Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer.
Int J Radiat Oncol Biol Phys
; 65(4): 1087-96, 2006 Jul 15.
Article
em En
| MEDLINE
| ID: mdl-16682145
PURPOSE: To compare dose-volume histograms (DVH) in patients with non-small-cell lung cancer (NSCLC) treated by photon or proton radiotherapy. METHODS AND MATERIALS: Dose-volume histograms were compared between photon, including three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and proton plans at doses of 66 Gy, 87.5 Gy in Stage I (n=10) and 60-63 Gy, and 74 Gy in Stage III (n=15). RESULTS: For Stage I, the mean total lung V5, V10, and V20 were 31.8%, 24.6%, and 15.8%, respectively, for photon 3D-CRT with 66 Gy, whereas they were 13.4%, 12.3%, and 10.9%, respectively, with proton with dose escalation to 87.5 cobalt Gray equivalents (CGE) (p=0.002). For Stage III, the mean total lung V5, V10, and V20 were 54.1%, 46.9%, and 34.8%, respectively, for photon 3D-CRT with 63 Gy, whereas they were 39.7%, 36.6%, and 31.6%, respectively, for proton with dose escalation to 74 CGE (p=0.002). In all cases, the doses to lung, spinal cord, heart, esophagus, and integral dose were lower with proton therapy even compared with IMRT. CONCLUSIONS: Proton treatment appears to reduce dose to normal tissues significantly, even with dose escalation, compared with standard-dose photon therapy, either 3D-CRT or IMRT.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fótons
/
Carcinoma Pulmonar de Células não Pequenas
/
Radioterapia Conformacional
/
Terapia com Prótons
/
Neoplasias Pulmonares
Limite:
Humans
Idioma:
En
Revista:
Int J Radiat Oncol Biol Phys
Ano de publicação:
2006
Tipo de documento:
Article
País de afiliação:
Estados Unidos