Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(8): e14400, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38831639

RESUMO

BACKGROUND: Quality assurance (QA) for ultra-high dose rate (UHDR) irradiation is a crucial aspect in the emerging field of FLASH radiotherapy (FLASH-RT). This innovative treatment approach delivers radiation at UHDR, demanding careful adoption of QA protocols and procedures. A comprehensive understanding of beam properties and dosimetry consistency is vital to ensure the safe and effective delivery of FLASH-RT. PURPOSE: To develop a comprehensive pre-treatment QA program for cyclotron-based proton pencil beam scanning (PBS) FLASH-RT. Establish appropriate tolerances for QA items based on this study's outcomes and TG-224 recommendations. METHODS: A 250 MeV proton spot pattern was designed and implemented using UHDR with a 215nA nozzle beam current. The QA pattern that covers a central uniform field area, various spot spacings, spot delivery modes and scanning directions, and enabling the assessment of absolute, relative and temporal dosimetry QA parameters. A strip ionization chamber array (SICA) and an Advanced Markus chamber were utilized in conjunction with a 2 cm polyethylene slab and a range (R80) verification wedge. The data have been monitored for over 3 months. RESULTS: The relative dosimetries were compliant with TG-224. The variations of temporal dosimetry for scanning speed, spot dwell time, and spot transition time were within ± 1 mm/ms, ± 0.2 ms, and ± 0.2 ms, respectively. While the beam-to-beam absolute output on the same day reached up to 2.14%, the day-to-day variation was as high as 9.69%. High correlation between the absolute dose and dose rate fluctuations were identified. The dose rate of the central 5 × 5 cm2 field exhibited variations within 5% of the baseline value (155 Gy/s) during an experimental session. CONCLUSIONS: A comprehensive QA program for FLASH-RT was developed and effectively assesses the performance of a UHDR delivery system. Establishing tolerances to unify standards and offering direction for future advancements in the evolving FLASH-RT field.


Assuntos
Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Garantia da Qualidade dos Cuidados de Saúde/normas , Terapia com Prótons/métodos , Terapia com Prótons/normas , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas , Radiometria/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias/radioterapia , Imagens de Fantasmas
2.
J Appl Clin Med Phys ; 25(7): e14348, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38561975

RESUMO

INTRODUCTION: Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. METHODS: A stepped acrylic block of specific dimensions is fabricated and placed on top of the DailyQA3 device. Treatment plans comprising of two different spread-out Bragg peaks and five individual spots of 1.0 MU each are designed to be delivered to the device. A mathematical framework to measure the 2D distance between the detectors and individual spot is introduced and play an important role in realizing the spot positioning and centering QA. Lastly, a 5 months trends of the QA for two gantries are presented. RESULTS: The outputs are monitored by two ion chambers in the DailyQA3 and a tolerance of ± 3 % $ \pm 3\% $ are used. The range of the SOBPs are monitored by the ratio of ion chamber signals and a tolerance of ± 1 mm $ \pm 1\ {\mathrm{mm}}$ is used. Four diodes at ± 10 cm $ \pm 10\ {\mathrm{cm}}$ from the central ion chambers are used for spot positioning QA, while the central ion chamber is used for imaging and proton beam isocenter coincidence QA. Using the framework, we determined the absolute signal threshold corresponding to the offset tolerance between the individual proton spot and the detector. A 1.5 mm $1.5\ {\mathrm{mm}}$ tolerances are used for both the positioning and centering QA. No violation of the tolerances is observed in the 5 months trends for both gantries. CONCLUSION: With the proposed approach, we can perform four QA items in the TG224 within 10 min.


Assuntos
Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Terapia com Prótons/métodos , Terapia com Prótons/normas , Humanos , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas , Imagens de Fantasmas , Algoritmos , Radiometria/métodos
3.
BMC Cancer ; 21(1): 944, 2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-34419008

RESUMO

BACKGROUND: Proton beam therapy (PBT) is a new-emerging cancer treatment in China but its treatment costs are high and not yet covered by Chinese public medical insurance. The advanced form of PBT, intensity-modulated proton radiation therapy (IMPT), has been confirmed to reduce normal tissue complication probability (NTCP) as compared to conventional intensity-modulated photon-radiation therapy (IMRT) in patients with oropharyngeal cancer (OPC). Herein, we evaluated the cost-effectiveness and applicability of IMPT versus IMRT for OPC patients in China, aiming at guiding the proper use of PBT. METHODS: A 7-state Markov model was designed for analysis. Base-case evaluation was performed on a 56-year-old (median age of OPC in China) patient under the assumption that IMPT could provide a 25% NTCP-reduction in long-term symptomatic dysphagia and xerostomia. Model robustness was examined using probabilistic sensitivity analysis, cohort analysis, and tornado diagram. One-way sensitivity analyses were conducted to identify the cost-effective scenarios. IMPT was considered as cost-effective if the incremental cost-effectiveness ratio (ICER) was below the societal willingness-to-pay (WTP) threshold. RESULTS: Compared with IMRT, IMPT provided an extra 0.205 quality-adjusted life-year (QALY) at an additional cost of 34,926.6 US dollars ($), and had an ICER of $170,082.4/ QALY for the base case. At the current WTP of China ($33,558 / QALY) and a current IMPT treatment costs of $50,000, IMPT should provide a minimum NTCP-reduction of 47.5, 50.8, 55.6, 63.3 and 77.2% to be considered cost-effective for patient age levels of 10, 20, 30, 40 and 50-year-old, respectively. For patients at the median age level, reducing the current IMPT costs ($50,000) to a $30,000 level would make the minimum NTCP-reduction threshold for "cost-effective" decrease from 91.4 to 44.6%, at the current WTP of China (from 69.0 to 33.5%, at a WTP of $50,000 / QALY; and from 39.7 to 19.1%, at a WTP of $100,000 / QALY). CONCLUSIONS: Cost-effective scenarios of PBT exist in Chinese OPC patients at the current WTP of China. Considering a potential upcoming increase in PBT use in China, such cost-effective scenarios may further expand if a decrease of proton treatment costs occurs or an increase of WTP level.


Assuntos
Análise Custo-Benefício , Custos de Cuidados de Saúde/tendências , Neoplasias Orofaríngeas/economia , Neoplasias Orofaríngeas/radioterapia , Terapia com Prótons/economia , Terapia com Prótons/normas , Gerenciamento Clínico , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Prognóstico , Terapia com Prótons/métodos , Anos de Vida Ajustados por Qualidade de Vida
4.
J Appl Clin Med Phys ; 21(4): 59-67, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32170992

RESUMO

Pencil beam scanning proton therapy makes possible intensity modulation, resulting in improved target dose conformity and organ-at-risk (OAR) dose sparing. This benefit, however, results in increased sensitivity to certain clinical and beam delivery parameters, such as respiratory motion. These effects can cause plan degeneration, which could lead to decreased tumor dose or increased OAR dose. This study evaluated the measurements of proton pencil beam scanning delivery made with a 2D ion chamber array in solid water on a 1D motion platform, where respiratory motion was simulated using sine and cosine4 waves representing sinusoidal symmetric and realistic asymmetric breathing motions, respectively. Motion amplitudes were 0.5 cm and 1 cm corresponding to 1 cm and 2 cm of maximum respiratory excursions, respectively, with 5 sec fixed breathing cycle. The treatment plans were created to mimic spherical targets of 3 cm or 10 cm diameter located at 5 cm or 1 cm depth in solid water phantom. A reference RBE dose of 200 cGy per fraction was delivered in 1, 5, 10, and 15 fractions for each dataset. We evaluated dose conformity and uniformity at the center plane of targets by using the Conformation Number and the Homogeneity Index, respectively. Results indicated that dose conformity as well as homogeneity was more affected by motion for smaller targets. Dose conformity was better achieved for symmetric breathing patterns than asymmetric breathing patterns regardless of the number of fractions. The presence of a range shifter with shallow targets reduced the motion effect by improving dose homogeneity. While motion effects are known to be averaged out over the course of multifractional treatments, this might not be true for proton pencil beam scanning under asymmetrical breathing pattern.


