RESUMO
PURPOSE: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). METHODS: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. RESULTS: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up. CONCLUSION: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm. TRIAL REGISTRATION: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018).
Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Hólmio , Neoplasias Hepáticas , Radioisótopos , Humanos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/terapia , Masculino , Hólmio/uso terapêutico , Feminino , Idoso , Pessoa de Meia-Idade , Embolização Terapêutica/métodos , Radioisótopos/uso terapêutico , Radioisótopos/administração & dosagem , Ablação por Radiofrequência/métodos , Dosagem Radioterapêutica , Estadiamento de Neoplasias , Distribuição TecidualRESUMO
PURPOSE: Aim of this study was to investigate a dose-response relationship, dose-toxicity relationship, progression free survival (PFS) and overall survival (OS) in neuroendocrine tumour liver metastases (NELM) treated with holmium-166-microspheres radioembolization ([166Ho]-radioembolization). MATERIALS AND METHODS: Single center, retrospective study included patients with NELM that received [166Ho]-radioembolization with post-treatment SPECT/CT and CECT or MRI imaging for 3 months follow-up. Post-treatment SPECT/CT was used to calculate tumour (Dt) and whole liver healthy tissue (Dh) absorbed dose. Clinical and laboratory toxicity was graded by Common Terminology Criteria for Adverse Events (CTCAE), version 5 at baseline and three-months follow-up. Response was determined according to RECIST 1.1. The tumour and healthy doses was correlated to lesion-based objective response and patient-based toxicity. Kaplan Meier analyses were performed for progression free survival (PFS) and overall survival (OS). RESULTS: Twenty-seven treatments in 25 patients were included, with a total of 114 tumours. Median follow-up was 14 months (3 - 82 months). Mean Dt in non-responders was 68 Gy versus 118 Gy in responders, p = 0.01. ROC analysis determined 86 Gy to have the highest sensitivity and specificity, resp. 83% and 81%. Achieving a Dt of ≥ 120 Gy provided the highest likelihood of response (90%) for obtaining response. Sixteen patients had grade 1-2 clinical toxicity and only one patient grade 3. No clear healthy liver dose-toxicity relationship was found. The median PFS was 15 months (95% CI [10.2;19.8]) and median OS was not reached. CONCLUSION: This study confirms the safety and efficacy of [166Ho]-radioembolization in NELM in a real-world setting. A clear dose-response relationship was demonstrated and future studies should aim at a Dt of ≥ 120 Gy, being predictive of response. No dose-toxicity relationship could be established.
Assuntos
Embolização Terapêutica , Hólmio , Neoplasias Hepáticas , Tumores Neuroendócrinos , Humanos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Embolização Terapêutica/efeitos adversos , Adulto , Estudos Retrospectivos , Hólmio/uso terapêutico , Radioisótopos/uso terapêutico , Radioisótopos/efeitos adversos , Relação Dose-Resposta à Radiação , Idoso de 80 Anos ou mais , Resultado do Tratamento , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton ÚnicoRESUMO
OBJECTIVE: To investigate the feasibility, safety and efficacy of holmium laser enucleation of the prostate (HoLEP) in the re-treatment setting (salvage HoLEP) and compare it to the primary HoLEP procedure that is commonly used for the treatment of benign prostate hyperplasia (BPH). MATERIALS AND METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, PubMed, Scopus, and Cochrane databases were systematically screened, from inception to 8 August 2022. Other potentially eligible studies were retrieved using the reference lists of the included studies. Retrospective and prospective studies, both comparative and non-comparative, were included. RESULTS: A total of 12 studies met the inclusion criteria and were included in the final qualitative synthesis. One study was prospective comparative (non-randomised), seven studies were retrospective comparative, and four studies were retrospective non-comparative or case series. In total, 831 patients were treated with salvage HoLEP in the above studies. Previous intervention before salvage HoLEP ranged among studies. The most commonly performed was transurethral resection of the prostate. Intraoperative parameters of salvage HoLEP were comparable with those reported during primary HoLEP, while all postoperative outcomes were significantly improved after salvage HoLEP and were similar with those observed after primary HoLEP. No major complications were noted after salvage HoLEP according to Clavien-Dindo classification. CONCLUSIONS: Salvage HoLEP after previous interventions for treating recurrent or residual BPH is a feasible, safe, and efficient procedure. Data presented in selected studies, along with the holmium laser's physical properties to resect more tissue and to dissect along the true anatomical plane of BPH, render HoLEP an ideal salvage treatment modality for recurrent or residual BPH symptoms.
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Humanos , Masculino , Hólmio , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Estudos Prospectivos , Próstata , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Ressecção Transuretral da Próstata/métodos , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the cooling effect and other advantages of a novel circulation system for ureteroscopic holmium laser lithotripsy (URSL) in a standardized in vitro model. MATERIALS AND METHODS: The novel circulation system was assembled by connecting a 4Fr ureteral catheter and a filter. Trails were divided into a new URSL group and a conventional URSL group. First, different power settings (18-30 W) of the holmium laser and irrigation flow rates (20-50 mL/min) were used to evaluate the thermal effect on the lithotripsy site of all groups. Then, renal pelvic temperature and pressure were assessed during URSL at a power of 1.5 J/20 Hz and irrigation flow rates of (20-50 mL/min). Finally, the whole process of lithotripsy was performed at 1.5 J/20 Hz (operator duty cycle ODC: 50%) with an irrigation flow rate of 30 mL/min. The time required for lithotripsy, visual field clarity, and stone migration were observed. RESULTS: Temperature of the lithotripsy point was significantly lower in the new URSL group than in the conventional group (P < 0.05) with irrigation rates (20, 30 mL/min). The renal pelvic pressure of the new group was significantly lower than that of the conventional group in which intrarenal hypertension developed at an irrigation rate of 50 ml/min. The new group had better visual clarity and lesser stone upward migration when lithotripsy was performed at 1.5 J/20 Hz and 30 ml/min. CONCLUSION: The novel circulation system is more effective in reducing the thermal effects of URSL, pelvic pressure, stone upward migration, and improving the visual clarity of the operative field.
Assuntos
Hipertensão , Litotripsia a Laser , Litotripsia , Humanos , Ureteroscopia , HólmioRESUMO
PURPOSE: To evaluate factors that effectively predict indistinct plane (IP) in patients who underwent holmium laser enucleation of the prostate (HoLEP). METHODS: Data of 208 consecutive patients from our HoLEP database were reviewed and analyzed. IP was defined in 107 cases, as the plane could be identified only depending on endoscopic beak dissection rather than laser dissection in the initial stage of HoLEP, whereas the control group consisted of 101 cases. Variables including age, body mass index, prostatic volume (PV), intravesical prostatic protrusion, prostate-specific antigen, prostate-specific antigen density, bladder stones, urinary tract infection, microscopic hematuria, prior biopsy (PB), diabetes, hypertension, history of acute urinary retention, 5-alpha reductase inhibitor treatment, catheter dependency, residual urine, region, smoking, and alcohol consumption were compared between the two groups. The risk factors for predicting the presence of IP were determined using a multivariable binary logistic regression model using a forward selection approach with a focus on improvement in the area under the receiver operating characteristic curve (AUC). RESULTS: The incidence of IP was 51.4% (107/208). PV (OR = 0.977, p < 0.001) and PB (OR = 0.297, p = 0.028) were identified as the independent predictors of capsule plane status. PV with a cutoff of 54 ml had the best predictive effectiveness for IP based on AUC (0.727; 95% CI 0.659-0.795). The specificity and sensitivity of this cutoff were 82.2% and 53.3%, respectively. CONCLUSION: PV is the most reliable factor to predict IP during HoLEP procedures. There is a high possibility of IP in patients with a PV less than 54 ml.
Assuntos
Terapia a Laser , Antígeno Prostático Específico , Animais , Masculino , Humanos , Procedimentos Cirúrgicos Urológicos , Biópsia , Dissecação , HólmioRESUMO
PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.
Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , LasersRESUMO
PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.
Assuntos
Alumínio , Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Ítrio , Humanos , Túlio , Urolitíase/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tecnologia , HólmioRESUMO
PURPOSE: To evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage. METHODS: Utilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone. RESULTS: Temperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%. CONCLUSION: Temperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.
Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Modelos AnatômicosRESUMO
INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Nefrolitíase , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio , Cistina , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico , HólmioRESUMO
PURPOSE: To compare vapor tunnel (VT) and virtual basket (VB) tools to reduce retropulsion in the treatment of proximal ureteral stones. METHODS: Patients with a single proximal ureteral stone were randomly assigned to holmium laser lithotripsy with the use of VT (Group A) or VB (Group B) tool. The 150W holmium:YAG cyber Ho generator was used. We compared operative time, dusting time, need for flexible ureteroscopy due to stone push-up and occurrence of ureteral lesions. The stone-free rate (SFR) and the occurrence of postoperative ureteral strictures were assessed. RESULTS: 186 patients were treated, of which 92 with the VT (49.5%, Group A) and 94 with the VB (50.5%, Group B). Mean stone size was 0.92 vs. 0.91 cm in Groups A vs. B (p = 0.32). Mean total operative time and dusting time were comparable between groups. 7 (7.6%) vs. 6 (6.4%) patients in Groups A vs. B required a flexible ureteroscope because of stone push-up (p = 0.12). Ureteral mucosa lesions were observed in 15 (16.3%) vs. 18 (19.1%) cases in the VT vs. VB group (p = 0.09). 1-Month SFR was comparable (97.8% vs. 95.7%, p = 0.41). We observed one case (1.1%) of postoperative ureteral stricture in the VT group vs. two cases (2.1%) in the VB group (p = 0.19). CONCLUSIONS: VT and VB are equally safe and effective tools in reducing retropulsion of ureteral stones. Operative time, dusting time and SFR were comparable. They also equally avoided stone push-up and prevented ureteral lesions, which may later occur in ureteral strictures.
Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Ureterais , Humanos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Constrição Patológica/etiologia , Ureteroscopia/efeitos adversos , Resultado do Tratamento , Cálculos Ureterais/cirurgia , Litotripsia a Laser/efeitos adversos , Complicações Pós-Operatórias/etiologiaRESUMO
PURPOSE: To clinically and histologically characterize prostatic nodules resistant to morcellation ("beach balls," BBs). PATIENTS AND METHODS: We reviewed a consecutive cohort of 559 holmium laser enucleation of the prostate (HoLEP) procedures performed between January 2020 and November 2023. The BBs group comprised 55 men (10%) and the control group comprised 504 men (90%). The clinical, intraoperative, outcome, and histologic data were statistically processed for the prediction of the presence of BBs and their influence on the perioperative course and outcome. RESULTS: The BBs group in comparison to the controls was older (75 vs 73 years, respectively, p = 0.009) and had higher rates of chronic retention (51 vs 29%, p = 0.001), larger prostates on preoperative abdominal ultrasound (AUS) (140 vs 80 cc, p = 0.006E-16), longer operating time (120 vs 80 min, p = 0.001), higher weights of removed tissue (101 vs 60 gr, p = 0.008E-10), higher complication rates (5 vs 1%, p = 0.03), and longer hospitalization (p = 0.014). A multivariate analysis revealed that larger prostates on preoperative AUS and older age independently predicted the presence of BBs which would prolong operating time. ROC analyses revealed that a threshold of 103 cc on AUS predicted BBs with 94% sensitivity and 84% specificity. BBs were mostly characterized histologically by stromal component (p = 0.005). CONCLUSIONS: BBs are expected in older patients and cases of chronic retention. Prostatic volume is the most reliable predictor of their presence. They contribute to prolonged operating time and increased risk of complications. The predominantly stromal composition of the BBs apparently confers their resistance to morcellation.
