Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.175
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Surg Res ; 299: 322-328, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788469

RESUMO

INTRODUCTION: Surgical stabilization of rib fractures (SSRF) using standard rib plating systems has become a norm in developed countries. However, the procedure has not garnered much interest in low-middle-income countries, primarily because of the cost. METHODS: This was a single-center pilot randomized trial. Patients with severe rib fractures were randomized into two groups: SSRF and nonoperative management. SSRF arm patients underwent surgical fixation in addition to the tenets of nonoperative management. Low-cost materials like stainless steel wires and braided polyester sutures were used for fracture fixation. The primary outcome was to assess the duration of hospital stay. RESULTS: Twenty-two patients were randomized, 11 in each arm. Per-protocol analysis showed that the SSRF arm had significantly reduced duration of hospital stay (22.6 ± 19.1 d versus 7.9 ± 5.7 d, P value 0.031), serial pain scores at 48 h and 5 d (median score 5, IQR (3-6) versus median score 7, IQR (6.5-8), P value 0.004 at 48 h and median score 2 IQR (2-3) versus median score 7 IQR (4.5-7) P value 0.0005 at 5 d), significantly reduced need for injectable opioids (9.9 ± 3.8 mg versus 4.4 ± 3.4 mg, P value 0.003) and significantly more ventilator-free days (19.9 ± 8.7 d versus 26.4 ± 3.2 d, P value 0.04). There were no statistically significant differences in the total duration of ICU stay (median number of days 2, IQR 1-4.5 versus median number of days 7, IQR 1-14, P value 0.958), need for tracheostomy (36.4% versus 0%, P value 0.155), and pulmonary and pleural complications. CONCLUSIONS: SSRF with low-cost materials may provide benefits similar to standard rib plating systems and can be used safely in resource-poor settings.


Assuntos
Fixação Interna de Fraturas , Tempo de Internação , Fraturas das Costelas , Humanos , Projetos Piloto , Fraturas das Costelas/cirurgia , Fraturas das Costelas/economia , Fraturas das Costelas/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/economia , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/economia , Fixação Interna de Fraturas/métodos , Poliésteres/economia , Suturas/economia , Fios Ortopédicos/economia , Resultado do Tratamento , Idoso , Placas Ósseas/economia , Aço Inoxidável/economia
2.
Biomed Eng Online ; 23(1): 66, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997736

RESUMO

BACKGROUND: Management of inferior ramus of the pubis-ischium ramus remains controversial, and related research is sparse. The main intention of this study is to describe the biomechanical and clinical outcomes of pubis-ischium ramus fractures in Tile B pelvic injuries and to identify the feasibility and necessity of fixation of the inferior ramus of the pubis-ischium ramus. METHODS: This study comprised two parts: a biomechanical test and a retrospective clinical study. For the biomechanical tests, Tile B-type pelvic injuries were modeled in six cadaver specimens by performing pubis-ischium osteotomies and disruption of the anterior and interosseous sacroiliac ligaments. The superior and/or inferior rami of the pubis-ischium ramus were repaired with reconstruction plates and separated into three groups (A, B, and C). Specimens were placed in the standing position and were loaded axially with two-leg support for three cycles at 500 N. The displacements of sacroiliac joints at osteotomy were measured with Vernier calipers and compared using statistical software. To investigate the clinical outcomes of this technique, 26 patients were retrospectively analyzed and divided into a superior ramus fixation group (Group D) and a combined superior and inferior ramus of the pubis-ischium ramus fixation group (Group E). The main outcome measures were time of operation, blood loss, postoperative radiographic reduction grading, and functional outcomes. RESULTS: In the vertical loading test, Group E showed better pelvic ring stability than Group D (P < 0.05). However, the shift of the sacroiliac joints was almost identical among the three groups. In our clinical case series, all fractures in Group E achieved bony union. Group E demonstrated earlier weight-bearing functional exercise (2.54 ± 1.45 vs 4.77 ± 2.09; P = 0.004), earlier bony union (13.23 ± 2.89 vs 16.55 ± 3.11; P = 0.013), and better functional outcomes (89.77 ± 7.27 vs 82.38 ± 8.81; P = 0.028) than Group D. The incidence of sexual dysfunction was significantly lower in Group E than that in Group D (2/13 vs 7/13; P = 0.039). Bone nonunion occurred in two patients in Group D, and two patients in Group E had heterotopic ossification. None of the patients exhibited wound complications, infections, implant failures, or bone-implant interface failures. CONCLUSIONS: Fixation of the inferior ramus of a pubis-ischium ramus fracture based on conventional fixation of the anterior pelvic ring is mechanically superior in cadaveric Tile B pelvic injury and shows rapid recovery, good functional outcomes, and low incidence of complications.


