Automated near-continuous glucose monitoring measured in plasma using mid-infrared spectroscopy.
Jax, Thomas; Heise, Tim; Nosek, Leszek; Gable, Jennifer; Lim, Gene; Calentine, Christopher.
Afiliação
  • Jax T; Profil Institut für Stoffwechselforschung GmbH, Neuss, Germany.
J Diabetes Sci Technol ; 5(2): 345-52, 2011 Mar 01.
Article em En | MEDLINE | ID: mdl-21527104
OBJECTIVE: There are increasing calls for a precise, automated system to enable tight glycemic control and to avoid hypoglycemia in an intensive care unit setting. OptiScan Biomedical has developed a glucose monitor based on mid-infrared spectroscopy that withdraws blood samples (120 µl) and measures plasma glucose. The goal of this study was to validate the performance of the OptiScan Model 5000 over a wide range of glycemic levels in patients. RESEARCH DESIGN AND METHODS: Sixty people with type 1 (n = 18) or type 2 (n = 42) diabetes who were otherwise healthy were connected to OptiScanners. Their blood glucose concentrations were kept in a euglycemic, hypoglycemic (<75 mg/dl), and hyperglycemic (>180 mg/dl) range by intravenous administrations of insulin and glucose. OptiScanner venous blood samples were automatically withdrawn every 15 minutes. Reference measurements were done using the YSI 2300 glucose analyzer. RESULTS: The aggregate data points (1155 paired readings) were within International Organization for Standardization standards, with 98.6% of the glucose values within ±20% above 75 mg/dl and ±15 mg/dl below this value. A Clarke error grid analysis showed a total of 1139 points (98.6%) in zone A. Points outside of A exceeded the A zone boundary by an average of 4.3%. The r(2) was 0.99. The total coefficient for variance was 6.4%. CONCLUSIONS: These results show that the OptiScanner is highly accurate in healthy patients with diabetes across a wide range of glucose values. Mid-infrared spectroscopy may become the method of choice for highly accurate, high frequency, automated glucose measurements and may thus enable better glycemic control in critically ill patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Infravermelho / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Infravermelho / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Alemanha