Técnica e compreensão do uso dos dispositivos inalatórios em pacientes com asma ou DPOC / Knowledge of and technique for using inhalation devices among asthma patients and COPD patients
Souza, Maria Luiza de Moraes; Meneghini, Andrea Cristina; Vianna, Elcio Oliveira; Borges, Marcos Carvalho.
Afiliação
  • Souza, Maria Luiza de Moraes; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
  • Meneghini, Andrea Cristina; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Hospital das Clínicas. Ribeirão Preto. BR
  • Vianna, Elcio Oliveira; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Clínica Médica. Ribeirão Preto. BR
  • Borges, Marcos Carvalho; Universidade Federal de São Carlos. São Carlos. BR
J. bras. pneumol ; J. bras. pneumol;35(9): 824-831, set. 2009. ilus, tab
Article em Pt | LILACS | ID: lil-528386
Biblioteca responsável: BR1.1
RESUMO

OBJETIVO:

Avaliar a compreensão e a técnica de uso dos dispositivos inalatórios prescritos de pacientes com asma ou DPOC atendidos em um hospital-escola terciário.

MÉTODOS:

Os pacientes foram avaliados na sala de pós-consulta sem que o médico soubesse do estudo. Foi solicitado que o paciente demonstrasse como utiliza a medicação inalatória e, em seguida, esse foi entrevistado sobre a compreensão dos dispositivos inalatórios, controle da doença e orientações recebidas durante as consultas.

RESULTADOS:

Foram avaliados 120 voluntários 60 asmáticos e 60 com DPOC. Todos os asmáticos e 98,3 por cento do grupo DPOC relataram saber utilizar os medicamentos inalatórios. Na amostra como um todo, 113 pacientes (94,2 por cento) cometeram pelo menos um erro ao utilizar o dispositivo inalatório. Os pacientes cometeram mais erros ao utilizar aerossol dosimetrado do que ao utilizar os inaladores de pó seco Aerolizer® (p < 0,001) ou Pulvinal® (p < 0,001), assim como mais erros ao utilizar Aerolizer® do que ao utilizar Pulvinal® (p < 0,05). O grupo DPOC cometeu significativamente mais erros que o grupo asma ao utilizar o aerossol dosimetrado (p = 0,0023), Pulvinal® (p = 0,0065) e Aerolizer® (p = 0,012).

CONCLUSÕES:

Embora a maioria dos pacientes relatasse saber a técnica adequada de utilização dos dispositivos inalatórios, 94,2 por cento cometeu pelo menos um erro na utilização dos dispositivos, demonstrando técnica insatisfatória e discrepância entre a compreensão e a prática. Portanto, apenas questionar os pacientes sobre o uso dos dispositivos inalatórios não é suficiente. Medidas práticas devem ser tomadas a fim de diminuir os erros e otimizar a terapêutica.
ABSTRACT

OBJECTIVE:

To evaluate knowledge of and techniques for using prescribed inhalation devices among patients with asthma or COPD treated at a tertiary teaching hospital.

METHODS:

Patients were assessed after medical visits, and their physicians were blinded to this fact. Patients were asked to demonstrate their inhaler technique and were then interviewed regarding their knowledge of inhalation devices, control of the disease and instructions received during medical visits.

RESULTS:

We included 120 volunteers 60 with asthma and 60 with COPD. All of the asthma patients and 98.3 percent of the COPD patients claimed to know how to use inhaled medications. In the sample as a whole, 113 patients (94.2 percent) committed at least one error when using the inhalation device. Patients committed more errors when using metered-dose inhalers than when using the dry-powder inhalers Aerolizer® (p < 0.001) or Pulvinal® (p < 0.001), as well as committing more errors when using the Aerolizer® inhaler than when using the Pulvinal® inhaler (p < 0.05). Using the metered-dose, Pulvinal® and Aerolizer® inhalers, the COPD group patients committed more errors than did the asthma group patients (p = 0.0023, p = 0.0065 and p = 0.012, respectively).

CONCLUSIONS:

Although the majority of the patients claimed to know how to use inhalation devices, the fact that 94.2 percent committed at least one error shows that their technique was inappropriate and reveals a discrepancy between understanding and practice. Therefore, it is not sufficient to ask patients whether they know how to use inhalation devices. Practical measures should be taken in order to minimize errors and optimize treatment.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Asma / Análise e Desempenho de Tarefas / Nebulizadores e Vaporizadores / Conhecimentos, Atitudes e Prática em Saúde / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Qualitative_research Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male Idioma: Pt Revista: J. bras. pneumol Assunto da revista: PNEUMOLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Asma / Análise e Desempenho de Tarefas / Nebulizadores e Vaporizadores / Conhecimentos, Atitudes e Prática em Saúde / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Qualitative_research Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male Idioma: Pt Revista: J. bras. pneumol Assunto da revista: PNEUMOLOGIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil