Your browser doesn't support javascript.
loading
Diagnosis of x-ray heated Mg/Fe opacity research plasmas.
Bailey, J E; Rochau, G A; Mancini, R C; Iglesias, C A; MacFarlane, J J; Golovkin, I E; Pain, J C; Gilleron, F; Blancard, C; Cosse, Ph; Faussurier, G; Chandler, G A; Nash, T J; Nielsen, D S; Lake, P W.
Afiliação
  • Bailey JE; Sandia National Laboratories, Albuquerque, New Mexico 87185-1196, USA.
Rev Sci Instrum ; 79(11): 113104, 2008 Nov.
Article em En | MEDLINE | ID: mdl-19045886
ABSTRACT
Understanding stellar interiors, inertial confinement fusion, and Z pinches depends on opacity models for mid-Z plasmas in the 100-300 eV temperature range. These models are complex and experimental validation is crucial. In this paper we describe the diagnosis of the first experiments to measure iron plasma opacity at a temperature high enough to produce the charge states and electron configurations that exist in the solar interior. The dynamic Hohlraum x-ray source at Sandia National Laboratories' Z facility was used to both heat and backlight Mg/Fe CH tamped foils. The backlighter equivalent brightness temperature was estimated to be T(r) approximately 314 eV+/-8% using time-resolved x-ray power and imaging diagnostics. This high brightness is significant because it overwhelms the sample self-emission. The sample transmission in the 7-15.5 A range was measured using two convex potassium acid phthalate crystal spectrometers that view the backlighter through the sample. The average spectral resolution over this range was estimated to be lambda/deltalambda approximately 700 by comparing theoretical crystal resolution calculations with measurements at 7.126, 8.340, and 12.254 A. The electron density was determined to be n(e)=6.9+/-1.7 x 10(21) cm(-3) using the Stark-broadened Mg Hebeta, Hegamma, and Hedelta lines. The temperature inferred from the H-like to He-like Mg line ratios was T(e)=156+/-6 eV. Comparisons with three different spectral synthesis models all have normalized chi(2) that is close to unity, indicating quantitative consistency in the inferred plasma conditions. This supports the reliability of the results and implies the experiments are suitable for testing iron opacity models.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos