Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
BMC Cancer ; 19(1): 1189, 2019 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-31805884

RESUMO

BACKGROUND: Utilization of RNA sequencing methods to measure gene expression from archival formalin-fixed paraffin-embedded (FFPE) tumor samples in translational research and clinical trials requires reliable interpretation of the impact of pre-analytical variables on the data obtained, particularly the methods used to preserve samples and to purify RNA. METHODS: Matched tissue samples from 12 breast cancers were fresh frozen (FF) and preserved in RNAlater or fixed in formalin and processed as FFPE tissue. Total RNA was extracted and purified from FF samples using the Qiagen RNeasy kit, and in duplicate from FFPE tissue sections using three different kits (Norgen, Qiagen and Roche). All RNA samples underwent whole transcriptome RNA sequencing (wtRNAseq) and targeted RNA sequencing for 31 transcripts included in a signature of sensitivity to endocrine therapy. We assessed the effect of RNA extraction kit on the reliability of gene expression levels using linear mixed-effects model analysis, concordance correlation coefficient (CCC) and differential analysis. All protein-coding genes in the wtRNAseq and three gene expression signatures for breast cancer were assessed for concordance. RESULTS: Despite variable quality of the RNA extracted from FFPE samples by different kits, all had similar concordance of overall gene expression from wtRNAseq between matched FF and FFPE samples (median CCC 0.63-0.66) and between technical replicates (median expression difference 0.13-0.22). More than half of genes were differentially expressed between FF and FFPE, but with low fold change (median |LFC| 0.31-0.34). Two out of three breast cancer signatures studied were highly robust in all samples using any kit, whereas the third signature was similarly discordant irrespective of the kit used. The targeted RNAseq assay was concordant between FFPE and FF samples using any of the kits (CCC 0.91-0.96). CONCLUSIONS: The selection of kit to purify RNA from FFPE did not influence the overall quality of results from wtRNAseq, thus variable reproducibility of gene signatures probably relates to the reliability of individual gene selected and possibly to the algorithm. Targeted RNAseq showed promising performance for clinical deployment of quantitative assays in breast cancer from FFPE samples, although numerical scores were not identical to those from wtRNAseq and would require calibration.


Assuntos
Neoplasias da Mama/genética , Sequenciamento do Exoma/métodos , RNA/isolamento & purificação , Análise de Sequência de RNA/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Formaldeído , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Humanos , Pessoa de Meia-Idade , Inclusão em Parafina , RNA/normas , Fixação de Tecidos
2.
Exp Parasitol ; 200: 67-72, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30904695

RESUMO

Demodex is a type of parasitic mite which could cause serious dermatoses in 11 orders of mammals. However, due to the tiny body with thick chitin hard to be ruptured as well as the difficulty in obtaining a large number of mites, the quantity and quality of extracted RNA could hardly satisfied for transcriptome sequencing. This has hampered the research on functional genes and molecular pathogenesis of Demodex for a long time. To solve the problems above, the present study established a new RNA extraction method in combination Azanno method with liquid nitrogen grinding using 16 human and canine Demodex mite samples. The RNA quality detection results of Agilent 2100 Bioanalyzer showed that 8 of 16 RNA samples met the requirements for trace RNA-Seq, with RIN of 5.0-6.5 and RNA quantity of 1.1-16.0 ng. RNA quality was affected by grinding process and parasitic position of Demodex. Enough grinding number (≥2000) in moderate time (≤20 min) was significant for mites' complete rupture and RNA degradation prevention. D. brevis (100%, 3/3) parasitizing in human sebaceous glands had significantly higher RNA qualification rate than D. folliculorum (57.14%, 4/7) parasitizing in human hair follicles. Yet D. canis parasitizing in dog had lower RNA qualification rate (16.67%, 1/6) as mites were embedded in skin tissues and blood clots. It should be pointed out that microplate reader had defects with a lower RNA qualification rate of 6.25% (1/16) unmatched with 2100 Bioanalyzer, reminding that it could be only used as reference in RNA quality evaluation.


Assuntos
Ácaros/genética , RNA/isolamento & purificação , Transcriptoma , Animais , Cães , Folículo Piloso/parasitologia , Humanos , Ácaros/classificação , RNA/química , RNA/normas , RNA Ribossômico 18S/isolamento & purificação , Glândulas Sebáceas/parasitologia , Análise de Sequência de RNA , Trombose/parasitologia
3.
J Fish Biol ; 95(2): 393-400, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31017661

RESUMO

The partial cDNA sequences of eight reference genes (actb, tuba1, gapdh58, gapdh59, eef1a1, RNA 18 s, pabpc1, ube2I) were cloned from largemouth bass Micropterus salmoides. The expression levels of these eight genes were compared in the various tissues (eye, spleen, kidney, gill, muscle, brain, liver, heart, gut and gonad) of M. salmoides fed on forage fish. The results showed that the candidate genes exhibited tissue-specific expression to various degrees and the stability ranking order was eef1a1 > tuba1 > RNA 18 s > pabpc1 > ube2I > actb > gapdh58 > gapdh59 among tissue types. Four candidate genes eef1a1, tuba1, RNA 18 s and actb were used to analyse the stability in liver tissues of largemouth bass between the forage-fish group and the formulated-feed group. The candidate genes also showed some changes in expression levels in the livers, while eef1a1 and tuba1 had the most stable expression in livers of fish fed on alternative diets within 10 candidates. So eef1a1 and tuba1 were recommended as optimal reference gene in quantitative real-time PCR analysis to normalise the expression levels of target genes in tissues and lives of the M. salmoides fed on alternative diets. In livers, the expression levels of gck normalised by eef1a1 and tuba1 showed the significant up-regulation in formulated feed group (P < 0.05) than those in forage-fish group. While sex difference has no significant effects on the expression levels of gck in both groups.


Assuntos
Bass/genética , Dieta/veterinária , Animais , Bass/anatomia & histologia , Bass/fisiologia , DNA Complementar/biossíntese , DNA Complementar/química , Bases de Dados de Ácidos Nucleicos , Expressão Gênica , Instabilidade Genômica , Glucoquinase/genética , Fígado/metabolismo , RNA/análise , RNA/isolamento & purificação , RNA/normas , Reação em Cadeia da Polimerase em Tempo Real
4.
Anal Chem ; 90(18): 10865-10871, 2018 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-30109932

RESUMO

The accuracy and precision of quantification values of biomolecules, such as nucleic acids, are critical for the reliability of biomedical research and clinical examinations. To obtain an accurate quantitative value, it is necessary to use a measurement standard that has the same sequence and length as the target gene. The absence of an appropriate measurement standard leads to uncertain results. The development of a wide variety of different kinds of measurement standards, which have different sequences and lengths, is time-consuming and troublesome. We employed fluorescence correlation spectroscopy (FCS), which can be used to count the molecular number (absolute concentration) regardless of the molecular size and shape, without a standard curve. The confocal volume (i.e., the volume of excitation laser focus) of the FCS system was calibrated by measuring the primary standard of the fluorescent material. Furthermore, we investigated how to avoid artifacts originating from systematic aberrations or sample conditions. We validated the RNA concentration obtained from our FCS measurements using another primary standard RNA solution as a sample. Here, we describe an FCS calibration procedure with fluorescein solution standard reference material (SRM) 1932 as a primary standard and cross-validation of FCS values using RNA solutions certified reference material (CRM) 6204-a. The established method was applied to determine the concentrations of RNA samples that can be used as a laboratory working standards. The FCS method with a characterized SRM and CRM should serve as a universal method for absolute quantification of the number of biomolecules.


Assuntos
RNA/análise , Espectrometria de Fluorescência/métodos , Calibragem , Linhagem Celular , Confiabilidade dos Dados , Humanos , Limite de Detecção , RNA/normas , Reação em Cadeia da Polimerase em Tempo Real , Padrões de Referência , Reprodutibilidade dos Testes
5.
Anal Biochem ; 543: 128-131, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29247607

RESUMO

Adipose tissue is of interest in the context of its role in the pathogenesis of cardiovascular diseases. Modern experimental techniques require a well-purified RNA, but all the routine protocols for RNA extraction have a number of limitations in case of fatty tissues. Here we described a modified protocol for RNA extraction from human adipocytes based on routine column method. Suggested modifications optimized the sample preparation, lysis and washing lead to enhance RNA purity. We conclude that the current protocol for total RNA purification from adipocytes allows extracting a high-quality RNA devoid of fatty acids, organic solvents and salts contamination.


Assuntos
Adipócitos/química , RNA/isolamento & purificação , RNA/normas , Humanos , RNA/química , Software , Espectrofotometria
7.
BMC Biotechnol ; 16(1): 54, 2016 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-27342544

RESUMO

BACKGROUND: Highly multiplexed assays for quantitation of RNA transcripts are being used in many areas of biology and medicine. Using data generated by these transcriptomic assays requires measurement assurance with appropriate controls. Methods to prototype and evaluate multiple RNA controls were developed as part of the External RNA Controls Consortium (ERCC) assessment process. These approaches included a modified Latin square design to provide a broad dynamic range of relative abundance with known differences between four complex pools of ERCC RNA transcripts spiked into a human liver total RNA background. RESULTS: ERCC pools were analyzed on four different microarray platforms: Agilent 1- and 2-color, Illumina bead, and NIAID lab-made spotted microarrays; and two different second-generation sequencing platforms: the Life Technologies 5500xl and the Illumina HiSeq 2500. Individual ERCC controls were assessed for reproducible performance in signal response to concentration among the platforms. Most demonstrated linear behavior if they were not located near one of the extremes of the dynamic range. Performance issues with any individual ERCC transcript could be attributed to detection limitations, platform-specific target probe issues, or potential mixing errors. Collectively, these pools of spike-in RNA controls were evaluated for suitability as surrogates for endogenous transcripts to interrogate the performance of the RNA measurement process of each platform. The controls were useful for establishing the dynamic range of the assay, as well as delineating the useable region of that range where differential expression measurements, expressed as ratios, would be expected to be accurate. CONCLUSIONS: The modified Latin square design presented here uses a composite testing scheme for the evaluation of multiple performance characteristics: linear performance of individual controls, signal response within dynamic range pools of controls, and ratio detection between pairs of dynamic range pools. This compact design provides an economical sample format for the evaluation of multiple external RNA controls within a single experiment per platform. These results indicate that well-designed pools of RNA controls, spiked into samples, provide measurement assurance for endogenous gene expression studies.


Assuntos
Perfilação da Expressão Gênica/normas , Sequenciamento de Nucleotídeos em Larga Escala/normas , RNA/genética , RNA/normas , Análise de Sequência de RNA/normas , Algoritmos , Perfilação da Expressão Gênica/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Electrophoresis ; 36(17): 2072-81, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25998866

RESUMO

The analytical and clinical validity of analyses of RNA samples destined for clinical diagnosis and therapeutic management is directly impacted by RNA quality. RNA is affected by heat, enzymatic degradation, and Ultraviolet (UV) light. RNA from three eukaryotic cell lines was degraded by heat, RNase, or UV light. RNA integrity values obtained with the benchmark Agilent Bioanalyzer 2100 system were compared with those from the more recent QIAxcel Advanced system. The application of this novel method has allowed us to unravel differences between RNA biophysical and biochemical degradation modes. Agilent RNA integrity number (RIN) and QIAxcel RIS were comparable in heat-degraded and RNase III-degraded RNA. Agilent RIN and QIAxcel RIS were comparable at a RIN decision level of 7 in UV-degraded RNA but not overall. The QIAxcel RIS method was more precise than Agilent RIN for RIN<8, while the inverse was true for RIN≥8. Greater degradation of mRNA and rRNA in UV-damaged samples hampered the Agilent RIN calculation algorithm. Overall, RIS was more robust than RIN for assessing RNA integrity. The ΔΔCt-values for heat- and UV-degraded RNA samples showed slightly higher correlation with RIS than with RIN. RNA integrity can be used to categorize RNA samples for suitability for downstream gene expression analyses, independently of the RNA degradation mechanism. The new method QIAxcel is more robust and therefore allows more accurate categorization of compromised RNA samples.


