Microfluidics-mediated isothermal detection of enzyme activity at the single molecule level.
Annu Int Conf IEEE Eng Med Biol Soc
; 2011: 3258-61, 2011.
Article
em En
| MEDLINE
| ID: mdl-22255034
Conventional analysis of enzymatic activity, often carried out on pools of cells, is blind to heterogeneity in the population. Here, we combine microfluidics with a previously developed isothermal rolling circle amplification-based assay to investigate multiple enzymatic activities in down to single cells. This microfluidics-meditated assay performs at very high sensitivity in picoliter incubators with small quantities of biological materials. Furthermore, we demonstrate the assay's capability of multiplexed detection of at least three enzyme activities at the single molecule level.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Microfluídica
/
Enzimas
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
Limite:
Humans
Idioma:
En
Revista:
Annu Int Conf IEEE Eng Med Biol Soc
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
Dinamarca