Your browser doesn't support javascript.
loading
[Endoscope-assisted repair of pediatric blowout fractures of orbital floor with autologous bone fragment].
Jiang, Xin-li; Miao, Hui-peng; Zhou, Zhong-you; Zhang, Xiao-rong; Liu, Jin-ling.
Afiliação
  • Jiang XL; Department of Ophthalmology, Third Affiliated Hospital, Hebei Medical University, Shijiazhuang 050051, China.
  • Miao HP; Department of Ophthalmology, Third Affiliated Hospital, Hebei Medical University, Shijiazhuang 050051, China.
  • Zhou ZY; Department of Ophthalmology, Third Affiliated Hospital, Hebei Medical University, Shijiazhuang 050051, China. Email: hbeyedr@126.com.
  • Zhang XR; Department of Ophthalmology, Third Affiliated Hospital, Hebei Medical University, Shijiazhuang 050051, China.
  • Liu JL; Department of Ophthalmology, Third Affiliated Hospital, Hebei Medical University, Shijiazhuang 050051, China.
Zhonghua Yi Xue Za Zhi ; 93(33): 2664-6, 2013 Sep 03.
Article em Zh | MEDLINE | ID: mdl-24360049
ABSTRACT

OBJECTIVE:

To explore the clinical efficacy of endoscopic repairing pediatric blowout fracture of orbital floor with autologous bone fragment.

METHODS:

A total of 12 cases with blowout fractures of orbital floor between March 2010 and June 2012 at Third Hospital of HeBei Medical University were reviewed. They underwent nasal endoscopic reconstruction of autologous bone fragment in situ. Medicinal biomaterial glue was used for fixation. A 6-month follow-up was performed and the therapeutic efficacies of anatomic and functional recovery were evaluated.

RESULTS:

No further vision loss or infection occurred postoperatively. Diplopia disappeared over a period of 3 days to 6 months. At 3 months post-operation, diplopia vanished completely (n = 9), and peripheral vision diplopia persisted (n = 3). Only 1 case had still peripheral vision diplopia at 6 months. Enophthalmos ≥ 2 mm (n = 1), 1 mm (n = 3) for one week after surgery and only 1 mm (n = 1) at one month follow-up. Passive traction test was negative in all cases and computed tomograph (CT) revealed no bone redislocation postoperatively.

CONCLUSION:

Endoscopic repair of pediatric blowout fracture of orbital floor with autologous bone fragment in situ is both effective and safe.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Órbita / Fraturas Orbitárias / Transplante Ósseo / Endoscopia Tipo de estudo: Observational_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: Zh Revista: Zhonghua Yi Xue Za Zhi Ano de publicação: 2013 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Órbita / Fraturas Orbitárias / Transplante Ósseo / Endoscopia Tipo de estudo: Observational_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: Zh Revista: Zhonghua Yi Xue Za Zhi Ano de publicação: 2013 Tipo de documento: Article País de afiliação: China