Your browser doesn't support javascript.
loading
Phased-array of microcoils allows MR microscopy of ex vivo human skin samples at 9.4 T.
Göbel, K; Gruschke, O G; Leupold, J; Kern, J S; Has, C; Bruckner-Tuderman, L; Hennig, J; von Elverfeldt, D; Baxan, N; Korvink, J G.
Afiliação
  • Göbel K; Department of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany.
Skin Res Technol ; 21(1): 61-8, 2015 Feb.
Article em En | MEDLINE | ID: mdl-25066249
PURPOSE: The aim of this study was to demonstrate the feasibility of a custom-made phased-array microcoil within a 400 MHz animal system for the morphological characterization of human skin tissue in correlation with histopathology. MATERIALS AND METHODS: A dedicated 7-channel microcoil-based MR detector arranged in a phased-array geometry was developed to combine the advantages of both a large field of view and a high signal-to-noise ratio. Standard gradient echo sequences were adapted for the characterization of skin morphology ex vivo. RESULTS: In this study, the feasibility of using this type of microdetector, combined with specially manufactured sample holders, to achieve high-resolution MR images of fresh and formalin-fixed, normal and hidradenitis suppurativa diseased skin was successfully demonstrated. The setup presented in this work allows reliable acquisitions of high-resolution images with in-plane resolution up to 25 × 25 µm², and 100 µm in the orthogonal direction, thereby allowing the differentiation of typical layers of the skin, sebaceous glands and hair follicle. CONCLUSION: This study demonstrates that MR microscopy on skin biopsies can be applied at low cost on a standard animal MR imaging system. The successful imaging of different skin structures ex vivo is a prerequisite for non-invasive, in vivo application of skin MR microscopy for accurate complementary disease diagnosis in dermatology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Manejo de Espécimes / Imageamento por Ressonância Magnética / Hidradenite Supurativa / Magnetismo / Microscopia Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Skin Res Technol Assunto da revista: DERMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Manejo de Espécimes / Imageamento por Ressonância Magnética / Hidradenite Supurativa / Magnetismo / Microscopia Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Skin Res Technol Assunto da revista: DERMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha