Your browser doesn't support javascript.
loading
Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability.
Park, Jae Suk; Cho, Dae-Chul; Sung, Joo Kyung.
Afiliação
  • Park JS; Department of Neurosurgery, Kyungpook National University Hospital, Daegu, South Korea.
J Spinal Disord Tech ; 25(5): 254-8, 2012 Jul.
Article em En | MEDLINE | ID: mdl-21666509
ABSTRACT
STUDY

DESIGN:

A retrospective outcome study.

OBJECTIVE:

The purpose of this study was to analyze the clinical outcomes of our experience with the C2 translaminar screw technique and evaluate its feasibility as an alternative or salvage of the pedicle screw. SUMMARY OF BACKGROUND DATA Pedicle screws are the most biomechanically stable screws for use in atlantoaxial fixation. However, in cases with elevated risk of neurovascular complications or failure of screw insertion attempts, a reliable alternative technique is required.

METHODS:

Fourteen patients with atlantoaxial instability underwent posterior fixation with C2 translaminar screws. Indications included traumatic instability, atlantoaxial subluxation, os odontoideum, and fusion failure after anterior fixation of a type II odontoid process fracture. A total of 26 screws were inserted and all patients were assessed both clinically and radiographically.

RESULTS:

No procedure-related complications or hardware failures were observed during the follow-up. Postoperative computed tomographic scans revealed laminar breach in 3 patients and none of these resulted in neurological symptoms. Radiographically demonstrated bony fusion was established in 11 patients (91.7%) at follow-up over 6 months, and 5 patients with initial neurological deficit demonstrated at least 1 grade improvement by Frankel grade.

CONCLUSIONS:

C2 translaminar screws provide surgeons with an expanded option for posterior fusion in high cervical lesions. This technique is safe and easy to adopt with a favorable rate of successful fusion. We believe that preoperative planning using computed tomographic scan is mandatory and use of an additional connector may reduce the stress and strain of the screws.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Atlantoaxial / Fusão Vertebral / Vértebra Cervical Áxis / Parafusos Ósseos / Fraturas da Coluna Vertebral / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Spinal Disord Tech Assunto da revista: ORTOPEDIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação Atlantoaxial / Fusão Vertebral / Vértebra Cervical Áxis / Parafusos Ósseos / Fraturas da Coluna Vertebral / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Spinal Disord Tech Assunto da revista: ORTOPEDIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Coréia do Sul