Determination of paroxetine in serum treated with simple pretreatment by pre-column high-performance liquid chromatography using 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride as a fluorescent labeling reagent.
Inoue, Hirofumi; Harada, Takuya; Eto, Seiji; Nakashima, Ken; Ibusuki, Takuya; Kosha, Keiko; Date, Yuuko; Sanematsu, Emiko; Shinohara, Yoshitake; Takahashi, Kojiro; Yoshimura, Reiji; Nakamura, Jun; Kojima, Eijiro; Tsuruta, Yasuto.
Afiliação
  • Inoue H; Faculty of Pharmacy and Pharmaceutical Sciences, Fukuyama University, Fukuyama, Hiroshima, 729-0292, Japan.
Biomed Chromatogr ; 27(6): 688-90, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23319205
ABSTRACT
The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high-performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 µL) with acetonitrile and o-phthalaldehyde, paroxetine was derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed-phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within-day and day-to-day relative standard deviations were 3.0-3.4 and 2.7-8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal-to-noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 µL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ftalimidas / Cromatografia Líquida de Alta Pressão / Paroxetina / Corantes Fluorescentes Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ftalimidas / Cromatografia Líquida de Alta Pressão / Paroxetina / Corantes Fluorescentes Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão