Your browser doesn't support javascript.
loading
Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.
Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude.
Afiliação
  • Glineur D; Department of Cardiovascular Medicine and Surgery, University of Louvain Medical School, Brussels, Belgium. david.glineur@uclouvain.be
J Thorac Cardiovasc Surg ; 140(3): 639-45, 2010 Sep.
Article em En | MEDLINE | ID: mdl-20167333
ABSTRACT

BACKGROUND:

Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. PATIENTS AND

METHODS:

We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation.

RESULTS:

At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches.

CONCLUSIONS:

Composite Y-grafts with saphenous vein or right internal thoracic arteries allow similar and adequate reperfusion of the left system with minimal resistance to maximal flow and an even distribution of flow in both distal branches.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Safena / Ponte de Artéria Coronária / Reserva Fracionada de Fluxo Miocárdico / Anastomose de Artéria Torácica Interna-Coronária / Artéria Torácica Interna Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Thorac Cardiovasc Surg Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Safena / Ponte de Artéria Coronária / Reserva Fracionada de Fluxo Miocárdico / Anastomose de Artéria Torácica Interna-Coronária / Artéria Torácica Interna Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Thorac Cardiovasc Surg Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica