Your browser doesn't support javascript.
loading
Areal density measurement is a convenient method for the determination of porcine islet equivalents without counting and sizing individual islets.
Lembert, N; Wesche, J; Petersen, P; Doser, M; Becker, H D; Ammon, H P T.
Afiliação
  • Lembert N; Department of Pharmacology, Auf der Morgenstelle 8, University of Tübingen, 72076 Tübingen, Germany. nicolas.lembert@uni-tuebingen.de
Cell Transplant ; 12(1): 33-41, 2003.
Article em En | MEDLINE | ID: mdl-12693662
ABSTRACT
The determination of islet mass is important for the normalization of islet experiments in the laboratory and for the precise dosing of islets for transplantation. The common microscopical analysis is based on individual islet sizing, calculation of the frequency distribution, and conversion into islet equivalents (IEQ), which is the volume of a spherical islet with a diameter of 150 microm. However, islets are of irregular form, which makes this determination user dependent, and the analysis is irreproducible once the original sample is discarded. This routine technique of islet quantification was compared with the analysis of areal density measurements. It was assumed that the entire area occupied by islets can be expressed in IEQ without sizing and counting individual islets. Porcine islets were isolated by continuous digestion/filtration and purified by gradient centrifugation. Purified islets were stained with dithizone and were repeatedly pictured under the microscope with random area selection. A total of 51 pictures was taken from 11 different purifications and stained islets were detected by digital image analysis. The correlation coefficient (r) between bothanalyses was 0.977 with an underestimation of islet yield by areal density detection (slope 0.75 +/- 0.03). Areal density analysis per picture took about 1 min, which is about 10 times faster than the traditional method without increasing the method error (CV 2.1% vs. 2.7%). In summary, areal density measurements allow a rapid and reproducible estimation of IEQ without counting individual islets. It can be performed in a single step analysis without computer programming and is valuable for online determinations of islet yield preceding transplantation.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Contagem de Células / Transplante das Ilhotas Pancreáticas / Ilhotas Pancreáticas / Técnicas de Cultura de Células / Diabetes Mellitus Tipo 1 Limite: Animals Idioma: En Revista: Cell Transplant Assunto da revista: TRANSPLANTE Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Contagem de Células / Transplante das Ilhotas Pancreáticas / Ilhotas Pancreáticas / Técnicas de Cultura de Células / Diabetes Mellitus Tipo 1 Limite: Animals Idioma: En Revista: Cell Transplant Assunto da revista: TRANSPLANTE Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Alemanha