Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.042
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 209(11): 1328-1337, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38346178

RESUMO

Rationale: General anesthesia and mechanical ventilation have negative impacts on the respiratory system, causing heterogeneous distribution of lung aeration, but little is known about the ventilation patterns of postoperative patients and their association with clinical outcomes. Objectives: To clarify the phenotypes of ventilation patterns along a gravitational direction after surgery by using electrical impedance tomography (EIT) and to evaluate their association with postoperative pulmonary complications (PPCs) and other relevant clinical outcomes. Methods: Adult postoperative patients at high risk for PPCs, receiving mechanical ventilation on ICU admission (N = 128), were prospectively enrolled between November 18, 2021 and July 18, 2022. PPCs were prospectively scored until hospital discharge, and their association with phenotypes of ventilation patterns was studied. The secondary outcomes were the times to wean from mechanical ventilation and oxygen use and the length of ICU stay. Measurements and Main Results: Three phenotypes of ventilation patterns were revealed by EIT: phenotype 1 (32% [n = 41], a predominance of ventral ventilation), phenotype 2 (41% [n = 52], homogeneous ventilation), and phenotype 3 (27% [n = 35], a predominance of dorsal ventilation). The median PPC score was higher in phenotype 1 and phenotype 3 than in phenotype 2. The median time to wean from mechanical ventilation was longer in phenotype 1 versus phenotype 2. The median duration of ICU stay was longer in phenotype 1 versus phenotype 2. The median time to wean from oxygen use was longer in phenotype 1 and phenotype 3 than in phenotype 2. Conclusions: Inhomogeneous ventilation patterns revealed by EIT on ICU admission were associated with PPCs, delayed weaning from mechanical ventilation and oxygen use, and a longer ICU stay.


Assuntos
Impedância Elétrica , Complicações Pós-Operatórias , Respiração Artificial , Tomografia , Humanos , Masculino , Feminino , Impedância Elétrica/uso terapêutico , Pessoa de Meia-Idade , Idoso , Respiração Artificial/métodos , Estudos Prospectivos , Tomografia/métodos , Complicações Pós-Operatórias/fisiopatologia , Tempo de Internação/estatística & dados numéricos , Desmame do Respirador/métodos , Unidades de Terapia Intensiva , Adulto
2.
Am J Respir Crit Care Med ; 209(6): 670-682, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38127779

RESUMO

Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Humanos , Impedância Elétrica , Tomografia Computadorizada por Raios X/métodos , Pulmão , Insuficiência Respiratória/diagnóstico por imagem , Insuficiência Respiratória/terapia , Tomografia/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia
3.
J Neurosci ; 43(39): 6653-6666, 2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37620157

RESUMO

The impedance is a fundamental electrical property of brain tissue, playing a crucial role in shaping the characteristics of local field potentials, the extent of ephaptic coupling, and the volume of tissue activated by externally applied electrical brain stimulation. We tracked brain impedance, sleep-wake behavioral state, and epileptiform activity in five people with epilepsy living in their natural environment using an investigational device. The study identified impedance oscillations that span hours to weeks in the amygdala, hippocampus, and anterior nucleus thalamus. The impedance in these limbic brain regions exhibit multiscale cycles with ultradian (∼1.5-1.7 h), circadian (∼21.6-26.4 h), and infradian (∼20-33 d) periods. The ultradian and circadian period cycles are driven by sleep-wake state transitions between wakefulness, nonrapid eye movement (NREM) sleep, and rapid eye movement (REM) sleep. Limbic brain tissue impedance reaches a minimum value in NREM sleep, intermediate values in REM sleep, and rises through the day during wakefulness, reaching a maximum in the early evening before sleep onset. Infradian (∼20-33 d) impedance cycles were not associated with a distinct behavioral correlate. Brain tissue impedance is known to strongly depend on the extracellular space (ECS) volume, and the findings reported here are consistent with sleep-wake-dependent ECS volume changes recently observed in the rodent cortex related to the brain glymphatic system. We hypothesize that human limbic brain ECS changes during sleep-wake state transitions underlie the observed multiscale impedance cycles. Impedance is a simple electrophysiological biomarker that could prove useful for tracking ECS dynamics in human health, disease, and therapy.SIGNIFICANCE STATEMENT The electrical impedance in limbic brain structures (amygdala, hippocampus, anterior nucleus thalamus) is shown to exhibit oscillations over multiple timescales. We observe that impedance oscillations with ultradian and circadian periodicities are associated with transitions between wakefulness, NREM, and REM sleep states. There are also impedance oscillations spanning multiple weeks that do not have a clear behavioral correlate and whose origin remains unclear. These multiscale impedance oscillations will have an impact on extracellular ionic currents that give rise to local field potentials, ephaptic coupling, and the tissue activated by electrical brain stimulation. The approach for measuring tissue impedance using perturbational electrical currents is an established engineering technique that may be useful for tracking ECS volume.


