Your browser doesn't support javascript.
loading
The influence of the type of contraction on the masseter muscle EMG power spectrum.
Nadeau, S; Bilodeau, M; Delisle, A; Chmielewski, W; Arsenault, A B; Gravel, D.
Afiliação
  • Nadeau S; School of Rehabilitation, Faculty of Medicine, University of Montreal, Montreal, Quebec, Canada; Research Centre, Montreal Rehabilitation Institute, 6300 Darlington Av., Montreal, Quebec, Canada.
J Electromyogr Kinesiol ; 3(4): 205-13, 1993.
Article em En | MEDLINE | ID: mdl-20870535
Different behaviours of the EMG power spectrum across increasing force levels have been reported for the masseter muscle. A factor that could explain these different behaviours may be the type of contraction used, as was recently shown for certain upper limb muscles(5). The purpose of this study was to compare, between two types of isometric contractions, the behaviour of EMG power spectrum statistics (median frequency (MF) and mean power frequency (MPF)) obtained across increasing force levels. Ten women exerted, while biting in the intercuspal position, three 5 s ramp contractions that increased linearly from 0 to 100% of the maximal voluntary contraction (MVC). They also completed three step contractions (constant EMG amplitude) at each of the following levels: 20, 40, 60 and 80% MVC. EMG signals from the masseter muscle were recorded with miniature surface electrodes. The RMS, as well as the MPF and MF of the power spectrum were calculated at 20, 40, 60 and 80% MVC for each type of contraction. As expected, the RMS values showed similar increases with increasing levels of effort for both types of contractions. Different behaviours for both MPF (contraction(∗)force interaction, ANOVA, P<0.05) and MF (contraction(∗)force interaction, ANOVA, P>0.05) across increasing levels of effort were found between the two types of contraction. The use of step contractions gave rise to a decrease of both MPF and MF with increasing force, while the use of ramp contractions gave rise to an increase in both statistics up to at least 40% MVC followed by a decrease at higher force levels. These findings suggest that the type of contraction used does influence the behaviour of the spectral statistics across increasing force levels and that this could explain the differences obtained in previous studies for the masseter muscle.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Electromyogr Kinesiol Assunto da revista: FISIOLOGIA Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Electromyogr Kinesiol Assunto da revista: FISIOLOGIA Ano de publicação: 1993 Tipo de documento: Article País de afiliação: Canadá