Fluorescent excitation transfer immunoassay for the determination of spinosyn A in water.
J Agric Food Chem
; 47(7): 2766-70, 1999 Jul.
Article
em En
| MEDLINE
| ID: mdl-10552562
A fluorescent excitation transfer immunoassay for spinosyn A, a fermentation derived insect control agent, has been developed and applied to the analysis of tap water and wastewater effluent from manufacturing plants. Fluorescein (F) and tetramethylrhodamine (TMR) were chosen as donor and quencher, respectively, for the excitation transfer. Fluorescence quenching was observed from the binding of F-labeled antigen to TMR-labeled antibody. By employing nonlabeled antigen in a competitive immunoassay format, we reversed fluorescence quenching. The assay provides a limit of detection of 0. 01 ppb and a working range of 0.05-1 ppb and allows for the rapid determination of spinosyn A in water with recovery values ranging from 96% to 120%. With the exploitation of the small size of optical fibers, fluorescence from an assay volume of 24 microL could be measured without special vessels.