Your browser doesn't support javascript.
loading
Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging.
Kato, Y; Higano, S; Tamura, H; Mugikura, S; Umetsu, A; Murata, T; Takahashi, S.
Afiliação
  • Kato Y; Department of Diagnostic Radiology, Tohoku University Graduate School of Medicine, Sendai, Miyagi-ken, Japan. ykato@rad.med.tohoku.ac.jp
AJNR Am J Neuroradiol ; 30(5): 923-9, 2009 May.
Article em En | MEDLINE | ID: mdl-19213825
ABSTRACT
BACKGROUND AND

PURPOSE:

Early accurate diagnosis of brain metastases is crucial for a patient's prognosis. This study aimed to compare the conspicuity and detectability of small brain metastases between contrast-enhanced 3D fast spin-echo (sampling perfection with application-optimized contrasts by using different flip angle evolutions [SPACE]) and 3D gradient-echo (GE) T1-weighted (magnetization-prepared rapid acquisition of GE [MPRAGE]) images at 3T. MATERIALS AND

METHODS:

Sixty-nine consecutive patients with suspected brain metastases were evaluated prospectively by using SPACE and MPRAGE on a 3T MR imaging system. After careful evaluation by 2 experienced neuroradiologists, 92 lesions from 16 patients were selected as brain metastases. We compared the shorter diameter, contrast rate (CR), and contrast-to-noise ratio (CNR) of each lesion. Diagnostic ability was compared by using receiver operating characteristic (ROC) analysis. Ten radiologists (5 neuroradiologists and 5 residents) participated in the reading.

RESULTS:

The mean diameter was significantly larger by using SPACE than MPRAGE (mean, 4.5 +/- 3.7 versus 4.3 +/- 3.7 mm, P = .0014). The CR and CNR of SPACE (mean, 57.3 +/- 47.4%, 3.0 +/- 1.9, respectively) were significantly higher than those of MPRAGE (mean, 37.9 +/- 41.2%, 2.6 +/- 2.2; P < .0001, P = .04). The mean area under the ROC curve was significantly larger with SPACE than with MPRAGE (neuroradiologists, 0.99 versus 0.88, P = .013; residents, 0.99 versus 0.78, P = .0001).

CONCLUSIONS:

Lesion detectability was significantly higher on SPACE than on MPRAGE, irrespective of the experience of the reader in neuroradiology. SPACE should be a promising diagnostic technique for assessing brain metastases.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Neoplasias Encefálicas / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Gadolínio DTPA / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Neoplasias Encefálicas / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Gadolínio DTPA / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Japão