Your browser doesn't support javascript.
loading
Validation of myocardial perfusion reserve measurements using regularized factor images of H(2)(15)O dynamic PET scans.
Frouin, F; Merlet, P; Bouchareb, Y; Frouin, V; Dubois-Randé, J L; De Cesare, A; Herment, A; Syrota, A; Todd-Pokropek, A.
Afiliação
  • Frouin F; Unité 494, Imagerie Médicale Quantitative, Institut National de la Santé et de la Recherche Médicale, Paris, France.
J Nucl Med ; 42(12): 1737-46, 2001 Dec.
Article em En | MEDLINE | ID: mdl-11752068
ABSTRACT
UNLABELLED The use of H(2)(15)O PET scans for the measurement of myocardial perfusion reserve (MPR) has been validated in both animal models and humans. Nevertheless, this protocol requires cumbersome acquisitions such as C(15)O inhalation or (18)F-FDG injection to obtain images suitable for determining myocardial regions of interest. Regularized factor analysis is an alternative method proposed to define myocardial contours directly from H(2)(15)O studies without any C(15)O or FDG scan. The study validates this method by comparing the MPR obtained by the regularized factor analysis with the coronary flow reserve (CFR) obtained by intracoronary Doppler as well as with the MPR obtained by an FDG acquisition.

METHODS:

Ten healthy volunteers and 10 patients with ischemic cardiopathy or idiopathic dilated cardiomyopathy were investigated. The CFR of patients was measured sonographically using a Doppler catheter tip placed into the proximal left anterior descending artery. The mean velocity was recorded at baseline and after dipyridamole administration. All subjects underwent PET imaging, including 2 H(2)(15)O myocardial perfusion studies at baseline and after dipyridamole infusion, followed by an FDG acquisition. Dynamic H(2)(15)O scans were processed by regularized factor analysis. Left ventricular cavity and anteroseptal myocardial regions of interest were drawn independently on regularized factor images and on FDG images. Myocardial blood flow (MBF) and MPR were estimated by fitting the H(2)(15)O time-activity curves with a compartmental model.

RESULTS:

In patients, no significant difference was observed among the 3 methods of measurement-Doppler CFR, 1.73 +/- 0.57; regularized factor analysis MPR, 1.71 +/- 0.68; FDG MPR, 1.83 +/- 0.49-using a Friedman 2-way ANOVA by ranks. MPR measured with the regularized factor images correlated significantly with CFR (y = 1.17x - 0.30; r = 0.97). In the global population, the regularized factor analysis MPR and FDG MPR correlated strongly (y = 0.99x; r = 0.93). Interoperator repeatability on regularized factor images was 0.126 mL/min/g for rest MBF, 0.38 mL/min/g for stress MBF, and 0.34 for MPR (19% of mean MPR).

CONCLUSION:

Regularized factor analysis provides well-defined myocardial images from H(2)(15)O dynamic scans, permitting an accurate and simple measurement of MPR. The method reduces exposure to radiation and examination time and lowers the cost of MPR protocols using a PET scanner.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardiomiopatia Dilatada / Tomografia Computadorizada de Emissão / Circulação Coronária / Coração Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: França
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardiomiopatia Dilatada / Tomografia Computadorizada de Emissão / Circulação Coronária / Coração Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Nucl Med Ano de publicação: 2001 Tipo de documento: Article País de afiliação: França