Comparison of technetium-99m IgG with technetium-99m red blood cells labeling in cardiac blood-pool scintigraphy: a preliminary study.
Hell J Nucl Med
; 14(1): 30-3, 2011.
Article
em En
| MEDLINE
| ID: mdl-21512662
ABSTRACT
This first clinical prospective study was conducted to use of technetium-99m immunoglobulin G ((99m)Tc-IgG) as compared with autologous (99m)Tc-red blood cells (RBC) in gated blood pool ventriculography. We studied 12 patients who referred to us for a possible diagnosis of liver hemangioma or infection. Six patients underwent gated planar blood pool (GPBP) acquisition using (99m)Tc-RBC and 6 GPBP acquisition using (99m)Tc-IgG. The use of (99m)Tc-IgG in cardiac blood pool studies provided comparable images to (99m)Tc-RBC. In conclusion, (99m)Tc-IgG, which is readily available and needs only a single injection, may be an attractive alternative to (99m)Tc-RBC for the estimation of various cardiac function parameters like left ventricular function.