Assuntos
Fracionamento da Dose de Radiação , Movimento , Neoplasias/radioterapia , Terapia com Prótons/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Imagens de Fantasmas , Terapia com Prótons/métodos , Prótons , Radiometria , Reprodutibilidade dos Testes , Respiração
5.
J Appl Clin Med Phys ; 21(3): 123-133, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32141699

RESUMO

Robust optimization has been shown to be effective for stabilizing treatment planning in intensity modulated proton therapy (IMPT), but existing algorithms for the optimization process is time-consuming. This paper describes a fast robust optimization tool that takes advantage of the GPU parallel computing technologies. The new robust optimization model is based on nine boundary dose distributions - two for ±range uncertainties, six for ±set-up uncertainties along anteroposterior (A-P), lateral (R-L) and superior-inferior (S-I) directions, and one for nominal situation. The nine boundary influence matrices were calculated using an in-house finite size pencil beam dose engine, while the conjugate gradient method was applied to minimize the objective function. The proton dose calculation algorithm and the conjugate gradient method were tuned for heterogeneous platforms involving the CPU host and GPU device. Three clinical cases - one head and neck cancer case, one lung cancer case, and one prostate cancer case - were investigated to demonstrate the clinical feasibility of the proposed robust optimizer. Compared with results from Varian Eclipse (version 13.3), the proposed method is found to be conducive to robust treatment planning that is less sensitive to range and setup uncertainties. The three tested cases show that targets can achieve high dose uniformity while organs at risks (OARs) are in better protection against setup and range errors. Based on the CPU + GPU heterogeneous platform, the execution times of the head and neck cancer case and the prostate cancer case are much less than half of Eclipse, while the run time of the lung cancer case is similar to that of Eclipse. The fast robust optimizer developed in this study can improve the reliability of traditional proton treatment planning in a much faster speed, thus making it possible for clinical utility.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias da Próstata/radioterapia , Terapia com Prótons/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Modelos Estatísticos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Fatores de Tempo , Incerteza
6.
Acta Oncol ; 58(4): 483-490, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30632851

RESUMO

This feasibility study shows that Spot-scanning Proton Arc therapy (SPArc) is able to significantly reduce the dose to the hippocampus and cochlea compared to both Volumetric Modulated Arc Photon Therapy (VMAT) and the robust optimized Intensity Modulated Proton Therapy (ro-IMPT) plans in whole brain radiotherapy. Furthermore, SPArc not only improves plan robustness but could potentially deliver a treatment as efficient as ro-IMPT when proton system's energy layer switch time is less than 1 s.


Assuntos
Neoplasias Encefálicas/radioterapia , Cóclea/efeitos da radiação , Irradiação Craniana/métodos , Hipocampo/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Terapia com Prótons/normas , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/patologia , Humanos , Prognóstico , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas
7.
Support Care Cancer ; 27(7): 2679-2691, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30484013

RESUMO

PURPOSE: Patients with brain tumors constitute a vulnerable group, and it is important that they receive the highest quality of care (QoC). The study aim was to describe the perceptions of QoC and its association with health-related quality of life in brain tumor patients undergoing proton beam therapy in a newly established clinic. METHOD: Data were collected at the start of treatment and after 3 and 6 weeks. Adult patients (≥ 18 years old) with brain tumors (n = 186) completed two self-administered questionnaires: a modified Quality from the Patients' Perspective, which measures perceived reality and subjective importance of care, and the EORTC QLQ-C30. Data were analyzed using parametric and non-parametric statistical tests. RESULTS: The perceived QoC was highest for treatment information and lowest for dietician and smoking information, whereas interaction with doctors and nurses was rated as the most important aspect of quality of care. Subjective importance ratings were significantly higher than perceived reality ratings for 60% of items. A better global health was moderately correlated with a higher perceived support for fatigue. CONCLUSIONS: A need for quality improvement was identified for several aspects of patient care. Greater symptom distress during the treatment period led to greater perceived importance of symptom support. Ensuring QoC is complex and collaboration with other health care professionals is essential. RELEVANCE TO CLINICAL PRACTICE: The clinic could improve QoC regarding information about possible symptoms, adjust care according to patient perceptions of importance, and involve patients in care decisions.


Assuntos
Neoplasias Encefálicas/radioterapia , Terapia com Prótons/métodos , Adolescente , Adulto , Idoso , Instituições de Assistência Ambulatorial , Neoplasias Encefálicas/fisiopatologia , Neoplasias Encefálicas/psicologia , Fadiga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Percepção , Terapia com Prótons/normas , Qualidade da Assistência à Saúde , Qualidade de Vida , Inquéritos e Questionários , Adulto Jovem
8.
Acta Oncol ; 57(9): 1259-1264, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29726722

