Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68.880
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(50): e2213157119, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36490316

RESUMO

The formation of toxic Amyloid ß-peptide (Aß) oligomers is one of the earliest events in the molecular pathology of Alzheimer's Disease (AD). These oligomers lead to a variety of downstream effects, including impaired neuronal signaling, neuroinflammation, tau phosphorylation, and neurodegeneration, and it is estimated that these events begin 10 to 20 y before the presentation of symptoms. Toxic Aß oligomers contain a nonstandard protein structure, termed α-sheet, and designed α-sheet peptides target this main-chain structure in toxic oligomers independent of sequence. Here we show that a designed α-sheet peptide inhibits the deleterious effects on neuronal signaling and also serves as a capture agent in our soluble oligomer binding assay (SOBA). Pre-incubated synthetic α-sheet-containing Aß oligomers produce strong SOBA signals, while monomeric and ß-sheet protofibrillar Aß do not. α-sheet containing oligomers were also present in cerebrospinal fluid (CSF) from an AD patient versus a noncognitively impaired control. For the detection of toxic oligomers in plasma, we developed a plate coating to increase the density of the capture peptide. The proof of concept was achieved by testing 379 banked human plasma samples. SOBA detected Aß oligomers in patients on the AD continuum, including controls who later progressed to mild cognitive impairment. In addition, SOBA discriminated AD from other forms of dementia, yielding sensitivity and specificity of 99% relative to clinical and neuropathological diagnoses. To explore the broader potential of SOBA, we adapted the assay for a-synuclein oligomers and confirmed their presence in CSF from patients with Parkinson's disease and Lewy body dementia.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/sangue , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/sangue , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Peptídeos beta-Amiloides/metabolismo , Doença de Parkinson/sangue , Doença de Parkinson/líquido cefalorraquidiano , Doença de Parkinson/metabolismo , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/líquido cefalorraquidiano , Fragmentos de Peptídeos/metabolismo , Líquido Cefalorraquidiano/química , Doença por Corpos de Lewy/sangue , Doença por Corpos de Lewy/líquido cefalorraquidiano , Doença por Corpos de Lewy/metabolismo , Técnicas Imunoenzimáticas/métodos
2.
J Clin Microbiol ; 62(1): e0121323, 2024 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-38099670

RESUMO

Histoplasma and Blastomyces antigen detection assays are commonly used diagnostic tools. However, a high level of cross-reactivity between these antigens prevents definitive pathogen identification by these assays alone. Retrospective analysis of 3,529 patients with Histoplasma and Blastomyces antigen testing performed on the same serum sample yielded an overall percent agreement of 99.3% (3,506 of 3,529; kappa: 0.859) between the two assays, suggesting that use of a single assay to detect both antigens may be an alternative diagnostic approach. We assessed performance of the Gotham BioTech Blastomyces antigen (GBA) enzyme immunoassay (EIA) (Portland, Maine) for detection of Blastomyces and Histoplasma antigens in serum. Comparison to the MiraVista Diagnostics Blastomyces (MVB) EIA showed 100% positive (24 of 24), negative (57 of 57), and overall (81 of 81) percent agreement. Additionally, 171 sera were used to compare the GBA EIA to the MiraVista Diagnostics Histoplasma (MVH) EIA, which showed 91.3% (63 of 69), 98% (100 of 102), and 95.3% (163 of 171) positive, negative, and overall percent agreement, respectively. Among eight patients with discordant GBA/MVH EIA results, seven had additional fungal testing performed, and results suggested that the MVH and GBA results were inaccurate for two and five samples, respectively. Overall, this study suggests that the GBA EIA has a high level of agreement with both of the commonly used, individual Blastomyces and Histoplasma antigen EIAs. By taking advantage of the high level of cross-reactivity between Blastomyces and Histoplasma antigen EIAs, utilization of a single antigen detection assay for these fungi provides an opportunity to optimize test utilization and decrease patient cost while maintaining a high level of diagnostic accuracy.


Assuntos
Blastomyces , Histoplasma , Humanos , Estudos Retrospectivos , Antígenos de Fungos , Técnicas Imunoenzimáticas
3.
Med Mycol ; 62(4)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38479779

RESUMO

Definitive diagnosis of histoplasmosis relies on culture and/or cytology/histopathology; however, these procedures have limited sensitivity and cultures are time-consuming. Antibodies detection by immunodiffusion has low sensitivity in immunocompromised individuals and uses histoplasmin (HMN), a crude antigenic extract, as reagent. Novel protein antigen candidates have been recently identified and produced by DNA-recombinant techniques to obtain standardized and specific reagents for diagnosing histoplasmosis. To compare the analytical performance of novel enzyme-linked immunosorbent assays (ELISAs) for antibodies testing for diagnosing histoplasmosis using different Histoplasma capsulatum antigens as reagents. The H. capsulatum 100 kDa protein (Hcp100), the M antigen and its immunoreactive fragment F1 were produced by DNA-recombinant techniques. Galactomannan was purified from both the yeast and mycelial cell walls (yGM and mGM, respectively). The analytical performance of the ELISA tests for the serological detection of antibodies against these antigens was evaluated and compared with those obtained using HMN as reagent. Antibodies detection by the Hcp100 ELISA demonstrated 90.0% sensitivity and 92.0% specificity, versus 43.3% sensitivity and 95.0% specificity of the M ELISA, 33.3% sensitivity and 84.0% specificity of the F1 ELISA, 96.7% sensitivity and 94.0% specificity of the yGM ELISA, 83.3% sensitivity and 88.0% specificity of the mGM ELISA, and 70.0% sensitivity and 86.0% specificity for the HMN ELISA. In summary, Hcp100 is proposed as the most promising candidate for the serodiagnosis of histoplasmosis. The primary immunoreactive element in HMN proved to be GM rather than the M antigen. Nevertheless, a higher incidence of cross-reactions was noted with GM compared to M.


Hcp100 is a promising serodiagnostic candidate for histoplasmosis, boasting high sensitivity and specificity. Notably, GM, rather than M antigen, emerged as the primary immunoreactive element in HMN, despite a higher incidence of cross-reactions with GM compared to M.


Assuntos
Histoplasmose , Humanos , Histoplasmose/diagnóstico , Histoplasmose/veterinária , Histoplasma/genética , Anticorpos Antifúngicos , Técnicas Imunoenzimáticas , Antígenos de Fungos , Anticorpos , Imunodifusão/veterinária , Saccharomyces cerevisiae , DNA
4.
Ann Clin Microbiol Antimicrob ; 23(1): 35, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664689

RESUMO

PURPOSE: The clinical significance of negative toxin enzyme immunoassays (EIA) for Clostridioides difficile infections (CDIs) is unclear. Our study aimed to investigate the significance of toxin EIA-negative in the diagnosis and prognosis of CDI. METHODS: All stool specimens submitted for C. difficile toxin EIA testing were cultured to isolate C. difficile. In-house PCR for tcdA, tcdB, cdtA, and cdtB genes were performed using C. difficile isolates. Stool specimens were tested with C. difficile toxins A and B using EIA kit (RIDASCREEN Clostridium difficile toxin A/B, R-Biopharm AG, Darmstadt, Germany). Characteristics and subsequent CDI episodes of toxin EIA-negative and -positive patients were compared. RESULTS: Among 190 C. difficile PCR-positive patients, 83 (43.7%) were toxin EIA-negative. Multivariate analysis revealed independent associations toxin EIA-negative results and shorter hospital stays (OR = 0.98, 95% CI 0.96-0.99, p = 0.013) and less high-risk antibiotic exposure in the preceding month (OR = 0.38, 95% CI 0.16-0.94, p = 0.035). Toxin EIA-negative patients displayed a significantly lower white blood cell count rate (11.0 vs. 35.4%, p < 0.001). Among the 54 patients who were toxin EIA-negative and did not receive CDI treatment, three (5.6%) were diagnosed with CDI after 7-21 days without complication. CONCLUSION: Our study demonstrates that toxin EIA-negative patients had milder laboratory findings and no complications, despite not receiving treatment. Prolonged hospitalisation and exposure to high-risk antibiotics could potentially serve as markers for the development of toxin EIA-positive CDI.


Assuntos
Proteínas de Bactérias , Toxinas Bacterianas , Clostridioides difficile , Infecções por Clostridium , Fezes , Humanos , Clostridioides difficile/genética , Fezes/microbiologia , Masculino , Feminino , Toxinas Bacterianas/análise , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/tratamento farmacológico , Infecções por Clostridium/microbiologia , Idoso , Pessoa de Meia-Idade , Proteínas de Bactérias/genética , Proteínas de Bactérias/análise , Enterotoxinas/análise , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Técnicas Imunoenzimáticas , Adulto , Resultado do Tratamento , Reação em Cadeia da Polimerase , Prognóstico
5.
Gen Comp Endocrinol ; 345: 114386, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37748527

RESUMO

Androgens and estrogens are steroid hormones that regulate reproductive processes in both males and females. Monitoring plasma levels of these steroids or their metabolites present in feces, offers diagnostic support for assessing the reproductive status of animals. Immunoassays are commonly used methods for quantifying these hormones, but their protocols require species-specific validation to ensure reliability. The objective of this study was to perform analytically and biologically validation of enzyme immunoassay (EIA) kits for measuring testosterone (T), estradiol (E2), faecal androgen metabolites (fAM), and faecal estrogenic metabolites (fEM) in the tropical screech owl (Megascops choliba). Serum and fecal samples were collected from six adult females and six males both before and during breeding season, with males' gonadal activity assessed using electroejaculation (EE). The parallelism test confirmed the immunogenic similarity of the antigens in the estradiol and testosterone standards and the antigens in the serum samples and fecal extracts of M. choliba. Additionally, the EIA kits displayed nearly 100% recovery rates, and showed coefficients of variation ranging from 8% to 14% at the intra-assay level and from 10% to 16% at the inter-assay level, underscoring result reliability and consistency. In males, the highest serum T and fAM levels were recorded concurrently with the presence of spermatozoa in samples collected via EE. Although females did not exhibit oviposition events, significantly higher E2 and fEM levels were observed in August compared to May, suggesting potential seasonal variations in estrogenic hormone production. Fecal androgen and estrogen levels were significantly different between sexes in August, with males having higher fAM and females having higher fEM levels. Overall, the immunoassays validated in this study were found to be efficient in diagnosing reproductive activity in owls.


Assuntos
Estradiol , Hormônios Esteroides Gonadais , Estrigiformes , Testosterona , Animais , Feminino , Masculino , Androgênios , Estradiol/metabolismo , Estrogênios , Estrona , Fezes , Hormônios Esteroides Gonadais/metabolismo , Técnicas Imunoenzimáticas , Reprodutibilidade dos Testes , Testosterona/metabolismo
6.
Endocr J ; 71(5): 461-469, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38417879

RESUMO

Plasma aldosterone concentration (PAC) was routinely measured using radioimmunoassay (RIA); however, the RIA kit was discontinued in March 2021 in Japan. This study examined PAC conversion in adrenal venous sampling (AVS) and AVS criteria when measured using chemiluminescent enzyme immunoassay (CLEIA). PAC of 415 adrenal venous blood samples from AVS (including segmental AVS) of 63 patients with primary aldosteronism was measured using RIA (Spac-S aldosterone kit; Fujirebio Inc.) and CLEIA (Lumipulse Presto Aldosterone; Fujirebio Inc.). PAC of 70 AVS samples was also measured using liquid chromatography-mass spectrometry (LC-MS/MS, ASKA Pharma Medical Co., Ltd.). PAC conversion formulas were determined for each AVS sample assay. PAC measured using CLEIA was significantly correlated with that measured using RIA (correlation coefficient = 0.971). The PAC conversion formula was PAC (CLEIA) = PAC (RIA) × 0.772 - 1,199 pg/mL. The PAC of 14,000 pg/mL in RIA was equivalent to 9,613 pg/mL in CLEIA. PAC measured using CLEIA was also correlated with that measured using LC-MS/MS, and the PAC conversion formula was PAC (CLEIA, pg/mL) = 0.97 × PAC (LC-MS/MS, pg/mL) + 211. The inter-assay coefficient of variability (CV) was 1.1-1.3% and intra-assay CV was 1.0-1.7%, measured using CLEIA. The PAC conversion formula for AVS samples was obtained using CLEIA and RIA, and the conversion formula was different from that for peripheral blood. PAC values measured by CLEIA showed preferable accuracy and high concordance with those measured by LC-MS/MS, even in AVS samples. The study outcomes are useful for interpreting AVS results using non-RIA measurement methods.


Assuntos
Aldosterona , Hiperaldosteronismo , Técnicas Imunoenzimáticas , Radioimunoensaio , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangue , Radioimunoensaio/métodos , Radioimunoensaio/normas , Feminino , Aldosterona/sangue , Masculino , Pessoa de Meia-Idade , Técnicas Imunoenzimáticas/métodos , Glândulas Suprarrenais/irrigação sanguínea , Adulto , Medições Luminescentes/métodos , Idoso , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Coleta de Amostras Sanguíneas/métodos , Japão
7.
Mycoses ; 67(6): e13756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38886163

RESUMO

BACKGROUND: Serum galactomannan (GM) testing is essential for diagnosing invasive aspergillosis (IA), particularly in immunocompromised individuals. The global lack of on-site GM testing capacities necessitates cost-effective alternatives, such as .the clarus Aspergillus GM enzyme immunoassay prototype (clarus AGM prototype). METHODS: This single-centre, cross-sectional study compared the diagnostic performance of the clarus AGM prototype (IMMY, Norman, Oklahoma) with the serological gold standard (=Platelia AGM assay; Bio-Rad, Marnes-la-Cocquette, France). IA was classified according to modified 2020 EORTC/MSG consensus and 2024 FUNDICU criteria. In total, 300 prospectively (May-Dec 2023) and retrospectively (2012-2015) collected samples were included. RESULTS: Among 300 samples from 232 patients, 49 (16%) were classified as proven (n = 1) or probable IA (n = 48). In non-IA cases (n = 250), one patient was classified as possible IA. With the manufacturer recommended cut-off of ≥0.2, sensitivity and specificity of the clarus AGM prototype were 27% (13/49; 95% confidence interval [CI]: 15%-41%) and 99% (248/250; 95% CI: 97%-100%), respectively, while sensitivity and specificity were 78% and 79% when using the optimised Youden's cut-off of 0.0045 ODI. ROC curve analysis demonstrated an area under the curve (AUC) of 0.829 (95% CI: 0.760-0.898) for the clarus AGM prototype in distinguishing between proven/probable IA and non-IA. The AUC for the Platelia AGM was 0.951 (95% CI: 0.909-994). Spearman's correlation analysis showed a weak correlation between the two assays (0.382; p < .001). CONCLUSIONS: The weak correlation between the clarus AGM prototype and Platelia AGM highlights the need for further investigation into the clinical performance of the clarus AGM prototype, giving the different antigen epitopes addressed.


Assuntos
Aspergillus , Galactose , Técnicas Imunoenzimáticas , Aspergilose Pulmonar Invasiva , Mananas , Sensibilidade e Especificidade , Humanos , Mananas/sangue , Galactose/análogos & derivados , Aspergilose Pulmonar Invasiva/diagnóstico , Técnicas Imunoenzimáticas/métodos , Estudos Transversais , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Estudos Retrospectivos , Aspergillus/isolamento & purificação , Aspergillus/imunologia , Adulto , Estudos Prospectivos , Antígenos de Fungos/sangue , Idoso de 80 Anos ou mais , Adulto Jovem , Curva ROC
8.
J Clin Microbiol ; 61(12): e0071023, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38038482

RESUMO

The emergence of Rocahepevirus ratti [species HEV ratti (r HEV)] as a causative agent of hepatitis E in humans presents a new potential threat to global public health. The R. ratti genotype 1 (r-1 HEV) variant only shares 50%-60% genomic identity with Paslahepevirus balayani [species HEV balayani (b HEV)] variants, which are the main causes of hepatitis E infection in humans. Here, we report antigen diagnoses for r-1 HEV and b HEV using an enzymatic immunoassay (EIA) method. We detected recombinant virus-like particles protein (HEV 239) of r HEV and b HEV using a collection of hepatitis E virus (HEV)-specific monoclonal antibodies. Two optimal candidates, the capture antibody P#1-H4 and the detection antibodies C145 (P#1-H4*/C145#) and C158 (P#1-H4*/C158#), were selected to detect antigen in infected rat samples and r-1 HEV- or b HEV-infected human clinical samples. The two candidates showed similar diagnostic efficacy to the Wantai HEV antigen kit in b HEV-infected clinical samples. Genomic divergence resulted in low diagnostic efficacy of the Wantai HEV antigen kit (0%, 0 of 10) for detecting r-1 HEV infection. Compared with the P#1-H4*/C145# candidate (80%, 8 of 10), the P#1-H4*/C158# candidate had excellent diagnostic efficacy in r-1 HEV-infected clinical samples (100%, 10 of 10). The two candidates bind to a discrete antigenic site that is highly conserved across r HEV and b HEV. P#1-H4*/C145# and P#1-H4*/C158# are efficacious candidate antibody combinations for rat HEV antigen detection.


Assuntos
Vírus da Hepatite E , Hepatite E , Ratos , Humanos , Animais , Vírus da Hepatite E/genética , Anticorpos Anti-Hepatite , Técnicas Imunoenzimáticas , Testes Imunológicos
9.
J Med Virol ; 95(1): e28240, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36262025

RESUMO

A wide spectrum of neurological symptoms (NS) has been described in patients with COVID-19. We examined the plasma levels of neuron-specific enolase (NSE) and neurofilament light chain (NFL) together, as neuronal damage markers, and their relationships with clinical severity in patients with NS at acute COVID-19. A total of 20 healthy controls and 59 patients with confirmed COVID-19 were enrolled in this pilot prospective study. Serum NSE and NFL levels were measured by using the enzyme-linked immunoassay method from serum samples. Serum NSE levels were found to be significantly higher in the severe group than in the nonsevere group (p = 0.034). However, serum NFL levels were similar between the control and disease groups (p > 0.05). For the mild group, serum NFL levels were significantly higher in patients with the sampling time ≥5 days than in those with the sampling time <5 days (p = 0.019). However, no significant results for NSE and NFL were obtained in patients with either single or multiple NS across the groups (p > 0.05). Increased serum NSE levels were associated with disease severity regardless of accompanied NS in patients with acute COVID-19 infection. However, serum NFL levels may have a role at the subacute phase of COVID-19.


Assuntos
COVID-19 , Humanos , Projetos Piloto , Estudos Prospectivos , Biomarcadores , Técnicas Imunoenzimáticas
10.
Blood ; 138(4): 299-303, 2021 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-33988688

RESUMO

Vaccination using the adenoviral vector COVID-19 vaccine ChAdOx1 nCoV-19 (AstraZeneca) has been associated with rare vaccine-induced immune thrombotic thrombocytopenia (VITT). Affected patients test strongly positive in platelet factor 4 (PF4)/polyanion enzyme immunoassays (EIAs), and serum-induced platelet activation is maximal in the presence of PF4. We determined the frequency of anti-PF4/polyanion antibodies in healthy vaccinees and assessed whether PF4/polyanion EIA+ sera exhibit platelet-activating properties after vaccination with ChAdOx1 nCoV-19 (n = 138) or BNT162b2 (BioNTech/Pfizer; n = 143). In total, 19 of 281 participants tested positive for anti-PF4/polyanion antibodies postvaccination (All: 6.8% [95% confidence interval (CI), 4.4-10.3]; BNT162b2: 5.6% [95% CI, 2.9-10.7]; ChAdOx1 nCoV-19: 8.0% [95% CI, 4.5% to 13.7%]). Optical densities were mostly low (between 0.5 and 1.0 units; reference range, <0.50), and none of the PF4/polyanion EIA+ samples induced platelet activation in the presence of PF4. We conclude that positive PF4/polyanion EIAs can occur after severe acute respiratory syndrome coronavirus 2 vaccination with both messenger RNA- and adenoviral vector-based vaccines, but many of these antibodies likely have minor (if any) clinical relevance. Accordingly, low-titer positive PF4/polyanion EIA results should be interpreted with caution when screening asymptomatic individuals after vaccination against COVID-19. Pathogenic platelet-activating antibodies that cause VITT do not occur commonly following vaccination.


Assuntos
Autoanticorpos/imunologia , Vacinas contra COVID-19/efeitos adversos , COVID-19/prevenção & controle , Fator Plaquetário 4/imunologia , Polieletrólitos , Púrpura Trombocitopênica Trombótica/etiologia , Vacinação/efeitos adversos , Adulto , Doenças Assintomáticas , Autoanticorpos/sangue , Vacina BNT162 , ChAdOx1 nCoV-19 , Feminino , Pessoal de Saúde , Humanos , Técnicas Imunoenzimáticas , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Ativação Plaquetária , Púrpura Trombocitopênica Trombótica/imunologia , Soroconversão , Trombofilia/etiologia
11.
Blood ; 137(26): 3656-3659, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33945605

RESUMO

Vaccination is crucial in combatting the severe acute respiratory syndrome coronavirus 2 pandemic. The rare complication of thrombocytopenia and thrombotic complications at unusual sites after ChAdOx1 nCov-19 vaccination is caused by platelet-activating antibodies directed against platelet factor 4 (PF4). We present a widely applicable whole-blood standard flow cytometric assay to identify the pathogenic antibodies associated with vaccine-induced immune-mediated thrombotic thrombocytopenia (VITT) after ChAdOx1 nCov-19 vaccination. This assay will enable rapid diagnosis by many laboratories. This trial was registered at www.clinicaltrials.gov as #NCT04370119.


Assuntos
Autoanticorpos/sangue , Vacinas contra COVID-19/efeitos adversos , COVID-19/prevenção & controle , Citometria de Fluxo/métodos , Imunoglobulina G/sangue , Ativação Plaquetária/imunologia , Fator Plaquetário 4/imunologia , Púrpura Trombocitopênica Idiopática/diagnóstico , Receptores de IgG/imunologia , SARS-CoV-2 , Vacinação/efeitos adversos , Especificidade de Anticorpos , Autoanticorpos/biossíntese , Autoanticorpos/imunologia , Vacinas contra COVID-19/imunologia , ChAdOx1 nCoV-19 , Heparina/efeitos adversos , Heparina/imunologia , Humanos , Técnicas Imunoenzimáticas , Imunogenicidade da Vacina , Imunoglobulina G/biossíntese , Imunoglobulina G/imunologia , Selectina-P/análise , Púrpura Trombocitopênica Idiopática/etiologia , Púrpura Trombocitopênica Idiopática/imunologia
12.
Analyst ; 148(6): 1349-1361, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36857647

RESUMO

An electrochemical immunoassay based on the redox cycling method was presented using vertically paired electrodes (VPEs), which were fabricated using poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as an electrode material and parylene-C as a dielectric layer. For the application to immunoassays, different electrochemical properties of PEDOT:PSS were analyzed for the redox reaction of 3,3',5,5'-tetramethylbenzidine (TMB, the chromogenic substrate for enzyme-immunoassays) at different pH conditions, including the conductivity (σ), electron transfer rate constant (kapp), and double-layer capacitance (Cdl). The influencing factors on the sensitivity of redox cycling based on VPE based on PEDOT:PSS were analyzed for the redox reaction of TMB, such as the electrode gap and number of electrode pairs. Computer simulation was also performed for the redox cycling results based on VPEs, which had limitations in fabrication, such as VPEs with an electrode gap of less than 100 nm and more than five electrode pairs. Finally, the redox cycling based on VPE was applied to the medical diagnosis of human hepatitis-C virus (hHCV) using a commercial ELISA kit. The sensitivity of the redox cycling method for the medical diagnosis of hHCV was compared with conventional assay methods, such as TMB-based chromogenic detection, luminol-based chemiluminescence assay, and a rapid test kit (lateral flow immunoassay).


Assuntos
Simulação por Computador , Humanos , Eletrodos , Oxirredução , Imunoensaio , Técnicas Imunoenzimáticas
13.
BMC Infect Dis ; 23(1): 367, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259032

RESUMO

BACKGROUND: As countries move towards or achieve measles elimination status, serosurveillance is an important public health tool. However, a major challenge of serosurveillance is finding a feasible, accurate, cost-effective, and high throughput assay to measure measles antibody concentrations and estimate susceptibility in a population. We conducted a systematic review to assess, characterize, and - to the extent possible - quantify the performance of measles IgG enzyme-linked assays (EIAs) compared to the gold standard, plaque reduction neutralization tests (PRNT). METHODS: We followed the PRISMA statement for a systematic literature search and methods for conducting and reporting systematic reviews and meta-analyses recommended by the Cochrane Screening and Diagnostic Tests Methods Group. We identified studies through PubMed and Embase electronic databases and included serologic studies detecting measles virus IgG antibodies among participants of any age from the same source population that reported an index (any EIA or multiple bead-based assays, MBA) and reference test (PRNT) using sera, whole blood, or plasma. Measures of diagnostic accuracy with 95% confidence intervals (CI) were abstracted for each study result, where reported. RESULTS: We identified 550 unique publications and identified 36 eligible studies for analysis. We classified studies as high, medium, or low quality; results from high quality studies are reported. Because most high quality studies used the Siemens Enzygnost EIA kit, we generate individual and pooled diagnostic accuracy estimates for this assay separately. Median sensitivity of the Enzygnost EIA was 92.1% [IQR = 82.3, 95.7]; median specificity was 96.9 [93.0, 100.0]. Pooled sensitivity and specificity from studies using the Enzygnost kit were 91.6 (95%CI: 80.7,96.6) and 96.0 (95%CI: 90.9,98.3), respectively. The sensitivity of all other EIA kits across high quality studies ranged from 0% to 98.9% with median (IQR) = 90.6 [86.6, 95.2]; specificity ranged from 58.8% to 100.0% with median (IQR) = 100.0 [88.7, 100.0]. CONCLUSIONS: Evidence on the diagnostic accuracy of currently available measles IgG EIAs is variable, insufficient, and may not be fit for purpose for serosurveillance goals. Additional studies evaluating the diagnostic accuracy of measles EIAs, including MBAs, should be conducted among diverse populations and settings (e.g., vaccination status, elimination/endemic status, age groups).