Assuntos
Placas Ósseas , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Masculino , Feminino , Adulto , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Ossos Pélvicos/diagnóstico por imagem , Pessoa de Meia-Idade , Fenômenos Mecânicos , Cadáver , Fraturas Ósseas/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas/instrumentação
3.
J Oral Maxillofac Surg ; 82(7): 792-799, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38582498

RESUMO

BACKGROUND: Open reduction and internal fixation (ORIF) is a common treatment for mandibular angle fractures. It is unknown, however, whether the insertional torque of the fixation screws is a risk factor for postoperative complications. PURPOSE: The purpose of the study was to determine the association between fixation screw insertional torque and postoperative inflammatory complications (POICs). STUDY DESIGN, SETTING, SAMPLE: The authors conducted a prospective cohort study consisting of all adult patients treated with ORIF of mandibular angle fractures using a single six-hole lateral border plate secured with monocortical screws from January 1, 2020, to October 31, 2022, at a large, urban academic hospital. Patients with gunshot wounds, prolonged maxillomandibular fixation, and bilateral angle fractures were excluded. PREDICTOR VARIABLE: The predictor variables were the average and lowest insertional torque of the six screws placed for fixation during ORIF. MAIN OUTCOME VARIABLE: The outcome variable was the presence of POICs, defined as the occurrence of exposed or infected hardware, abscess formation, recurrent swelling/pain, nonunion, osteomyelitis, or fistula formation. COVARIATES: Demographics, medical history, mechanism, diagnosis, and treatment-related variables were also analyzed. ANALYSES: Descriptive and bivariate analyses were performed. A P value of ≤ .05 was considered significant. RESULTS: There were 51 patients included in the study, 37 (72.5%) men, with a mean age of 31.2 ± 10.1 years. POICs occurred in 15.7% of patients. The average insertional screw torque was 46.9 ± 7.8 Ncm, and the mean lowest insertional screw torque per plate was 34.3 ± 10.2 Ncm. The average torque values were not lower in patients who had POICs versus those who did not (45.0 ± 8.6 Ncm vs 48.4 ± 7.6 Ncm, respectively, P = .16). However, the lowest torque value was less in patients who had POICs compared to those who did not (27.5 ± 11.0 Ncm vs 35.6 ± 9.7 Ncm, respectively, P = .04). CONCLUSION AND RELEVANCE: Among patients with mandibular angle fractures treated with ORIF, decreased insertional torque for the lowest of the six screws placed for fixation was associated with complications. While previous studies have shown certain plating schemes have been associated with complications, the quality of fixation also plays a role.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Mandibulares , Complicações Pós-Operatórias , Torque , Humanos , Fraturas Mandibulares/cirurgia , Masculino , Feminino , Estudos Prospectivos , Adulto , Fixação Interna de Fraturas/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Redução Aberta/instrumentação , Redução Aberta/efeitos adversos , Placas Ósseas
4.
World J Surg Oncol ; 22(1): 266, 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39380084

RESUMO

BACKGROUND: Metastatic bone disease (MBD) and its complications have a significant impact on patients' quality of life. Pathological fractures are a particular problem as they affect patient mobility and pose a high risk of non-union. The pelvis is frequently affected by MBD and its fixation is challenging. We present a case series of three pathological sacral fractures treated with a new minimally invasive bilateral fixed angle locking system. CASE PRESENTATION: Case 1 and 2 suffered a pathological transforaminal sacral fracture without adequate trauma in stage 4 carcinomas (gastric cancer and breast cancer). Both were initially treated with non-surgical treatment, which had only a limited effect and led to imminent immobility. Both were operated on with fluoroscopic navigation and underwent transsacral SACRONAIL® stabilisation according to CT morphology (S1 + S2 and S1 respectively). Immediately after the operation, pain decreased and mobilisation improved. Case 3 had a pathological transalar sacral fracture during the 2nd cycle of chemotherapy due to non-Hodgkin's lymphoma. He soon became immobile and could only move in a wheelchair. The operation was performed with CT navigation due to the very small corridors and an implant was inserted in S1 and S2. The patient reported immediate pain relief and his ability to walk improved over the following months. Despite continued chemotherapy, no wound complications occurred. CONCLUSIONS: The cases show the advantages of the minimally invasive bilateral fixed angle locking system SACRONAIL® in the treatment of patients with pathological sacral fractures. It allows immediate full weight bearing and the risk of secondary surgical complications is low. All cases showed an improvement in pain scores and mobility.


Assuntos
Neoplasias Ósseas , Fixação Interna de Fraturas , Procedimentos Cirúrgicos Minimamente Invasivos , Ossos Pélvicos , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/complicações , Neoplasias Ósseas/secundário , Neoplasias Ósseas/patologia , Feminino , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Ossos Pélvicos/patologia , Idoso , Pessoa de Meia-Idade , Sacro/cirurgia , Sacro/lesões , Sacro/patologia , Fraturas Espontâneas/cirurgia , Fraturas Espontâneas/etiologia , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Prognóstico , Linfoma não Hodgkin/cirurgia , Linfoma não Hodgkin/patologia , Linfoma não Hodgkin/complicações , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X
5.
BMC Musculoskelet Disord ; 25(1): 526, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982393

RESUMO

BACKGROUND AND OBJECTIVE: Complex acetabular fractures involving quadrilateral areas are more challenging to treat during surgery. To date, there has been no ideal internal fixation for these acetabular fractures. The purpose of this study was to evaluate the biomechanical stability of complex acetabular fractures using a dynamic anterior titanium-plate screw system of the quadrilateral area (DAPSQ) by simulating the standing and sitting positions of pelvic specimens. MATERIALS AND METHODS: Eight formal in-preserved cadaveric pelvises aged 30-50 years were selected as the research objects. First, one hip of the normal pelvises was randomly used as the control model (group B) for measurement, and then one hip of the pelvises was randomly selected to make the fracture model in the 8 intact pelvises as the experimental model (group A) for measurement. In group A, acetabular both-column fractures in the quadrilateral area were established, and the fractures were fixed by DAPSQ. The biomechanical testing machine was used to load (simulated physiological load) from 400 N to 700 N at a 1 mm/min speed for 30 s in the vertical direction when the specimens were measured at random in simulated standing or sitting positions in groups. The horizontal displacement and longitudinal displacement of the acetabular fractures in the quadrilateral area were measured in both the standing and sitting simulations. RESULTS: As the load increased, no dislocation or internal fixation breakage occurred during the measurements. In the standing position, the horizontal displacement of the quadrilateral area fractures in group A and group B appeared to be less than 1 mm with loads ranging from 400 N to 700 N, and there was no significant difference between group A and group B (p > 0.05). The longitudinal displacement appeared to be greater than 1 mm with a load of 700 mm in group A (700 N, 2 cases), and the difference was significant between group A and group B (p < 0.05). In the sitting position, the horizontal and longitudinal displacements of the quadrilateral areas were within 0.5 mm in group A and group B, and there was no significant difference between group A and group B (p > 0.05). CONCLUSION: For complex acetabular fractures in the quadrilateral area, DAPSQ fixation may provide early sitting stability, but it is inappropriate for patients to stand too early.


Assuntos
Acetábulo , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas , Titânio , Humanos , Acetábulo/cirurgia , Acetábulo/lesões , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Adulto , Pessoa de Meia-Idade , Fraturas Ósseas/cirurgia , Fraturas Ósseas/fisiopatologia , Masculino , Feminino , Cadáver
6.
BMC Musculoskelet Disord ; 25(1): 544, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010006

RESUMO

OBJECTIVE: We aimed to compare the clinical efficacy of inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction in the healing of femoral neck fractures. METHODS: Between October 2017 and March 2021, 55 patients with femoral neck fractures underwent treatment using inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction. Among these patients, 29 received inverted triangular cannulated compression screws combined with Gotfried positive buttress reduction treatment. This group consisted of 16 males and 13 females, with an average age of 43.45 ± 8.23 years. Additionally, 26 patients received inverted triangular cannulated compression nails combined with Gotfried negative buttress reduction treatment. This group included 14 males and 12 females, with an average age of 41.96 ± 8.69 years. Postsurgery, various measurements were taken, including the degree of shortening of the femoral neck, degree of bone nonunion, degree of fixation failure, degree of ischemic necrosis of the femoral head, and Harris score of the hip joint. RESULTS: All patients were followed up for a minimum of 18 months. The group that underwent treatment with an inverted triangular cannulated compression screw combined with Gotfried positive buttress reduction did not experience any cases of bone nonunion, fixation failure, or ischemic necrosis of the femoral head. In the group that received treatment with inverted triangle cannulated compression screws combined with Gotfried negative buttress reduction, there was one case of bone nonunion, three cases of early fixation failure, and one case of ischemic necrosis. Ultimately, five patients (19.23% of the total) underwent joint replacement surgery. The average shortening lengths in the vertical plane were 4.07 ± 1.98 mm and 8.08 ± 3.54 mm, respectively. In the horizontal plane, the average shortening lengths were 3.90 ± 1.57 mm and 7.77 ± 3.31 mm, respectively. At the last follow-up, the group that received Gotfried positive buttress reduction had a greater Harris hip joint score. CONCLUSION: The success rate of combining inverted triangular cannulated compression screws with Gotfried positive buttress reduction surgery is relatively high. This surgical approach effectively prevents femoral neck shortening and improves hip joint function. Moreover, it is crucial to avoid negative buttress reduction when managing femoral neck fractures.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Consolidação da Fratura , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Seguimentos
7.
BMC Musculoskelet Disord ; 25(1): 580, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048966