RESUMO

PURPOSE: To investigate the effect of differences in linear energy transfer (LET) and thus the relative biological effectiveness (RBE) between passively scattered proton therapy (PS) and pencil-beam scanning intensity-modulated proton therapy (IMPT). METHODS: IMPT treatment plans were generated for six ependymoma patients, originally treated with PS, using the original plan's computed tomography image sets and beam directions, and its dose-volume values as optimization constraints. Two beam spot sizes and both single-field optimization (SFO) and multi-field optimization (MFO) techniques were used for each patient. Three-dimensional variable-RBE-weighted dose distributions were computed, using Monte Carlo calculated dose and LET distributions, and a linear dose and LET-based RBE model, and were compared between the two delivery methods. RESULTS: Increased target dose coverage and decreased mean and maximum dose to the OARs was achieved with IMPT compared to PS, for constant RBE value of 1.1. Nevertheless, the maximum variable-RBE-weighted dose to the brainstem, was increased up to 6% for the IMPT plans compared to the corresponding PS plans. CONCLUSIONS: IMPT can be dosimetrically superior to PS for ependymoma patients. However, caution should be exercised so that the increased dose conformity is not counteracted by an increase in radiobiological effect in adjacent critical structures.


Assuntos
Ependimoma/radioterapia , Transferência Linear de Energia/fisiologia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Eficiência Biológica Relativa , Calibragem , Estudos de Coortes , Relação Dose-Resposta à Radiação , Humanos , Método de Monte Carlo , Órgãos em Risco , Terapia com Prótons/efeitos adversos , Terapia com Prótons/normas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/normas
9.
Prostate ; 77(6): 686-693, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28156003

RESUMO

BACKGROUND: To test discriminant ability of the 2014 ISUP Gleason grade groups (GGG) for prediction of prostate cancer specific mortality (PCSM) after radical prostatectomy (RP), brachytherapy (BT), external beam radiation (EBRT) or no local treatment (NLT) relative to traditional Gleason grading (TGG). METHODS: In the Surveillance, Epidemiology, and End Results (SEER)-database (2004-2009), 2,42,531 non-metastatic prostate cancer (PCa) patients were identified, who underwent local treatment (RP, BT, EBRT only) or NLT. Follow-up endpoint was PCSM. Biopsy and/or pathological Gleason score (GS) were categorized as TGG ≤6, 7, 8-10 or GGG: I (≤6), II (3 + 4), III (4 + 3), IV (8), and V (9-10). Kaplan-Meier plots, multivariable Cox regression analyses and receiver operating characteristics (ROC) area under the curve analyses (AUC) were used. RESULTS: Median follow-up was 76 months (IQR: 59-94). For the four examined treatment modalities, all five GGG strata and all three TGG strata independently predicted PCSM. GGG yielded 1.5-fold or greater HR differences between GGG II and GGG III, and twofold or greater HR differences between GGG IV and GGG V. Relative to TGG, GGG added 0.4-1.1% to AUC. CONCLUSIONS: This large population-based cohort study confirms the added discriminant properties of the novel GGG strata and confirms a modest gain in predictive accuracy. Prostate 77: 686-693, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Braquiterapia/normas , Vigilância da População , Prostatectomia/normas , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Terapia com Prótons/normas , Idoso , Braquiterapia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância da População/métodos , Prostatectomia/métodos , Neoplasias da Próstata/epidemiologia , Terapia com Prótons/métodos , Programa de SEER/normas , Resultado do Tratamento
10.
Magn Reson Med ; 78(4): 1533-1546, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27851881

RESUMO

PURPOSE: Proton radiation therapy (PRT) is a standard treatment of uveal melanoma. PRT patients undergo implantation of ocular tantalum markers (OTMs) for treatment planning. Ultra-high-field MRI is a promising technique for 3D tumor visualization and PRT planning. This work examines MR safety and compatibility of OTMs at 7.0 Tesla. METHODS: MR safety assessment included deflection angle measurements (DAMs), electromagnetic field (EMF) simulations for specific absorption rate (SAR) estimation, and temperature simulations for examining radiofrequency heating using a bow-tie dipole antenna for transmission. MR compatibility was assessed by susceptibility artifacts in agarose, ex vivo pig eyes, and in an ex vivo tumor eye using gradient echo and fast spin-echo imaging. RESULTS: DAM (α < 1 °) demonstrated no risk attributed to magnetically induced OTM deflection. EMF simulations showed that an OTM can be approximated by a disk, demonstrated the need for averaging masses of mave = 0.01 g to accommodate the OTM, and provided SAR0.01g,maximum = 2.64 W/kg (Pin = 1W) in OTM presence. A transfer function was derived, enabling SAR0.01g estimation for individual patient scenarios without the OTM being integrated. Thermal simulations revealed minor OTM-related temperature increase (δT < 15 mK). Susceptibility artifact size (<8 mm) and location suggest no restrictions for MRI of the nervus opticus. CONCLUSION: OTMs are not a per se contraindication for MRI. Magn Reson Med 78:1533-1546, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Melanoma/radioterapia , Terapia com Prótons/normas , Tantálio/análise , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/radioterapia , Animais , Temperatura Alta , Humanos , Segurança do Paciente , Imagens de Fantasmas , Terapia com Prótons/métodos , Suínos , Tantálio/química
11.
Digestion ; 96(1): 1-4, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28605745

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) is an aggressive liver tumor with a poor 5-year survival rate. Many HCCs are not amenable to surgical resection, because of tumor size, location, or because of the patient's poor liver function, a common obstacle to HCC therapy, because HCCs almost always develop in chronically inflamed livers. SUMMARY: In recent years, many efforts have been made to improve patient survival by conducting clinical trials investigating local and systemic treatment options for patients with unresectable tumors. These treatment options include radiofrequency ablation (RFA), transarterial chemoembolization (TACE), selective internal radiotherapy with yttrium-90 (SIRT), stereotactic body radiation therapy (SBRT), proton beam therapy, molecular targeted therapy, and checkpoint inhibition. In this "to-the-point" article, we review the current standard and summarize the most recent findings in unresectable HCC treatment. KEY POINTS: (1) RFA is currently the preferred treatment for patients with tumor burden restricted to the liver and not eligible for surgical resection; (2) TACE is utilized in patients who are not eligible for RFA because of tumor location and/or number of tumor lesions; (3) SIRT might improve treatment responses achieved by TACE and is feasible in patients with portal vein thrombosis; (4) new radiation therapy treatment modalities such as SBRT and proton beam therapy show promising results for local tumor control; and (5) sorafenib remains the first-line systemic treatment option after several large clinical trials have failed to show superiority of other molecular targeted therapies in HCC patients.


Assuntos
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Guias de Prática Clínica como Assunto , Antineoplásicos Imunológicos/uso terapêutico , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Ablação por Cateter/métodos , Ablação por Cateter/normas , Ablação por Cateter/tendências , Quimioembolização Terapêutica/métodos , Quimioembolização Terapêutica/normas , Quimioembolização Terapêutica/tendências , Ensaios Clínicos como Assunto , Terapia Combinada/métodos , Terapia Combinada/normas , Terapia Combinada/tendências , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Terapia de Alvo Molecular/métodos , Terapia de Alvo Molecular/normas , Terapia de Alvo Molecular/tendências , Niacinamida/análogos & derivados , Niacinamida/uso terapêutico , Compostos de Fenilureia/uso terapêutico , Terapia com Prótons/métodos , Terapia com Prótons/normas , Terapia com Prótons/tendências , Radiocirurgia/métodos , Radiocirurgia/normas , Radiocirurgia/tendências , Radioterapia/métodos , Radioterapia/normas , Radioterapia/tendências , Sorafenibe , Taxa de Sobrevida , Resultado do Tratamento , Carga Tumoral , Radioisótopos de Ítrio/administração & dosagem
12.
J Appl Clin Med Phys ; 18(5): 210-219, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28755419

RESUMO

PURPOSE: In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC-408 plastic scintillator, a commercial camera, and a computer. METHODS: The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose-rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth-dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. RESULTS: The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short-term reproducibility to within 0.80%. No dose rate dependency was observed in this work. CONCLUSIONS: This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams. Furthermore, the system has the advantage of providing 2D visualization of individual radiation fields, with potential application for quality assurance of complex, time-varying fields.


Assuntos
Terapia com Prótons/normas , Contagem de Cintilação/instrumentação , Transferência Linear de Energia , Método de Monte Carlo , Plásticos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
13.
J Appl Clin Med Phys ; 18(2): 15-25, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28300378

RESUMO

Robust optimization of intensity-modulated proton therapy (IMPT) takes uncertainties into account during spot weight optimization and leads to dose distributions that are resilient to uncertainties. Previous studies demonstrated benefits of linear programming (LP) for IMPT in terms of delivery efficiency by considerably reducing the number of spots required for the same quality of plans. However, a reduction in the number of spots may lead to loss of robustness. The purpose of this study was to evaluate and compare the performance in terms of plan quality and robustness of two robust optimization approaches using LP and nonlinear programming (NLP) models. The so-called "worst case dose" and "minmax" robust optimization approaches and conventional planning target volume (PTV)-based optimization approach were applied to designing IMPT plans for five patients: two with prostate cancer, one with skull-based cancer, and two with head and neck cancer. For each approach, both LP and NLP models were used. Thus, for each case, six sets of IMPT plans were generated and assessed: LP-PTV-based, NLP-PTV-based, LP-worst case dose, NLP-worst case dose, LP-minmax, and NLP-minmax. The four robust optimization methods behaved differently from patient to patient, and no method emerged as superior to the others in terms of nominal plan quality and robustness against uncertainties. The plans generated using LP-based robust optimization were more robust regarding patient setup and range uncertainties than were those generated using NLP-based robust optimization for the prostate cancer patients. However, the robustness of plans generated using NLP-based methods was superior for the skull-based and head and neck cancer patients. Overall, LP-based methods were suitable for the less challenging cancer cases in which all uncertainty scenarios were able to satisfy tight dose constraints, while NLP performed better in more difficult cases in which most uncertainty scenarios were hard to meet tight dose limits. For robust optimization, the worst case dose approach was less sensitive to uncertainties than was the minmax approach for the prostate and skull-based cancer patients, whereas the minmax approach was superior for the head and neck cancer patients. The robustness of the IMPT plans was remarkably better after robust optimization than after PTV-based optimization, and the NLP-PTV-based optimization outperformed the LP-PTV-based optimization regarding robustness of clinical target volume coverage. In addition, plans generated using LP-based methods had notably fewer scanning spots than did those generated using NLP-based methods.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Terapia com Prótons/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/normas , Neoplasias Cranianas/radioterapia , Humanos , Modelos Lineares , Masculino , Dinâmica não Linear , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
14.
J Appl Clin Med Phys ; 17(2): 24-40, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074470

RESUMO

The purpose of this study is to describe the comprehensive commissioning process and initial clinical experience of the Mevion S250 proton therapy system, a gantry-mounted, single-room proton therapy platform clinically implemented in the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital in St. Louis, MO, USA. The Mevion S250 system integrates a compact synchrocyclotron with a C-inner gantry, an image guidance system and a 6D robotic couch into a beam delivery platform. We present our commissioning process and initial clinical experience, including i) CT calibration; ii) beam data acquisition and machine characteristics; iii) dosimetric commissioning of the treatment planning system; iv) validation through the Imaging and Radiation Oncology Core credentialing process, including irradiations on the spine, prostate, brain, and lung phantoms; v) evaluation of localization accuracy of the image guidance system; and vi) initial clinical experience. Clinically, the system operates well and has provided an excellent platform for the treatment of diseases with protons.


Assuntos
Neoplasias/radioterapia , Posicionamento do Paciente , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Prótons , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Rotação , Tomografia Computadorizada por Raios X
15.
J Appl Clin Med Phys ; 16(5): 381­388, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699329

RESUMO

The purpose of this study was to evaluate the effectiveness of full three-dimensional (3D) gamma algorithm for spot scanning proton fields, also referred to as pencil beam scanning (PBS) fields. The difference between the full 3D gamma algorithm and a simplified two-dimensional (2D) version was presented. Both 3D and 2D gamma algorithms are used for dose evaluations of clinical proton PBS fields. The 3D gamma algorithm was implemented in an in-house software program without resorting to 2D interpolations perpendicular to the proton beams at the depths of measurement. Comparison between calculated and measured dose points was car-ried out directly using Euclidian distance in 3D space and the dose difference as a fourth dimension. Note that this 3D algorithm faithfully implemented the original concept proposed by Low et al. (1998) who described gamma criterion using 3D Euclidian distance and dose difference. Patient-specific proton PBS plans are separated into two categories, depending on their optimization method: single-field optimization (SFO) or multifield optimized (MFO). A total of 195 measurements were performed for 58 SFO proton fields. A MFO proton plan with four fields was also calculated and measured, although not used for treatment. Typically three dif-ferent depths were selected from each field for measurements. Each measurement was analyzed by both 3D and 2D gamma algorithms. The resultant 3D and 2D gamma passing rates are then compared and analyzed. Comparison between 3D and 2D gamma passing rates of SFO fields showed that 3D algorithm does show higher passing rates than its 2D counterpart toward the distal end, while little difference is observed at depths away from the distal end. Similar phenomenon in the lateral penumbra was well documented in photon radiation therapy, and in fact brought about the concept of gamma criterion. Although 2D gamma algorithm has been shown to suffice in addressing dose comparisons in lateral penumbra for photon intensity-modulation radiation therapy (IMRT) plans, results here showed that a full 3D algorithm is required for proton dose comparisons due to the existence of Bragg peaks and distal penumbra. A MFO proton plan with four fields was also measured and analyzed. Sharp dose gradients exist in MFO proton fields, both in the middle of the modulation and toward the most distal layers. Decreased 2D gamma passing rates at locations of high dose gradient are again observed as in the SFO fields. Results confirmed that a full 3D algorithm for gamma criterion is needed for proton PBS plan's dose comparisons. The 3D gamma algorithm is implemented by an in-house software program. Patient-specific proton PBS plans are measured and analyzed using both 3D and 2D gamma algorithms. For measurements performed at depths with large dose gradients along the beam direction, gamma comparison passing rates using 2D algorithm is lower than those obtained with the full 3D algorithm.


Assuntos
Algoritmos , Raios gama , Neoplasias/radioterapia , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/normas , Humanos , Controle de Qualidade , Dosagem Radioterapêutica , Software
16.
J Appl Clin Med Phys ; 16(6): 472­483, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699545

RESUMO

This study explores the potential of cone-beam computed tomography (CBCT) for monitoring relative beam range variations due to daily changes in patient anatomy for prostate treatment by anterior proton beams. CBCT was used to image an anthropomorphic pelvic phantom, in eight sessions on eight different days. In each session, the phantom was scanned twice, first at a standard position as determined by the room lasers, and then after it was shifted by 10 mm translation randomly along one of the X, Y, or Z directions. The filling of the phantom bladder with water was not refreshed from day to day, inducing gradual change of the water-equivalent path length (WEPL) across the bladder. MIMvista (MIM) software was used to perform image registration and re-alignment of all the scans with the scan from the first session. The XiO treatment planning system was used to perform data analysis. It was found that, although the Hounsfield unit numbers in CBCT have substantially larger fluctuations than those in diagnostic CT, CBCT datasets taken for daily patient positioning could potentially be used to monitor changes in patient anatomy. The reproducibility of the WEPL, computed using CBCT along anterior-posterior (AP) paths across and around the phantom prostate, over a volume of 360 cc, is sufficient for detecting daily WEPL variations that are equal to or larger than 3 mm. This result also applies to CBCT scans of the phantom after it is randomly shifted from the treatment position by 10 mm. limiting the interest to WEPL variation over a specific path within the same CBCT slice, one can detect WEPL variation smaller than 1 mm. That is the case when using CBCT for tracking daily change of the WEPL across the phantom bladder that was induced by spontaneous change in the bladder filling due to evaporation. In summary, the phantom study suggests that CBCT can be used for monitoring day to day WEPL variations in a patient. The method can detect WEPL variation equal to or greater than 3 mm. The study calls for further investigation using the CBCT data from real patients. If confirmed with real patients' data, CBCT could become, in addition to patient setup, a standard tool for proton therapy pretreatment beam range check.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/normas , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Humanos , Masculino , Posicionamento do Paciente , Imagens de Fantasmas , Terapia com Prótons/normas , Terapia com Prótons/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Reprodutibilidade dos Testes , Software , Incerteza , Bexiga Urinária/diagnóstico por imagem , Água
18.
Med Phys ; 50(9): 5817-5827, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37493525