Assuntos
RNA/análise , RNA/efeitos da radiação , Eletroforese Capilar , Células HeLa , Humanos , Células Jurkat , Controle de Qualidade , RNA/química , RNA/normas , Raios Ultravioleta
9.
Recent Results Cancer Res ; 199: 85-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25636432

RESUMO

The term "pre-analytics" summarizes all procedures concerned with specimen collection or processing as well as logistical aspects like transport or storage of tissue specimens. All or these variables as well as tissue-specific characteristics affect sample quality. While certain parameters like warm ischemia or tissue-specific characteristics cannot be changed, other parameters can be assessed and optimized. The aim of this study was to determine RNA quality by assessing the RIN values of specimens from different organs and to assess the influence of vacuum preservation. Samples from the GI tract, in general, appear to have lower RNA quality when compared to samples from other organ sites. This may be due to the digestive enzymes or bacterial colonization. Processing time in pathology does not significantly influence RNA quality. Tissue preservation with a vacuum sealer leads to preserved RNA quality over an extended period of time and offers a feasible alternative to minimize the influence of transport time into pathology.


Assuntos
Neoplasias Gastrointestinais/patologia , Trato Gastrointestinal/patologia , RNA/química , Manejo de Espécimes/normas , Bancos de Tecidos/normas , Fracionamento Celular/métodos , Fracionamento Celular/normas , Congelamento , Neoplasias Gastrointestinais/química , Trato Gastrointestinal/química , Alemanha , Humanos , Período Intraoperatório , Especificidade de Órgãos , Período Perioperatório , RNA/isolamento & purificação , RNA/normas , Estudos Retrospectivos , Manejo de Espécimes/métodos
10.
Mol Vis ; 20: 797-803, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24940035

RESUMO

PURPOSE: Attempts to determine the transcriptional profile of discrete subsets of limbal epithelial cells in situ using laser capture microdissection (LCM) face two major challenges. First, the transcriptional profile of cells within a tissue may rapidly change as the tissue is excised and exposed to cold ischemia. Second, there is a risk of degradation of the RNA as the cellular compartment is separated from the remaining tissue. An optimized protocol for LCM of corneal epithelium is presented to address these issues. METHODS: Experiments using porcine eye globes were carried out to determine both optimal procedures and settings for tissue harvest, transport, storage, histology, LCM, and RNA isolation. The optimized protocol was validated using human corneal epithelium. RESULTS: To facilitate preservation of the gene expression profile, we have developed a mechanical tool for dissection of cornea that, in combination with flash freezing, enables tissue to be stored within 5 min of enucleation of the eye. Furthermore, we describe how RNA from limbal crypt cells may be obtained using a procedure involving cryosectioning, histological staining, and LCM. CONCLUSION: In this paper, we describe an optimized method for isolating high-quality RNA from cellular subpopulations confined to the limbal crypts of the cornea. The procedure yields RNA in amounts and quality suitable for downstream gene expression analyses, such as microarrays or next generation sequencing.


Assuntos
Córnea/citologia , Córnea/metabolismo , Microdissecção e Captura a Laser/métodos , Microdissecção e Captura a Laser/normas , RNA/isolamento & purificação , RNA/normas , Animais , Desenho de Equipamento , Congelamento , Humanos , Controle de Qualidade , Sus scrofa
11.
Mol Vis ; 19: 1290-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23805035

RESUMO

PURPOSE: Profiling gene expression in human ocular tissues provides invaluable information for understanding ocular biology and investigating numerous ocular diseases. Accurate measurement of gene expression requires high-quality RNA, which often is a challenge with postmortem ocular tissues. METHODS: We examined the effect of various death to preservation (DP) times on the RNA quality of ten different ocular tissues. We used 16 eyes from eight different human donors. The eyes were preserved immediately in RNAlater or preserved after initial storage at 4 °C to create a range of DP times from 2 to 48 h. Ten ocular tissues were dissected from each eye. After total RNA was extracted from each dissected ocular tissue, the RNA integrity number (RIN) was determined using an Agilent Bioanalyzer. RESULTS: The RIN values from corneal and trabecular meshwork tissues were significantly (p<0.05) higher than those from the ciliary body at an earlier DP time (<6 h), but were not different among all tissues after 8 h. Interestingly, the RIN values from non-vascularized tissues were significantly (p=0.0002) higher than those from vascularized ocular tissues at early DP times (<6 h). The RIN value from the cornea was significantly (p<0.05) higher at short DP times compared to longer DP times. The RIN values from corneal tissues were significantly correlated to DP time according to regression analysis (p<0.05). CONCLUSIONS: In this study, we determined RNA quality from postmortem ocular tissues with various DP times. Our results emphasize the need for rapid preservation and processing of postmortem human donor eye tissues, especially for vascularized ocular tissues.


Assuntos
Olho/metabolismo , Mudanças Depois da Morte , RNA/normas , Feminino , Humanos , Masculino , Fatores de Tempo , Doadores de Tecidos , Preservação de Tecido
12.
Exp Parasitol ; 135(2): 257-61, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23850999

RESUMO

We evaluated the use of an RNA stabilisation buffer, RNAlater (Ambion, Austin, Texas), as a preservation medium for parasitic coprology analysis of faecal samples collected from chimpanzees living in the wild (Pan troglodytes troglodytes). Thirty faecal samples collected in the forests of south-east Cameroon (Mambele area) from 2003 to 2011 were preserved in RNAlater at -80 °C and analysed for their parasite content. We identified and counted parasitic elements and assessed their shape, size and morphology in relation to the storage time of the samples. We found that parasite elements were identifiable in RNAlater preserved samples after as many as 7 years, showing that RNAlater could be an effective and reliable preservation medium for coprology. Thus, its use could be an interesting way to optimise sample collection for several types of studies (parasitology and bacteriology/virology) at once, especially considering the logistically challenging and time-consuming field campaigns needed to obtain these faecal samples.


Assuntos
Doenças dos Símios Antropoides/parasitologia , Fezes/parasitologia , Pan troglodytes/parasitologia , Doenças Parasitárias em Animais/parasitologia , Preservação Biológica/métodos , Animais , Animais Selvagens , Soluções Tampão , Parasitos/classificação , Parasitos/genética , Parasitos/isolamento & purificação , RNA/normas
13.
Nucleic Acids Res ; 39(2): 578-88, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20864445

RESUMO

RNA-Seq has emerged as a revolutionary technology for transcriptome analysis. In this article, we report a systematic comparison of RNA-Seq and high-density exon array for detecting differential gene expression between closely related species. On a panel of human/chimpanzee/rhesus cerebellum RNA samples previously examined by the high-density human exon junction array (HJAY) and real-time qPCR, we generated 48.68 million RNA-Seq reads. Our results indicate that RNA-Seq has significantly improved gene coverage and increased sensitivity for differentially expressed genes compared with the high-density HJAY array. Meanwhile, we observed a systematic increase in the RNA-Seq error rate for lowly expressed genes. Specifically, between-species DEGs detected by array/qPCR but missed by RNA-Seq were characterized by relatively low expression levels, as indicated by lower RNA-Seq read counts, lower HJAY array expression indices and higher qPCR raw cycle threshold values. Furthermore, this issue was not unique to between-species comparisons of gene expression. In the RNA-Seq analysis of MicroArray Quality Control human reference RNA samples with extensive qPCR data, we also observed an increase in both the false-negative rate and the false-positive rate for lowly expressed genes. These findings have important implications for the design and data interpretation of RNA-Seq studies on gene expression differences between and within species.


Assuntos
Perfilação da Expressão Gênica/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Análise de Sequência de RNA/métodos , Animais , Cerebelo/metabolismo , Éxons , Perfilação da Expressão Gênica/normas , Humanos , Macaca mulatta , Análise de Sequência com Séries de Oligonucleotídeos/normas , Pan troglodytes/genética , Pan troglodytes/metabolismo , Reação em Cadeia da Polimerase , RNA/normas , Padrões de Referência , Análise de Sequência de RNA/normas
14.
Nucleic Acids Res ; 39(18): e124, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21745823

RESUMO

In quantitative single-cell studies, the critical part is the low amount of nucleic acids present and the resulting experimental variations. In addition biological data obtained from heterogeneous tissue are not reflecting the expression behaviour of every single-cell. These variations can be derived from natural biological variance or can be introduced externally. Both have negative effects on the quantification result. The aim of this study is to make quantitative single-cell studies more transparent and reliable in order to fulfil the MIQE guidelines at the single-cell level. The technical variability introduced by RT, pre-amplification, evaporation, biological material and qPCR itself was evaluated by using RNA or DNA standards. Secondly, the biological expression variances of GAPDH, TNFα, IL-1ß, TLR4 were measured by mRNA profiling experiment in single lymphocytes. The used quantification setup was sensitive enough to detect single standard copies and transcripts out of one solitary cell. Most variability was introduced by RT, followed by evaporation, and pre-amplification. The qPCR analysis and the biological matrix introduced only minor variability. Both conducted studies impressively demonstrate the heterogeneity of expression patterns in individual cells and showed clearly today's limitation in quantitative single-cell expression analysis.


Assuntos
Perfilação da Expressão Gênica/métodos , Análise de Célula Única/métodos , DNA/análise , DNA/normas , Feminino , Humanos , Linfócitos/metabolismo , Análise de Sequência com Séries de Oligonucleotídeos , RNA/análise , RNA/normas , RNA Mensageiro/análise , Reação em Cadeia da Polimerase em Tempo Real , Padrões de Referência , Reprodutibilidade dos Testes , Transcrição Reversa , Análise de Célula Única/normas , Fluxo de Trabalho
15.
BMC Genomics ; 13: 26, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22251372

RESUMO

BACKGROUND: Gene expression studies can be used to help identify disease-associated genes by comparing the levels of expressed transcripts between cases and controls, and to identify functional genetic variants (expression quantitative loci or eQTLs) by comparing expression levels between individuals with different genotypes. While many of these studies are performed in blood or lymphoblastoid cell lines due to tissue accessibility, the relevance of expression differences in tissues that are not the primary site of disease is unclear. Further, many eQTLs are tissue specific. Thus, there is a clear and compelling need to conduct gene expression studies in tissues that are specifically relevant to the disease of interest. One major technical concern about using autopsy-derived tissue is how representative it is of physiologic conditions, given the effect of postmortem interval on tissue degradation. RESULTS: In this study, we monitored the gene expression of 13 tissue samples harvested from a rapid autopsy heart (non-failed heart) and 7 from a cardiac explant (failed heart) through 24 hours of autolysis. The 24 hour autopsy simulation was designed to reflect a typical autopsy scenario where a body may begin cooling to ambient temperature for ~12 hours, before transportation and storage in a refrigerated room in a morgue. In addition, we also simulated a scenario wherein the body was left at room temperature for up to 24 hours before being found. A small fraction (< 2.5%) of genes showed fluctuations in expression over the 24 hr period and largely belong to immune and signal response and energy metabolism-related processes. Global expression analysis suggests that RNA expression is reproducible over 24 hours of autolysis with 95% genes showing < 1.2 fold change. Comparing the rapid autopsy to the failed heart identified 480 differentially expressed genes, including several types of collagens, lumican (LUM), natriuretic peptide A (NPPA) and connective tissue growth factor (CTGF), which allows for the clear separation between failing and non-failing heart based on gene expression profiles. CONCLUSIONS: Our results demonstrate that RNA from autopsy-derived tissue, even up to 24 hours of autolysis, can be used to identify biologically relevant expression pattern differences, thus serving as a practical source for gene expression experiments.


Assuntos
Perfilação da Expressão Gênica , Miocárdio/metabolismo , Autopsia , Análise por Conglomerados , Regulação da Expressão Gênica , Insuficiência Cardíaca/genética , Humanos , Anotação de Sequência Molecular , Miocárdio/patologia , RNA/normas , Estabilidade de RNA , Curva ROC , Reprodutibilidade dos Testes , Fatores de Tempo
16.
Exp Mol Pathol ; 92(1): 33-43, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21963600

RESUMO

Although the extraction and analysis of nucleic acids from formalin-fixed paraffin-embedded tissues is a routine and growing part of pathology practice, no generally accepted recommendations exist to guide laboratories in their selection of tissue fixation, processing and DNA/RNA extraction techniques. The aim of this study was to determine how fixation method and length, paraffin embedding, processing conditions and nucleic acid extraction methods affect quality and quantity of DNA and RNA, and their performance in downstream applications. Nine tissue samples were subjected to freezing, fixation in formalin for <24 h and 7 days followed by conventional processing, and fixation in molecular fixative for <24 h and 7 days followed by rapid processing. DNA and RNA were isolated using in-house extraction and commercial kits, and assessed by PCR reactions for amplicons with varying sizes ranging from 268 to 1327 bp and one-step RT-PCR for 621 bp and 816 bp amplicons of housekeeping genes. Molecular fixative (MF) appeared to perform well under nearly all circumstances (extraction methods, fixation lengths and longer amplicons), often performing as well as frozen samples. Formalin fixation generally performed well only for shorter length amplicons and short fixation (<24 h). WaxFree kit showed consistently higher success rates for DNA and poorer rates for RNA. RecoverAll kit generally performed suboptimally in combination with prolonged formalin fixation. In conclusion, the Molecular Fixative regardless of fixation length, and the rapid tissue processing system were able to preserve large DNA and RNA fragments in paraffin blocks, making these techniques preferable for use in downstream molecular diagnostic assays.