Assuntos
Sarampo , Humanos , Testes de Neutralização/métodos , Técnicas Imunoenzimáticas , Vírus do Sarampo , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G
14.
Gen Comp Endocrinol ; 342: 114351, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37532156

RESUMO

Wildlife researchers seeking to non-invasively examine endocrine function in their study species are presented with a dense and technical 'garden of forking paths' to navigate between collecting a biological sample and obtaining a final measurement. In particular, the choice of which enzyme immunoassay (EIA) to use with collected fecal samples, out of the many options offered by different manufacturers and research laboratories, may be one of the most consequential for final results. However, guidance for making this decision is still emerging. With this gap in mind, we performed a head-to-head comparison of results obtained from four different EIAs for fecal glucocorticoid metabolites (FGCMs), and three different EIAs for fecal androgen metabolites (FAMs), applied to the same set of fecal samples collected from the mountain gorillas (Gorilla beringei beringei) monitored by the Dian Fossey Gorilla Fund in Volcanoes National Park, Rwanda. We provide a) an analytical validation of the different EIAs via tests of parallelism and linearity; b) an estimate of inter-assay correlation between EIA kits designed for the same metabolites; and c) a test of the kits' ecological validity, in which we examine how well each captures endocrine changes following events that theory predicts should result in elevated FGCM and/or FAM concentrations. Our results show that kits differ to some degree in their performance; at the same time, nearly all assays exhibited at least moderate evidence of validity and covariance with others for the same analyte. Our findings, which differ somewhat from similar comparisons performed in other species, demonstrate the need to directly assess assay performance in a species- and context-specific manner as part of efforts to develop the burgeoning discipline of wildlife endocrinology.


Assuntos
Animais Selvagens , Gorilla gorilla , Animais , Glucocorticoides , Gônadas , Técnicas Imunoenzimáticas
15.
Gen Comp Endocrinol ; 330: 114147, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36272448

RESUMO

African penguins (Spheniscus demersus) are an endangered species, with approximately 70,000 mature adults remaining in the wild. Population loss is linked to a combination of environmental and anthropogenic stressors. The aim of the study was to validate a commercially available enzyme immunoassay (EIA) to assess adrenal activity and measure the response to stressors in the feces of African penguins. Fecal samples (n = 609) were collected from 12 African penguins housed at Mystic Aquarium throughout their natural lifecycle, including breeding and molt, where measurable changes in fecal glucocorticoid metabolite (FGM) levels are predicted to occur. Fecal samples collected post-veterinary exam were used for biological validation. Longitudinal analysis shows a significant difference (p = <0.0001) between the average FGM levels during baseline and breeding season, 33.97 ± 1.30 ng/g and 50.21 ± 3.18 ng/g, respectively. Females displayed significantly higher FGM levels than males during both baseline (p = 0.0386; females = 38.80 ± 2.19 ng/g; males = 29.34 ± 1.37 ng/g) and breeding periods (p = 0.0175; females = 57.53 ± 4.84 ng/g; males = 42.69 ± 3.95 ng/g). Average FGM levels decreased significantly over the three-week molting period, from 85.40 ± 20.35 ng/g at week one to 20.23 ± 5.30 ng/g at week three. A seasonal difference in FGM levels was observed in both male and female fecal samples, with Fall having the highest average FGM levels, 54.38 ± 3.64 ng/g, and Summer the lowest, 30.87 ± 2.21 ng/g. General linear mixed model analysis determined that lifecycle (females) and visitor presence (males) were the two factors which best explained the variation in FGM levels observed, however neither factor was found to be significant. These results show FGM analysis can detect physiologically meaningful changes in endocrine activity in African penguins and can be used to monitor health for penguins in aquaria and in the wild, thus contributing to conservation efforts for the survival of the species.


Assuntos
Spheniscidae , Animais , Masculino , Feminino , Spheniscidae/metabolismo , Glucocorticoides/metabolismo , Técnicas Imunoenzimáticas , Fezes/química , Espécies em Perigo de Extinção
16.
Gen Comp Endocrinol ; 341: 114338, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37348682

RESUMO

The pygmy hippopotamus (Choeropsis liberiensis) is an endangered species endemic to the Upper Guinea Forest ecosystem in West Africa. We have limited information concerning the species' reproduction and well-being under managed care. We therefore developed non-invasive methods for characterizing gonadal androgen and adrenal hormone profiles in pygmy hippos using fecal samples collected from 12 males and 12 females housed in North American zoological institutions. We aimed to: 1) identify and validate enzyme immunoassays (EIAs) for measuring metabolites of corticosteroids and testosterone in feces; and 2) test whether gonadal activity is correlated with previous breeding history, season or type of housing. For glucocorticoids, several EIAs for measuring metabolites were investigated. A group-specific EIA exhibiting cross-reactivity with 11,17-dioxoandrostane (DOA) metabolites of cortisol most clearly reflected adrenocortical activity in response to pharmocological challenge with adrenocorticotropic hormone (ACTH) in both males and females. However, day-to-day concentrations of this metabolite in the feces of pygmy hippos that did not undergo ACTH challenge were near the detection limits of the assay, making this EIA impractical for assessing glucocorticoid activity in this species. Another group-specific EIA, exhibiting cross-reactivity with 5α-pregnane-3ß,11ß,21-triol-20-one, produced biologically relevant data and evidence of an appropriate response to pharmacological challenge with exogenous ACTH. The testosterone metabolite assay C196 (Arbor Assays, Ann Arbor, Michigan, USA) also produced biologically coherent data: adult males exhibited the highest mean androgen metabolite concentrations (477 ng/g), followed by adult females (259 ng/g) and juvenile males (160 ng/g). Proven breeding males had higher, but not significantly different, mean concentrations (472 ng/g) to unproven males (352 ng/g; P = 0.400). Similarly, adult males housed outdoors year-round in subtropical climates exhibited higher, but not statistically different mean concentrations (554 ng/g) to males in temperate climates that were housed indoors at least part of the year (412 ng/g; P = 0.208). There were, however, significant differences in mean concentrations among seasons for adult males, with higher values in spring (546 ng/g) and summer (542 ng/g) than in autumn (426 ng/g) and winter (388 ng/g, P = 0.003). In conclusion, we identified EIAs for the measurement of fecal metabolites of androgens and glucocorticoids that can be used for further studies to monitor gonadal activity in male pygmy hippos and adrenocortical activity in both sexes. We also identified a seasonal trend in male gonadal activity in this species under managed care in North America. Finally, our findings highlight an important consideration when using non-invasive methods for evaluating fecal cortisol metabolites: ACTH used for pharmacological validation of an EIA does not necessarily equate to biological relevance.


Assuntos
Artiodáctilos , Glucocorticoides , Feminino , Animais , Masculino , Glucocorticoides/metabolismo , Androgênios , Hidrocortisona/metabolismo , Ecossistema , Testosterona , Hormônio Adrenocorticotrópico/farmacologia , Fezes , Técnicas Imunoenzimáticas
17.
Am J Hum Biol ; 35(8): e23897, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36951242

RESUMO

INTRODUCTION: Multiple studies have reported that milk immune content increases for infants experiencing infectious disease (ID) episodes, suggesting that the immune system of milk (ISOM) offers enhanced protection when needed to combat ID. METHODS: To test the hypothesis that ISOM content and/or activity increases during an infant's ID episode, we characterized milk secretory immunoglobulin A (sIgA; a major ISOM constituent) and in vitro interleukin-6 (IL-6) responses to Salmonella enterica and Escherichia coli, as system-level biomarkers of ISOM activity, in a prospective study among 96 mother-infant dyads in Kilimanjaro, Tanzania. RESULTS: After control for covariates, no milk immune variables (sIgA, Coef: 0.03; 95% CI -0.25, 0.32; in vitro IL-6 response to S. enterica, Coef: 0.23; 95% CI: -0.67, 1.13; IL-6 response to E. coli, Coef: -0.11; 95% CI: -0.98, 0.77) were associated with prevalent ID (diagnosed at the initial participation visit). Among infants experiencing an incident ID (diagnosed subsequent to the initial participation), milk immune content and responses were not substantially higher or lower than the initial visit (sIgA, N: 61; p: 0.788; IL-6 response to S. enterica, N: 56; p: 0.896; IL-6 response to E. coli, N: 36; p: 0.683); this was unchanged by exclusion of infants with ID at the time of initial participation. CONCLUSION: These findings are not consistent with the hypothesis that milk delivers enhanced immune protection when infants experience ID. In environments with a high burden of ID, dynamism may be less valuable to maternal reproductive success than stability in the ISOM.


Assuntos
Infecções por Escherichia coli , Escherichia coli , Imunoglobulina A Secretora , Interleucina-6 , Leite Humano , Infecções por Salmonella , Salmonella enterica , Humanos , Feminino , Leite Humano/química , Interleucina-6/análise , Interleucina-6/imunologia , Salmonella enterica/fisiologia , Infecções por Salmonella/imunologia , Escherichia coli/fisiologia , Infecções por Escherichia coli/imunologia , Recém-Nascido , Lactente , Tanzânia , Estudos Prospectivos , Adulto , Estudos Transversais , Técnicas Imunoenzimáticas , Imunoglobulina A Secretora/análise , Imunoglobulina A Secretora/imunologia , Estudos Longitudinais
18.
Mycoses ; 66(4): 304-307, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36513799

RESUMO

BACKGROUND: Since 2020 the World Health Organization (WHO) recommends Histoplasma antigen detection for the diagnosis of disseminated histoplasmosis (DH) in people living with HIV (PLHIV). OBJECTIVE: Here we aimed to optimise the IMMY's Clarus® Histoplasma GM enzyme immunoassay (EIA), evaluating the best cut-off in the semi-quantitative (SQ-HGM EIA), also known as 'calibrator cut-off procedure'. METHODS: The optimization was done using the quantitative standard procedure (Q-HGM EIA), also known as 'standard curve procedure', as reference test. A retrospective study from an endemic area of DH in southern Brazil was carried out including 264 patients investigated for DH using the test. Receiver Operator Characteristic curve was plotted, and sensitivity and specificity of the SQ-HGM EIA were calculated. RESULTS: The study included 24 positive (values ≥ 0.20 ng/ml) and 240 negative patients by the Q-HGM EIA. According to the manufacturer SQ-HGM EIA protocol, the new SQ-HGM EIA cut-off of 0.8 EIA units was validated, resulting in sensitivity and specificity of 88% and 98.7%, respectively. CONCLUSION: Our study pioneers and brings important data about the optimization of the Histoplasma antigen testing for the diagnosis of DH in a population from Southern Brazil. This optimization also reduced the amount of reagents used, lowering the cost associated with testing.


Assuntos
Histoplasmose , Humanos , Histoplasmose/diagnóstico , Histoplasmose/epidemiologia , Histoplasma , Estudos Retrospectivos , Brasil/epidemiologia , Antígenos de Fungos , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade
19.
Mycopathologia ; 188(6): 1055-1063, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37806994

RESUMO

OBJECTIVE: This study aims to determine the diagnostic utility of galactomannan enzyme immunoassay (GM EIA) in invasive aspergillosis (IA) in children with hematological malignancy (high risk population) in terms of sensitivity, specificity, negative predictive value (NPV) and positive predictive values (PPV) at various cut offs while validating the revised EORTC/MSG 2019 criteria in order to obtain the best cut-off. MATERIAL AND METHODS: For 100 pediatric patients, serum and respiratory samples were collected. Clinical, mycological workup (potassium-hydroxide mount, fungal culture) and GM EIA was done to classify proven, probable, and possible IA as per EORTC-MSG guidelines,2019. Sensitivity, specificity, PPV and NPV were calculated of GM indices at cut-off 0.5, 0.7 and 1, and validated with revised EORTC -MSG, 2019. RESULTS: Of 100 patients enrolled, 75 were diagnosed with ALL, 14 with AML, two with Hodgkin's, three had non-Hodgkin lymphoma, and six had undifferentiated leukemia. With routine mycological findings, 51 were classified as probable IA, 11 as possible IA, and 38 as no IA. Aspergillus flavus was the most prevalent on culture (56.9%, 29/51) followed by A. fumigatus (29%, 15/51) A. niger (7.8%, 4/51), A. terreus (3.9%, 2/51) and A. nidulans (2%, 1/51). GM EIA demonstrated sensitivity 82.3%, specificity 97.4%, PPV 98.1%, and NPV 77.1% at cut-off 0.67 when comparing probable/possible IA v/s no IA groups. The GM EIA had the best sensitivity (82.4%), specificity (81.8%), PPV (95.5%), and NPV (50%) at cut off 0.78 when the probable IA group was compared to the possible IA. Seven patients succumbed of whom 5 had GMI ≥ 2. CONCLUSION: This study deduces the optimal cut-off for serum GM EIA to be 0.67 obtained by ROC analysis when comparing possible and probable IA versus no IA and reinforces the definition of probable category of EORTC-MSG criteria, 2019. At 0.5 ODI the sensitivity (87.1%) and NPV (80.5%) are high, thus making it the most suitable cut-off for detecting true positive and ruling out IA respectively, in pediatric patients with hematological malignancy. GM EIA when performed adjunctive to clinico-radiological findings can prove to be screening, diagnostic and prognostic test for IA in pediatric hematological malignancy patients.


Assuntos
Aspergilose , Neoplasias Hematológicas , Infecções Fúngicas Invasivas , Aspergilose Pulmonar Invasiva , Humanos , Criança , Sensibilidade e Especificidade , Aspergilose/diagnóstico , Infecções Fúngicas Invasivas/diagnóstico , Mananas , Neoplasias Hematológicas/complicações , Técnicas Imunoenzimáticas , Aspergilose Pulmonar Invasiva/diagnóstico
20.
Anaerobe ; 82: 102755, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37406762

RESUMO

BACKGROUND: Diagnosis of Clostridioides difficile Infection (CDI) entails compatible clinical presentation and laboratory findings. We evaluated real-time polymerase chain reaction (qPCR) cycle threshold (CT) as a predictor for disease severity and TcdB enzyme immunoassay (EIA) results. METHODS: Inpatients or emergency department patients who tested positive for tcdB gene by PCR were evaluated. Patients' stools underwent testing for GDH and TcdA/B by EIA. Medical health records were reviewed for demographic, clinical presentation, laboratory, treatment and outcome data. Severity of CDI was calculated using various severity score indexes. RESULTS: The median CT of cases was 32.05 ± 5.45. The optimal cut-off for predicting toxin EIA positivity and severe CDI based on chart review was 32.6 and 29.8, respectively, with the area under the receiver operator characteristics curve (AUC) of 0.74 and 0.60 respectively. CONCLUSION: CT value was an acceptable predictor for EIA toxin but less so for clinical severity. Our study potentially supports a diagnostic algorithm including CT value to reduce the number of EIA toxin assays performed.


Assuntos
Toxinas Bacterianas , Clostridioides difficile , Infecções por Clostridium , Humanos , Toxinas Bacterianas/genética , Toxinas Bacterianas/análise , Clostridioides difficile/genética , Clostridioides/genética , Técnicas Imunoenzimáticas , Infecções por Clostridium/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Fezes/química , Proteínas de Bactérias/genética , Proteínas de Bactérias/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA