Your browser doesn't support javascript.
loading
An analysis of the effect of a vent hole on excess cement expressed at the crown-abutment margin for cement-retained implant crowns.
Patel, Dipan; Invest, James C F; Tredwin, Christopher J; Setchell, Derrick J; Moles, David R.
Afiliação
  • Patel D; Unit of Prosthodontics, UCL Eastman Dental Institute, University College London, London, UK.
J Prosthodont ; 18(1): 54-9, 2009 Jan.
Article em En | MEDLINE | ID: mdl-19166549
PURPOSE: The labial margins of anterior implant-retained crowns are often positioned subgingivally for a superior esthetic appearance. One of the consequences of subgingival margins is the increased risk of leaving excess cement behind following cementation. This can lead to potential problems, including peri-implant inflammation, soft tissue swelling, soreness, bleeding or suppuration on probing, and bone loss. The purpose of this laboratory study was to investigate the effect of placement, location, and diameter of a vent hole on the amount of cement being expressed at the margin of an anterior implant abutment-retained crown. MATERIALS AND METHODS: Three implant crown copings were fabricated to fit on the same custom abutment. Three vent diameters (0.75, 1.25, and 1.65 mm) and three locations on the palatal surface of the coping (cervico-palatally, mid-palatally, inciso-palatally) were chosen for vent hole placement. For each test, the coping was cemented onto the abutment under standardized conditions. A preweighed thin coating of cement was applied to the fit surface of the coping. The amount of cement expressed at the margin and vent hole was measured by weight and calculated as a proportion of the amount of cement placed in the coping before seating. The procedure was completed 15 times for each variable. The results were statistically analyzed using univariate ANOVA with post hoc Bonferroni-adjusted independent samples t-tests. RESULTS: The presence of a vent hole influenced the proportion of cement expressed at the coping margin (p < 0.05). The location of a vent hole influenced the proportion of cement expressed at the coping margin (p < 0.05), with the exception of the mid-palatal and inciso-palatal positioning where there was no significant difference (p= 0.61) between groups. The diameter of the vent hole did not significantly influence the proportion of cement expressed at the coping margin (p= 0.096). CONCLUSIONS: When using anterior cement-retained implant crowns, the use of a 0.75-mm mid-palatal or inciso-palatal vent hole to minimize the amount of cement expressed at the margin during cementation should be considered.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnica de Fundição Odontológica / Dente Suporte / Cimentação / Planejamento de Prótese Dentária / Prótese Dentária Fixada por Implante / Coroas Tipo de estudo: Etiology_studies Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnica de Fundição Odontológica / Dente Suporte / Cimentação / Planejamento de Prótese Dentária / Prótese Dentária Fixada por Implante / Coroas Tipo de estudo: Etiology_studies Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2009 Tipo de documento: Article