RESUMO

BACKGROUND: The calcar of the proximal humerus is a fundamental structure for medial humeral column support. This study aimed to assess the outcome of osteosynthesis across cases of unstable proximal humerus fractures (PHFs) with medial calcar comminution, following treatment with a PHILOS locking plate and medial support screw (MSS). METHODS: Between January 2010 and December 2018, we retrospectively analyzed the outcomes of 121 cases of osteosynthesis for PHFs with medial column disruption. For the medial support, at least one oblique screw was inserted within 5 mm of the subchondral bone in the inferomedial quadrant of the humeral head. All patients were categorized into two groups: 26 patients in the single MSS group, and 95 in the multiple MSS group. Follow-up after at least an year involved clinical and radiographic outcome evaluations, and correspondingly measuring the Constant-Murley score, University of California, Los Angeles (UCLA) shoulder scale, pain visual analogue scale (VAS), major complications, neck-shaft angle (NSA), humeral head height (HHH), and the eventual time to bone union. Risk factors for the major complications were assessed by multivariate logistic regression analyses. RESULTS: The cohort's mean age was 64.4 ± 15.4 years, and the mean follow-up duration was 19.5 ± 7.6 months. At the final follow-up, between the single MSS and multiple MSS groups, no significant differences in the Constant-Murley score (p = 0.367), UCLA score (p = 0.558), VAS (p = 0.571), time to bone union (p = 0.621), NSA loss (p = 0.424), and HHH loss (p = 0.364) were observed. The incidence of complications (p = 0.446) based on the number of MSS were not significantly different. The initial insufficient reduction after surgery (of NSA < 125°) was found to be a significant risk factor for post-surgical complications. CONCLUSIONS: To treat unstable PHFs, the use of at least one MSS along with a locking plate system is sufficient to achieve satisfactory outcomes. Successful operative treatment using a locking plate for PHF treatment is inherent in anatomical fracture reduction, coupled with medial column support.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Seguimentos , Adulto
8.
BMC Musculoskelet Disord ; 25(1): 735, 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39277709

RESUMO

PURPOSE: This study aimed to compare the clinical outcomes and differences in biomechanical characteristics between the femoral neck system (FNS) and cannulated cancellous screws (CCSs) in the treatment of femoral neck fractures. METHODS: This study retrospectively analysed a cohort of 38 registered cases of femoral neck fractures treated surgically with either the FNS (n = 17) or CCSs (n = 21) between January 2020 and December 2023. Indicators such as fluoroscopy frequency, length of hospital stay, and fracture healing time were compared between the two groups. Functional status was evaluated via the Harris hip score (HHS) and visual analogue scale (VAS), whereas prognosis was assessed based on changes in the neck shaft angle and femoral neck shortening. Additionally, six sets of femoral neck fracture models were developed based on Pauwels angles of 30°, 40°, 50°, 60°, 70°, and 80°. Two experimental groups, FNS and CCS, were established, and a joint reaction force of 1800 N was applied to the proximal femur. The displacement, stress, and stiffness of the components of interest in the different models were tested and compared. RESULTS: The distributions of all the baseline characteristics were similar between the two groups (p > 0.05). The FNS group presented significantly shorter fluoroscopy frequency, length of hospital stay, and fracture healing time (p < 0.05). Harris and VAS scores were higher in the FNS group than in the CCS group (p < 0.05). Postoperative changes in the neck shaft angle and femoral neck shortening were significantly lower in the FNS group than in the CCS group (p < 0.05). The results of the finite element analysis indicated that the maximum stress on the femoral head and varus angle were generally lower in the FNS group than in the CCS group and that the maximum displacement of the femoral head and FNS was generally lower in the FNS group than in the CCS group. However, the superiority of FNS over CCS decreased with increasing Pauwels angle. Additionally, the effectiveness of FNS in limiting displacement of the femoral neck upper wall was not as favourable as that of CCS. CONCLUSIONS: The treatment of femoral neck fractures with FNS is superior and contributes to improved hip joint function. Biomechanical research has confirmed its structural stability and advantages in resisting femoral head varus. However, challenges to its fixation efficacy persist, particularly at higher Pauwels angles.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Fixação Interna de Fraturas , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Consolidação da Fratura , Colo do Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Tempo de Internação , Idoso de 80 Anos ou mais
9.
BMC Musculoskelet Disord ; 25(1): 446, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844920

