Your browser doesn't support javascript.
loading
Upright static pelvic posture as rotations and translations in 3-dimensional from three 2-dimensional digital images: validation of a computerized analysis.
Harrison, Deed E; Janik, Tadeusz J; Cailliet, Rene; Harrison, Donald D; Normand, Martin C; Perron, Denise L; Oakley, Paul A.
Afiliação
  • Harrison DE; Chiropractic Biophysics, Non Profit, Inc., Elko, Nevada, USA.
J Manipulative Physiol Ther ; 31(2): 137-45, 2008 Feb.
Article em En | MEDLINE | ID: mdl-18328940
ABSTRACT

PURPOSE:

The aim of this study was to determine the accuracy in measuring the pelvic orientations of a phantom model using the PosturePrint method.

METHODS:

In the Université du Québec à Trois-Rivières biomechanics laboratory, Trois-Rivières, Quebec, Canada, a mannequin was fixed on a rotating platform. For a set of 3 photographs (left lateral, anterior to posterior, right lateral) of each position, the mannequin pelvis was placed in 68 different postures on a stand, 61 cm from a wall, in front of a digital camera. The camera was at 83.8 cm in height and at 3.35 m from a calibrated wall grid. Mannequin postures were in 5 degrees of freedom lateral translation (Tx), lateral flexion (Rz), axial rotation (Ry), flexion-extension (Rx), and anterior-posterior translation (Tz). Average errors were the differences of the positioned postures to the PosturePrint computed values.

RESULTS:

Mean and SD of computational errors for rotation displacements were Rx = 0.5 degrees +/- 0.8 degrees , Ry = 1.3 degrees +/- 0.8 degrees , and Rz = 0.5 degrees +/- 0.3 degrees , and for translation, Tz = 1.2 +/- 0.6 mm and Tx = 0.9 +/- 0.5 mm.

CONCLUSIONS:

The PosturePrint system allowed for accurate postural measurement of rotations and translations of a mannequin pelvis. The next step in evaluation of this product would be a reliability study on human subjects.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Postura / Processamento de Imagem Assistida por Computador / Imageamento Tridimensional Idioma: En Revista: J Manipulative Physiol Ther Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Postura / Processamento de Imagem Assistida por Computador / Imageamento Tridimensional Idioma: En Revista: J Manipulative Physiol Ther Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos