Infrared-based module for the synthesis of 68Ga-labeled radiotracers.
Azhdarinia, Ali; Yang, David J; Chao, Clifford; Mourtada, Firas.
Afiliação
  • Azhdarinia A; Department of Experimental Diagnostic Imaging, The University of Texas M.D. Anderson Cancer Center, Houston, TX 77030, USA.
Nucl Med Biol ; 34(1): 121-7, 2007 Jan.
Article em En | MEDLINE | ID: mdl-17210469
INTRODUCTION: Generator-produced positron emission tomography tracers have gained much attention recently due to favorable imaging characteristics, accessibility and affordability. The focus of this study was to design and validate a semiautomated module for 68Ga-labeled chemistry utilizing infrared-based heating for rapid control of thermal cycle. METHODS: A prototype module was built and installed in our laboratory. DOTA (1,4,7,10-tetra-azacyclododecane-1,4,7,10-tetra-acetic acid) was manually labeled (10-1000 nmol) with 68Ga to optimize synthesis conditions. For automation, 250 nmol of DOTA was labeled with 68Ga with reaction times of 5 min (n=5), 10 min (n=5) and 20 min (n=6). A dose calibrator and radio-thin-layer chromatography were used to access the product yield and quality of both manual and automated syntheses. RESULTS: A semiautomated 68Ga synthesis module was developed. The system showed that software control could be used to drive a multistep radiochemical synthesis and to produce 68Ga-DOTA with >95% radiochemical purity, similar to that in manual synthesis. The device also showed that for a short reaction time of 5 min, decay-corrected radioactive yields of >70% could be achieved. The total synthesis was as short as 22 min, including 6-8 min for HCl evaporation. The temperature and pressure profiles of the process were consistent. CONCLUSION: We demonstrated the use of a commercially available 68Ga/68Ge generator with a semiautomated module to successfully label the bifunctional chelator DOTA with 68Ga. Further investigation with different 68Ga-labeled bioconjugates is warranted to demonstrate the usefulness of the module as a tool for tracer development and imaging research.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Química Farmacêutica / Compostos Radiofarmacêuticos / Radioisótopos de Gálio / Calefação / Marcação por Isótopo Idioma: En Revista: Nucl Med Biol Assunto da revista: BIOLOGIA / MEDICINA NUCLEAR Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Robótica / Química Farmacêutica / Compostos Radiofarmacêuticos / Radioisótopos de Gálio / Calefação / Marcação por Isótopo Idioma: En Revista: Nucl Med Biol Assunto da revista: BIOLOGIA / MEDICINA NUCLEAR Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Estados Unidos