RESUMO

BACKGROUND: Femoral neck system (FNS) has exhibited some drawbacks, such as non-fit of the plate with the lateral femoral cortex, postoperative pain, and the potential risk of subtrochanteric fractures. We have developed a low-profile FNS system that addresses some compatibility issues in FNS. In this study, we conducted finite element analysis on the 1-hole FNS (1 H-FNS), 2-holes FNS (2 H-FNS), and low-profile FNS (LP-FNS) and compared their biomechanical performance. METHODS: After the mesh convergence analysis, we established three groups of 1 H-FNS, 2 H-FNS, and LP-FNS. The interfragmentary gap, sliding distance, shear stress, and compressive stress and the bone-implant interface compression stress, stiffness, and displacement were determined under the neutral, flexion, or extension conditions of the hip joint, respectively. The stress and displacement of the femur after the implant removal were also investigated. RESULTS: (1) There were no obvious differences among the three FNS groups in terms of the IFM distance. However, the LP-FNS group showed less rotational angle compared with conventional FNS (neutral: 1 H-FNS, -61.64%; 2 H-FNS, -45.40%). Also, the maximum bone-implant interface compression stress was obviously decreased under the neutral, flexion, or extension conditions of the hip joint (1 H-FNS: -6.47%, -20.59%, or -4.49%; 2 H-FNS: -3.11%, 16.70%, or -7.03%; respectively). (2) After the implant removal, there was no notable difference in the maximum displacement between the three groups, but the maximum von Mises stress displayed a notable difference between LP-FNS and 1 H-FNS groups (-15.27%) except for the difference between LP-FNS and 2 H-FNS groups (-4.57%). CONCLUSIONS: The LP-FNS may not only provide the same biomechanical stabilities as the 1 H-FNS and 2 H-FNS, but also have more advantages in rotational resistance especially under the neutral condition of the hip joint, in the bone-implant interface compression stress, and after the implant removal. In addition, the 1 H-FNS and 2 H-FNS have similar biomechanical stabilities except for the maximum von Mises stress after the implant removal. The femur after the LP-FNS removal not only is subjected to relatively little stress but also minimizes stress concentration areas.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Análise de Elementos Finitos , Humanos , Fraturas do Colo Femoral/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Estresse Mecânico , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia
10.
BMC Musculoskelet Disord ; 25(1): 320, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654260

RESUMO

BACKGROUND: The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures. METHODS: A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded. RESULTS: A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016). CONCLUSION: Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
11.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702748

RESUMO

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Ossos Metacarpais , Ossos Metacarpais/lesões , Ossos Metacarpais/cirurgia , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia
12.
BMC Musculoskelet Disord ; 25(1): 368, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730497

RESUMO

BACKGROUND: This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation. METHODS: The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected. RESULTS: Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score. CONCLUSION: In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique. TRIAL REGISTRATION: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).


Assuntos
Cimentos Ósseos , Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Cimentos Ósseos/uso terapêutico , Cimentos Ósseos/efeitos adversos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Reoperação
13.
BMC Musculoskelet Disord ; 25(1): 780, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39363345

RESUMO

BACKGROUND: Management of syndesmotic injuries with screw fixation has potential disadvantages, which may lead to the loss of some of the ankle functions. The use of the suture-button system instead can overcome these disadvantages. PATIENTS AND METHODS: In a prospective study, 32 patients with acute isolated syndesmotic injuries were treated with a suture-button device. Follow-up was for a minimum of 2 years, regarding the Visual Analogue Scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, patient satisfaction at 3, 12, and 24 months, and radiological assessment. RESULT: A significant improvement regarding pain (VAS during rest 5.6 and during walking 6.1 preoperative improved to 0.1 and 0.2 postoperatively, respectively. (P values were < 0.0001 for both pain during rest and walking) and AOFAS score (improved significantly from 44 ± 7.5 pre- to 99 ± 8.7 points postoperatively (P value was 0.0034). The improved VAS and AOFAS scores of the repaired ankles gradually reached the values of the contralateral uninjured ankle (evaluated at 3,12, and 24 months, postoperatively). Radiographs and CT of both ankles - repaired and healthy ankles - were similar at the 3 months follow-up. Early full weight-bearing and early return to work and sport characterized all patients. There was no need for hardware removal. CONCLUSION: Suture-button treatment for acute isolated ankle syndesmotic injuries leads to favorable clinical and radiological outcomes. Postoperative radiographs and CT denoted maintained ankle stability. Patients can do early full weight-bearing and early return to work and sport.


Assuntos
Traumatismos do Tornozelo , Humanos , Masculino , Adulto , Feminino , Estudos Prospectivos , Traumatismos do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Resultado do Tratamento , Pessoa de Meia-Idade , Adulto Jovem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Seguimentos , Técnicas de Sutura/instrumentação , Medição da Dor , Parafusos Ósseos , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Adolescente
14.
BMC Musculoskelet Disord ; 25(1): 789, 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39367368

RESUMO

BACKGROUND: Despite the explicit biomechanical advantages associated with FNS, it is currently inconclusive, based on the existing literature, whether Femoral Neck System (FNS) outperforms Cannulated cancellous screws (CSS) in all aspects. Due to variances in bone morphology and bone density between the elderly and young cohorts, additional research is warranted to ascertain whether the benefits of FNS remain applicable to elderly osteoporosis patients. This study aimed to investigate the biomechanical properties of FNS in osteoporotic femoral neck fractures and propose optimization strategies including additional anti-rotation screw. METHODS: The Pauwels type III femoral neck fracture models were reconstructed using finite element numerical techniques. The CSS, FNS, and modified FNS (M-FNS) models were created based on features and parameterization. The various internal fixations were individually assembled with the assigned normal and osteoporotic models. In the static analysis mode, uniform stress loads were imposed on all models. The deformation and stress variations of the femur and internal fixation models were recorded. Simultaneously, descriptions of shear stress and strain energy were also incorporated into the figures. RESULTS: Following bone mass reduction, deformations in CSS, FNS, and M-FNS increased by 47%, 52%, and 40%, respectively. The equivalent stress increments for CSS, FNS, and M-FNS were 3%, 43%, 17%, respectively. Meanwhile, variations in strain energy and shear stress were observed. The strain energy increments for CSS, FNS, and M-FNS were 4%, 76%, and 5%, respectively. The shear stress increments for CSS, FNS, and M-FNS were 4%, 65% and 44%, respectively. Within the osteoporotic model, M-FNS demonstrated the lowest total displacement, shear stress, and strain energy. CONCLUSION: Modified FNS showed better stability in the osteoporotic model (OM). Using FNS alone may not exhibit immediate shear resistance advantages in OM. Concurrently, the addition of one anti-rotation screw can be regarded as a potential optimization choice, ensuring a harmonious alignment with the structural characteristics of FNS.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Análise de Elementos Finitos , Fixação Interna de Fraturas , Fraturas por Osteoporose , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fenômenos Biomecânicos , Estresse Mecânico , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Idoso , Densidade Óssea , Feminino
15.
BMC Musculoskelet Disord ; 25(1): 564, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39033113

RESUMO

OBJECTIVE: The objective of this study was to investigate the initial stability of different screw placements in arthroscopic anterior cruciate ligament (ACL) tibial avulsion fracture fixation. METHODS: A three-dimensional knee model at 90° flexion was utilized to simulate type III ACL tibial avulsion fracture and arthroscopic screw fixation through different portals, namely the central transpatellar tendon portal (CTP), anterolateral portal (ALP), anteromedial portal (AMP), lateral parapatellar portal (LPP), medial parapatellar portal (MPP), lateral suprapatellar portal (LSP), medial suprapatellar portal (MSP). A shear force of 450 N was applied to the finite element models at 30° flexion to simulate the failure condition. The displacement of the bony fragment and the volume of the bone above 25,000 µ-strain (damaged bone volume) were calculated around the screw path. RESULTS: When the screw was implanted through CTP, the displacement of the bony fragment reached the maximum displacement which was 1.10 mm and the maximum damaged bone volume around the screw path was 148.70 mm3. On the other hand, the minimum displacement of the bony fragment was 0.45 mm when the screw was implanted through LSP and MSP. The minimum damaged bone volume was 14.54 mm3 around the screw path when the screw was implanted through MSP. CONCLUSION: Screws implanted through a higher medial portal generated less displacement of the bony fragment and a minimum detrimental strain around the screw path. The findings are clinically relevant as they provide biomechanical evidence on optimizing screw placement in arthroscopic ACL tibial avulsion fracture fixation.


Assuntos
Artroscopia , Parafusos Ósseos , Análise de Elementos Finitos , Fixação Interna de Fraturas , Fratura Avulsão , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Artroscopia/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fratura Avulsão/cirurgia , Fratura Avulsão/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Fenômenos Biomecânicos , Ligamento Cruzado Anterior/cirurgia , Ligamento Cruzado Anterior/fisiopatologia
16.
BMC Musculoskelet Disord ; 25(1): 591, 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39068403

RESUMO

OBJECTIVE: With the development of surgical technology, the level of digital medicine is constantly improving. The birth of new technologies has a certain impact on traditional methods. At present, robot-assisted technology has been applied to patients with calcaneal fractures, which poses a challenge to traditional surgery. We aimed to assess whether robot-assisted internal fixation confers certain surgical advantages through a literature review. DESIGN: The databases PubMed, EMBASE, the Cochrane Library, the China National Knowledge Infrastructure (CNKI), and the Wanfang Data Knowledge Service Platform were systematically searched for both randomized and nonrandomized studies involving patients with calcaneal fractures. MAIN RESULTS: Five studies were identified that compared clinical indexes. For the clinical indexes, robot-assisted surgery is generally feasible because of intraoperative fluoroscopy, complications, the Gissane angle, the calcaneal width, and the American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score 3 and 6 months after the operation (P < 0.05). However, on the operation time, Böhler's angle at 3 and 6 months, Gissane angle and calcaneal width at 6 months after the operation did not show good efficacy compared with those of the traditional group (P > 0.05). CONCLUSIONS: Based on the current evidence, the advantages of robot-assisted fixation over traditional fixation are clear. The long-term clinical effects of the two methods are also good, and the short-term effect of robot assistance is better. However, the quality of some studies is low, and more high-quality randomized controlled trials (RCTs) are needed for further verification.


Assuntos
Calcâneo , Fixação Interna de Fraturas , Fraturas Ósseas , Procedimentos Cirúrgicos Robóticos , Humanos , Calcâneo/lesões , Calcâneo/cirurgia , Calcâneo/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento
17.
BMC Musculoskelet Disord ; 25(1): 533, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992608

RESUMO

BACKGROUND: The purpose of this study was to perform a biomechanical analysis to compare different medial column fixation patterns for valgus pilon fractures in a case-based model. METHODS: Based on the fracture mapping, 48 valgus pilon fracture models were produced and assigned into four groups with different medial column fixation patterns: no fixation (NF), K-wires (KW), intramedullary screws (IS), and locking compression plate (LCP). Each group contained wedge-in and wedge-out subgroups. After fixing each specimen on the machine, gradually increased axial compressive loads were applied with a load speed of one millimeter per minute. The maximum peak force was set at 1500 N. Load-displacement curves were generated and the axial stiffness was calculated. Five different loads of 200 N, 400 N, 600 N, 800 N, 1000 N were selected for analysis. The specimen failure was defined as resultant loading displacement over 3 mm. RESULTS: For the wedge-out models, Group-IS showed less displacement (p < 0.001), higher axial stiffness (p < 0.01), and higher load to failure (p < 0.001) than Group-NF. Group-KW showed comparable displacement under loads of 200 N, 400 N and 600 N with both Group-IS and Group-LCP. For the wedge-in models, no statistical differences in displacement, axial stiffness, or load to failure were observed among the four groups. Overall, wedge-out models exhibited less axial stiffness than wedge-in models (all p < 0.01). CONCLUSIONS: Functional reduction with stable fixation of the medial column is essential for the biomechanical stability of valgus pilon fractures and medial column fixation provides the enough biomechanical stability for this kind of fracture in the combination of anterolateral fixation. In detail, the K-wires can provide a provisional stability at an early stage. Intramedullary screws are strong enough to provide the medial column stability as a definitive fixation. In future, this technique can be recommended for medial column fixation as a complement for holistic stability in high-energy valgus pilon fractures.


Assuntos
Placas Ósseas , Fraturas da Tíbia , Humanos , Fenômenos Biomecânicos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/fisiopatologia , Fios Ortopédicos , Masculino , Suporte de Carga , Feminino , Adulto , Pessoa de Meia-Idade
18.
BMC Musculoskelet Disord ; 25(1): 552, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39014409

RESUMO

BACKGROUND: To evaluate the effectiveness of a sequential internal fixation strategy and intramedullary nailing with plate augmentation (IMN/PA) for bone reconstruction in the management of infected femoral shaft defects using the Masquelet technique. METHODS: We performed a retrospective descriptive cohort study of 21 patients (mean age, 36.4 years) with infected bone defects of the femoral shaft treated by the Masquelet technique with a minimum follow-up of 18 months after second stage. After aggressive debridement, temporary stabilisation (T1) was achieved by an antibiotic-loaded bone cement spacer and internal fixation with a bone cement-coated locking plate. At second stage (T2), the spacer and the locking plate were removed following re-debridement, and IMN/PA was used as definitive fixation together with bone grafting. We evaluated the following clinical outcomes: infection recurrence, bone union time, complications, and the affected limb's knee joint function. RESULTS: The median and quartiles of bone defect length was 7 (4.75-9.5) cm. Four patients required iterative debridement for infection recurrence after T1. The median of interval between T1 and T2 was 10 (9-19) weeks. At a median follow-up of 22 (20-27.5) months, none of the patients experienced recurrence of infection. Bone union was achieved at 7 (6-8.5) months in all patients, with one patient experiencing delayed union at the distal end of bone defect due to screws loosening. At the last follow-up, the median of flexion ROM of the knee joint was 120 (105-120.0)°. CONCLUSIONS: For infected femoral shaft bone defects treated by the Masquelet technique, sequential internal fixation and IMN/PA for the reconstruction can provide excellent mechanical stability, which is beneficial for early functional exercise and bone union, and does not increase the rate of infection recurrence.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Desbridamento , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Masculino , Estudos Retrospectivos , Feminino , Adulto , Fraturas do Fêmur/cirurgia , Pessoa de Meia-Idade , Desbridamento/métodos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Adulto Jovem , Resultado do Tratamento , Transplante Ósseo/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Seguimentos , Cimentos Ósseos/uso terapêutico , Antibacterianos/uso terapêutico , Antibacterianos/administração & dosagem , Fêmur/cirurgia , Adolescente
19.
BMC Musculoskelet Disord ; 25(1): 683, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39210474

RESUMO

PURPOSE: This study investigated the clinical and functional outcomes of children with distal both-bone forearm fractures treated by fixation of the radius only compared to fixation of both the radius and ulna. METHODS: A total of 71 patients from two centres with distal both-bone forearm fractures (30 in the ulna-yes group, 41 in the ulna-no group) who underwent closed reduction and percutaneous pinning treatment were retrospectively analysed. Operation duration, number of fluoroscopic exposures, loss of reduction rate and angulation based on radiographic assessment were compared between the two groups. Evaluation of wrist function including Gartland-Werley Score and Mayo Wrist Score were compared at the last follow-up. RESULTS: Ulna angulation upon bone healing on the posteroanterior and the lateral plane of ulna-no group (6.11 ± 1.56°; 6.51 ± 1.69°) was significantly greater than that of ulna-yes group (4.49 ± 1.30°; 5.05 ± 2.18°) (p < 0.05). No significant difference was found in the loss of reduction rate between ulna-yes group (6.67%, 2/30) and the ulna-no group (4.88%, 2/41) (p > 0.05). At last follow-up, no significant difference was found between the Gartland-Werley Scores of the ulna-yes group (1.83 ± 3.25, range: 0-16) and ulna-no group (1.85 ± 2.72, range: 0-11.5) (p > 0.05). No significant difference was found between the Mayo Wrist Scores of the ulna-yes group (92.60 ± 6.20) and ulna-no group (92.15 ± 7.58) (p > 0.05). CONCLUSIONS: For distal both-bone forearm fractures in children, fixation of only the radius appears to be a viable method with equivalent clinical outcomes compared to fixation of both the radius and ulna.


Assuntos
Pinos Ortopédicos , Fraturas do Rádio , Fraturas da Ulna , Humanos , Estudos Retrospectivos , Feminino , Masculino , Criança , Fraturas da Ulna/cirurgia , Fraturas da Ulna/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Resultado do Tratamento , Pré-Escolar , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Adolescente , Ulna/cirurgia , Ulna/diagnóstico por imagem , Ulna/lesões , Seguimentos
20.
BMC Musculoskelet Disord ; 25(1): 750, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39294635

RESUMO

BACKGROUND: Plates and screws are frequently used for the fixation of displaced intra-articular calcaneus fracture (DIACF). In this study, we compared the outcomes of a modified screw fixation technique with plate fixation via a sinus tarsi approach (STA). METHODS: A series of 187 DIACF patients who were treated via an STA using a plate fixation (n = 81) or a screw fixation (n = 106) were included. Screw fixation was done with two 2.7 mm screws and two 6.5 mm cannulated screws. Outcomes were evaluated radiographically and clinically. Clinical evaluations included pain assessment by Visual Analogue Scale (VAS) and functional assessment by the American Orthopaedic Foot and Ankle Society (AOFAS) questionnaire and Foot Function Index (FFI). RESULTS: The mean final VAS was smaller in the screw group (P = 0.01). The mean AOFAS and FFI scores were not significantly different between the two groups (P = 0.17 and P = 0. 19, respectively). The mean improvement of Bohler's angle, but not the Gissane's angle, was significantly greater in the screw group (P = 0.014 and P = 0.09, respectively). The mean improvement of calcaneal length and height were not significantly different between the two groups (P = 0.78 and P = 0.22, respectively). The hardware removal rate was 14.8% in the plate group and 3.8% in the screw group (P = 0.007). CONCLUSION: The modified screw fixation method provides lower pain, better radiographic outcome, and lower rate of hardware removal compared to plate fixation in the treatment of DIACF.


Assuntos
Placas Ósseas , Parafusos Ósseos , Calcâneo , Fixação Interna de Fraturas , Fraturas Intra-Articulares , Humanos , Calcâneo/cirurgia , Calcâneo/lesões , Calcâneo/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fraturas Intra-Articulares/cirurgia , Fraturas Intra-Articulares/diagnóstico por imagem , Resultado do Tratamento , Idoso , Estudos Retrospectivos , Fraturas Ósseas/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Radiografia , Adulto Jovem , Medição da Dor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA