Your browser doesn't support javascript.
loading
Capsule endoscopy for the detection of oesophageal mucosal disorders: a comparison of two different ingestion protocols.
De Jonge, Pieter J F; Van Eijck, Brechje C; Geldof, Han; Bekkering, Frank C; Essink-Bot, Marie-Louise; Polinder, Suzanne; Kuipers, Ernst J; Siersema, Peter D.
Afiliação
  • De Jonge PJ; Department of Gastroenterology and Hepatology, Erasmus MC - University Medical Center Rotterdam, The Netherlands. p.dejonge@erasmusmc.nl
Scand J Gastroenterol ; 43(7): 870-7, 2008.
Article em En | MEDLINE | ID: mdl-18584526
OBJECTIVE: To assess the accuracy of a new ingestion protocol for capsule endoscopy (CE) in evaluating patients with gastro-oesophageal reflux disease (GORD). METHODS: Oesophago-gastroduodenoscopy (OGD) was performed 1 week prior to CE. The first 28 subjects swallowed the capsule following the original ingestion protocol (OIP) and the subsequent 30 subjects following a simplified ingestion protocol (SIP). CE videos were reviewed by two independent investigators who were blinded to the OGD findings. RESULTS: Of 48 patients included, 24 were diagnosed with reflux oesophagitis (67% male, mean age 49.5+/-13 years) and 24 with Barrett oesophagus (BO) (88% male, 55.6+/-10 years) by OGD. In addition, 10 asymptomatic healthy controls (50% male, 45.8+/-7.1 years) were included. Oesophageal transit time was faster in patients using the SIP compared to the OIP (126+/-26 s versus 214+/-33; p=0.04). Complete evaluation of the Z-line was possible in 19/28 (68%) of the OIPs compared to 28/30 (93%) of the SIPs (p=0.04). Sensitivity for detecting any oesophageal abnormality was higher in the SIP group than in the OIP group (97% versus 89%; p=0.11). Overall, CE detected oesophagitis in 22/24 patients (sensitivity, 92%; specificity, 88%) and BO in 23/24 patients (sensitivity, 96%; specificity, 91%). Furthermore, 41/44 (93%) preferred CE over OGD and experienced less discomfort and pain during CE. CONCLUSION: CE is an accurate method for detecting mucosal oesophageal abnormalities. The new ingestion protocol improves the visualization of the Z-line, which is likely to increase the diagnostic yield of CE.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças do Esôfago / Endoscopia por Cápsula Tipo de estudo: Diagnostic_studies / Guideline / Health_economic_evaluation / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Scand J Gastroenterol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças do Esôfago / Endoscopia por Cápsula Tipo de estudo: Diagnostic_studies / Guideline / Health_economic_evaluation / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Scand J Gastroenterol Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Holanda