Your browser doesn't support javascript.
loading
Contrast-enhanced whole-heart coronary MRI with bolus infusion of gadobenate dimeglumine at 1.5 T.
Hu, Peng; Chan, Jonathan; Ngo, Long H; Smink, Jouke; Goddu, Beth; Kissinger, Kraig V; Goepfert, Lois; Hauser, Thomas H; Rofsky, Neil M; Manning, Warren J; Nezafat, Reza.
Afiliação
  • Hu P; Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02215, USA.
Magn Reson Med ; 65(2): 392-8, 2011 Feb.
Article em En | MEDLINE | ID: mdl-21264933
ABSTRACT
We sought to investigate the T(1) kinetics of blood and myocardium after three infusion schemes of gadobenate dimeglumine (Gd-BOPTA) and subsequently compared contrast-enhanced whole-heart coronary MRI after a bolus Gd-BOPTA infusion with nonenhanced coronary MRI at 1.5 T. Blood and myocardium T(1) was measured in seven healthy adults, after each underwent three Gd-BOPTA infusion schemes (bolus 0.2 mmol/kg at 2 mL/sec, hybrid 0.1 mmol/kg at 2 mL/sec followed by 0.1 mmol/kg at 0.1 mL/sec, and slow 0.2 mmol/kg at 0.3 mL/sec). Fourteen additional subjects underwent contrast-enhanced coronary MRI with an inversion-recovery steady-state free precession sequence after bolus Gd-BOPTA infusion. Images were compared with nonenhanced T(2) -prepared steady-state free precision whole-heart coronary MRI in signal-to-noise ratio, contrast-to-noise ratio, depicted vessel length, vessel sharpness, and subjective image quality. Bolus and slow infusion schemes resulted in similar T(1) during coronary MRI, whereas the hybrid infusion method yielded higher T(1) values. A bolus infusion of Gd-BOPTA significantly improved signal-to-noise ratio, contrast-to-noise ratio, depicted coronary artery length, and subjective image quality, when all segments were collectively compared but not when compared segment by segment. In conclusion, whole-heart steady-state free precision coronary MRI at 1.5 T can benefit from a bolus infusion of 0.2 mmol/kg Gd-BOPTA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Angiografia por Ressonância Magnética / Meios de Contraste / Vasos Coronários / Meglumina Limite: Adult / Female / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Angiografia por Ressonância Magnética / Meios de Contraste / Vasos Coronários / Meglumina Limite: Adult / Female / Humans / Male Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos