Your browser doesn't support javascript.
loading
Postoperative complications in patients with cochlear implants and impacts of nursing intervention.
Hou, Jun-Hua; Zhao, Shu-Ping; Ning, Fei; Rao, Shao-Qi; Han, Dong-Yi.
Afiliação
  • Hou JH; Department of Otorhinolaryngology/Head and Neck Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.
Acta Otolaryngol ; 130(6): 687-95, 2010 Jun.
Article em En | MEDLINE | ID: mdl-20377501
ABSTRACT

CONCLUSION:

This study shows that cochlear implantation is relatively safe surgery with few major complications and within acceptable limits. However, close follow-up observation and effective medical and nursing intervention could alleviate further complications and thus become key elements for promoting recovery of patients undergoing such surgery.

OBJECTIVES:

Cochlear implantation has become an effective method for curing patients disabled by profound hearing loss in China. However, full exploration of the associated complications remains to be completed. The objective of this study was thus to analyse the postoperative complications in patients with cochlear implants (CIs) in order to design improved measures for clinical and nursing interventions.

METHODS:

A retrospective study of 262 patients receiving CIs at the Department of Otorhinolaryngology/Head and Neck Surgery, Chinese People's Liberation Army General Hospital, Beijing, China from March 1997 to December 2006 was conducted.

RESULTS:

Among 262 patients, 4 cases (1.5%) had 1 or more major complications requiring substantial medical or nursing interventions, including 1 case of cerebrospinal fluid (CSF) otorrhoea accompanied by meningitis, 2 cases of facial nerve paresis and 1 case of perforation of tympanic membrane. Forty cases (15.3%) had some form of minor complication that settled spontaneously or easily with conventional treatments and nursing, of which dizziness and vomiting was the most frequent (4.2%), followed by CSF gusher without otorrhoea and/or induced meningitis (2.7%), tinnitus (1.9%) and facial nerve partially exposed without paralysis (1.5%). Eleven cases (4.2%) had some symptoms associated with installation of the cochlear device. Except for one patient who had no response after implantation because his auditory nerves were underdeveloped, all the patients who received appropriate treatment and nursing intervention had a favourable prognosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Implante Coclear Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Acta Otolaryngol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Implante Coclear Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Acta Otolaryngol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: China