Assuntos
Sono REM , Sono , Humanos , Impedância Elétrica , Sono/fisiologia , Sono REM/fisiologia , Encéfalo/fisiologia , Vigília/fisiologia , Hipocampo
4.
J Cell Mol Med ; 28(14): e18545, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39031471

RESUMO

Hypoxia plays an important role in the pathological process of bladder outlet obstruction. Previous research has mostly focused on the dysfunction of bladder smooth muscle cells, which are directly related to bladder contraction. This study delves into the barrier function changes of the urothelial cells under exposure to hypoxia. Results indicated that after a 5-day culture, SV-HUC-1 formed a monolayer and/or bilayer of cell sheets, with tight junction formation, but no asymmetrical unit membrane was observed. qPCR and western blotting revealed the expression of TJ-associated proteins (occludin, claudin1 and ZO-1) was significantly decreased in the hypoxia group in a time-dependent manner. No expression changes were observed in uroplakins. When compared to normoxic groups, immunofluorescent staining revealed a reduction in the expression of TJ-associated proteins in the hypoxia group. Transepithelial electrical resistance (TEER) revealed a statistically significant decrease in resistance in the hypoxia group. Fluorescein isothiocyanate-conjugated dextran assay was inversely proportional to the results of TEER. Taken together, hypoxia down-regulates the expression of TJ-associated proteins and breaks tight junctions, thus impairing the barrier function in human urothelial cells.


Assuntos
Hipóxia Celular , Proteínas de Junções Íntimas , Junções Íntimas , Urotélio , Humanos , Urotélio/metabolismo , Urotélio/patologia , Junções Íntimas/metabolismo , Proteínas de Junções Íntimas/metabolismo , Proteínas de Junções Íntimas/genética , Linhagem Celular , Proteína da Zônula de Oclusão-1/metabolismo , Proteína da Zônula de Oclusão-1/genética , Ocludina/metabolismo , Ocludina/genética , Claudina-1/metabolismo , Claudina-1/genética , Impedância Elétrica , Regulação da Expressão Gênica
5.
Pflugers Arch ; 476(6): 993-1005, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38438679

RESUMO

Increase in transendothelial water permeability is an essential etiological factor in a variety of diseases like edema and shock. Despite the high clinical relevance, there has been no precise method to detect transendothelial water flow until now. The deuterium oxide (D2O) dilution method, already established for measuring transepithelial water transport, was used to precisely determine the transendothelial water permeability. It detected appropriate transendothelial water flow induced by different hydrostatic forces. This was shown in four different endothelial cell types. The general experimental setup was verified by gravimetry and absorbance spectroscopy. Determination of transendothelial electrical resistance (TEER) and immunocytochemical staining for proteins of the cell-cell contacts were performed to ensure that no damage to the endothelium occurred because of the measurements. Furthermore, endothelial barrier function was modulated. Measurement of transendothelial water flux was verified by measuring the TEER, the apparent permeability coefficient and the electrical capacity. The barrier-promoting substances cyclic adenosine monophosphate and iloprost reduced TEER and electrical capacity and increased permeability. This was accompanied by a reduced transendothelial water flux. In contrast, the barrier-damaging substances thrombin, histamine and bradykinin reduced TEER and electrical capacity, but increased permeability. Here, an increased water flow was shown. This newly established in vitro method for direct measurement of transendothelial water permeability was verified as a highly precise technique in various assays. The use of patient-specific endothelial cells enables individualized precision medicine in the context of basic edema research, for example regarding the development of barrier-protective pharmaceuticals.


Assuntos
Óxido de Deutério , Óxido de Deutério/metabolismo , Humanos , Impedância Elétrica , Água/metabolismo , Células Endoteliais/metabolismo , Células Endoteliais/efeitos dos fármacos , Permeabilidade , Animais , Endotélio Vascular/metabolismo , Endotélio Vascular/efeitos dos fármacos , Permeabilidade Capilar/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos
6.
J Neurophysiol ; 132(1): 308-315, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38865216

RESUMO

Neurophysiological recording with a new probe often yields better signal quality than with a used probe. Why does the signal quality degrade after only a few experiments? Here, we considered silicon probes in which the contacts are densely packed, and each contact is coated with a conductive polymer that increases its surface area. We tested 12 Cambridge Neurotech silicon probes during 61 recording sessions from the brain of three marmosets. Out of the box, each probe arrived with an electrodeposited polymer coating on 64 gold contacts and an impedance of around 50 kΩ. With repeated use, the impedance increased and there was a corresponding decrease in the number of well-isolated neurons. Imaging of the probes suggested that the reduction in signal quality was due to a gradual loss of the polymer coating. To rejuvenate the probes, we first stripped the contacts, completely removing their polymer coating, and then recoated them in a solution of 10 mM 3,4-Ethylenedioxythiophene (EDOT) monomer with 11 mM Poly(sodium 4-styrenesulfonate) (PSS) using a current density of about 3 mA/cm2 for 30 s. This recoating process not only returned probe impedance to around 50 kΩ but also yielded significantly improved signal quality during neurophysiological recordings. Thus, insertion into the brain promoted the loss of the polymer that coated the contacts of the silicon probes. This led to degradation of signal quality, but recoating rejuvenated the probes.NEW & NOTEWORTHY With repeated use, a silicon probe's ability to isolate neurons degrades. As a result, the probe is often discarded after only a handful of uses. Here, we demonstrate a major source of this problem and then produce a solution to rejuvenate the probes.


Assuntos
Callithrix , Neurônios , Silício , Animais , Silício/farmacologia , Neurônios/fisiologia , Neurônios/efeitos dos fármacos , Impedância Elétrica , Eletrodos Implantados , Encéfalo/fisiologia , Encéfalo/efeitos dos fármacos , Polímeros/farmacologia , Masculino , Neurofisiologia/instrumentação , Neurofisiologia/métodos , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Microeletrodos
7.
Am J Physiol Gastrointest Liver Physiol ; 327(1): G93-G104, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38772901

RESUMO

Few biomarkers support the diagnosis and treatment of disorders of gut-brain interaction (DGBI), although gastroduodenal junction (GDJ) electromechanical coupling is a target for novel interventions. Rhythmic "slow waves," generated by interstitial cells of Cajal (ICC), and myogenic "spikes" are bioelectrical mechanisms underpinning motility. In this study, simultaneous in vivo high-resolution electrophysiological and impedance planimetry measurements were paired with immunohistochemistry to elucidate GDJ electromechanical coupling. Following ethical approval, the GDJ of anaesthetized pigs (n = 12) was exposed. Anatomically specific, high-resolution electrode arrays (256 electrodes) were applied to the serosa. EndoFLIP catheters (16 electrodes; Medtronic, MN) were positioned luminally to estimate diameter. Postmortem tissue samples were stained with Masson's trichrome and Ano1 to quantify musculature and ICC. Electrical mapping captured slow waves (n = 512) and spikes (n = 1,071). Contractions paralleled electrical patterns. Localized slow waves and spikes preceded rhythmic contractions of the antrum and nonrhythmic contractions of the duodenum. Slow-wave and spike amplitudes were correlated in the antrum (r = 0.74, P < 0.001) and duodenum (r = 0.42, P < 0.001). Slow-wave and contractile amplitudes were correlated in the antrum (r = 0.48, P < 0.001) and duodenum (r = 0.35, P < 0.001). Distinct longitudinal and circular muscle layers of the antrum and duodenum had a total thickness of (2.8 ± 0.9) mm and (0.4 ± 0.1) mm, respectively. At the pylorus, muscle layers merged and thickened to (3.5 ± 1.6) mm. Pyloric myenteric ICC covered less area (1.5 ± 1.1%) compared with the antrum (4.2 ± 3.0%) and duodenum (5.3 ± 2.8%). Further characterization of electromechanical coupling and ICC biopsies may generate DGBI biomarkers.NEW & NOTEWORTHY This study applies electrical mapping, impedance planimetry, and histological techniques to the gastroduodenal junction to elucidate electromechanical coupling in vivo. Contractions of the terminal antrum and pyloric sphincter were associated with gastric slow waves. In the duodenum, bursts of spike activity triggered oscillating contractions. The relative sparsity of myenteric interstitial cells of Cajal in the pylorus, compared with the adjacent antrum and duodenum, is hypothesized to prevent coupling between antral and duodenal slow waves.


Assuntos
Duodeno , Motilidade Gastrointestinal , Células Intersticiais de Cajal , Animais , Duodeno/fisiologia , Duodeno/inervação , Células Intersticiais de Cajal/fisiologia , Suínos , Motilidade Gastrointestinal/fisiologia , Estômago/fisiologia , Estômago/inervação , Feminino , Contração Muscular/fisiologia , Impedância Elétrica , Músculo Liso/fisiologia
8.
Anal Chem ; 96(11): 4419-4429, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38448396

RESUMO

Impedance flow cytometry (IFC) has been demonstrated to be an efficient tool for label-free bacterial investigation to obtain the electrical properties in real time. However, the accurate differentiation of different species of bacteria by IFC technology remains a challenge owing to the insignificant differences in data. Here, we developed a convolutional neural networks (ConvNet) deep learning approach to enhance the accuracy and efficiency of the IFC toward distinguishing various species of bacteria. First, more than 1 million sets of impedance data (comprising 42 characteristic features for each set) of various groups of bacteria were trained by the ConvNet model. To improve the efficiency for data analysis, the Spearman correlation coefficient and the mean decrease accuracy of the random forest algorithm were introduced to eliminate feature interaction and extract the opacity of impedance related to the bacterial wall and membrane structure as the predominant features in bacterial differentiation. Moreover, the 25 optimized features were selected with differentiation accuracies of >96% for three groups of bacteria (bacilli, cocci, and vibrio) and >95% for two species of bacilli (Escherichia coli and Salmonella enteritidis), compared to machine learning algorithms (complex tree, linear discriminant, and K-nearest neighbor algorithms) with a maximum accuracy of 76.4%. Furthermore, bacterial differentiation was achieved on spiked samples of different species with different mixing ratios. The proposed ConvNet deep learning-assisted data analysis method of IFC exhibits advantages in analyzing a huge number of data sets with capacity for extracting predominant features within multicomponent information and will bring about progress and advances in the fields of both biosensing and data analysis.


Assuntos
Redes Neurais de Computação , Vibrio , Impedância Elétrica , Citometria de Fluxo , Algoritmos
9.
Anal Chem ; 96(28): 11299-11308, 2024 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-38953225

RESUMO

Measuring neuronal electrical activity, such as action potential propagation in cells, requires the sensitive detection of the weak electrical signal with high spatial and temporal resolution. None of the existing tools can fulfill this need. Recently, plasmonic-based electrochemical impedance microscopy (P-EIM) was demonstrated for the label-free mapping of the ignition and propagation of action potentials in neuron cells with subcellular resolution. However, limited by the signal-to-noise ratio in the high-speed P-EIM video, action potential mapping was achieved by averaging 90 cycles of signals. Such extensive averaging is not desired and may not always be feasible due to factors such as neuronal desensitization. In this study, we utilized advanced signal processing techniques to detect action potentials in P-EIM extracted signals with fewer averaged cycles. Matched filtering successfully detected action potential signals with as few as averaging five cycles of signals. Long short-term memory (LSTM) recurrent neural network achieved the best performance and was able to detect single-cycle stimulated action potential successfully [satisfactory area under the receiver operating characteristic curve (AUC) equal to 0.855]. Therefore, we show that deep learning-based signal processing can dramatically improve the usability of P-EIM mapping of neuronal electrical signals.


Assuntos
Potenciais de Ação , Aprendizado Profundo , Impedância Elétrica , Técnicas Eletroquímicas , Microscopia , Microscopia/métodos , Animais , Técnicas Eletroquímicas/métodos , Neurônios/fisiologia
10.
Anal Chem ; 96(42): 16946-16954, 2024 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-39387494

RESUMO

Microelectrodes have transformed our understanding of spatiotemporal responses to electrical stimulation. However, biological signals are often molecular, complicating the capture of intricate chemical signals. The microfluidic chip developed in this paper accurately measures droplet volume by using impedance analysis. The utilization of droplet volume as a feedback signal for precise microsampling pressure control ensures that microsampling remains unaffected by droplet volume influence. Once the microsampling is complete, chemiluminescence detection enables high temporal resolution and continuous and sensitive monitoring of chemical information within the droplets. Experimental verification shows that the chip can avoid volume influence through impedance feedback, achieving consistent and stable microampling at the nanoliter level (0-3 nL). In just 0.3 s, it can perform sensitive chemiluminescence detection of H2O2 and glucose within droplets. The linear detection ranges for these analytes are 10-50,000 and 20-600 µM, respectively, with the limit of detection being 0.648 and 0.334 µM. The significance of this chip lies in its ability to reveal changes in both electrical and chemical signals during transient biological processes. Its potential applications are numerous, encompassing a wide range of emerging areas such as single-cell analysis, cell communication, and cellular immunity.


