ABSTRACT
INTRODUCTION AND

OBJECTIVES:

Permanent pacemaker implantation is done by different physicians with either a surgical or clinical training. Our objective was to evaluate if there were significant differences in the implantation parameters and in the complication rate among implantations performed by cardiologists in the electrophysiologic laboratory and cardiological surgeons in the operating room. MATERIAL AND

METHODS:

We prospectively collected those patients' data who received a first pacemaker implantation by cardiovascular surgeons and electrophysiologists during the year 1998. Data collected included demographic information, indication for pacing, surgical time, complications during procedure, stimulation and sensing thresholds as well as type of pacing.

RESULTS:

We first-implanted 216 pacemakers in a one year period, 101 by cardiovascular surgeons and 115 by electrophysiologists. 56% were male patients. Average age in the surgery group was 74.2 +/- 9 years and 72.09 +/- 12 in the electrophysiology group (p = NS). Main diagnoses were as follows complete heart block in 32.9% patients, complete heart block 2. degrees 16.4%, sinus node dysfunction 12.2%, AV node ablation 12.2% and others. The complications rate for surgery group was 4% and 1.7% for electrophysiologists (p = NS). Electrophysiologists placed more bicameral devices. No clinically significant differences were found among other implant parameters.

CONCLUSIONS:

Pacemaker implant by cardiologists in an electrophysiologists laboratory is a safe procedure that does not have more complications when compared to the same procedure done in the operating room by surgeons. This allows hospital resource optimization and reduction of hospital stay length.