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Idoso , Humanos , Masculino , Hólmio , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Próstata/cirurgia , Próstata/patologia , Prostatectomia/métodos , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Ressecção Transuretral da Próstata/métodos , Resultado do TratamentoRESUMO
PURPOSE: Holmium laser enucleation of the prostate (HoLEP) represents the current standard procedure for size-independent surgical therapy of benign prostatic obstruction (BPO). With advent of the novel laser technology thulium fiber laser (TFL), we hypothesized that the functional outcome of TFL enucleation of the prostate (ThuFLEP) is non-inferior compared to HoLEP. METHODS: From October 2021 to October 2022, 150 patients with BPO were recruited for the prospective randomized trial in accordance with CONSORT. Stratified randomization into the arms ThuFLEP (n = 74) or HoLEP (n = 76) was carried out. The primary endpoint was non-inferior international prostate symptom score (IPSS) and quality of life (QoL) at three months after treatment. Secondary endpoints were rates of complications, peak flow, residual urine and operation times. RESULTS: Preoperative characteristics showed no significant differences. Overall IPSS and QoL improved from 21 to 8 and 4 to 1.5, respectively, after three months of follow-up. No statistically significant differences between ThuFLEP and HoLEP were observed regarding median postoperative IPSS (8.5 vs. 7, p > 0.9), QoL (1 vs. 2, p = 0.6), residual urine (48 vs. 30ml, p = 0.065) and peak flow (19 vs. 17ml/s, p > 0.9). Similarly, safety profile was comparable with no statistically significant differences regarding rate of major complications (5.3 vs. 5.4%, p = 0.5), laser hemostasis time (3 vs. 2min, p = 0.2), use of additive electric coagulation (74 vs. 87%, p = 0.06) or electric coagulation time (8 vs. 8min, p = 0.4). CONCLUSIONS: In this prospective, randomized trial ThuFLEP showed non-inferior results compared to HoLEP in terms of functional outcomes measured by IPSS and QoL as primary endpoint. TRIAL REGISTRATION NUMBER: DRKS00032699 (18.09.2023, retrospectively registered).
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Retenção Urinária , Masculino , Humanos , Próstata/cirurgia , Lasers de Estado Sólido/uso terapêutico , Túlio/uso terapêutico , Qualidade de Vida , Hiperplasia Prostática/complicações , Estudos Prospectivos , Resultado do Tratamento , Terapia a Laser/métodos , Retenção Urinária/cirurgia , HólmioRESUMO
INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is an established option in the surgical treatment of benign prostatic hyperplasia. Pulse modulation, such as MOSES® technology, has recently been introduced and may offer potential advantages in HoLEP. METHODS: Perioperative data from 117 patients who underwent MOSES® laser enucleation of the prostate (MoLEP) were collected. Propensity score matching using prostate volume, age, body mass index (BMI), and anticoagulant intake was performed using a database of 237 patients treated with HoLEP. In total, 234 patients were included in the analysis. RESULTS: Prostate volume (104 vs. 102 ml), age (70 vs. 71 years), BMI (27 vs. 27), and anticoagulant intake (34 vs. 35%) did not differ significantly between the groups. There were no significant differences in operation time (61.5 vs. 58.1 min, p = 0.42), enucleation efficiency (2.5 vs. 2.6 g/min, p = 0.74), hemostasis time (7.8 vs. 8 min, p = 0.75) and hemoglobin drop (0.9 vs. 0.7 mg/dl, p = 0.48). The complication rates were low in both groups (16.2% for HoLEP and 17.1% for MoLEP). No differences were noted in the Clavien-Dindo Classification (p = 0.63) and the Comprehensive Complication Index (p = 0.24). The rate of complications > CDC IIIa was 0.9% for HoLEP (endoscopic coagulation) and 1.7% for MoLEP (2 cases of endoscopic coagulation). No transfusions were administered. CONCLUSION: Overall, the enucleation efficiency was high in both groups and the procedure time was short. HoLEP is an efficient and safe treatment option in experienced hands, regardless of the use of pulse modulation technology.
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Hólmio , Pontuação de Propensão , Resultado do Tratamento , Lasers de Estado Sólido/uso terapêutico , Qualidade de Vida , Hiperplasia Prostática/complicações , Ressecção Transuretral da Próstata/métodos , Terapia a Laser/métodos , AnticoagulantesRESUMO
BACKGROUND: Early angiogenesis provides nutrient supply for bone tissue repair, and insufficient angiogenesis will lead tissue engineering failure. Lanthanide metal nanoparticles (LM NPs) are the preferred materials for tissue engineering and can effectively promote angiogenesis. Holmium oxide nanoparticles (HNPs) are LM NPs with the function of bone tissue "tracking" labelling. Preliminary studies have shown that HNPs has potential of promote angiogenesis, but the specific role and mechanism remain unclear. This limits the biological application of HNPs. RESULTS: In this study, we confirmed that HNPs promoted early vessel formation, especially that of H-type vessels in vivo, thereby accelerating bone tissue repair. Moreover, HNPs promoted angiogenesis by increasing cell migration, which was mediated by filopodia extension in vitro. At the molecular level, HNPs interact with the membrane protein EphrinB2 in human umbilical vein endothelial cells (HUVECs), and phosphorylated EphrinB2 can bind and activate VAV2, which is an activator of the filopodia regulatory protein CDC42. When these three molecules were inhibited separately, angiogenesis was reduced. CONCLUSION: Overall, our study confirmed that HNPs increased cell migration to promote angiogenesis for the first time, which is beneficial for bone repair. The EphrinB2/VAV2/CDC42 signalling pathway regulates cell migration, which is an important target of angiogenesis. Thus, HNPs are a new candidate biomaterial for tissue engineering, providing new insights into their biological application.
Assuntos
Materiais Biocompatíveis , Movimento Celular , Hólmio , Células Endoteliais da Veia Umbilical Humana , Neovascularização Fisiológica , Engenharia Tecidual , Engenharia Tecidual/métodos , Humanos , Animais , Hólmio/química , Movimento Celular/efeitos dos fármacos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Neovascularização Fisiológica/efeitos dos fármacos , Camundongos , Nanopartículas Metálicas/química , Óxidos/química , Óxidos/farmacologia , Efrina-B2/metabolismo , Transdução de Sinais/efeitos dos fármacos , Masculino , Nanopartículas/químicaRESUMO
BACKGROUND Patients with urolithiasis often undergo transurethral ureteroscopic holmium laser lithotripsy, a procedure that can be affected by perioperative thermal management. This study examines the impact of compound thermal insulation management on patient recovery and comfort during transurethral ureteroscopic holmium laser lithotripsy. MATERIAL AND METHODS In this study, 551 patients who underwent transurethral ureteroscopic holmium laser lithotripsy from April 2019 to December 2022 were randomly assigned to either an observation group (n=276) or control group (n=275). Both groups received routine surgical care, with the observation group additionally receiving compound thermal insulation management. We recorded and compared perioperative body temperature changes, anesthetic resuscitation indicators (bispectral index recovery time, extubation time, fully awake time, Postanesthesia Care Unit retention time), comfort level (General Comfort Questionnaire), and quality of life (Nottingham Health Profile). We also compared the incidence of complications. RESULTS There was no significant difference in body temperature between groups at the start surgery. However, the observation group showed significantly higher temperatures during and at the end of surgery. Anesthetic resuscitation indicators were significantly better in the observation group. Both groups showed improved comfort and quality of life after surgery, with more significant improvements in the observation group. The observation group also had a lower incidence of complications, such as hypothermia and rigor. CONCLUSIONS Compound thermal insulation management during transurethral ureteroscopic holmium laser lithotripsy improved perioperative temperature maintenance, accelerated postoperative recovery, reduced complication rates, and enhanced patient comfort and quality of life.
Assuntos
Anestésicos , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Litotripsia a Laser/métodos , Hólmio , Qualidade de Vida , Ureteroscopia/métodosRESUMO
STUDY OBJECTIVE: To demonstrate the safety, efficacy, and ease of hysteroscopic metroplasty using holmium:YAG (Ho:YAG) laser for treatment of septate uterus. DESIGN: Stepwise demonstration of surgical technique with narrated video footage. SETTING: Septate uterus is the most common type of uterine anomaly. The incidence of uterine septum in women presenting with infertility and recurrent abortions is 15.4% [1,2]. Hysteroscopic septal incision is associated with improvement in live-birth rate in these women [3]. Hysteroscopic metroplasty for septate uterus can be done with the use of scissors and energy sources such as monopolar and bipolar electrosurgery and lasers. Ho:YAG laser is commonly used by urologists for various surgeries because of its "Swiss Army Knife" action of cutting, coagulation, and vaporization [4]. Ho:YAG laser is known for its precision. It causes lesser depth of tissue injury and necrosis and minimal collateral thermal damage compared with the electrosurgical devices and other lasers used for hysteroscopic surgery [5-8]. This is advantageous in hysteroscopic metroplasty given that it reduces the risk of uterine perforation during surgery and hence uterine rupture in the subsequent pregnancy. Reduced collateral damage to the surrounding endometrium helps promote early endometrial healing and prevent postoperative intrauterine adhesions. A 28-year-old patient with history of 2 spontaneous abortions came to our hospital for investigations. 3D transvaginal sonography of the patient showed presence of partial septate uterus with a fundal indentation of 1.5 cm (Supplemental video 1). INTERVENTION: Diagnostic hysteroscopy followed by septal incision using Ho: YAG laser was planned. We used a 2.9 mm BETTOCCHI Hysteroscope (Karl Storz SE & Co.) with a 5 mm operative sheath. Normal saline was used as the distending medium and the intrauterine pressure was maintained at 80 to 100 mm Hg. The procedure was done under total intravenous anesthesia using propofol injection. Vaginoscopic entry into the uterus (without any cervical dilatation) showed evidence of a partial uterine septum with tubal ostia on either side of the septum. A 400 micron quartz fiber was passed through a laser guide into the 5-Fr working channel of the operative hysteroscope. Ho:YAG laser (Auriga XL 50-Watt, Boston Scientific) with power settings of 15 watts (1500 mJ energy at 10 Hz) was used. Incision of the septum was started at the apex of the septum in the midline and continued in a horizontal manner from side to side toward the base (Supplemental video 2). Incision of the septum is continued till the tip of the hysteroscope can move freely from one ostium to the other (Supplemental video 3). The operative time was 12 minutes. There were no intra- or postoperative complications. Postoperative estrogen therapy was given for 2 months in the form of estradiol valerate 2 mg (tablet, Progynova, Zydus Cadila) 12 hourly orally for 25 days and medroxyprogesterone acetate 10 mg (tablet, Meprate, Serum Institute of India, Ltd) 12 hourly orally added in the last 5 days [9]. 3D transvaginal ultrasound was done on day 8 of menses. It showed a triangular uterine cavity with a very small fundal indentation of 0.37 cm. A second look hysteroscopy that was done on day 9 of menses showed an uterine cavity of good shape and size [10]. Few fundal adhesions were seen and they were incised using Ho:YAG laser. The patient conceived 5 months after the primary surgery and delivered by cesarean section at 38 weeks, giving birth to a healthy baby of 2860 grams. There were no complications during her pregnancy and delivery. A comparative study is essential to prove its advantages over other energy sources for this surgery. CONCLUSION: Hysteroscopic metroplasty using Ho:YAG laser for treatment of septate uterus is a simple, precise, safe, and effective procedure. VIDEO ABSTRACT.
Assuntos
Aborto Habitual , Lasers de Estado Sólido , Útero Septado , Gravidez , Feminino , Humanos , Adulto , Hólmio , Cesárea , Lasers de Estado Sólido/uso terapêutico , Útero/cirurgia , Útero/anormalidades , Histeroscopia/métodos , ComprimidosRESUMO
Holmium laser enucleation of the prostate (HoLEP) is considered a size-independent technique to treat benign prostatic hyperplasia. This safe and effective procedure is increasingly being adopted in urology training programs worldwide, yet limited teaching strategies have been described. Endoscopic handling during HoLEP allows for a simultaneous interaction between the surgeon and trainee, facilitating a guided teaching strategy with increasing difficulty as experience grows. In this article, we describe our stepwise approach for teaching HoLEP as part of a structured surgical training curriculum. We also evaluate the association of our method with intraoperative efficiency parameters and immediate postoperative surgical outcomes of 200 HoLEP procedures.
Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Próstata/cirurgia , Lasers de Estado Sólido/uso terapêutico , Ressecção Transuretral da Próstata/métodos , Hiperplasia Prostática/cirurgia , Endoscopia , Terapia a Laser/métodos , Hólmio , Resultado do Tratamento , Estudos RetrospectivosRESUMO
Holmium (Ho3+)-doped boro-bismuth-germanate glasses having the chemical composition (30-x)B2O3 + 20GeO2 + 20Bi2O3 + 20Na2O + 10Y2O3 + xHo2O3, where x = 0.1, 0.5, 1.0, and 2.0 mol% were prepared by melt-quenching technique. The prepared glasses were examined for thermal, optical, vibrational, and photoluminescent properties. The prepared glasses were found to be thermally very stable. The optical bandgap and Urbach energies of 0.1 mol% Ho2O3-doped boro-bismuth-germanate glass were calculated to be 3.3 eV and 377 MeV, respectively, using the absorption spectrum. The Judd-Ofelt analysis was performed on the 0.1 mol% Ho2O3-doped glass and compared the obtained parameters with literature. The branching ratio (ß) and emission cross-section (σem) of the green band were determined to be 0.7 and 0.24 × 10-20 cm2, respectively. Under 450 nm excitation, a strong green emission around 550 nm was observed and assigned to the (5S2 + 5F4) â 5I8 (Ho3+) transition. Upon an increase of Ho2O3 content from 0.1 to 2.0 mol%, the intensities of all observed emission bands as well as decay time of the (5S2 + 5F4) â 5I8 transition have been decreased gradually. The reasons behind the decrease in emission intensity and decay time were discussed. The strong green emission suggests that these glasses may be a better option for display devices and green emission applications.
Assuntos
Bismuto , Germânio , Vidro , Hólmio , Luminescência , Hólmio/química , Vidro/química , Germânio/química , Bismuto/química , Vibração , Medições Luminescentes , Fenômenos ÓpticosRESUMO
A series of ZnCr2-xHoxSe4 microcrystalline spinels (where x = 0.05, 0.075, and 0.10) containing holmium ions in octahedral coordination were obtained by sintering of adequate reactants at high temperatures. The obtained doped materials were characterized by X-ray diffraction, Scanning Electron Microscopy, UV-Vis-NIR, molecular field approximation, and XPS spectroscopies. Their thermal properties were also investigated. The doping of the ZnCr2S4 matrix with paramagnetic Ho3+ ions with a content of not more than 0.1 and a screened 4f shell revealed a significant effect of orbital and Landau diamagnetism, a strong reduction in short-range ferromagnetic interactions, and a broadening and shift of the peak of the first critical field by simultaneous stabilization of the sharp peak in the second critical field. These results correlate well with FPLO calculations, which show that Cr sites have magnetic moments of 3.19 µB and Ho sites have significantly larger ones with a value of 3.95 µB. Zn has a negligible magnetic polarization of 0.02 µB, and Se induces a polarization of approximately -0.12 µB.
Assuntos
Hólmio , Zinco , Zinco/química , Hólmio/química , Difração de Raios X , Selênio/química , Cromo/química , Fenômenos MagnéticosRESUMO
Background and Objectives: While studies have demonstrated the efficacy of cholangioscopy-guided Holmium-Yttrium aluminum garnet (Ho:YAG) laser lithotripsy for the treatment of refractory bile duct stones, data regarding the safety of the operating parameters for laser lithotripsy are lacking. The aim of this study was to determine safe, yet effective, energy settings for Ho:YAG laser in the ex-vivo model. Materials and Methods: This ex vivo experimental study utilized the Ho:YAG laser on porcine bile duct epithelium and human gallstones. Ho:YAG laser lithotripsy was applied in different power settings from 8 to 15 Watts (W) to six explanted porcine bile ducts. Settings that appeared safe were then utilized to fragment seventy-three human gallstones. Results: The median bile duct perforation times with the Ho:YAG laser between 8-15 W were: >60 s (8 W); 23 s (9 W); 29 s (10 W); 27 s (12 W); 12 s (14 W); and 8 s (15 W). Statistically significant differences in the median perforation times were noted between 8 W vs. 15 W, 9 W vs. 15 W, 10 W vs. 15 W, and 12 W vs. 15 W (p < 0.05). When using a 365 µm Ho:YAG laser probe at 8-12 W, the fragmentation rates on various size stones were: 100% (<1.5 cm); 80-100% (1.6-2.0 cm) and 0-32% (>2.0 cm). Optimal fragmentation was seen utilizing 12 W with high energy (2.4 J) and low frequency (5 Hz) settings. Using a larger 550 µm probe at these settings resulted in 100% fragmentation of stones larger than 2 cm. Conclusions: The Ho:YAG laser appears to be safe and effective in the treatment of large bile duct stones when used between 8-12 W in 5 s bursts in an ex vivo model utilizing porcine bile ducts and human gallstones.