Assuntos
DNA/isolamento & purificação , Fixadores/normas , Patologia Molecular/normas , RNA/isolamento & purificação , Fixação de Tecidos/métodos , Colo/química , DNA/análise , DNA/normas , Feminino , Formaldeído/normas , Humanos , Fígado/química , Miométrio/química , Inclusão em Parafina , Patologia Molecular/métodos , Reação em Cadeia da Polimerase , RNA/análise , RNA/normas , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fatores de Tempo
17.
Mol Biol Rep ; 39(5): 5841-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22203483

RESUMO

Quantitative real time reverse transcriptase polymerase chain reaction (RT-qPCR) is preferred for gene expression analysis in living organisms. Currently, it is a valuable tool for biological and ecological studies as it provides a relatively straightforward way to assess the relevance of transcriptional regulation under developmental and stress tolerance conditions. However, studies have shown that some commonly used reference genes varied among different experimental treatments, thus, systematic evaluation of reference genes is critical for gene expression profiling, which is often neglected in gene expression studies of arthropods. The aim of this study is to identify the suitable reference genes for RT-qPCR experiments involving various developmental stages and/or under abiotic stresses in citrus red mite Panonychus citri, a key pest in citrus orchards worldwide. GeNorm, NormFinder, and Bestkeeper software analysis indicates that elongation factor-1 alpha (ELF1A), RNA polymerase II largest subunit, alpha tublin, and glyceraldhyde-3-phosphate dehydrogenase (GAPDH) are the most stable reference genes in various developmental stages, meanwhile, ELF1A and GAPDH were the most stable reference genes under various abiotic stresses. Furthermore, this study will serve as a resource to screen reference genes for gene expression studies in any other spider mite species.


Assuntos
Genes/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Estresse Fisiológico/genética , Tetranychidae/crescimento & desenvolvimento , Tetranychidae/genética , Animais , Primers do DNA/metabolismo , Perfilação da Expressão Gênica , Regulação da Expressão Gênica no Desenvolvimento , Estudos de Associação Genética , RNA/genética , RNA/normas , Padrões de Referência , Software
18.
Indian J Pathol Microbiol ; 65(1): 105-110, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35074973

RESUMO

INTRODUCTION: Optimal DNA and RNA quantity and purity is essential for downstream molecular biology experimentation and to avoid re-processing of sample. Despite availability of different kits and automated systems for nucleic acid isolation there is limited data on their performance evaluation, more so with pediatric blood samples, that are usually compromised in quantity. Hence, we evaluated the performance of automated QIAcube platform using pediatric blood samples in parallel with manual Qiagen extraction kits. MATERIALS AND METHODS: : A total of 500 samples were analyzed based on groups of PBMC and direct blood input. The isolated DNA and RNA were surveyed for quantity and quality tests by spectrophotometric and downstream analysis. RESULTS: : There was no significant difference in the DNA quantity (ng/ul) between manual and automated method based on similar sample input but quality (260/280) was significantly better with the QIAcube platform when direct blood and or PBMCs were used for extraction respectively (1.82 ± 004 Vs. 1.84.002; P-0.000008 and 1.859 ± 005 Vs. 1.843 ± 0.003; P-0.02). Moreover, the standard error mean was low for both quantity and quality in the QIAcube method suggesting uniformity. Comparison of quality assessment by spectrophotometer and qubit fluorimeter showed that QIAcube sheared DNA less (P- 0.038) as compared to manual method (P-0.013). Also, time taken to process the samples in QIAcube was 23% less than the kit-based method. CONCLUSION: Overall analysis of QIAcube platform suggests that it yields more better, uniform, and less-sheared quality of nucleic acid in a relatively less time as compared to manual extraction kits.


