[Results of fine-needle aspiration cytology (FNAC) in the diagnosis of indeterminate solid renal tumours]. / Résultats de l'aspiration cytologique à l'aiguille fine dans le diagnostic des tumeurs solides du rein de nature indéterminée.
Li, G; Cuilleron, M; Cottier, M; Rambaud, B; Tostain, J; Gigante, M.
Afiliação
  • Li G; Service d'urologie-andrologie, CHU de Saint-Etienne, université Jean-Monnet, Saint-Etienne, France. grli2001@yahoo.fr
Prog Urol ; 20(1): 30-4, 2010 Jan.
Article em Fr | MEDLINE | ID: mdl-20123525
ABSTRACT

OBJECTIVE:

To evaluate the accuracy of fine-needle aspiration cytology for the diagnosis of imaging indeterminate solid renal tumours. MATERIALS AND

METHODS:

From February 2003 to February 2009, 60 cytoaspirations have been performed to 20 female and 40 male patients (average age 62.0+/-14.2 years) with an indeterminate solid renal mass by imaging. The average tumour size was 3.4+/-2.8 cm. The cytoaspiration was performed through a 22 Gauge needle under CT (n=39) or US (n=21) guidance. Papanicolaou staining was used. All slides were examined by one experienced cytologist without any clinicoradiological information. The results were given as malignant, benign, suspect or non significant. A classification of subtypes of renal cancer might be added by the cytologist.

RESULTS:

Twenty-one cytoaspirations (35%) were non significant while 39 (65%) showed cells of interest. Among these 39 cellular cytoaspirations, the specificity for malignancy or benignity was 89.7%. The proportion of non-significant samples was the same in tumors lesser than 2 cm (38.4%) as in tumors 2-4 cm (38.8%) (p=1.000, Fisher's exact test). Subtype identification was only reliable for clear cell carcinomas. No complication was observed.

CONCLUSION:

The fine-needle aspiration cytology is an auxiliary technique for the diagnosis of indeterminate solid renal tumours. This simple and mini-invasive technique had a high specificity but a low sensitivity in our experience. Fine-needle aspiration is complementary to core biopsy which remains the gold standard of percutaneous sampling.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Renais Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: Fr Revista: Prog Urol Assunto da revista: UROLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Renais Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: Fr Revista: Prog Urol Assunto da revista: UROLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: França