Usefulness of frequency-doubling technology for perimetrically normal eyes of open-angle glaucoma patients with unilateral field loss.
Ophthalmology
; 117(8): 1530-7, 1537.e1-2, 2010 Aug.
Article
em En
| MEDLINE
| ID: mdl-20466428
PURPOSE: To determine whether frequency-doubling technology (FDT) perimetry detects visual field loss in perimetrically normal eyes of patients with open-angle glaucoma (OAG) and whether these visual field defects subsequently are detected by standard automated perimetry (SAP), and to explore the relating factors of the progression from abnormalities based on FDT to visual field loss based on SAP. DESIGN: Prospective cohort study. PARTICIPANTS: Sixty-eight OAG patients with unilateral field loss detected by SAP (Octopus, G2 program; Interzeig, Schlieren, Switzerland). METHODS: Perimetrically normal eyes of participants were examined with the FDT N-30 threshold program (Humphrey Instruments, Welch-Allyn, Skaneateles, NY). The visual field examination was followed by a series of SAP examinations administered over 3 years. MAIN OUTCOME MEASURES: The relationship between FDT and subsequent SAP results in perimetrically normal eyes was analyzed. Glaucomatous optic neuropathy (GON), visual field indices, intraocular pressure (IOP), and central corneal thickness (CCT) were compared between converters (eyes with subsequent SAP abnormality) and nonconverters within perimetrically normal eyes with abnormal FDT results. Finally, the SAP test points were matched to the abnormal FDT sectors. The relative risk (RR) of subsequent SAP abnormality corresponding to FDT abnormal sectors was calculated. RESULTS: Sixty perimetrically normal eyes of 60 participants had complete data and a qualifying follow-up. Baseline FDT results were abnormal in 65%. Of the eyes with abnormal FDT results, 51% developed abnormal SAP results after 4 to 27 months, whereas none of the eyes with normal FDT results developed abnormal SAP results (P<0.05). In perimetrically normal eyes with abnormal FDT results, converters had a greater cup-to-disc ratio, more eyes with GON, larger and deeper cups, and worse FDT mean deviation than nonconverters (P<0.05). The IOP and CCT did not differ between the 2 groups. The RR of subsequent SAP abnormality corresponding to abnormal FDT sectors was 5.38 (95% confidence interval, 3.61-8.04; P<0.05). CONCLUSIONS: In perimetrically normal eyes of OAG patients, FDT detected visual field loss in almost 2 of every 3 of these eyes and also predicted to some extent future visual field loss on SAP. Severity of glaucomatous neuropathy at baseline was related to conversion of abnormalities on FDT to visual field loss on SAP.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Transtornos da Visão
/
Campos Visuais
/
Doenças do Nervo Óptico
/
Glaucoma de Ângulo Aberto
/
Testes de Campo Visual
Tipo de estudo:
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Ophthalmology
Ano de publicação:
2010
Tipo de documento:
Article