RESUMO

BACKGROUND: The beam energy is one of the most significant parameters in particle therapy since it is directly correlated to the particles' penetration depth inside the patient. Nowadays, the range accuracy is guaranteed by offline routine quality control checks mainly performed with water phantoms, 2D detectors with PMMA wedges, or multi-layer ionization chambers. The latter feature low sensitivity, slow collection time, and response dependent on external parameters, which represent limiting factors for the quality controls of beams delivered with fast energy switching modalities, as foreseen in future treatments. In this context, a device based on solid-state detectors technology, able to perform a direct and absolute beam energy measurement, is proposed as a viable alternative for quality assurance measurements and beam commissioning, paving the way for online range monitoring and treatment verification. PURPOSE: This work follows the proof of concept of an energy monitoring system for clinical proton beams, based on Ultra Fast Silicon Detectors (featuring tenths of ps time resolution in 50 µm active thickness, and single particle detection capability) and time-of-flight techniques. An upgrade of such a system is presented here, together with the description of a dedicated self-calibration method, proving that this second prototype is able to assess the mean particles energy of a monoenergetic beam without any constraint on the beam temporal structure, neither any a priori knowledge of the beam energy for the calibration of the system. METHODS: A new detector geometry, consisting of sensors segmented in strips, has been designed and implemented in order to enhance the statistics of coincident protons, thus improving the accuracy of the measured time differences. The prototype was tested on the cyclotron proton beam of the Trento Protontherapy Center (TPC). In addition, a dedicated self-calibration method, exploiting the measurement of monoenergetic beams crossing the two telescope sensors for different flight distances, was introduced to remove the systematic uncertainties independently from any external reference. RESULTS: The novel calibration strategy was applied to the experimental data collected at TPC (Trento) and CNAO (Pavia). Deviations between measured and reference beam energies in the order of a few hundreds of keV with a maximum uncertainty of 0.5 MeV were found, in compliance with the clinically required water range accuracy of 1 mm. CONCLUSIONS: The presented version of the telescope system, minimally perturbative of the beam, relies on a few seconds of acquisition time to achieve the required clinical accuracy and therefore represents a feasible solution for beam commission, quality assurance checks, and online beam energy monitoring.


Assuntos
Terapia com Prótons , Calibragem , Terapia com Prótons/normas , Fatores de Tempo , Humanos
19.
Radiat Prot Dosimetry ; 199(15-16): 1937-1940, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819291

RESUMO

The radioluminescence (RL) emitted by LiMgPO4 detector under proton beam irradiation was investigated in real time at the radiotherapy facility in the Institute of Nuclear Physics Polish Academy of Sciences in Krakow. The facility uses protons accelerated by the AIC-144 isochronous cyclotron up to the energy of 60 MeV. The measurements of RL were carried out using a remote optical fiber device with a luminophore detector and photomultiplier located at opposite ends of the optical fiber. A thin slice of LiMgPO4 doped with Tm (1.2 mol%) crystal was exposed to the proton beam. The tested detector allowed for the measurement of proton beam current, flux fluence and determination of proton beam time structure parameters. The investigation of LiMgPO4 crystal showed its high sensitivity, fast reaction time to irradiation and possibility of application as the detector for control of proton beam parameters.


Assuntos
Ciclotrons , Terapia com Prótons , Controle de Qualidade , Dosagem Radioterapêutica , Radioterapia , Ciclotrons/instrumentação , Ciclotrons/normas , Luminescência , Polônia , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Prótons , Radioatividade , Radioterapia/normas , Dosagem Radioterapêutica/normas , Metais Leves
20.
Phys Med ; 104: 67-74, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36370605

RESUMO

PURPOSE: To implement a single set-up monthly QA procedure for 9 different beam parameters at different gantry angles and evaluate its clinical implementation over a 12 month period. METHODS: We developed a QA procedure using an array detector (PTW Octavius 1500XDR) embedded in a rotational unit (PTW Octavius 4D) at our proton facility. With a single set-up we can monitor field central axis position, field symmetry, field size, flatness, penumbrae, output, spot size, spot position and range at different gantry angles (AAPM TG 224). The set-up is irradiated with homogenous 2D fields with dynamic aperture and spot patterns at five gantry angles. A modular top is used to check the range consistency. Absolute γ analysis were performed to compare measured dose distributions to calculated dose. All other parameters are directly extracted from the measurements. Additionally, the sensitivity of the set-up to small changes in beam parameters were compared to the Lynx detector (IBA). RESULTS: Over a 12 month period, output, symmetry, and flatness were within ± 2 %; FWHM, spot positions, penumbra widths, and central axis fields were within ± 1 mm. Range differences were all within 1/2 of the energy spacing (±0.6 MeV) relative to baseline. Most (2 %, 2 mm) γ-analysis showed agreement scores higher than 90 %. The sensitivity is comparable to the Lynx detector and measurement time is reduced by 40 %. CONCLUSION: The time-efficient monthly QA procedure that we developed can accurately be used to measure a large range of beam parameters at different gantry angles, within the TG 224 AAPM recommendations.


Assuntos
Terapia com Prótons , Prótons , Garantia da Qualidade dos Cuidados de Saúde , Terapia com Prótons/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA