Your browser doesn't support javascript.
loading
Accuracy of pre- and postcontrast 3D time-of-flight MR angiography in patients with acute ischemic stroke: correlation with catheter angiography.
Ishimaru, H; Ochi, M; Morikawa, M; Takahata, H; Matsuoka, Y; Koshiishi, T; Fujimoto, T; Egawa, A; Mitarai, K; Murakami, T; Uetani, M.
Afiliação
  • Ishimaru H; Department of Radiology, National Hospital Organization Nagasaki Medical Center, Omura, Japan. ishimaruh@nmc.hosp.go.jp
AJNR Am J Neuroradiol ; 28(5): 923-6, 2007 May.
Article em En | MEDLINE | ID: mdl-17494671
ABSTRACT
BACKGROUND AND

PURPOSE:

3D time-of-flight (TOF) MR angiography (MRA) is insensitive to slow flow; however, the use of MR imaging contrast agents helps to visualize slow-flow vessels and avoids overestimation of vascular occlusion. The purpose of this study was to correlate pre- and postcontrast 3D TOF MRA with the results of conventional angiography during endovascular reperfusion therapy and to determine the accuracy of postcontrast 3D TOF MRA. MATERIALS AND

METHODS:

Thirteen patients who underwent endovascular reperfusion therapy for acute ischemic stroke were retrospectively analyzed. MR imaging techniques included single-slab 3D TOF MRA with and without contrast, as well as perfusion-weighted imaging. Angiography during reperfusion therapy was used as a standard of reference. Affected arteries were divided into segments either proximal or distal to the lesion, and pre- and postcontrast MRA signals were graded as absent, diminished or narrowed, or normal.

RESULTS:

In 2 of 5 patients with arterial stenosis and 6 of 8 patients with complete occlusion, MRA signal intensity proximal to each lesion was absent, indicating a proximal pseudo-occlusion on precontrast MRA. Postcontrast MRA demonstrated an arterial signal intensity proximal to the stenotic or occlusive lesions in all 13 patients. Arterial signal intensity distal to the occlusion was identified on postcontrast MRA in 7 of 8 patients having complete occlusion, and the extent of occlusion on postcontrast MRA was similar to results of conventional angiography.

CONCLUSION:

In this small series, postcontrast 3D TOF MRA more accurately delineated the extent of stenotic or occlusive arterial lesions than precontrast MRA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Isquemia Encefálica / Angiografia por Ressonância Magnética / Acidente Vascular Cerebral Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Isquemia Encefálica / Angiografia por Ressonância Magnética / Acidente Vascular Cerebral Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Japão