Your browser doesn't support javascript.
loading
Electrical property sensing biopsy needle for prostate cancer detection.
Mishra, V; Schned, A R; Hartov, A; Heaney, J A; Seigne, J; Halter, R J.
Afiliação
  • Mishra V; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
Prostate ; 73(15): 1603-13, 2013 Nov.
Article em En | MEDLINE | ID: mdl-23996675
BACKGROUND: Significant electrical property differences have been demonstrated to exist between malignant and benign prostate tissues. We evaluated how well a custom designed clinically deployable electrical property sensing biopsy needle is able to discriminate between these tissue types in an ex vivo prostate model. METHODS: An electrical impedance spectroscopy (EIS) sensing biopsy (Bx) needle was developed to record resistive (ρR) and reactive (ρX) components of electrical impedance from 100 Hz to 1 MHz. Standard twelve-core biopsy protocols were followed, in which the EIS-Bx device was used to gauge electrical properties prior to extracting tissue cores through biopsy needle firing from 36 ex vivo human prostates. Histopathological assessment of the cores was statistically compared to the impedance spectrum gauged from each core. RESULTS: The magnitudes of the mean resistive and reactive components were significantly higher in cancer tissues (P < 0.05). ROC curves showed that ρR at 63.09 kHz was optimal for discriminating cancer from benign tissues; this parameter had 75.4% specificity, 76.1% sensitivity, and ROC AUC of 0.779. Similarly, 251.1 kHz was optimal when using ρX to discriminate cancer from benign tissues; this parameter had a 77.9% specificity, 71.4% sensitivity, and ROC AUC of 0.79. CONCLUSION: Significant electrical property differences noted between benign and malignant prostate tissues suggest the potential efficacy an EIS-Bx device would provide for cancer detection in a clinical setting. By sensing a greater fraction of the prostate's volume in real-time, the EIS-Bx device has the potential to improve the accuracy of cancer grading and volume estimation made with current biopsy procedures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Biópsia por Agulha Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans / Male Idioma: En Revista: Prostate Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Biópsia por Agulha Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans / Male Idioma: En Revista: Prostate Ano de publicação: 2013 Tipo de documento: Article