that ZIF-8-silica hybrid monolithic column exhibited satisfactory reproducibility and stability. The incorporation of ZIF-8 into a silica monolithic column is a promising method for preparing novel monolithic columns composed of a metal-organic framework.
Assuntos
Eletrocromatografia Capilar , Zeolitas , Aminoácidos , Eletrocromatografia Capilar/métodos , Imidazóis/química , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Dióxido de Silício/química , EsqueletoRESUMO
A novel chiral stationary phase (CSP) of Zr-based metal-organic framework, l-Cys-PCN-224, was prepared by one-pot method and applied for the enantioseparation by capillary electrochromatography. The CSP was characterized by X-ray diffraction, thermogravimetric analysis, X-ray photoelectron spectroscopy, Fourier-transform infrared spectra, nitrogen adsorption/desorption, circular dichroism spectrum, zeta-potential, and so on. The results revealed that the CSP had good crystallinity, high specific surface area (2580 m2 /g), and good thermal stability. Meanwhile, the cross-section of l-Cys-PCN-224-bonded open-tubular (OT) column was observed by a scanning electron microscope, which proved the successful bonding of l-Cys-PCN-224 particles to the inner wall. Relative standard deviations of the column efficiencies were 3.87%-9.14%, and not obviously changed after 200 runs, which indicated that l-Cys-PCN-224-bonded OT column had the better stability and reproducibility. Excellent chiral separation performance was verified with nine kinds of natural amino acids including acidic, neutral, and basic as the analytes. All amino acids studied achieved good separation with the resolution of 1.38-13.9 and selector factor of 1.11-3.71. These results demonstrated that the CSP had an excellent potential in the chiral separation field.
Assuntos
Eletrocromatografia Capilar , Estruturas Metalorgânicas , Aminoácidos , Eletrocromatografia Capilar/métodos , Estruturas Metalorgânicas/química , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , EstereoisomerismoRESUMO
A monolithic-based mixed-mode stationary phase was prepared for capillary electrochromatography via the fast photoinitiated polymerization of 2-methacryloyloxyethyl phosphorylcholine and polyhedral oligomeric silsesquioxane methacrylate (POSS-MA) monomers in the presence of crosslinker pentaerythritol triacrylate (PETA). Several copolymerization parameters, including the composition of monomers or porogens, ratio of crosslinkers to monomers, and polymerization time, were systematically optimized to tune the permeability and efficiency of monolithic columns. The morphologies and structures of the as-prepared monoliths were characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy, thermogravimetry and nitrogen adsorption/desorption analysis, indicating a typical POSS skeleton morphology with numerous mesopores on the monolith. Owing to the incorporation of zwitterionic functional groups and rigid POSS skeleton on the hybrid monolith, the resulting stationary phase exhibited both hydrophilic and electrostatic interactions, as well as good mechanical stability. Pressurized CEC separation of various kinds of polar compounds such as amides, nucleobases, nucleosides and benzoic acids, and polypeptide antibiotics was achieved by mixed-mode retention mechanisms including hydrophilic interaction chromatography (HILIC) and weak cation exchange chromatography (WCX) with a high column efficiency up to 93 500 plates per m (thiourea).
Assuntos
Eletrocromatografia Capilar , Eletrocromatografia Capilar/métodos , Interações Hidrofóbicas e Hidrofílicas , Metacrilatos/química , Nucleosídeos , Fosforilcolina , PolimerizaçãoRESUMO
This article summarizes our cooperation with the research group of Prof. Yoshio Okamoto at Nagoya University during the period of time between 1992 and 2005. Although the text deals entirely with enantioseparations in high-performance liquid chromatography, capillary electrophoresis, and capillary electrochromatography, this is not a detailed review in any of these areas. The text highlights selected aspects of these techniques, which have been the subject of our joint research and in part their reflection in follow-up research by our and other research groups. Together with more systematically studied topics, aspects such as ultrafast separation of enantiomers, uncommonly high separation factor of enantiomers and other related issues are also addressed.
Assuntos
Eletrocromatografia Capilar , Eletrocromatografia Capilar/métodos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , EstereoisomerismoRESUMO
Metal organic frameworks (MOFs) have drawn broad attention as a novel stationary phase due to their highly porous structure, modifiable pores, large specific surface areas, and satisfactory stability. In this paper, histidine-zeolitic imidazolate framework-8 (His-ZIF-8) synthesized at room temperature was physically coated to the internal surface of the capillary column and the carboxymethyl-ß-cyclodextrin (CM-ß-CD) as the chiral selector was chemically bonded to the His-ZIF-8@capillary column. The prepared CM-ß-CD@His-ZIF-8@capillary column was used for the enantioseparation of amlodipine, propranolol, and atenolol in capillary electrochromatography. In contrast to the CM-ß-CD@capillary column without His-ZIF-8, the CM-ß-CD@His-ZIF-8@capillary column reveals significantly improved enantiodiscrimination performance for amlodipine (Rs : 0 â 2.29), propranolol (Rs : 0 â 1.69), and atenolol (Rs : 0 â 0.79). His-ZIF-8 concentration, buffer pH, buffer concentration, and the proportion of organic modifier were evaluated in detail with enantiomerically separating chiral molecules. The repeatability of intraday, day-to-day, and column-to-column have been discussed; the result was preferable, and the relative standard deviation (RSD) of separation parameters was <6.7%.
Assuntos
Eletrocromatografia Capilar , Zeolitas , Anlodipino/análise , Atenolol , Eletrocromatografia Capilar/métodos , Histidina , Propranolol , Estereoisomerismo , beta-CiclodextrinasRESUMO
Covalent organic frameworks (COFs) have been recognized as promising solid phases in capillary electrochromatography (CEC). Imine-based COF-coated open-tubular CEC column (COF TpBD-coated OT column) was prepared and characterized by X-ray diffraction (XRD), Fourier-transform infrared (FT-IR) spectra, thermogravimetric analysis (TGA), nitrogen adsorption/desorption (Brunauer-Emmett-Teller [BET]), and scanning electron microscopy (SEM). The results showed that the column efficiency was up to 26,776 plate/m, and the thickness of stationary phase was about 6.00 µm for the column prepared under the optimal conditions. Enantioseparation of 15 kinds of the single chiral compounds (histidine, arginine, lysine, leucine, threonine, methionine, valine, aspartic acid and glutamic acid, fipronil, diclofop, imazamox, quizalofop-p, imazethapyr, and acephate) and 3 kinds of mixed amino acids racemaces (valine, methionine, and glutamic acid) were performed with three methods: capillary electrochromatography with COF TpBD-coated OT column (Method 1), CEC with COF TpBD-coated OT column as the separation channels, and capillary electrophoresis (CE) with HP-ß-CD as the chiral mobile phase additive (Method 2) and CE with HP-ß-CD as the chiral mobile phase additive (Method 3). Separation efficiency and chiral selectivity of Method 2 was best among the three methods. Under the optimal separation conditions of Method 2, all the enantiomers reached the baseline separation regardless of the single chiral compounds or the mixed amino acids. Relative standard deviation (RSDs) of the mean column efficiency for reproducibility and stability was in the range of 0.46-1.49%. This combination of CEC and CE has great potential for use in chiral separation.
Assuntos
Eletrocromatografia Capilar , Ciclodextrinas , Estruturas Metalorgânicas , Eletrocromatografia Capilar/métodos , Estruturas Metalorgânicas/química , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , EstereoisomerismoRESUMO
Metal organic frameworks have received great attention as the chiral stationary phase for racemic drug separation because of their fascinating structures and properties. However, the most homochiral metal organic frameworks were constructed by rare and precious chiral organic ligands. In this work, an achiral metal organic framework, together with a natural chiral selector carboxymethyl ß-cyclodextrin built a synergistic separation system in the open tubular capillary electrochromatography. The novel coated columns were developed by inducing metal organic framework nanoparticles to grow on the imidazolyl functional capillary inner wall. The baseline separations of hydroxychloroquine, ofloxacin, and atenolol were achieved in the synergistic separation system. The effects of the concentration of chiral selector, pH, voltage, and the concentration of organic additives were studied. Compared with chiral selector auxiliary bare capillary, the resolutions of three drugs were remarkably improved. The relative standard deviations for the retention time of intraday (n = 6), interday (n = 6), and column-to-column were less than 2.1, 2.6, and 5.2%, respectively. These results demonstrate that affordable synergistic separation systems are prospective for racemic drug enantioseparation in capillary electrochromatography.
Assuntos
Eletrocromatografia Capilar , Estruturas Metalorgânicas , Nanopartículas , Eletrocromatografia Capilar/métodos , Estruturas Metalorgânicas/química , Nanopartículas/química , Estudos Prospectivos , EstereoisomerismoRESUMO
A fluorinated covalent organic framework composed of 2,3,5,6-tetrafluoroterephthaldehyde (TFA) and 1,3,5-tri(4-aminophenyl)benzene (TAPB) is proposed for electrochromatographic separation. TFA-TAPB is for the first time regarded as the stationary phase of capillary electrochromatography. The TFA-TAPB-coated capillary columns exhibited satisfactory separation (resolution values > 1.5) and good reproducibility towards fluoroquinolones. The intraday relative standard deviations (RSDs) of retention time and peak areas were 0.54-0.68% and 1.69-2.82%, respectively. The interday RSDs of retention time and peak areas were less than 1.79% and 2.30%, respectively. The column-to-column RSDs of retention time and peak areas were 0.22-0.73% and 0.74-1.86%, respectively. And, the inter-batch RSDs of retention time and peak areas were less than 0.39% and 1.67%, respectively. Moreover, the possible separation mechanism was discussed, and it was found that the π-π stacking effect, hydrophobic interaction, hydrogen bonding, and fluorous interactions were the main factors. Overall, these results demonstrated that TFA-TAPB has high prospect for CEC separation.
Assuntos
Eletrocromatografia Capilar , Estruturas Metalorgânicas , Eletrocromatografia Capilar/métodos , Fluoroquinolonas , Interações Hidrofóbicas e Hidrofílicas , Estruturas Metalorgânicas/química , Reprodutibilidade dos TestesRESUMO
Fatty acids determination is of paramount importance for quality control and suitable labeling of edible oils, required by regulatory agencies in several countries, and fast methods for this determination are worldly desired. This review article aimed to explore the available analytical methods for vegetable and marine oils analyses employing CE, which can be a straightforward and faster alternative than GC methods for fatty acid determination, considering some purposes. CE usually offers the possibility of a rapid analysis with a simple preparation of the sample, without requiring specific columns, which are inherent advantages of the technique. Instrumental conditions and the key points about fatty acids determination employing the technique are highlighted, and the main challenges and perspectives are also approached. Potential use of CE for edible oil analyses has been demonstrated for research and routine, which can be of interest for industries, regulatory agencies, and edible oil researchers. Therefore, we have explored the analytical approaches described in the last decades, intending to spread the interest of CE methods for fatty acid monitoring, label accuracy assessment, and food authenticity evaluation of edible oils.
Assuntos
Eletrocromatografia Capilar/métodos , Ácidos Graxos , Óleos de Peixe/química , Óleos de Plantas/química , Ácidos Graxos/análise , Ácidos Graxos/química , Limite de Detecção , Reprodutibilidade dos TestesRESUMO
Mixed-mode chromatography open tubular column has been developed for peptide separation in electrochromatography. A column with 92 cm effective length and 50 µm internal diameter is fabricated internally with a copolymer sheet of restricted thickness. Catalyst facilitated binding of the coupling agent 3,5-bis (trifluoromethyl) phenyl isocyanate has been carried out at the interior surface of the column. The initiator sodium diethyldithiocarbamate was bound to the coupling agent. A small amount of N-[2-(acryloylamino) phenyl] acrylamide was used along with methacrylic acid and styrene in the monomer mixture to induce a little polar character in the stationary phase fabricated inside the column. Twenty-three peptides have been separated from a chemically digested protein mixture present in cytochrome C in capillary electrochromatography, in addition to the separation of six commercial peptides. We achieved an average plate count of over 1.5 million/m with the column of current study both for the digested protein components and commercial peptides using 70/30% v/v (acetonitrile/20 mM ammonium formate) at pH 6.5. In addition, the column resulted in baseline separation of all the peptides with very good resolution, enhanced peak capacity, and better retention time span.
Assuntos
Eletrocromatografia Capilar/métodos , Proteômica/métodos , Peptídeos/análiseRESUMO
Prior to the identification of proteins for proteomics analysis in human cells, separation of fluorogenic derivatized proteins with a fluorogenic reagent, 7-chloro-N-[2-(dimethylamino)ethyl]-2,1,3-benzoxadiazole-4-sulfonamide, has typically been performed by using a conventional reversed-phase HPLC column. However, the number of proteins in human cells (HepaRG) that are separated by this conventional approach is limited to approximately 500. In this study, a nanoflow liquid chromatography system with an evaluated phenyl-bonded monolithic silica capillary column (0.1 mm i.d., 700 mm length) was used to increase the number of separated fluorogenic derivatized proteins. This system was used to separate derivatized human cell proteins (K562) and yeast (Saccharomyces cerevisiae) proteins as model cell proteomes. More than 1,300 protein peaks were separated/detected from both cell proteomes. We present a straightforward comparison of multiple separation profiles using a novel chromatogram display approach, termed the "spiderweb" chromatogram. In addition, to validate that the detected peaks are derived from proteins, a mass spectrometer was connected to the capillary column and deconvolution of the obtained mass spectra was performed. Furthermore, different molecular weight distribution profiles of the expressed proteins were observed between the two cell proteomes.