Your browser doesn't support javascript.
loading
European Contegra multicentre study: 7-year results after 165 valved bovine jugular vein graft implantations.
Breymann, T; Blanz, U; Wojtalik, M A; Daenen, W; Hetzer, R; Sarris, G; Stellin, G; Planche, C; Tsang, V; Weissmann, N; Boethig, D.
Afiliação
  • Breymann T; Cardiac, Thoracic, Transplant and Vascular Surgery, Hannover Medical School, 30625 Hannover, Germany.
Thorac Cardiovasc Surg ; 57(5): 257-69, 2009 Aug.
Article em En | MEDLINE | ID: mdl-19629887
ABSTRACT

OBJECTIVE:

The valved bovine conduit "Contegra" for RVOT reconstruction became available for clinical use within a 100 % source data monitored and echo core lab controlled prospective European Multicentre Study, carried out from 1999 to 2006. We present the results of this study.

METHODS:

A total of 165 Contegras were implanted in 8 centres. The mean patient age was 3.9 years (2 days - 18 years, median 2.0). Total follow-up was 687 patient years. Diagnoses included tetralogy of Fallot (64 patients, 39 %), truncus arteriosus (50, 30 %), double outlet right ventricle (16, 10 %), aortic valve disease/Ross procedure (11, 7 %), pulmonary valve atresia (10, 6 %), transposition of the great arteries (10, 6 %), 4 other malformations (2 %). Previous procedures were 82 patients (50 %) - none; 37 (22 %) - valved conduit implantation; 14 (8 %) aortopulmonary shunt; 6 (4 %) catheter intervention. Follow-up appointments which included standardised echocardiography investigations were scheduled at 1, 3, 6, and 12 months, then annually. We evaluated freedom from death, explantation, intervention, stenosis, insufficiency, and degeneration. Results were stratified by age, diagnosis group and conduit size.

RESULTS:

The 5-year freedom-from rates were explantation - 90 % (for patients aged 1 to 10 years) and 68 % (for younger patients); endocarditis - over 92 %; catheter intervention - 74 % (patients with congenital malformations); stenosis - 75 % and more (any group); insufficiency - 50 % (12 and 14 mm diameter conduits); any event - 13 % (patients under 1 year), 58 % (1 to 10 years), 82 % (> 10 years). Trace or mild insufficiency was a frequent, but not progressive finding. Mild calcification was detected in only 8 examinations.

CONCLUSIONS:

The performance of the Contegra conduit compares well with that of homografts when used to reconstruct paediatric right ventricular outflow tracts.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução do Fluxo Ventricular Externo / Cardiopatias Congênitas / Procedimentos Cirúrgicos Cardíacos / Veias Jugulares Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies País/Região como assunto: Europa Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução do Fluxo Ventricular Externo / Cardiopatias Congênitas / Procedimentos Cirúrgicos Cardíacos / Veias Jugulares Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies País/Região como assunto: Europa Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Alemanha