Aerosol penetration relative to sentinel cage configuration and orientation.
Bunner, B L; Posa, F G; Dobson, S E; Broski, F H; Boobar, L R.
Afiliação
  • Bunner BL; U.S. Army Biomedical Research and Development Laboratory, Fort Detrick, Frederick, MD 21701-5010.
J Am Mosq Control Assoc ; 5(4): 547-51, 1989 Dec.
Article em En | MEDLINE | ID: mdl-2482340
ABSTRACT
Aerosol movement into 4 different sentinel cage configurations at 0 degrees, 30 degrees and 60 degrees orientation relative to the aerosol flow in a wind tunnel was studied using a quartz crystal microbalance cascade impactor. The data suggest that a cylinder, screened on all sides, with the longitudinal axis perpendicular to the ground would provide a consistent cage profile to the wind regardless of wind direction changes and thereby reduce aerosol environment variability among cages.