Assuntos
Impedância Elétrica , Glucose , Peróxido de Hidrogênio , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Glucose/análise , Técnicas Analíticas Microfluídicas/instrumentação , Dispositivos Lab-On-A-Chip , Medições Luminescentes/métodos , Medições Luminescentes/instrumentação , Microeletrodos
11.
Am J Gastroenterol ; 119(4): 627-634, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37830520

RESUMO

INTRODUCTION: Among patients with chronic laryngeal symptoms, ambulatory reflux monitoring off acid suppression is recommended to evaluate for laryngopharyngeal reflux (LPR). However, reflux monitoring systems are diverse in configuration and monitoring capabilities, which present a challenge in creating a diagnostic reference standard in these patients. This study aimed to compare diagnostic yield and performance between reflux monitoring systems in patients with chronic laryngeal symptoms. METHODS: This multicenter, international study of adult patients referred for evaluation of LPR over a 5-year period (March 2018-May 2023) assessed and compared diagnostic yield of pathologic gastroesophageal reflux (GER+) on ambulatory reflux monitoring off acid suppression. RESULTS: Of 813 patients, 296 (36%) underwent prolonged wireless pH, 532 (65%) underwent 24-hour pH-impedance monitoring, and 15 (2%) underwent both tests. Overall diagnostic yield for GER+ was 36% and greater for prolonged wireless pH compared with that for 24-hour pH-impedance monitoring (50% vs 27%; P < 0.01). Among 15 patients who underwent both prolonged wireless pH and 24-h pH-impedance monitoring, concordance between systems for GER+ was 40%. The most common source of discordance was strong evidence of GER+ across multiple days on prolonged wireless pH compared with no evidence of GER+ on pH-impedance. DISCUSSION: In this multicenter international study of patients with chronic laryngeal symptoms referred for LPR evaluation, diagnostic yield of ambulatory reflux monitoring off acid suppression was 36% and rose to 50% when using wireless pH monitoring. In patients referred for chronic laryngeal symptoms, 24-hour pH-impedance monitoring may risk a low negative predictive value in patients with unproven GER+ disease.


Assuntos
Esofagite Péptica , Refluxo Laringofaríngeo , Adulto , Humanos , Refluxo Laringofaríngeo/diagnóstico , Monitorização Ambulatorial , Impedância Elétrica , Monitoramento do pH Esofágico , Concentração de Íons de Hidrogênio
12.
Am J Gastroenterol ; 119(1): 206-209, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37655704

RESUMO

INTRODUCTION: Gastroesophageal reflux disease (GERD) severity increases with esophageal body hypomotility, but the impact of Chicago Classification (CC) v4.0 criteria on GERD diagnosis is incompletely understood. METHODS: In patients with GERD evaluated with high-resolution manometry and pH-impedance monitoring, CCv3.0 and CCv4.0 diagnoses were compared. RESULTS: In 247 patients, hypomotility diagnosis decreased from 45.3% (CCv3.0) to 30.0% (CCv4.0, P < 0.001). In contrast, within patients with ineffective esophageal motility, proportions with pathological acid exposure increased from 38% (CCv3.0) to 88% (CCv4.0); baseline impedance and esophageal clearance demonstrated similar findings ( P < 0.05 for each comparison). DISCUSSION: CCv4.0 hypomotility criteria are more specific in supporting GERD evidence compared with CCv3.0.


Assuntos
Transtornos da Motilidade Esofágica , Refluxo Gastroesofágico , Humanos , Impedância Elétrica , Monitoramento do pH Esofágico , Refluxo Gastroesofágico/diagnóstico , Manometria , Concentração de Íons de Hidrogênio , Transtornos da Motilidade Esofágica/diagnóstico
13.
Am J Gastroenterol ; 119(1): 97-106, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37883488

RESUMO

INTRODUCTION: Guidelines advise esophageal motility testing for dysphagia when structural disorders are ruled out, but cost concerns impede adoption. We evaluated cost-effective positioning of esophageal motility testing in the algorithm to evaluate esophageal dysphagia. METHODS: We developed a decision analytic model comparing 3 strategies: (i) esophageal manometry, (ii) screening impedance planimetry followed by esophageal manometry if needed, or (iii) nonalgorithmic usual care. Diagnostic test accuracy was adapted to expected rates of esophageal motility disorders in general gastroenterology populations. We modeled routine testing for all patients with nonstructural/mechanical dysphagia compared with selective testing with strong suspicion for achalasia. Cost outcomes were defined on national commercial and Medicare datasets stratified on age and sex. Health outcomes were modeled on populations with achalasia. The time horizon was 1 year. RESULTS: Motility testing was preferred over nonalgorithmic usual care due to cost savings rather than health gains. To commercial insurers, routine esophageal manometry for nonstructural/mechanical dysphagia would be cost-saving below a reimbursed cost of $2,415. Screening impedance planimetry would be cost saving below a reimbursed cost of $1,130. The limit for reimbursed costs would be lower for patients older than 65 years to achieve cost savings mainly due to insurance. Sex did not significantly influence cost-effectiveness. Patients and insurers preferred routine screening impedance planimetry before manometry when the index of suspicion for achalasia was below 6%. DISCUSSION: Aligning with practice guidelines, routine esophageal motility testing seems cost saving to patients and insurers compared with nonalgorithmic usual care to evaluate nonstructural/mechanical dysphagia. Choice of testing should be guided by index of suspicion.


Assuntos
Transtornos de Deglutição , Acalasia Esofágica , Transtornos da Motilidade Esofágica , Estados Unidos , Humanos , Idoso , Transtornos de Deglutição/diagnóstico , Acalasia Esofágica/diagnóstico , Análise Custo-Benefício , Medicare , Transtornos da Motilidade Esofágica/diagnóstico , Manometria , Endoscopia Gastrointestinal , Impedância Elétrica
14.
Am J Gastroenterol ; 119(6): 1074-1080, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131629

RESUMO

INTRODUCTION: Gastric sleeve stenosis (GSS) is an increasingly common adverse event following sleeve gastrectomy for which objective diagnostic criteria are lacking. Impedance planimetry measurements show promise in characterizing GSS, though normal and abnormal benchmark values have never been established. METHODS: This was a retrospective analysis of upper endoscopies performed with impedance planimetry for suspected GSS. A bariatric endoscopist, blind to impedance planimetry measurements, assessed gastric sleeve anatomy and graded GSS severity. Impedance planimetry of diameter and distensibility index (DI) were obtained using 3 different balloon volumes (30, 40, and 50 mL). RESULTS: A total of 110 upper endoscopies were included. Distribution of GSS was graded as none, mild, moderate, and severe in 19 (17%), 27 (25%), 34 (31%), and 30 (27%) procedures, respectively. In normal gastric sleeve anatomy, mean (±SD) diameter and DI measurements using consecutive balloon volumes ranged from 19.1 (±5.5) to 23.2 (±1.7) and 16.8 (±4.9) to 23.1 (±10.9), respectively. In severe GSS, mean diameter and DI measurements ranged from 10.3 (±3.0) to 16.6 (±2.1) and 7.5 (±2.4) to 7.7 (±2.4), respectively. When stratified by severity, impedance planimetry measurements of diameter and DI were significantly lower with each subsequent increase in GSS grade regardless of balloon fill volumes ( P ≤ 0.001). DISCUSSION: Impedance planimetry measurements provide objective assessment in the diagnosis of GSS and correlate with luminal narrowing. A diameter ≥20 mm and a DI ≥15 mm 2 /mm Hg, as measured by impedance planimetry, are predictive of normal gastric sleeve anatomy. This study provides new benchmark values for the diagnosis and severity of GSS.


Assuntos
Benchmarking , Impedância Elétrica , Gastrectomia , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/diagnóstico , Índice de Gravidade de Doença , Complicações Pós-Operatórias/diagnóstico , Obesidade Mórbida
15.
Small ; 20(25): e2310221, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38396158

RESUMO

Porous substrate electroporation (PSEP) is a promising new method for intracellular delivery, yet fundamentals of PSEP are not well understood, especially the intermediate processes leading to delivery. PSEP is an electrical method, yet the relationship between PSEP and electrical impedance remains underexplored. In this study, a device capable of measuring impedance and performing PSEP is developed and the changes in transepithelial electrical impedance (TEEI) are monitored. These measurements show TEEI increases following PSEP, unlike other electroporation methods. The authors then demonstrate how cell culture conditions and electrical waveforms influence this response. More importantly, TEEI response features are correlated with viability and delivery efficiency, allowing prediction of outcomes without fluorescent cargo, imaging, or image processing. This label-free delivery also allows improved temporal resolution of transient processes following PSEP, which the authors expect will aid PSEP optimization for new cell types and cargos.


Assuntos
Impedância Elétrica , Eletroporação , Eletroporação/métodos , Porosidade , Animais , Humanos , Sobrevivência Celular
16.
Small ; 20(34): e2400797, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38618921

RESUMO

Visualization of training effectiveness is critical to patients' confidence and eventual rehabilitation. Here, an innovative magnetoinductive pressure sensor is proposed for monitoring hand rehabilitation in stroke hemiplegic patients. It couples the giant magneto and stress-impedance effects of a square spiral amorphous wire with the giant magnetoelastic effect of a polymer magnet (NdFeB@PDMS). The addition of the magnetoelastic layer results in a sensitivity improvement of 178%, a wide sensing range (up to 1 MPa), fast response/recovery times (40 ms), and excellent mechanical robustness (over 15 000 cycles). Further integration with an LC oscillation circuit enables frequency adjustment into the MHz range resulting in a sensitivity of 6.6% kPa-1 and outstanding linearity (R2 =  0.99717) over a stress range of up to 100 kPa. When attached to a commercial split-fingerboard, the sensor is capable of dynamically monitoring the force in each finger, providing a reading of the rehabilitation process. Unlike conventional inductive sensors, the sensor is based on an inductive force-responsive material (amorphous wire), which significantly boosts the sensitivity. The approach also demonstrates the potential of magnetoelasticity in static pressure sensing, which is highly sensitive to dynamic pressure only through electromagnetic induction. This makes it more suitable for long-term and continuous human health monitoring.


Assuntos
Mãos , Humanos , Mãos/fisiologia , Pressão , Elasticidade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Impedância Elétrica , Imãs
17.
Small ; 20(6): e2303352, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37794624

RESUMO

Antimicrobial resistance has become a serious threat to the global public health. Accurate and rapid antimicrobial susceptibility testing (AST) allows evidence-based prescribing of antibiotics to improve patient care and clinical outcomes. Current culture-based AST assays are inherently limited by the doubling time of bacterial reproduction, which require at least 24 h to have a decisive result. Herein, a label-free electrical impedance-based microfluidic platform designed to expedite and streamline AST procedure for clinical practice is presented. Following a 30-min exposure of bacterial samples to antibiotics, the presented high-throughput, single-bacterium level impedance characterization platform enables a rapid 2-min AST assay. The platform facilitates accurate analysis of individual bacterial viability, as indicated by changes in electrical characteristics, thereby enabling the determination of antimicrobial resistance. Moreover, the potential clinical applicability of this platform is demonstrated by testing different E. coli strains against five antibiotics, yielding 100% categorical agreements compared to standard culture methods.


Assuntos
Escherichia coli , Microfluídica , Humanos , Impedância Elétrica , Testes de Sensibilidade Microbiana , Antibacterianos/farmacologia , Bactérias
18.
Small ; 20(26): e2310700, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38483007

RESUMO

Single-cell mass spectrometry (MS) is significant in biochemical analysis and holds great potential in biomedical applications. Efficient sample preparation like sorting (i.e., separating target cells from the mixed population) and desalting (i.e., moving the cells off non-volatile salt solution) is urgently required in single-cell MS. However, traditional sample preparation methods suffer from complicated operation with various apparatus, or insufficient performance. Herein, a one-step sample preparation strategy by leveraging label-free impedance flow cytometry (IFC) based microfluidics is proposed. Specifically, the IFC framework to characterize and sort single-cells is adopted. Simultaneously with sorting, the target cell is transferred from the local high-salinity buffer to the MS-compatible solution. In this way, one-step sorting and desalting are achieved and the collected cells can be directly fed for MS analysis. A high sorting efficiency (>99%), cancer cell purity (≈87%), and desalting efficiency (>99%), and the whole workflow of impedance-based separation and MS analysis of normal cells (MCF-10A) and cancer cells (MDA-MB-468) are verified. As a standalone sample preparation module, the microfluidic chip is compatible with a variety of MS analysis methods, and envisioned to provide a new paradigm in efficient MS sample preparation, and further in multi-modal (i.e., electrical and metabolic) characterization of single-cells.


Assuntos
Impedância Elétrica , Citometria de Fluxo , Espectrometria de Massas , Microfluídica , Análise de Célula Única , Análise de Célula Única/métodos , Humanos , Citometria de Fluxo/métodos , Espectrometria de Massas/métodos , Microfluídica/métodos , Linhagem Celular Tumoral
19.
Int J Obes (Lond) ; 48(2): 209-217, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37891402

RESUMO

BACKGROUND: Visceral adipose tissue (VAT) has been linked to systemic proinflammatory characteristics, and measuring it accurately usually requires sophisticated instruments. This study aimed to estimate VAT applying a simpler method that uses total subcutaneous fat and total body fat (BF) measurements. METHOD: As part of our experimental approach, the subcutaneous fat mass (SFT) was measured via US (SFTtotal), and VAT was quantified by assessing MRI data. Both parameters were added to obtain total body fat (BFcalc). Those results were then compared to values obtained from a bioelectrical impedance analysis (BFBIA). Multiple regression analyses were employed to develop a simplified sex-specific equation for SFT, which was subsequently used in conjunction with BFBIA to determine VAT (VATEq). RESULT: We observed excellent reliability between BFBIA and BFcalc, with no significant difference in body fat values (20.98 ± 8.36 kg vs. 21.08 ± 8.81 kg, p = 0.798, ICC 0.948). VATEq_female/male revealed excellent reliability when compared to VATMRI, and no significant difference appeared (women: 0.03 ± 0.66 kg with a 95% CI ranging from -1.26 kg to 1.32 kg, p = 0.815, ICC: 0.955.; men: -0.01 ± 0.85 kg with a 95% CI ranging from -1.69 kg to 1.66 kg, p = 0.925, ICC: 0.952). CONCLUSION: Taking an experimental approach, VAT can be determined without MRI.


Assuntos
Tecido Adiposo , Gordura Intra-Abdominal , Humanos , Masculino , Feminino , Gordura Intra-Abdominal/diagnóstico por imagem , Impedância Elétrica , Reprodutibilidade dos Testes , Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
20.
Mol Hum Reprod ; 30(6)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38830032

RESUMO

Preterm birth is a serious pregnancy complication that affects neonatal mortality, morbidity, and long-term neurological prognosis. Predicting spontaneous preterm delivery (PTD) is important for its management. While excluding the risk of PTD is important, identifying women at high risk of PTD is imperative for medical intervention. Currently used PTD prediction parameters in clinical practice have shown high negative predictive values, but low positive predictive values. We focused on sulfated and sialylated glycocalyx changes in the uterus and vagina prior to the onset of parturition and explored the potential of electrophysiological detection of these changes as a PTD prediction parameter with a high positive predictive value. In vivo local vaginal bioelectrical impedance (VZ) was measured using two different mouse PTD models. PTD was induced in ICR mice through the subcutaneous injection of mifepristone or local intrauterine injection of lipopolysaccharide (LPS). The PTD rates were 100% and 60% post-administration of mifepristone (16-20 h, n = 4) and LPS (12-24 h, n = 20), respectively. The local VZ values (15 and 10 h after mifepristone or LPS treatment, respectively) were significantly lower in the PTD group than in the non-PTD group. Receiver operator characteristic (ROC) curve analysis of VZ at 125 kHz as a predictor of PTD showed an area under the ROC curve of 1.00 and 0.77 and positive predictive values of 1.00 and 0.86, for the mifepristone and LPS models, respectively, suggesting that local VZ value can predict PTD. Histological examination of the LPS-treated model 6 h post-treatment revealed increased expression of sulfomucins and/or sulfated proteoglycans and sialomucins in the cervical epithelium, cervical stroma and vaginal stroma. In conclusion, local VZ values can determine sulfated and sialylated glycocalyx alterations within the uterus and vagina and might be a useful PTD prediction parameter.


Assuntos
Impedância Elétrica , Camundongos Endogâmicos ICR , Nascimento Prematuro , Vagina , Animais , Feminino , Vagina/metabolismo , Vagina/efeitos dos fármacos , Vagina/patologia , Gravidez , Camundongos , Nascimento Prematuro/metabolismo , Nascimento Prematuro/diagnóstico , Mifepristona/farmacologia , Útero/metabolismo , Lipopolissacarídeos/farmacologia , Lipopolissacarídeos/toxicidade , Valor Preditivo dos Testes , Curva ROC , Modelos Animais de Doenças
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA