Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis.
Jung, Byoungsok; Bharadwaj, Rajiv; Santiago, Juan G.
Afiliação
  • Jung B; Department of Mechanical Engineering, Stanford University, CA 94305, USA. bsjung@stanford.edu
Electrophoresis ; 24(19-20): 3476-83, 2003 Oct.
Article em En | MEDLINE | ID: mdl-14595694
Field-amplified sample stacking (FASS) leverages conductivity gradients between a volume of injected sample and the background buffer to increase sample concentration. A major challenge in applying FASS to on-chip assays is the initial setup of high-conductivity gradient boundaries in the region of the injected sample volume. We have designed, fabricated, and characterized a novel FASS-capillary electrophoresis (CE) chip design that uses a photoinitiated porous polymer structure to facilitate sample injection and flow control for high-gradient FASS. This polymer structure provides a region of high flow resistance that allows the electromigration of sample ions. We have demonstrated an electropherogram signal increase by a factor of 1100 in electrophoretic separations of fluorescein and Bodipy with, respectively, 2 microM and 1 microM initial concentrations.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroforese Capilar / Miniaturização Idioma: En Revista: Electrophoresis Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroforese Capilar / Miniaturização Idioma: En Revista: Electrophoresis Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Estados Unidos