Assuntos
Automação Laboratorial/normas , Células Sanguíneas , DNA/isolamento & purificação , Leucócitos Mononucleares , Biologia Molecular/métodos , RNA/isolamento & purificação , Kit de Reagentes para Diagnóstico/normas , Automação Laboratorial/métodos , Criança , Pré-Escolar , DNA/normas , Humanos , Lactente , Biologia Molecular/instrumentação , Biologia Molecular/normas , RNA/normas
19.
J Transl Med ; 9: 121, 2011 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-21791045

RESUMO

BACKGROUND: RNA quality is believed to decrease with ischaemia time, and therefore open radical prostatectomy has been advantageous in allowing the retrieval of the prostate immediately after its devascularization. In contrast, robotic-assisted laparoscopic radical prostatectomies (RALP) require the completion of several operative steps before the devascularized prostate can be extirpated, casting doubt on the validity of this technique as a source for obtaining prostatic tissue. We seek to establish the integrity of our biobanking process by measuring the RNA quality of specimens derived from robotic-assisted laparoscopic radical prostatectomy. METHODS: We describe our biobanking process and report the RNA quality of prostate specimens using advanced electrophoretic techniques (RNA Integrity Numbers, RIN). Using multivariate regression analysis we consider the impact of various clinicopathological correlates on RNA integrity. RESULTS: Our biobanking process has been used to acquire 1709 prostates, and allows us to retain approximately 40% of the prostate specimen, without compromising the histopathological evaluation of patients. We collected 186 samples from 142 biobanked prostates, and demonstrated a mean RIN of 7.25 (standard deviation 1.64) in 139 non-stromal samples, 73% of which had a RIN ≥ 7. Multivariate regression analysis revealed cell type--stromal/epithelial and benign/malignant--and prostate volume to be significant predictors of RIN, with unstandardized coefficients of 0.867(p = 0.001), 1.738(p < 0.001) and -0.690(p = 0.009) respectively. A mean warm ischaemia time of 120 min (standard deviation 30 min) was recorded, but multivariate regression analysis did not demonstrate a relationship with RIN within the timeframe of the RALP procedure. CONCLUSIONS: We demonstrate the robustness of our protocol--representing the concerted efforts of dedicated urology and pathology departments--in generating RNA of sufficient concentration and quality, without compromising the histopathological evaluation and diagnosis of patients. The ischaemia time associated with our prostatectomy technique using a robotic platform does not negatively impact on biobanking for RNA studies.


Assuntos
Bancos de Espécimes Biológicos/normas , Próstata/metabolismo , Prostatectomia/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , RNA/genética , RNA/normas , Robótica , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Próstata/patologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
20.
Anal Biochem ; 415(2): 151-7, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21530480

RESUMO

A large part of the reliability of reverse transcription quantitative polymerase chain reaction (RT-qPCR) data depends on technical variations. Such variations are mainly attributable to the reverse transcription step. Standardization is a key factor in decreasing the intersample variability. However, an ideal standardization is not always possible, and compromises must be found. Due to technical requirements, the current consensus is that a constant amount of total RNA should be used for the RT step (CA-RT). Because RNA isolation yields are variable, such a practice requires the use of variable volumes of nucleic acid extracts in RT reaction. We demonstrate that some RNA extracts contain both exogenous and endogenous inhibitors. These inhibitors induce a decrease in RT efficiency that significantly impairs the reliability of RT-qPCR data. Conversely, these inhibitors have a slight effect on the qPCR step. To overcome such drawbacks, we proposed to carry out the RT reaction with a constant volume of RNA extract by preserving a constant RNA amount through the supplementation of yeast transfer RNA (CV-RT). We show that CV-RT, compared with the usual CA-RT, allows us to decrease the RT-qPCR variability induced by intersample differences. Such a decrease is a prerequisite for the reliability of messenger RNA quantification.


Assuntos
RNA Mensageiro/análise , DNA Polimerase Dirigida por RNA/química , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , RNA/análise , RNA/antagonistas & inibidores , RNA/normas , RNA Mensageiro/normas , RNA de Transferência/química , DNA Polimerase Dirigida por RNA/metabolismo , Inibidores da Transcriptase Reversa/química , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA